Commit Graph
306 Commits
Author SHA1 Message Date
Marc Billow e6d7dcddc8 Add dryer Drum Clean+ tracking; fix multi-entry DrumCleanLog parsing (#258)
Dryers report the same DrumCleanProposal_/WashingTimes_/DrumCleanLog_
options[] tokens washer.py already models for issue #9, so
drum_clean_cycles_remaining/drum_clean_last_cleaned move to laundry.py and
get bound on dryer's /course/vs/0 too.

DrumCleanLog_ on the reporter's dump is a '|'-joined history of every past
clean rather than washer's single bare timestamp -- the shared helper now
takes the last (most recent) entry, which turns out to also fix a latent
bug on four existing washer fixtures whose own DrumCleanLog_ was already
multi-entry and silently failing to parse into drum_clean_last_cleaned.

No heat-exchanger-clean tracking was found in either dump #258 supplied;
noted in dryer.py so a future report knows this was checked.
2026-08-03 19:14:29 +00:00
Marc Billow cf09247e39 Add AC UV LED, ventilation alarm, and PM1 filter support (issue #270)
TP1X_FAC_TIME_23K reports three previously unbound hrefs: a UV-C
sterilization LED and a ventilation-reminder alarm (both plain On/Off
toggles), and a second PM1-rated dust filter with no live usage/status
fields on this particular dump.

The PM1 filter capability gates each entity on its own field's presence
rather than a blanket ignore, since the TP1X_DA-AC-CAC-01001_0000 cassette
AC (issue #191) reports the same href with full live data -- this also
closes two of that device's ten documented coverage gaps (UV LED and the
PM1 filter) as a side effect.
2026-08-03 19:07:03 +00:00
Marc Billow 3ef64eae52 Add dehumidifier display switch and watertank lighting (issues #271, #231)
The TP1X_DA_AC_DHM_01001_0000 revision (model AY70H18100GTD) additionally
reports /display/vs/0 (same shape as air_purifier's screen toggle, reused
directly) and /watertank/lighting/vs/0 (on/off, color, and brightness for
the tank's ambient light, plus a diagnostic alarm-status flag). Both issues
submitted the identical dump, so one fix covers both reports.

Also adds x.com.st.d.dehumidifier to the /oic/d device-type routing table
now that a dump confirms it.
2026-08-03 18:59:22 +00:00
Marc Billow 24d48d70b9 Reformat after merging main
main advanced past this branch (PR #263, entity-less-after-restart fix)
with unformatted changes to coordinator.py's tests; re-running ruff
format picks those up. Merge commit itself had no conflicts.
2026-08-03 00:21:34 +00:00
Marc Billow 18596f23ec Merge remote-tracking branch 'origin/main' into claude/ruff-pyright-ci-stage-gxph0t 2026-08-03 00:20:59 +00:00
Marc Billow 679c3d2bce Fix remaining pre-existing ty diagnostics in test files
Completes the isinstance/cast narrowing + Optional-field assert pattern
across the last batch of test files. custom_components and tests are
now both fully clean under ruff check, ruff format --check, and ty check.
2026-08-03 00:14:58 +00:00
Marc Billow 36a642135b Fix pre-existing ty diagnostics in a second batch of test files
Same isinstance/cast narrowing and Optional-field assert pattern as the
prior commits, covering the airconditioner, fridge, washer, operational,
subdevices, sensor_hysteresis, laundry, select_options, identity and
entities test files.
2026-08-03 00:11:05 +00:00
Marc Billow 07061c734d Fix more pre-existing ty diagnostics in test files
Continues narrowing SamsungEntityDescription accesses to the correct
subclass and asserting Optional write_fn/match_fn/exists_fn fields are
set before calling them, per the pattern established in the previous
commit.
2026-08-03 00:03:08 +00:00
Marc Billow daf7e3787f Add ruff (lint + format) and ty (type checking) to the project
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.

Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).

Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
2026-08-02 23:56:38 +00:00
Marc Billow 00abfb9770 Tighten the #254 fix after review
No behavior change to the fix itself; cleanup only.

Production:

- Trim the narrative that was told three times over (coordinator
  docstring, test docstring, inline comment) down to one telling in the
  docstring, where someone tempted to remove the gate will be standing.
- Guard the second degraded return in _async_update_data on
  self._discovered too. That arm is currently unreachable before
  discovery only because every _observe.apply() call site happens to be
  gated on post-discovery state -- a non-local accident across four call
  sites. Stating the precondition where it is relied on makes it the same
  explicit rule _defer_reconnect_for now applies.

Tests, 7 -> 4 with better discrimination:

- test_session_closed_when_first_refresh_fails asserted _close_session
  was called, which the reconnect path already does on its own -- so it
  passed with the fix removed. Merged into the persistent-timeout test
  and re-pointed at async_close, which only setup calls.
- Dropped the __new__-built unit test: it set one attribute on an
  otherwise uninitialized instance, so it asserted the gate's position in
  the function rather than any behavior, and would have errored rather
  than failed if reordered.
- Folded the timeout-budget test into the recovery test it was a
  byte-for-byte copy of, and replaced both hand-rolled call counters with
  the side_effect=[exc, resources] idiom already used in this file.

Each of the three production changes is now independently covered:
removing any one of them alone fails the suite.
2026-08-02 23:44:38 +00:00
Marc Billow 9fc04e179e Fix devices coming up entity-less after a Core restart
A failed DTLS handshake on the very first poll was being swallowed, so
the config entry loaded with no entities at all and stayed that way until
the user reloaded that device by hand (issue #254).

_poll_once() connects when there is no session yet, so connect()'s
handshake timeout reaches _async_update_data as a TimeoutError -- the
same type a slow blockwise transfer raises mid-session.
_defer_reconnect_for() only knew the mid-session meaning and deferred it,
making _async_update_data return flatten([], {}) == {} instead of
raising. DataUpdateCoordinator counts any non-raising return as success,
so async_config_entry_first_refresh saw a healthy first refresh and
skipped ConfigEntryNotReady, and setup forwarded the platforms with
`bound` still empty. Platforms enumerate `bound` once and have no dynamic
add-listener, so a later cycle repopulating it added nothing: every
restored entity sat unavailable until a manual reload.

Gate the deferral on self._discovered. Before the first discovery a poll
failure now takes the normal path -- one reconnect attempt, then
UpdateFailed -> ConfigEntryNotReady -- so HA retries on its own backoff
until the handshake goes through.

Two related fixes in the same failure path:

- Close the DTLS session on EVENT_HOMEASSISTANT_STOP, not only on entry
  unload. HA does not unload entries on a Core restart, so async_close()
  never ran and the previous run's association was left orphaned on the
  appliance -- which is what makes the next run's handshake time out in
  the first place. The fixed source port still covers the unclean-exit
  case where no close_notify can be sent.

- Close the session when first refresh fails. _poll_once deliberately
  leaves it open on a TimeoutError, so a failed setup abandoned a bound
  UDP socket on a port that is fixed per device by design, and each HA
  retry bound another socket to that same port.
2026-08-02 23:26:50 +00:00
Marc Billow 42a1812967 Merge pull request #261 from mbillow/claude/pr-242-review-merge-nny8ug
feat: discover UUID-prefixed subdevices advertised only via /oic/res (Pattern C, #241)
2026-08-02 17:42:46 -04:00
Marc Billow e926905517 fix: dedupe Pattern C's UUID-prefix candidates against Pattern B (#242 review)
Both the /subdevices/vs/0 subdeviceIdList (Pattern B) and an /oic/res
link's UUID prefix (Pattern C) can name the same physical subdevice --
TP2X_FAC_BORA_21K, the Pattern B reporter's own board, does. Filtering
the two candidate lists against each other with a plain set difference
missed this when the two sources disagree on the UUID's case, letting
the same subdevice get probed and materialized twice under two
different keys.

Move the guard into _probe_prefixed itself, keyed on a
case-normalized id, so neither pattern can add a candidate the other
already claimed regardless of casing.
2026-08-02 21:40:34 +00:00
Hyunook 6bcf8f3bec feat: discover UUID-prefixed subdevices advertised only via /oic/res (Pattern C, #241)
AWM-WW-AID-26-ONEBODY (washer+dryer combo) reports numofsubdevice='2' on
/multidevice/vs/0 but carries no /subdevices/vs/0 (no subdeviceIdList --
Pattern B's signal) and 4.04s /device/1 and /device/2 (Pattern A's). The
washer subdevice's UUID appears only as the path prefix of the
x.com.samsung.da.multidevice link in /oic/res; GET /<uuid>/device/0
answers the washer's own full Collection batch (model ..._WF80H vs the
master's ..._DV80H27H).

Treat every UUID path prefix seen in /oic/res as a prefixed-subdevice
candidate (minus ones subdeviceIdList already named), probed with the
same tolerated-404 seed RETRIEVE as Pattern B -- the shared body is
factored into _probe_prefixed. discover_partitioned's entity-level
liveness gate still decides materialization, so a UUID link with no live
sibling behind it contributes nothing.

Fixture is a live capture from the reporting board (serials/MACs/di
scrubbed); tests cover discovery, probe hygiene, washer-side entity
binding, and that the master's own entity set is unchanged.
2026-08-02 21:40:34 +00:00
Ian P. Christian 6efee761d9 Add Samsung EHS (Eco Heating System) heat pump support
Adds a device registry for the TP1X_DA_AC_EHS board family: separate
zone1 (space heating/cooling) and dhw (domestic hot water) loops.
zone1 is exposed as power switch + mode select + current/target
temperature sensor/number -- it's a leaving-water-temperature
setpoint, not a thermostat, so no HA platform fits it better. dhw
gets a composite water_heater entity, using the same
primary-resource-plus-sibling-reads shape climate.py already uses
for the AC (PR #247 review feedback: "Having water heaters
automatically leverage the right platform would be pretty cool!").
The unit's away mode is a device-wide switch, not the water_heater
AWAY_MODE feature -- /option/outgoing/vs/0 has no dhw-scoped sibling
and covers zone1 too, so presenting it on the DHW card would
misstate its scope.

Operation modes (Eco/Std/Force/Power) map onto HA's own standard
water_heater states, the same mapping HA core's smartthings
integration uses for this exact Samsung capability over the cloud
API. Device codes are matched case-insensitively on the read side.
The DHW entity takes a catalog name ("Hot water") rather than the
bare device name -- unlike the AC's climate card, it is one loop of
a two-loop device.

Both temperature ranges fall back as a pair: a resource reporting a
minimum but no maximum yields no range at all rather than mixing a
device bound with an invented default, matching climate._range().
Increment fallbacks test for None instead of using `or`, so a
genuine 0 survives.

set_temperature honours the optional operation_mode HA's
water_heater service schema forwards, setting the mode (and powering
the loop on) before the setpoint, the same way climate's
set_temperature handles hvac_mode.

Entity names are translated into Czech and Dutch following each
file's existing terminology conventions.

Verified against a real TP1X_DA_AC_EHS_01001_0000 diagnostics dump
(firmware AEH-WW-TP1-22-AE6000_17260402); golden-regression fixture
and full test coverage included.
2026-08-02 22:18:43 +01:00
Marc Billow e309d3e7b8 Merge pull request #225 from atc722/agent/qooker-support
Route Samsung Bespoke Qooker to microwave registry
2026-08-02 12:22:10 -05:00
Geunwon Mo 5c275753d4 Report whether the auto-clean cycle is running, and how far through
`/option/autoclean/vs/0` carries three fields and only `settingStatus` was read.
That one says the feature is enabled, which it is whether or not the unit is
drying right now, so nothing reported an actual cycle.

    settingStatus: On      <- the existing auto_clean switch
    status:        Stop    supportedStatus: [Start, Stop]
    progress:      0

Adds a binary sensor for `status` and a percentage sensor for `progress`.

Measured on a TP1X_DA-AC-CAC-01001, sampling the resource every eight seconds
across a cycle: `Start` with progress 98 while it ran, then `Stop` with progress 0
the moment it finished. The percentage matches the figure the appliance shows on
its own display, checked against 55% mid-run.

Golden state keys updated for the 18 fixtures that bind AUTO_CLEAN. The change is
additive — no key was removed from any of them.

Full suite passes (1070 tests, Python 3.13 via requirements-dev.txt).
2026-08-02 22:01:27 +09:00
hoon f9cd857ced Support Samsung Bespoke Qooker routing 2026-08-01 10:47:00 +09:00
Marc Billow 93744e80f4 Merge pull request #227 from blka/observe-grace-early-exit-upstream
Observe grace-period early-exit (first-refresh ~15s -> ~0.4s)
2026-07-31 20:20:22 -05:00
Marc Billow 3c6c7f246f Merge branch 'main' into ac-filter-reset 2026-07-31 20:13:40 -05:00
Geunwon Mo 618fc5fa51 Add x.com.st.d.hood to _OIC_TYPE_TO_KEY, and document why oic.d.cooktop is not
Measured on nine Samsung appliances on Korean-market firmware, every one of
which populates /oic/d with a concrete type:

    4x  oic.d.airconditioner   AJ023CN1UBC1 system A/C, "Samsung System A/C"
    3x  oic.d.refrigerator     "[refrigerator] Samsung"
    1x  oic.d.cooktop          TP1X_DA-KS-COOKTOP, "Samsung Cooktop"
    1x  x.com.st.d.hood        AHD-WW-TP1-22-COMMON, "Samsung Hood"

Every one agreed with what for_device_by_model already concluded from the board
token, so this is corroboration rather than a correction.

`x.com.st.d.hood` was the one type with a registry to point at and no row, so
this adds it.

`oic.d.cooktop` is left out on purpose, with a comment saying why: the induction
above reports it, but `cooktop` and `induction_cooktop` are unrelated registries
that happen to share the English word, and the OCF type cannot tell them apart.
Mapping it to either key would misroute the other, and since resolve() consults
this table first it would override a COOKTOP/CT board token that had it right.
Same shape of argument as the existing oic.d.robotcleaner note.

One incidental data point on the docstrings' "only ever helps a minority of
dumps": that may understate it. Nine out of nine here answer /oic/d with a usable
type, across four families. Not enough hardware to generalise from, but enough
that it looks less like a rare bonus than the comments assume.

Verified: the full suite passes (1024 tests, Python 3.13 via
requirements-dev.txt).
2026-08-01 09:02:49 +09:00
Marc Billow 6166f63570 Merge pull request #224 from mbillow/claude/issue-triage-batch-h4n2wq
Issue triage batch: #207, #189, #208, #181/#183, #196, #210 + contributing docs
2026-07-31 15:22:55 -05:00
Marc Billow b7d3f86ec7 fix: address code review feedback on issue-triage batch PR (#181, #183, #189, #196, #207, #208, #210)
common:
- Make KIDS_LOCK_GENERIC also a read-only BinarySensorDesc (device_class='lock'),
  flipping value_fn to not bool(v) so /kidslock/0 value=False and
  /kidslock/vs/0 kidsLock='Ready' render with the same polarity ('On'
  means open/unlocked per HA's lock device class). The old SwitchDesc
  form never honored device_class='lock' -- HA's switch platform only
  accepts 'outlet'/'switch' -- so the surface was a plain switch whose
  'On' meaning drifted across boards. Tests updated.

air_monitor:
- Add state_class='measurement' to dust/fine_dust/super_fine_dust so
  the readings feed HA long-term statistics (co2 already had it).
- Import _AIR_QUALITY_SENSORS from air_purifier instead of duplicating
  it byte-for-byte; update common.sensor_item_value's docstring to
  mention the third caller.

by_type/__init__: drop trailing whitespace on the new 'ASM' line.

translations/en.json + nl.json: move the new 'dnd' switch entry to its
correct alphabetical position (after display_light, before fast_preheat).

SKILL.md: add an explicit read-side rule to §5's educated-guesses
section -- guessed unit/device_class/state_class on a SensorDesc
silently mislabels readings forever with no 4.xx to catch it (unlike
guessed writes, which the device rejects). The prior air_monitor
docstring cited this carve-out as if it existed; now it does.

tests/water_purifier (issue #196): change the ailite fixture's
favorite.defaultTemperature from '85' to '50' so the test actually
reproduces the reported bug -- '50' is in showList only, so a
descriptor reading from supportedList would fail the assertion that
the current default is in its options list.
2026-07-31 15:17:18 -05:00
Marc Billow fd86c54f18 Merge pull request #233 from pedrodivisez/feat/ac-odor-controller-cs-translation
AC: bind SmartCoolClean odor-controller tokens; add Czech translation
2026-07-31 14:49:26 -05:00
Jelle Lauwers 9ab3c5827c Rename finish_time debounce -> hysteresis to match actual behavior
The gate holds finish_time at its last reported value until a new one
differs by at least a configured number of minutes, regardless of how
long that difference has been building up -- a magnitude-based deadband,
not a time-based debounce (which would wait for the value to stay put for
N minutes before accepting it). debounce invited the wrong mental model
for anyone reading the option name or the code later, so rename it
throughout before the option name ships: CONF_FINISH_TIME_DEBOUNCE_MINUTES
-> CONF_FINISH_TIME_HYSTERESIS_MINUTES, SensorDesc.debounce -> hysteresis,
LocalThingsSensor._debounce/_debounced_value -> _apply_hysteresis/
_hysteresis_value, and the options-flow data key/translations to match.
2026-07-31 20:27:48 +02:00
Jelle Lauwers d90562017f Add configurable finish_time debounce to cut recorder churn further
Minute-rounding stopped identical values from re-logging, but finish_time
still updates on nearly every poll because now() + remaining is a
continuously-drifting value between the device's own remaining-time
revisions, and washers/dryers/dishwashers commonly revise that estimate
by a minute or two mid-cycle anyway -- both are real, small changes that
individually don't matter but each cost a recorder/logbook entry.

Add a per-device Options Flow setting (finish_time_debounce_minutes,
default 3) and a SensorDesc(debounce=True) opt-in. LocalThingsSensor now
caches the last value it actually reported and only adopts a new one once
it differs by at least the configured threshold, a cycle starts (no prior
cache), or a cycle ends (new value is None) -- 0 disables it entirely,
restoring today's behavior.

Also pass config_entry explicitly into DataUpdateCoordinator's
super().__init__() -- self.config_entry previously relied on an
undocumented ContextVar fallback that upstream has flagged as removed in
HA 2026.8, which the new debounce lookup needed to not be built on top of.
2026-07-31 19:25:45 +02:00
Jelle Lauwers fe9a1128ea Round finish_time to the minute to stop recorder spam
_finish_time added datetime.now(timezone.utc) (fresh seconds/
microseconds every call) to the device's remaining-time duration, so the
returned timestamp differed at the sub-minute level on nearly every poll
even when remainingTime itself hadn't changed. The recorder logged a new
history/logbook entry each time, while the UI rounds the display down to
the minute, making repeated polls look like duplicate identical entries.

Round the result down to the minute so the entity only changes state
when the estimate actually shifts.
2026-07-31 19:07:24 +02:00
Petr Divis f15ee7e563 Update golden fixtures for the new odor-controller entities
CI caught it: 8 pre-existing AC fixtures also carry genuine SmartCoolClean_/
ProgressSmartClean_ tokens in /mode/vs/0 (lnx_rac_heatpump, ara_ww_tp1_22,
windfree_oscillation, tp1x_rac_01001, fac_bora, fac_bora_2in1,
fac_bora_205_flat, cac), so odor_controller_active/odor_controller_progress
now correctly bind there too -- their golden state_keys lists just hadn't
been regenerated. Verified against the actual downloaded CI job log.
2026-07-31 16:39:08 +02:00
Petr Divis d0c68fb5ac AC: bind SmartCoolClean odor-controller option tokens; add Czech translation
- airconditioner.py: odor_controller_active binary_sensor + odor_controller_progress
  sensor, read from the /mode/vs/0 SmartCoolClean_/ProgressSmartClean_ option tokens
  (SmartThings cloud custom.airConditionerOdorController capability). Read-only --
  no confirmed write command.
- Reporter's TP1X_DA-AC-RAC-01001_0000 dump: fan speed and WindFree preset already
  bind via the existing composite climate entity, no code change needed there.
- en.json/nl.json: new entity names for the two additions.
- cs.json: new, full Czech translation catalog (mirrors en.json topology 1:1).
- New fixture + golden + tests locking in the odor-controller behavior.
2026-07-31 16:02:13 +02:00
perseus177 9ee0dbb8f9 feat(airconditioner): filter alarm interval on legacy ARTIK051 boards
Adds the Select the official app offers next to the filter reminder --
180/300/500/700 hours -- which this board generation keeps as a FilterAlarmTime_
token in /mode/vs/0's options[] rather than on a /filter/* resource.

Confirmed on hardware: stepping through all four radio positions in the app
moved that one token and nothing else across all 19 resources, so the token
carries the hour count verbatim; and a local write of 500 to a unit sitting on
700 was accepted and kept, surviving a restart. The cloud exposes none of this,
so it is only available locally. Gated with the counter it belongs to, so
boards carrying a real /filter/airdustfilter/vs/0 threshold keep using that one
-- the gate is covered by a test that injects the token into a newer board's
dump, since no non-legacy fixture carries it and the assertion would otherwise
pass for the wrong reason.

Also settles what filter_time measures: it counts UP -- running time
accumulated since the last filter reset, not time remaining -- which an earlier
revision of that comment explicitly left open. Three independent things agree:
the token rising while the unit runs, FilterAlarmTime_ being the threshold it
is measured against, and /alarms/vs/0's filter entry tracking the counter
across two units on one site (a live unsuffixed 'FilterAlarm'/'Created' at
FilterTime_5595 against the 'FilterAlarm_OFF'/'Deleted' placeholder at 1915).
The alarm clearing by itself the moment the counter dropped under the threshold
is the causal half of that, not just correlation.

Resetting the counter is NOT solved and no reset entity is added. The
descriptor records what was tried, and what the failures do and do not prove,
so the next attempt starts from evidence instead of from scratch. Short
version: the reset is a *command* (custom.dustFilter/resetDustFilter), not a
value write, which is why nothing that writes the counter works; I could not
work out how to drive that command locally. /actions/vs/0 is the obvious local
command channel but publishes no schema, and I did not enumerate guessed action
names against a live appliance.

Written with Claude (AI), on the author's own hardware; every result quoted
above is measured on the device rather than inferred.
2026-07-31 12:41:40 +02:00
blka f19abc7936 feat(observe): early-exit grace wait on success fraction
Replace the fixed time.sleep(GRACE_PERIOD_S) in try_enter_observe_mode
with a threading.Condition.wait_for(predicate, timeout=grace_period_s)
that returns as soon as success_fraction of subscribed hrefs have
notified. Production data (fridge TP2X_REF_20K): all 13 hrefs notify
within ~0.34s of subscribe, so every successful first-refresh / observe
retry was waiting ~14.6s of dead time. AC retry cycles showed the same
16s-fetches-that-transition pattern.

No behavior change on the fallback path (fraction not reached → wait
the full ceiling → MODE_POLL, identical to today). GRACE_PERIOD_S and
SUCCESS_FRACTION unchanged. No smartthings_local library change.
2026-07-31 09:06:19 +02:00
Marc Billow a7d57086e9 feat: add Samsung Air Monitor Plus support (#210)
New device family: a standalone, battery-powered air-quality sensor
puck (ASM-KR-TP1-22-* board) with no controllable-appliance state at
all -- no /power/*, only /energy/battery/vs/0. Routes via both /oic/d
('x.com.st.d.airqualitysensor', confirmed against the real dump) and
the 'ASM' modelNum board token as a fallback.

/sensors/vs/0 reuses air_purifier.AIR_QUALITY's existing {type, value}
items-list decode (common.sensor_item_value) for dust/fine_dust/
super_fine_dust/odor/clean_level, sharing those capabilities' catalog
entries, and adds a CO2 reading those families don't report. The
particulate sensors deliberately get no pm10/pm25/pm1 device_class:
the values read as physically consistent (coarser >= finer) but
Samsung's own two-tier dust naming doesn't confirm where this board's
three-tier split actually maps, and mislabeling a read-side unit is a
standing, not one-shot, kind of wrong -- exposed as plain named
sensors instead. Humidity, battery/charging, and the informational air
quality standard are otherwise straightforward field reads.

/dnd/vs/0 (do-not-disturb window) is a flagged educated guess: the
write contract mirrors the read side's own string/time-format shape
(the safest kind of guess) but has no idle-vs-active dump to confirm
it end-to-end, so it's called out as such in code and will need a
reporter to verify on real hardware. /keepnormalstate/vs/0 and
/sensordatasinks/vs/0 are genuinely opaque (single unexplained value,
no supported-values list) and are ignored rather than guessed at.

Locked in with a scrubbed fixture, golden, and capability tests.
2026-07-31 02:40:02 +00:00
Marc Billow 4d4de23fbb fix(water_purifier): read favorite-temp options from showList (#196)
favorite_hotwater_temperature's options_field read
favorite.supportedList, which is only the four fixed presets. The
SmartThings app also lets the user add one custom value to their own
display list via its "temperatures to display" editor (bounded by
/setting/waterpurifier/vs/0's hotwaterRange), and that value shows up
in favorite.showList but never in supportedList. A unit whose current
default was that custom value rendered as HA's "unknown" state, since
current_option wasn't among the (too-narrow) options list.

showList is a superset of supportedList that always includes whatever
the current default actually is. /setting/waterpurifier/vs/0's own
hot_water_temperature select is untouched -- its write contract for
values off the old preset list still isn't confirmed, so it stays
gated off on boards that don't report supportedHotTemperatures.
2026-07-31 02:14:09 +00:00
Marc Billow e46e935ba0 fix(common): make the vendor kids-lock fallback read-only (#181, #183)
KIDS_LOCK_VS_FALLBACK's write_fn wrote 'Enable', a value no dump in the
fixture corpus (washers, dryers, dishwashers, ovens, ranges, microwaves,
air purifiers, air dressers -- everything that lacks the OCF-standard
/kidslock/0) has ever reported back; every one reports 'Ready' or 'Run'.
It was never a confirmed write contract.

#181's reporter tested directly: writing the *correct* value ('Run')
still returns 4.05, and the SmartThings app itself has no control for
kids lock either -- the resource is genuinely read-only on that
hardware, not just wrong-valued. #183's reporter hit the identical
symptom (toggle does nothing) on a different device family reporting
the same Run/Ready vocabulary.

Convert the entity to a read-only BinarySensorDesc. binary_sensor's
'lock' device class is inverted from the old switch reading (On means
open/unlocked), so value_fn flips accordingly -- callers reading the
flattened 'child_lock' state key need to account for the new polarity.
KIDS_LOCK_GENERIC (the OCF-standard /kidslock/0 boolean) is untouched;
nothing suggests that one is broken.
2026-07-31 02:09:58 +00:00
Marc Billow 5bbc7aeece fix(air_dresser): bind /buzzersound/vs/0 on the TP1_21 board (#208)
DA_DF_TP1_21_COMMON reports a plain {setBuzzerSound, supportedFinishSound}
buzzersound resource -- the same shape laundry.BUZZER_SOUND already
handles for washers/dryers -- but it was unbound because the air_dresser
registry never included that capability. Add it, and lock the board in
with a scrubbed fixture, golden, and capability tests.

The reporter's actual complaint (course cycles showing as raw codes) is
a labelling gap, not a coverage one: this board's course table has no
code->name mapping anywhere in the dump, same as issue #162's board, so
there's nothing to bind here -- it needs a reporter to identify the
codes before they can be named in translations.
2026-07-31 02:03:32 +00:00
Marc Billow e642db462d fix: recognize all-same-hex-digit placeholder serials (#189)
_is_placeholder_serial only caught the ARTIK051_DONGLE_REF family's
'Nothing(SVC)' sentinel. The DA_WM_A51_20_COMMON (ARTIK051) laundry
board family reports a different one instead -- every character the
same repeated hex digit -- which passed through as a real, non-unique
serial. Two different physical units (a washer and a dryer) both
reporting the literal serialNum 'FFFFFFFFFFFFFFF' collided on the
config-entry unique_id, so the second device's config flow aborted as
already configured. Widen the check (both the config_flow.py and
coordinator.py copies) to also catch that sentinel shape.
2026-07-31 01:59:49 +00:00
Marc Billow b8d04b4ae3 Merge pull request #216 from firstof9/fix-hood-fan-write-fallback
fix(hood_fan): fall back to settable min/max when supportedFanSpeed is missing
2026-07-30 20:21:02 -05:00
Marc Billow 0a4b80afc4 Add OCF-spec-confirmed oic.d types: airpurifier, dishwasher, oven
Extend _OIC_TYPE_TO_KEY with three more device categories the OCF Smart
Home Device Specification defines with the same 'oic.d.<category>' shape
as the already-confirmed entries, ahead of seeing them in an actual dump.
Deliberately leave out the rest of a broader compiled oic.d/x.com.st.d
list (lights, switches, sensors, locks, cameras, TVs, generic energy
meters, oic.d.robotcleaner, ...) -- none of those map to a registry this
integration has, and robotcleaner in particular names a different product
than the vacuum_station clean-station registry.
2026-07-31 00:58:26 +00:00
Marc Billow 4f9e630ae9 Route device type from /oic/d as the primary detection signal
/oic/d's `rt` names the device's own OCF device type, which beats
parsing board part numbers whenever a dump populates it. Add
for_device_by_oic_type() and an _OIC_TYPE_TO_KEY table (airconditioner,
dryer, refrigerator, washer, plus SmartThings' x.com.st.d.stickcleaner
and x.com.st.d.steamcloset extensions), and consult it first in
resolve(), ahead of modelNum/description and the resource-signature
fallback.

Thread the master's device_types from read_identity() through
coordinator.py's discovery pass and config_flow's connection probe;
subdevices keep resolving from their own /information/vs/0 (or the
master's registry as a fallback) since they have no /oic/d of their
own read today.
2026-07-31 00:56:17 +00:00
firstof9@gmail.com 8e8f08109a fix(hood_fan): fall back to settable min/max when supportedFanSpeed is missing 2026-07-30 11:33:40 -07:00
Marc Billow 5e86f147d4 fix(subdevices): don't materialize a slot whose only live state is a meter
Issue #214: a single-split ARTIK051_KRAC_18K showed up in HA as two air
conditioners. Its /device/1 answers the same unused-slot shape the Pattern A
reporter's /device/2 does -- every operational rep empty {} -- but also
reports a populated /energy/consumption/vs/1. Running discovery against the
reporter's own quoted subdevice block reproduces their diagnostics exactly
(21 bound entities, the same six hrefs), and of those 21 the only primary
entity with a non-None value is energy_kwh: a lifetime kWh total was the
sole thing passing discover_partitioned's liveness gate and materializing
the phantom.

A single-split AC has one compressor and one energy meter, so a
whole-appliance running total appearing under a second index is the
appliance's own bookkeeping, not evidence that hardware is installed at that
slot. Exclude cumulative meters (HA's total/total_increasing state classes,
plus the energy/water/gas device classes for the descriptors that
deliberately declare no state class) from the gate. The gate never applies
to MAIN, and across the whole fixture corpus every device has at least one
non-meter live primary, so no existing device's entities change -- verified
by the golden for the new fixture being identical to the plain KRAC one.

Also implement async_remove_config_entry_device. A subdevice's HA device
outlives the discovery that created it, so a phantom materialized by an
earlier release stays in the registry with no way to delete it from the UI
-- which is the state the second reporter on that issue is in, with a
refrigerator whose diagnostics now report no subdevices at all. Devices the
entry currently provides still refuse removal. No automatic pruning:
enumeration is one-shot and a real sibling can miss a poll (issue #205 on
the reference hardware), so auto-removal would discard a live subdevice's
name, area and automations on a transient miss.

The new fixture's /device/1 seed is the reporter's verbatim capture; its
master half comes from the corpus's other KRAC unit, with the deviations
spelled out in seeds_note.

Claude-Session: https://claude.ai/code/session_01HzUMLnSWBT64o4BQkVEzXp
2026-07-30 18:23:47 +00:00
Marc Billow ca27bf7f6e docs: de-identify reporter usernames repo-wide, add PII rule to skill
Extended the earlier de-identification (jhkwon19) to the other issue #177
reporter (HJcom), who was named in ~20 spots across coordinator.py,
diagnostics.py, subdevices.py, identity.py, capabilities/airconditioner.py,
a fixture's seeds_note, and several test docstrings/function names. Swapped
all of it for "the reporter"/"the Pattern A reporter", matching the
convention already established for the other reporter.

Added a rule to the adding-device-support skill (end of "Lock it in"):
don't put a reporter's name or GitHub username in code comments,
docstrings, seeds_note, or test/function names -- that prose ships and
sits in git history indefinitely, unlike an issue thread or a
release-notes thank-you. Use "the reporter" / "issue #NNN's reporter" /
a pattern label instead.
2026-07-30 03:06:06 +00:00
Marc Billow ce92d71a92 docs: de-identify the reporter's username in code comments
Comments/docstrings across subdevices.py, coordinator.py, the two fac_bora
fixtures, and their tests named the issue #177/#205 reporter directly.
Swapped to "the reporter"/"the Pattern B reporter" throughout -- no
behavior or test-assertion changes, string content only. HJcom (the
Pattern A reporter) is unaffected.
2026-07-30 02:50:49 +00:00
Marc Billow 8600985a36 review: address Opus findings on the subdevice flat-href fallback
- coordinator: _poll_subdevice_flat_hrefs called sess.pace() outside its
  try block and re-read self._session instead of using the caller's
  already-None-checked reference -- a session closed mid-poll (async_close()
  doesn't hold _session_lock) could crash the whole poll cycle instead of
  just dropping that one sibling. Now takes sess from the caller and guards
  pace() the same as get().
- coordinator: skip flat hrefs already covered by the hot/warm sub-poll
  tiers -- those are refreshed every few seconds by _run_subpolls already,
  so re-fetching them again on the once-per-summary-poll flat pass only adds
  GETs, not freshness. Matters because, unlike the Collection path (always
  one GET), a flat subdevice's summary-poll cost scales with its href count.
- subdevices.py module docstring: corrected an overclaim inherited from PR
  #199 that GET /<uuid>/device/0 had been "confirmed live" on jhkwon19's
  unit. Only an individual /information/vs/0 read was ever actually
  confirmed; the Collection endpoint itself has never been observed to
  answer on any known unit, which is exactly what issue #205 exposes.
- SKILL.md: fixed the numofsubdevice cross-check formula to match what
  coordinator.py actually compares (len(materialized) + 1, not
  len(subdevices) + len(subdevices_skipped)).
- Documented, not yet guarded against: a firmware that echoes state back
  under any unrecognized prefix instead of 4.04ing could pass the flat probe
  and the liveness gate, materializing a phantom duplicate of the master.
  Every board seen so far genuinely 4.04s on paths it doesn't own.
- Added test coverage the review flagged as missing: a materialized (not
  just skipped) flat subdevice re-polling end-to-end through to
  canonical_resources, the hot/warm skip itself, zero-master-hrefs and
  two-UUID no-cross-contamination edge cases, and a golden file for the
  #205 fixture (SKILL.md's "fixture + golden + test" discipline).
2026-07-30 02:44:26 +00:00
Marc Billow e78d941af3 fix(subdevices): fall back to per-href probing when a prefixed subdevice has no /device/0 Collection
Issue #205 shows the UUID-prefixed pattern's own reference device
(TP2X_FAC_BORA_21K) doesn't always answer /<uuid>/device/0, contrary to
what the pattern was built against. When that Collection GET comes back
empty, enumerate_subdevices now probes every href the master itself
answered this cycle individually under the UUID prefix, keeping whichever
ones respond. Subdevice gains a flat_hrefs field for this, and the
coordinator re-polls those hrefs individually each cycle instead of
re-fetching a Collection batch that doesn't exist.

Built a fixture from the reporter's real #205 diagnostics dump: the
fallback finds a candidate through the one href already confirmed live
under this UUID (/information/vs/0, from the #177 thread), and
discover_partitioned's liveness gate correctly holds it back since that
href alone binds no entity -- honest current state, not a guessed
resolution.
2026-07-30 02:25:26 +00:00
Marc Billow fb2d267632 fix(water_purifier): route AILITE_DA-REF-WATERPURIFIER boards correctly (#196)
The AILITE water-purifier board (RWP70F15ANW) spells its modelNum
'...-REF-WATERPURIFIER-...', so the board-token scan hit the bare 'REF'
token before ever reaching 'WATERPURIFIER' and misrouted the device to
the refrigerator registry, whose resource surface shares almost nothing
with a water purifier -- hence the incomplete-coverage warning. Add a
documented carve-out for this one token co-occurrence and a matching
TestBoardTokenAmbiguity exception.

Also bind the water-purifier hrefs this board additionally exposes:
cup-detection status, the settings/sound/{mode,output,volume} trio (read
live, since this board's own supportedModes vocabulary differs from both
laundry's and air_purifier's hardcoded/live sets), and last-pour
statistics.

Separately, gate hot_water_temperature off when the device doesn't report
a supportedHotTemperatures list (only a hotwaterRange/hotwaterLevel pair
with no confirmed write contract) -- previously an empty options list
plus a live current value rendered as 'unknown' in HA, the second bug
reported in #196. The existing water_purifier_coffee fixture (#107) turns
out to hit the same shape, so its golden drops the entity too.

Issue #195 (TP1X_REF_21K) needed no change: its diagnostics show zero
unbound hrefs and the model already routes to the refrigerator registry,
matching the maintainer's own comment on the issue.
2026-07-29 23:23:56 +00:00
Marc Billow 1053ae421b Merge pull request #202 from firstof9/fix/fan-zerodivision-issue-201
fix(fan): fall back to settableMin/MaxFanSpeed when supportedFanSpeed is omitted (#201)
2026-07-29 18:06:41 -05:00
Marc Billow 9e85395b44 rename: unit/sub-unit -> subdevice, matching OCF terminology
"Unit"/"sub-unit" from #199's multi-indoor-device support wasn't OCF
idiomatic -- OCF calls each component of a composite device a
"subdevice" (see subdeviceIdList), so rename SubUnit -> Subdevice
throughout: the registry module, coordinator state, BoundEntity's
subdevice field, diagnostics keys (subdevices/subdevices_skipped/
subdevice_probes), entity unique_id prefixes (unit1_/sub_<uuid>_ ->
subdevice1_/subdevice_<uuid>_), device-name fallback labels, golden
fixtures, tests, README, and the adding-device-support skill.

Breaking change to entity unique_ids and diagnostics keys, acceptable
since this hasn't been released yet.
2026-07-29 22:57:11 +00:00
firstof9@gmail.com bc667e486c fix(fan): fall back to settableMin/MaxFanSpeed when supportedFanSpeed is omitted (#201)
Fixes ZeroDivisionError in fan platform when supportedFanSpeed is missing on microwave vent fans (e.g. ME8000T).
2026-07-29 15:50:15 -07:00
Marc Billow 9442248c20 Merge origin/main into multi-device sub-unit support
Conflict was purely additive: both sides appended golden-regression
tests at the same point in the file, and each side's last test shared
the single trailing assert block. Kept every test from both sides, each
with its own copy of that assert.

One real semantic merge on top of that. #136 (on main) remodelled the
legacy ARTIK051 board's beep from a buzzer_volume Number to a beep
Switch, and HJcom's ARTIK051_DONGLE_FAC_18K is exactly that board
generation (is_legacy_board -> True), so its golden -- written before
that change existed -- still expected buzzer_volume. Regenerated it:
buzzer_volume/unit1_buzzer_volume -> beep/unit1_beep on the master and
the second indoor unit alike, with nothing else moving and still no
unit2_ keys. That is main's intended behavior reaching the sub-unit for
free, which is the point of binding siblings through the same registry.

967 passing. Re-ran the corpus-wide unique_id audit over all 57
fixtures (main added five this branch had never seen): no collisions
within a platform.
2026-07-29 19:40:32 +00:00