Compare commits

...
Author SHA1 Message Date
Marc Billow cc570533a0 Merge pull request #149 from mbillow/claude/ticket-127-device-coverage-xsb0m4
Distinguish not-yet-fetched stub reps from confirmed-empty ones (issue #127)
2026-07-27 22:25:38 -05:00
Marc Billow 6239706065 Keep entity._is_included's default gate permissive on confirmed-empty reps
Opus review of #149 caught that swapping is_stub_rep(rep) in for the
default field-presence gate (not just the 9 hand-audited exists_fn call
sites) was too broad: it silently excludes entities on ANY resource whose
normal, valid state includes reporting {} -- /alarms/vs/0's {} is
fridge.py's documented no-alarm state, not an absence signal, and it's not
the only one (job_beginning_status, diagnosis_status, sabbath_mode,
defrost_delay, ice_maker_enabled all lost entities on real fixtures under
the broader change). That's the opposite of #127's fix: a real fridge
would have dropped its alarm sensor on first-poll timing, not just its
phantom energy sensors.

Restored the default gate to include on either a stub or a genuinely-empty
rep -- verified byte-identical to the pre-#149 baseline across all 40
fixtures, apart from the 9 deliberately-audited exists_fn sites (energy
meter, self-check error, cooktop burner, range-hood auto-op), which are
unaffected and still fix #127. Added tests/test_entity.py exercising
_is_included directly (previously untested) and fixed two now-stale
"not rep" doc references the review also flagged.
2026-07-28 03:18:23 +00:00
Marc Billow 33786ad584 Distinguish not-yet-fetched stub reps from confirmed-empty ones (issue #127)
parse_device0_batch used to collapse /device/0's {"href": "..."} "no data
yet" marker into a plain {}, indistinguishable from a resource the device
had actually polled and confirmed empty. Every exists_fn using the "not
rep or ..." stub carve-out (and entity._is_included's default field-gate)
then treated both the same way, creating phantom always-"unknown" entities
for any resource a model simply doesn't support (e.g. GSzabados's fridge's
/energy/consumption/vs/0).

is_stub_rep() now recognizes only the literal {"href": ...} marker as a
stub; a genuine {} is treated as the device's real (if empty) answer and
gates the entity off like any other missing field. Updated the energy
meter, self-check error, cooktop burner, and range-hood auto-operation
exists_fn call sites, plus three golden fixtures that had baked the
phantom-entity behavior in as "expected".
2026-07-28 02:57:30 +00:00
Marc Billow e60fdf26d2 Merge pull request #148 from mbillow/claude/triage-issues-144-147-yv80ab
Fix water-purifier hot-water lock mislabel, add range-hood after-run support
2026-07-27 21:31:31 -05:00
Marc Billow 9011f84787 Model after_run_progress as a percentage, fix Dutch after-run-progress name
runningProgress's own field name states its domain, so restore unit='%' and
state_class='measurement' rather than leaving it an opaque passthrough --
that hedge made sense for activationState (no supported-values list, no
write contract to invent) but not here, where the name itself is the
evidence.

"Nadraaien voortgang" also wasn't idiomatic Dutch (nouns don't stack that
way); "Voortgang nadraaien" matches how the rest of the catalog compounds
these names.
2026-07-28 02:29:01 +00:00
Marc Billow 0640ac3477 Fix hotwater_lock key-collision hazard, address Opus review of triage fixes
An Opus review of the previous commit found that giving the switchHotwater
fallback and LOCK.hotwater_lock the same key introduced a real bug:
adapter.flatten() (the source of coordinator.data, which every switch's
is_on reads) only ever honours exists_fn, never entity.py's implicit
own-field-presence default that gates plain registration. With only one
side of the pair gated, both descriptors still wrote the same key into the
flattened state dict, and whichever was processed last -- decided by
device-reported href order, not correctness -- silently won. Reproduced
with the existing coffee fixture: reversing resource order flipped
hotwater_lock from correct (False) to a stuck True.

Fixed by gating both sides symmetrically via a shared tri-state helper that
also treats an unfetched /status/lock/vs/0 stub as "outcome pending" rather
than "confirmed absent" -- otherwise the stub window let both descriptors
pass exists_fn at once, which would have registered two switch entities
with the same unique_id. The fallback also re-asserts its own field's
presence, a check it used to get for free before it shared LOCK's key.

Also addresses two smaller findings from the same review, both in the
range-hood after-run capability (#147): runningProgress's unit='%' was a
guess from a single "0" sample with no supported-values/range field to
confirm the domain -- inconsistent with treating activationState as
read-only for the same "don't guess" reason -- so it's now a bare
passthrough sensor; and entity_category='diagnostic' was dropped from the
two read entities since after-run is a feature the user actively watches
and cancels via the (correctly uncategorized) button, not passive
diagnostics.
2026-07-28 02:25:42 +00:00
Marc Billow b47dabeb31 Merge pull request #143 from mbillow/claude/microwave-fanspeed-coverage-nmvc86
Microwave vent fan and kimchi-refrigerator compartment coverage (#137, #142, #26)
2026-07-27 21:13:03 -05:00
Marc Billow cc3ce12aa4 Fix range hood fan power targeting and kimchi mode write validation
- _speed_zero_is_off now keys off the hood resource's own
  settableMinFanSpeed/supportedFanSpeed fields instead of asking whether
  the device has any power resource at all, so a combi appliance's cavity
  /power/0 can no longer be toggled off by turning off just the vent fan.
- async_turn_on() no longer resets an already-running fan to its lowest
  speed when called without a percentage.
- _has_separate_power() reads through the O(1) resource cache instead of
  copying the full resource snapshot on every property access.
- _kimchi_mode_write rejects values the compartment didn't advertise in
  supportMode instead of writing them blind.
- kimchi_ripening_status no longer lowercases its value, since it has no
  enum catalog entry to translate the lowercased token back through.
- Documented why KIMCHI_DOOR_GENERIC isn't deduped against the /doors/vs/0
  aggregate fallback on the one fixture that reports both.

Adds regression tests for the combi-appliance power targeting, the
already-on turn_on no-op, kimchi mode write validation, and a kimchi
select display/write casing round-trip; a translation-coverage guard for
kimchi_zone_mode codes mirroring the existing AC preset one.
2026-07-28 02:10:01 +00:00
Marc Billow 5055d6bb72 Fix water-purifier hot-water lock mislabel, add range-hood after-run support
Water purifier (#144, #145): /favorite/hotwater/vs/0's switchHotwater field
is a Locked/Unlocked hot-water lock, not a "favorite enabled" flag. It's the
same lock as LOCK.hotwater_lock, just surfaced through this href on boards
that don't populate /status/lock/vs/0's hotwaterLock -- the two now share
the hotwater_lock key/translation, gated so only one is ever active.

Range hood (#147): binds /afterrun/vs/0 (after-run activation state,
progress, and a cancel button), clearing the last unbound href for
AHD-WW-TP1-22-COMMON.
2026-07-28 02:00:57 +00:00
Marc Billow 265d94eded Add kimchi-refrigerator compartment coverage (issue #26)
TP2X_REF_20K-class 3-compartment kimchi refrigerators report each
compartment's storage mode and ripening status/timer on
/status/kimchi/<slot>/vs/0, plus a top-compartment door sensor on
/kimchidoors/top/vs/0 -- all previously unbound. Bind them as pattern
capabilities (fridge.KIMCHI_ZONE, fridge.KIMCHI_DOOR_GENERIC), deriving
the per-compartment entity key and display name from the href's
top/middle/bottom segment, the same way DOOR_GENERIC/TEMP_CURRENT_GENERIC
already do.

Storage-mode option labels were translated directly from the reporter's
own SmartThings app screenshots rather than guessed from the raw device
codes or their English paraphrase, confirming the on-screen option order
matches supportMode's array order (including the freezer triplet's
-19/-21/-17°C -> Standard/Strong/Weak mapping).

Also tighten FLEX_ZONE's exists_fn: this device's /mode/vs/0 also
populates modes/supportedOptions, but with a token shape that never
overlaps (a "_[n]:[n]" suffix supportedOptions carries that modes never
repeats), so the existing "supportedOptions is nonempty" check let the
entity bind anyway and get stuck permanently on "unknown". Requiring an
actual resolvable value keeps it working for the RF9000/Bespoke-class
fridges it was built for while leaving it absent here.
2026-07-28 00:35:21 +00:00
Marc Billow e9281aaead Bind microwave built-in vent fan's /hood/fanspeed/vs/0 (issues #137, #142)
Combi microwave units report their vent fan on the same resource shape a
standalone range hood uses, so reuse range_hood.HOOD_FAN directly in the
microwave registry. Unlike a standalone hood, this board has no sibling
/power/0 or /power/vs/0 resource, so LocalThingsRangeHoodFan now falls
back to treating fan speed 0 as the off state when no separate power
resource is present. Also gate HOOD_FAN's automatic_operation sensor on
field presence, since this board doesn't report it.
2026-07-28 00:18:38 +00:00
Marc Billow c19800ac00 Merge pull request #135 from QuiteYellow/fix/stale-dtls-session-fixed-source-port
Bind a fixed DTLS source port per device to evict stale sessions
2026-07-27 18:40:36 -05:00
Marc Billow ed5e8e57c8 Merge pull request #140 from mbillow/claude/v0-13-0-issue-triage-9zfjbj
Split microwaves into their own device type instead of the oven registry
2026-07-27 17:10:10 -05:00
Marc Billow f063666291 Merge pull request #139 from mbillow/claude/air-purifier-fan-controls-ananzq
Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)
2026-07-27 17:06:59 -05:00
Marc Billow 5af9d951c6 Simplify README microwave row label 2026-07-27 22:05:54 +00:00
Marc Billow a1f14cd633 Split microwaves into their own device type instead of the oven registry
Microwaves (combi and plain) were routed onto the oven registry (issue
#121), which meant entities carried oven-flavored keys (oven_state,
oven_mode, oven_setpoint) and inherited oven-specific behavior that's
wrong for this family: a 30-270C setpoint range instead of this family's
actual 40-200C, a cooking-mode list missing MicroWave/MicroWaveGrill/
MicroWaveConvection/KeepWarm entirely, and a lamp switch that read/wrote
the oven's 'UpperLamp' option token instead of this family's 'Lamp' token.

Adds a microwave device type (by_type/microwave.py,
capabilities/microwave.py) that reuses the oven board family's shared
operational-state/door/connected/recipe-cook capabilities but defines its
own cooking-mode, setpoint, and cavity capabilities with the corrected
bounds/vocabulary, plus a new power_level sensor for the cavity's Watt
setting that was previously unexposed.
2026-07-27 22:05:54 +00:00
Marc Billow 2be742489b Fix airflow fan power-href preference and unique_id collision risk
Opus review of the previous commit caught two real bugs. The airflow fan's
power writes preferred /power/vs/0, copied from the TP1X fan class -- but
that order is only harmless there because TP1X never reports /power/0 at
all. This family's dumps carry both hrefs, and the power_switch entity is
unconditionally bound to /power/0 when present, so the fan was writing to
a different resource than power_switch reads/writes, leaving the two
entities disagreeing until the next poll. Flipped to prefer /power/0,
matching the range hood's fan and common.POWER_GENERIC.

Also renamed the new FanDesc's key from 'fan' to 'airflow_fan': BoundEntity
unique_ids are derived from key alone, not href, so it collided with
air_purifier.FAN's own 'fan' key on the (currently unobserved, but
unenforced) possibility of a board reporting both.

Added a platform-level test file covering the power-href preference and
percentage<->speed-code mapping, mirroring test_range_hood_fan.py's harness.
2026-07-27 21:48:23 +00:00
Marc Billow d4583b3240 Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)
/airflow/0's speed was left read-only because the first round of diagnostics
wasn't conclusive (0 for both Auto and High, 3 for Low/Medium and Sleep) --
likely because all five dumps were captured within about a minute of each
other, faster than this integration's own poll cycle could settle each
change. A second round, captured 60-90s apart per setting on two independent
units, confirmed a clean monotonic 0-4 mapping across Auto/Sleep/Low/Medium/
High instead.

Builds an ordered-speed fan off that confirmed range, the same SET_SPEED
shape as the range hood's fan -- this board never self-reports a
supportedModes-style label list, so there's no named-preset table to
preserve, just percentage steps over the raw code. /airflow/vs/0's vendor
speedLevel stays a read-only fallback since it was unreliable in that same
second round.
2026-07-27 21:32:44 +00:00
Jack Nagy 0ebcfb00ff fix: bind a fixed DTLS source port per device to evict stale sessions
When HA restarts without a clean DTLS close_notify (crash, host reboot),
the appliance keeps an orphaned DTLS association keyed to the client's
(IP, source port). Reconnecting from a fresh ephemeral port looks like a
new peer, so the device holds the orphan until its own timer reaps it,
which is 5 to 15 min on always-on appliances (fridges), during which the
new session's first reads hang. This is the root cause behind the repeated
"DTLS handshake timeout" reconnect storms on always-on devices (#119).

Bind a deterministic source port per device so every reconnect re-handshakes
over the same 5-tuple, which the device must treat as a rebooted peer and
evict the old association for (RFC 6347 §4.2.8). Recovery drops from a
device-timer wait to a single handshake.

The port must be stable across restarts and unique per device on the HA host
(the library socket is unconnected, so a shared source port would cross-
deliver datagrams). _local_source_port() uses the host's last IPv4 octet as
the offset from DTLS_LOCAL_PORT_BASE (unique on a /24), with a CRC32 fallback
for non-IPv4 hosts.

Requires smartthings-local >= 0.1.1, which adds DtlsCoapSession(local_port=).
The fix is backwards compatible upstream: local_port defaults to None
(previous ephemeral-port behaviour).

Root-caused and verified upstream in QuiteYellow/SmartThings-Local#14
(bench-verified on oven + dryer, field-verified on an always-on fridge
across repeated restarts).
2026-07-27 19:17:39 +01:00
Marc Billow 7c68d478af Bump version to 0.13.0 2026-07-27 14:54:26 +00:00
Marc Billow 3c15ca810b Merge pull request #132 from mbillow/claude/triage-issues-111-127-on5l50
Triage issues #111-#131: AC/oven/air-purifier detection fixes, new vacuum-station type, reconnect log noise
2026-07-27 09:46:11 -05:00
Marc Billow e9eb38740d Deduplicate ISO-timestamp parsing and document the new device type (review follow-up, issue #131)
- vacuum_station._parse_iso_utc was a verbatim copy of
  water_purifier._parse_iso_utc; promoted to common.parse_iso_utc and
  pointed both families at it. Also made it tzinfo-aware rather than
  unconditionally overwriting with UTC -- harmless today since every
  dump seen is a bare or Z-suffixed UTC timestamp, but a board that
  ever emits a real offset would otherwise have it silently clobbered.
- Added the new vacuum_station type to the README's supported-appliance
  table, and noted that combi microwaves route through the oven
  registry.
2026-07-27 14:43:02 +00:00
Marc Billow f37c9ec4ef Fix air-purifier fan power write and silent preset-mode rejection (review follow-up, issue #130)
- The fan's power write hardcoded /power/vs/0 while is_on already read
  /power/0 as a fallback -- a board reporting only the OCF resource
  would show correct state but silently no-op on every turn-on/off.
  Mirrors LocalThingsRangeHoodFan's existing _power_payload pattern:
  target whichever power href the board actually reports.
- async_set_preset_mode fell off the loop silently on an unmatched
  mode with no log and no error, unlike the rest of this codebase's
  write-rejection handling. Logs a warning now.
- Deduplicated HEPA_FILTER's usage-percent calculation, which was an
  inline reimplementation of airconditioner._filter_usage_percent;
  promoted the shared logic to common.filter_usage_percent and pointed
  both families at it.
- Gave air_purifier.SOUND_MODE its own translation_key instead of
  defaulting to the same catalog entry laundry.SOUND_MODE uses. That
  entry's state table is {voice, tone, mute}; this board's is
  {mute, buzzer} -- sharing it left 'buzzer' with no label.
2026-07-27 14:42:34 +00:00
Marc Billow d26e7b957b Fix unreachable reconnect-warning threshold (review follow-up, issue #119)
The 60s/5-reconnect window from the original fix could never actually
fire: consecutive reconnect attempts are never closer together than one
summary poll interval (30s) plus the 5s reconnect pause, so at most ~2
timestamps can ever land inside a 60s window regardless of how unhealthy
the connection is. That silently downgraded every reconnect to INFO
permanently, including the persistently-broken case the change was
supposed to still surface at WARNING.

Widen to a 300s window with a threshold of 3, which is reachable under
sustained failures and still a reasonable proxy for the README's
"actually broken" case.
2026-07-27 14:41:43 +00:00
Marc Billow b31f4f0c40 Merge pull request #128 from pedroperosin/fix/climate-set-temperature-hvac-mode
Honour hvac_mode in the AC climate set_temperature
2026-07-27 09:30:19 -05:00
Marc Billow 8b44fd5710 Add device support for the stick-vacuum clean/auto-empty station (issue #131)
A-VSKR-TP1-22-VS9500AL connects successfully but its dump shows no
vacuum-body state at all -- no suction level, no battery, no cleaning
mode -- only the clean/auto-empty station's own dustbag, dustbin
auto-empty settings, and UV-C sanitizing-cycle status. This strongly
suggests the WiFi/DTLS module lives in the station, not the handheld
stick, so the station is the only "device" this integration's local
API can reach at all.

New vacuum_station device type (these hrefs share nothing with any
existing family, so there's no shared-href ambiguity to resolve
against another type) routed via a new '-VSKR-' modelNum fallback.
Binds with zero unbound hrefs: dust-bag full/usage sensors, auto-empty
and dustbin auto-close switches, a discharging-time select, and
clean-station status including UV-C intensive mode, operation time,
and finished/emitted timestamps. A couple of fields with unconfirmed
exact semantics (stick_status, dustbag_usage's unit) are exposed as
plain diagnostic values rather than an asserted binary/percentage
meaning.
2026-07-27 14:11:06 +00:00
Marc Billow 4e1eb7d03d Add fan-mode control for TP1X_DA-AC-AIR air purifiers (issue #130)
This newer board family reports fan modes (Smart/Max/Mid/WindFree/Sleep)
directly on /mode/vs/0's top-level modes/supportedModes fields, unlike
the older ARTIK051_TVTL family this registry already supported, which
packs everything into an options[] array with no usable fan-speed
selector at all (see the module docstring's Comode_Off finding). Both
board generations share the /mode/vs/0 href, so the existing MODE
capability and a new FAN capability are discriminated by a match_fn
checking for the top-level supportedModes field, rather than adding a
new device type.

The fan entity only exposes PRESET_MODE, not an ordered percentage --
WindFree/Smart/Sleep are named behaviors, not "faster/slower" positions
relative to Max/Mid, matching how the AC family's own named convenient
modes are modeled as a preset rather than a speed number.

Also picked up the rest of this board's previously-unbound hrefs while
in there (display, HEPA filter, panel status, pet-filter mode, sound
settings), reusing airconditioner.DISPLAY_LIGHT and
airconditioner.MUTE_ONCE for the two hrefs identical to the shared
DA-AC- board family, since the "incomplete capability coverage" repair
was firing on more than just the fan gap the issue described.
2026-07-27 14:08:32 +00:00
Marc Billow e44fef7085 Route combi microwaves onto the existing oven registry (issue #121)
TP1X_DA-KS-MICROWAVE-01041 (MW7300B) reports no oneUiVersion and an
unrecognized consumer token, so it fell back to 'unknown' and only got
common capabilities. It shares the same '/oven/vs/0' cavity resource
and '/mode/vs/0' cook-mode shape (Convection/AirFryer/Grill/MicroWave*)
as the wall oven already supported, so this reuses that registry via a
new '-MICROWAVE-' modelNum fallback rather than adding a new device
type. The only href it didn't already cover was /recipe/cook/vs/0, an
empty quick-recipe-display blob bound with no entity per the 'don't
guess' rule.
2026-07-27 13:41:36 +00:00
Marc Billow 6f10a3b796 Support 2-axis wind oscillation and overload-protection status on newer WindFree boards (issue #126)
Newer TP1X_DA-AC-RAC-01011_0000 firmware (Bespoke AI WindFree Deluxe,
AR60H10D1JWNME) drops /wind/direction/vs/0 entirely and reports swing
via a separate vertical/horizontal Swing|Fix pair on
/wind/oscillation/vs/0 instead, which left swing_mode/swing_modes
silently empty and the href unbound. climate.py now falls back to the
oscillation resource when /wind/direction/vs/0 is absent, mapping the
same off/vertical/horizontal/both vocabulary the existing swing control
already uses.

Also binds the board's /anomalyload/vs/0 overload-response resource as
read-only diagnostic sensors (operation state + mode) -- the same
"don't guess" precedent as the existing CURRENT_LIMIT capability, since
nothing in the dump confirms the exact behavioral difference between
its 'Alarm' and 'PowerSaving' modes or whether toggling it is safe on
live HVAC hardware.

Most of the other gaps this issue reported (Fan-only mode, WindFree
preset labels, target-temperature channel selection, power on/off via
the vendor resource) turned out to already be fixed by the just-merged
cool-only global RAC work.
2026-07-27 13:41:04 +00:00
Marc Billow 2c8a765036 Downgrade a lone poll-failure reconnect to info (issue #119)
Samsung's firmware occasionally drops the DTLS session briefly --
normal appliance-side behavior per the README's "Known device
behavior" section -- so the coordinator recovering from that on its
own doesn't need a WARNING. Only escalate once reconnects pile up
within a trailing 60s window (5+), matching the README's own "more
than a handful per minute" definition of an actually broken
connection.
2026-07-27 13:40:32 +00:00
Marc Billow f62b4aeec8 Detect ARA-WW-TP1-22-COMMON wall-mount RACs as airconditioner (issues #115, #116, #117, #120)
AR10/13/18BYEAAWKNME report no oneUiVersion and no '_RAC_'/'-RAC-'
token at all, so for_device_by_model() fell through to 'unknown' and
every href went uncovered. The board carries the same TP1X-class
resource surface as every other room AC already supported (mode/
convenient/wind/temperature/power/filter/humidity), so this reuses the
existing airconditioner registry via a new 'ARA-WW-' modelNum fallback
rather than adding a new device type -- confirmed against all four
reporters' dumps binding cleanly with zero unbound hrefs.
2026-07-27 13:40:12 +00:00
Marc Billow 46dd91ce32 Add regression coverage for NE8300D range (issue #112)
TP1X_DA-KS-RANGE-0102X already resolves via the '-RANGE-' modelNum
fallback and /cooktopmonitoring/vs/0 already binds through
range.COOKTOP_MONITORING, so this model binds with zero unbound hrefs
today -- add a fixture to lock that in.
2026-07-27 13:39:51 +00:00
Marc Billow 085e80c92c Add regression coverage for WA55A7700AV washer (issue #111)
The DA_WM_TP1_21_COMMON board family already routes through the 'WA'
consumer-model-prefix fallback and binds cleanly against the washer
registry with zero unbound hrefs, but no fixture locked that in for
this specific board generation -- add one.
2026-07-27 13:39:30 +00:00
Pedro a9f21982e7 Honour hvac_mode in the AC climate set_temperature
HA's set_temperature service forwards an optional hvac_mode to the entity, and
the entity is expected to apply it. The AC climate entity ignored it and only
wrote the setpoint, so a set_temperature call carrying hvac_mode (e.g. a
dashboard "turn on to Auto 24" button) set the temperature but never changed the
mode or powered the unit on. Apply the mode first -- which powers the unit on
when it was off -- then the setpoint.
2026-07-27 09:57:31 -03:00
Marc Billow ef23f5ec32 Merge pull request #114 from mbillow/claude/pr91-finish
Add cool-only global RAC support: WindFree, Auto mode, and display light
2026-07-27 00:35:48 -05:00
Marc Billow 5547c401ed Address independent review findings on the RAC finish-up branch
- Pin the FAN_ONLY reverse-write fallback to 'Wind' (the original single
  spelling) instead of letting it silently flip to 'Fan' just because
  'Fan' was added second to the dict -- _device_code_for_hvac() resolves
  the code from a unit's own supportedModes first, so this dict is only
  a fallback for a unit reporting none at all, and that fallback
  shouldn't change behavior as an unintended side effect of insertion
  order.
- Add direct tests for _preset_to_ha() (pure function, previously
  untested) and the FAN_ONLY fallback pin.
- Cross-reference the AC family's inverted Light_On/Light_Off polarity
  against air_purifier.py's plain-polarity use of the same token name on
  the same resource name, so a future refactor doesn't assume they're
  the same thing.
- Fix a one-column continuation-line misalignment and a stale PR-number
  reference in a comment.
2026-07-27 05:11:58 +00:00
Marc Billow fa8f1b8675 Add cool-only global RAC support: WindFree, Auto mode, display light
Finishes PR #91's contribution (pedroperosin) with the requested review
changes applied, on our own branch:

- Preset resolution is now fully dynamic, read from each unit's own
  /mode/convenient/vs/0 supportedModes instead of a static per-model
  table -- any board's convenient modes (including WindFree's Nano/
  NanoSleep) surface without code changes. Unlabelled codes across
  existing fixtures (longwind, motionindirect, motiondirect, drycomfort)
  plus the two new WindFree ones are added to en.json/nl.json.
- 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are
  single-setpoint "device decides" units, not two-setpoint heat+cool
  ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling;
  a new _device_code_for_hvac() picks the code from the unit's own
  supportedModes since the flat map can't disambiguate two device codes
  mapping to one HA value.
- Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the
  existing '_RAC_') for cool-only global RAC variants whose
  /otninformation/vs/0 ships no swVersionInfo block.
- Adds a display_light switch sourced from /mode/vs/0's opaque options
  blob (inverted Light_On/Light_Off token) for boards with no dedicated
  /light/vs/0 switch.

Write-path behavioural change (touches the path iterated on across
#9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of
the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on
several known AC boards, so the previous OCF-first read/write pair could
report and act on stale state -- consistent with #53's "can turn on but
not off". Target temperature now picks its channel (OCF pair vs. vendor
items[]) based on which the unit actually reports, reading and writing
the same one.

The vendor temperature write and the new display-light write both carry
only the changed field(s), not the whole resource -- confirmed sufficient
on the wire, the device merges the rest itself. That requires the
coordinator's optimistic cache to do the same merge on the read side so a
setpoint change doesn't blank out current/min/max/unit for the settle
window: common.py gains merge_items_field() next to the existing
merge_options_field(), and async_send_command wires it in for any write
touching x.com.samsung.da.items.

New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC-
01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens
for boards that gain the new options-based switch. Regenerated against
current main rather than copied from the original PR, since those
goldens had already shifted (current_temperature_c/humidity from issue
#75).
2026-07-27 05:00:06 +00:00
Marc Billow af00c2b938 Merge pull request #110 from mbillow/claude/device-support-issue-107-coffee
Add coffee-maker capabilities to the water purifier registry (issue #107)
2026-07-26 23:40:03 -05:00
Marc Billow 1177f0ed64 Merge pull request #109 from mbillow/claude/device-support-issue-106-wa-washer
Add WA (top-load washer) consumer-model prefix (issue #106)
2026-07-26 23:38:19 -05:00
Marc Billow 35775c3d4a Add coffee-maker capabilities to the water purifier registry (issue #107)
Some TP2X_WATERPURIFIER_20K units are coffee-capable and expose five
resources issue #90's original dump never had:
/favorite/coffee/vs/0, /favorite/hotwater/vs/0,
/brand/recipe/info/vs/0, /coffee/custom/recipe/vs/0,
/recipe/coffee/vs/0, and /recipe/coffee/deletion/vs/0.

Adds FAVORITE_HOTWATER (a switch + select pair on
/favorite/hotwater/vs/0, mirroring the existing FAVORITE_CAPACITY
pattern) and COFFEE (a switch + status sensor on
/favorite/coffee/vs/0). The remaining four hrefs are static
capability-advertisement blobs or empty on every dump seen so far --
no live "current recipe" or "current custom slot" field to expose --
so they're added to the ignored coverage list per the 'don't guess'
rule rather than modeled speculatively.

Confirmed against the issue #107 diagnostics dump with zero unbound
hrefs.
2026-07-27 04:19:19 +00:00
Marc Billow 8ac1d11d17 Add WA (top-load washer) consumer-model prefix (issue #106)
WA8000T reports no oneUiVersion and used the 'WA' consumer-model
prefix, unmapped in _CONSUMER_PREFIX_TO_KEY (only WW/WD/WF/WV were
covered), so it fell into the unknown-device-type fallback.

Adding a bare 'WA' entry collided with the unrelated '_WAC_' (Window
Air Conditioner, issue #87) board-family token: some devices report
description == modelNum, so 'WAC' shows up as its own description
segment and 'WAC'[:2] == 'WA' matched the new washer prefix before the
more specific '_WAC_' modelNum check ever ran. Fixed by reordering
for_device_by_model() to check board-family modelNum tokens first and
the fuzzier 2-letter consumer-model-prefix scan only as a fallback,
rather than patching the prefix matching itself (an earlier attempt --
requiring a digit immediately after the prefix -- broke issue #79's
real DVE50A8800 case, which has no digit there either). Added a
regression test pinning the WAC/WA disambiguation directly.

Confirmed against the issue #106 diagnostics dump with zero unbound
hrefs.
2026-07-27 04:15:08 +00:00
Marc Billow b3a9192088 Merge pull request #98 from mbillow/claude/device-support-issue-86-cooktop
Add standalone induction-cooktop support (issue #86)
2026-07-26 23:04:51 -05:00
Marc Billow 634f367e96 Merge remote-tracking branch 'origin/main' into claude/device-support-issue-86-cooktop
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
2026-07-27 04:04:19 +00:00
Marc Billow 482e238a7a Merge pull request #102 from mbillow/claude/device-support-issue-77-freezer
Device support issue #77: freezer
2026-07-26 23:03:59 -05:00
Marc Billow f31cee206b Merge remote-tracking branch 'origin/main' into claude/device-support-issue-77-freezer
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
#	tests/test_by_type.py
2026-07-27 04:03:38 +00:00
Marc Billow 14b5a7cb68 Merge pull request #96 from mbillow/claude/device-support-issue-88-dehumidifier
Add device support for Samsung dehumidifiers (issue #88)
2026-07-26 23:00:33 -05:00
Marc Billow 8628ae6864 Merge remote-tracking branch 'origin/main' into claude/device-support-issue-86-cooktop
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
#	custom_components/localthings/translations/en.json
#	custom_components/localthings/translations/nl.json
2026-07-27 04:00:15 +00:00
Marc Billow 38263eaa72 Merge remote-tracking branch 'origin/main' into claude/device-support-issue-88-dehumidifier
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
#	tests/test_by_type.py
#	tests/test_golden_regression.py
2026-07-27 03:58:53 +00:00
Marc Billow ff6e1ecff4 Rename gas cooktop registry's display name to avoid induction_cooktop confusion
Renames DeviceRegistry.name from 'cooktop' to 'gas_cooktop' for the
NA9300K-class gas-cooktop registry (PR #23), so diagnostics/device-info
labels no longer collide with the unrelated induction_cooktop family
(issue #86) -- two different OCF surfaces that happen to share the
English word "cooktop".

Safe rename: _REGISTRY_BY_KEY's 'cooktop' lookup key is unchanged, so
all three existing detection paths (oneUiVersion "Cooktop" exact
match, the legacy ARTIK051 modelNum rule, and the resource-signature
fallback) keep routing real devices exactly as before. Entity
unique_ids are built from device serial + entity key, not registry
name, so existing entities are unaffected. Only the DeviceInfo.name
and diagnostics device_type strings change, both cosmetic.
2026-07-27 03:56:32 +00:00
Marc Billow 9ccaa3f01d Merge pull request #95 from mbillow/claude/device-support-issue-90-water-purifier
Add device support for Samsung water purifiers (issue #90)
2026-07-26 22:53:40 -05:00
Marc Billow 78f1bb0f92 Fix unclosed PROBE_STATUS capability from a bad merge conflict resolution
The merge of main into this branch dropped PROBE_STATUS's closing
),\n) and glued issue #74's COOKTOP_MONITORING addition directly onto
its entities tuple, leaving an unclosed paren (SyntaxError on import,
breaking Pytest and Hassfest CI). Restores the closing parens; no
functional change.
2026-07-27 03:46:55 +00:00
Marc Billow 5e60f9b953 Fix stale Window AC golden fixture (current_temperature_c, humidity)
PR #75 (WindFree AC) added CURRENT_TEMPERATURE/HUMIDITY capabilities
to the shared airconditioner registry, which every AC device picks up
-- including the Window AC from PR #87. Both branches built their
golden fixtures independently against their own base commit before
either landed, so neither saw the other's addition; once both merged,
the Window AC's fixture went stale. The two extra keys are real,
working sensors from #75's work, not a regression.
2026-07-27 03:45:32 +00:00
Marc Billow 3b0f4f8b66 Merge branch 'main' into claude/device-support-issue-90-water-purifier 2026-07-26 22:06:20 -05:00
Marc Billow 2aaaad71a8 Merge branch 'main' into claude/device-support-issue-88-dehumidifier 2026-07-26 22:05:24 -05:00
Marc Billow 4719e3aa80 Merge pull request #97 from mbillow/claude/device-support-issue-87-window-ac
Add device support for Bespoke Window AC (issue #87)
2026-07-26 22:03:36 -05:00
Marc Billow 84d73105cf Merge branch 'main' into claude/device-support-issue-86-cooktop 2026-07-26 21:58:21 -05:00
Marc Billow d0e03b026c Merge pull request #99 from mbillow/claude/device-support-issue-83-fridge-detection
Catch the 'Nothing(SVC)' placeholder serial in both fallback sites (i…
2026-07-26 21:55:33 -05:00
Marc Billow d2f0a5c976 Merge pull request #100 from mbillow/claude/device-support-issue-80-cycle-labels
Add confirmed washer/dryer cycle code labels (issue #80)
2026-07-26 21:53:21 -05:00
Marc Billow 48b34c9e31 Delete test_issue_80_cycle_codes_are_labelled
Removed test for issue 80 regarding cycle codes.
2026-07-26 21:53:06 -05:00
Marc Billow 0b6eda0cdc Merge branch 'main' into claude/device-support-issue-80-cycle-labels 2026-07-26 21:51:23 -05:00
Marc Billow 285d2de397 Merge pull request #101 from mbillow/claude/device-support-issue-79-dryer
Fix dryer detection when description pairs two model numbers (issue #79)
2026-07-26 21:45:12 -05:00
Marc Billow 8b45d8cbf6 Merge branch 'main' into claude/device-support-issue-77-freezer 2026-07-26 21:40:51 -05:00
Marc Billow f3b0ef4733 Merge pull request #103 from mbillow/claude/device-support-issue-75-windfree-ac
Add humidity/temperature sensors and horizontal swing for AC (issue #75)
2026-07-26 21:37:59 -05:00
Marc Billow d20d4e2158 Merge pull request #104 from mbillow/claude/device-support-issue-74-range
Add range/oven detection for boards missing /information/vs/0 (issue …
2026-07-26 21:33:25 -05:00
Marc Billow d321fe72cd Merge pull request #94 from mbillow/claude/device-support-issue-93-ac-modes
Device support issue 93: ac modes
2026-07-26 21:30:46 -05:00
Marc Billow 9b09f1aee3 Merge pull request #70 from vmvarga/feat/wd7000b-fridge-fixes
feat: laundry firmware-flag gating, fridge vendor temp writes, course…
2026-07-26 21:25:26 -05:00
Marc Billow 45931332d4 Rework AIComfort as an HVACMode.AUTO + preset overlay, add unmapped-mode warning (issue #93)
AIComfort isn't a distinct thermodynamic operation like Cool/Dry/Heat --
it's an AI-driven overlay on top of the device's own 'Auto' behavior,
confirmed by A-CAWW-TP2-20-COMMON reporting both 'Auto' and 'AIComfort'
as separate, mutually-exclusive entries in /mode/vs/0's supportedModes.
Modeled the idiomatic HA way instead of a flat _DEVICE_TO_HVAC entry:
hvac_mode reports AUTO and a new 'ai_comfort' preset carries the
distinction. Entered/left only via the preset (writes the primary mode
resource, not the convenient one) -- there's no dedicated HVACMode
value for it, so it's not offered in the hvac_mode dropdown directly.

Also adds a once-per-(href, code) warning log when a device-reported
mode has no entry in the relevant map, so a future gap like this one
surfaces in the log instead of silently vanishing -- the exact failure
mode issue #93 called out ("this class of gap is invisible without
diffing against supportedModes").
2026-07-27 02:01:51 +00:00
Marc Billow 8c3250b163 Map AC's AIComfort mode to HVACMode.AUTO (issue #93)
A-CAWW-TP2-20-COMMON (and likely other CAWW/TP2X-class boards) reports
'AIComfort' as a distinct entry in /mode/vs/0's supportedModes,
alongside 'Auto' (already mapped to HEAT_COOL). _read_modes() silently
drops any code missing from _DEVICE_TO_HVAC, so AIComfort was
unreachable -- one of HA's five other AC hvac_modes, unused by this
device family until now.

The other two gaps in issue #93 are already addressed elsewhere and
not duplicated here:
- Fan-only via the 'Fan' device code, and the WindFree/LongWind/
  NanoSleep preset codes, are covered by the still-open PR #91, which
  replaces the static preset table with a fully dynamic resolver over
  the device's own supportedModes.
- The 'Left_And_Right' -> horizontal swing mapping is already on the
  still-open claude/device-support-issue-75-windfree-ac branch.
2026-07-27 01:43:22 +00:00
Marc Billow d53459d047 Add device support for Samsung water purifiers (issue #90)
The TP2X_WATERPURIFIER_20K water purifier reports no oneUiVersion and
its modelNum/description don't match any consumer-prefix or existing
board-family token, so it fell into the unknown-device-type fallback
with only common capabilities. Add a new water_purifier registry,
routed via a 'WATERPURIFIER' modelNum/description fallback rule.

Models dispense settings (type/temperature/capacity/pouring status),
sterilize and filter status, favorite-capacity presets, and the three
water/buzzer locks. Per the adding-device-support skill's "never
hard-code the one dump's values" rule: dispense-capacity bounds and
step come live from the device's own desiredCapacityRange/
capacityResolution fields (range_field/step_fn), not a hardcoded
constant, and the hot-water-temperature control is a select over the
live supportedHotTemperatures list rather than a number with invented
bounds, since only a few discrete temperatures are selectable.

/mode/vs/0 and /automation/waterpurifier/vs/0 are left unmodeled: the
former carries an opaque wizard-workflow token with no coherent
current-value contract, the latter is a static support-flags blob with
no live setting to expose.

Confirmed against the issue #90 diagnostics dump with zero unbound
hrefs. Updates the README's supported-appliance-types table for the
new device type.
2026-07-27 01:40:05 +00:00
Marc Billow 89429039fb Add device support for Samsung dehumidifiers (issue #88)
The AY18CG7500GED dehumidifier (modelNum TP1X_DA_AC_DHM_01001_0000)
shares the DA_AC_ board family with the room-AC models but carries the
'_DHM_' token instead of '_RAC_'/'_PRAC_'/'_WAC_', so it fell into the
unknown-device-type fallback. Add a new dehumidifier registry, routed
via a '_DHM_' modelNum fallback rule, distinct from airconditioner
since target humidity (not temperature) is the primary control and
there's no climate composite.

Reuses airconditioner.py's AUTO_CLEAN/AIR_FILTER/MUTE_ONCE capabilities
directly (identical resource shapes on the shared board family). Adds
a new humidity sensor + target-humidity number pair and an
operating-mode select. Per the adding-device-support skill's
"never hard-code the one dump's values" rule, the target-humidity
number has no hardcoded min/max (falls back to HA's own 0-100 default
for a percentage field) and reads its step live from the device's own
`increment` field rather than a spec-sheet-derived constant. The
operating-mode select's options come live from supportedModes.

/mode/convenient/vs/0 is left unmodeled: only supportedModes is present
on this dump, with no live current-value field to confirm a read/write
contract.

Confirmed against the issue #88 diagnostics dump with zero unbound
hrefs. Updates the README's supported-appliance-types table for the
new device type.
2026-07-27 01:29:25 +00:00
Marc Billow b47eeaf7bc Add device support for Bespoke Window AC (issue #87)
The AW06C7155EWAZ window air conditioner (modelNum
TP1X_DA_AC_WAC_01001_0000) reports no oneUiVersion and uses the '_WAC_'
(Window Air Conditioner) modelNum token instead of the '_RAC_'/'_PRAC_'
tokens already handled by for_device_by_model. Add a fallback rule for
that token, routing it to the existing airconditioner registry.

The device's resource surface (mode/convenient/wind/temperature/power/
filter/humidity) is already fully modeled by the airconditioner
capability set, so this is purely a detection-routing fix -- confirmed
against the issue #87 diagnostics dump with zero unbound hrefs.
2026-07-27 01:17:45 +00:00
Marc Billow a453dc9ece Add standalone induction-cooktop support (issue #86)
TP1X_DA-KS-COOKTOP-01011 (NV8500T-/KO4) is the same board family and
/cooktop/status/vs/0 resource shape as issue #44's range combo, minus
the oven -- but its modelNum uses the hyphenated '-COOKTOP-' token,
which for_device_by_model's existing '_COOKTOP' check (underscore-
delimited, matching the unrelated NA9300K gas-cooktop family in
cooktop.py) doesn't match. The device fell back to 'unknown' with only
energy/alarms from the global fallback.

Add the hyphenated token check, routing to a new 'induction_cooktop'
registry (by_type/induction_cooktop.py) that reuses range.py's
COOKTOP_STATUS/COOKTOP_SPEC/COOKTOP_SAFETY/PROBE_STATUS and
cooktop.PAIRED_HOOD_STATUS wholesale rather than pulling in range.py's
oven capabilities, which this device has no hrefs for at all.

Along the way, three fields the reporter asked for turned out to be
gaps in the shared range.py capability itself, not just missing
routing -- also present (and previously unmodeled) on issue #44's
original combo-range dump:
- /cooktop/status/vs/0's own `power` and `childLock` fields (distinct
  from common.POWER's /power/0 or /power/vs/0, which a combo range
  additionally carries for the whole appliance) -- childLock gets a
  write_fn (a safe lock toggle, direct single-field PUT), power stays
  read-only (no live device to confirm a remote write wouldn't leave a
  burner active unattended).
- Each burner's `panDetection` field.

New: a Bluetooth meat-probe capability for /bluetooth/probe/status/vs/0
(read-only -- connection, battery, current/target temperature), and
/cooktop/recipe/status/vs/0 is ignored (every field empty on this idle
dump, same treatment as the microwave family's /recipe/cook/vs/0).

Regenerates the range golden fixture (gains cooktop_power/
cooktop_child_lock/burner_N_pan_detected) and adds a dedicated fixture
for the standalone cooktop.
2026-07-27 01:12:16 +00:00
Marc Billow 2c9fda3db1 Catch the 'Nothing(SVC)' placeholder serial in both fallback sites (issue #83)
The ARTIK051_DONGLE_REF firmware family reports the literal string
"Nothing(SVC)" as serialNum on every unit -- non-empty, so the existing
`if not serial` checks in config_flow.py's _probe_and_validate and
coordinator.py's _run_discovery don't catch it. Two such appliances on
one install (a fridge and a freezer, each its own dongle) then collide:
config_flow gives both the same unique_id and rejects the second as
"already configured" (bug 2), and even once that's worked around,
device_serial feeds every entity's unique_id too, so the second
appliance's entities get silently dropped with "does not generate
unique IDs" log lines (bug 4).

Add _is_placeholder_serial (duplicated in both modules rather than
imported, to avoid pulling config_flow into the runtime coordinator's
import graph or vice versa for a two-line check) and treat it the same
as an empty serial: fall back to host/port.

Type detection (bug 1) and the door sensor's field-name gap (bug 3),
also reported in this issue, are already fixed via the
claude/device-support-issue-77-freezer branch, which hit the same
ARTIK051_DONGLE_REF family from a different report -- not duplicated
here.
2026-07-27 01:00:05 +00:00
Marc Billow 5d7789eb4e Add confirmed washer/dryer cycle code labels (issue #80)
Five raw course codes were rendering unlabeled because no translation
entry existed for them, confirmed by the reporter selecting each cycle
on the physical appliance and reading back the raw code from the
entity's state:

- washer_cycle_table_02: '52' Eco Cold, '54' Towels, '60' Self Clean+
  (a WF50A8600AV/US). '54' shares a display name with the existing '24'
  Towels -- a different code on the same table legitimately landing on
  the same label, matching the existing '21'/'65' Colors and
  '27'/'5E' Rinse+Spin pairs, not a duplicate-in-error.
- dryer_cycle_table_03: '01' Normal, '06' Time dry (a DVE50A8600V/A3,
  the same model added in the previous commit's detection fix).

No code changes -- select.py already derives which raw values it
normalizes from the shipped catalog, so labelling a code is purely a
translations/en.json (mirrored to nl.json) addition.
2026-07-27 00:47:16 +00:00
Marc Billow bae1ac4337 Fix dryer detection when description pairs two model numbers (issue #79)
DVE50A8600V/A3 reports description
'DA_WM_TP1_21_COMMON_DVE50A8800_8600/DC92-02835A_0080' -- a paired
listing of two related model numbers (DVE50A8800 and DVE50A8600) joined
by an underscore, rather than the usual single trailing consumer-model
token. for_device_by_model only ever checked the literal last
underscore segment ('8600', which has no recognizable 2-letter prefix
on its own), so the real 'DV' token one segment earlier was never
reached and the device fell back to 'unknown' with only common
capabilities -- no dry level, cycle, or wrinkle-prevent entities.

Replace the single last-segment extraction with _consumer_model_key,
which scans segments from the end and returns the first one that
resolves. Behavior is unchanged for every existing single-token
description (the last segment still matches first); it just keeps
looking when that segment doesn't.
2026-07-27 00:44:23 +00:00
Marc Billow 643aac92f8 Lock in the same ARTIK051_DONGLE_REF fix for the fridge half (issue #78)
RR40M7165WW is the fridge half of the same household dongle setup as
issue #77's freezer -- identical pipe-delimited ARTIK051_DONGLE_REF
modelNum, so the previous commit's detection and door-sensor fixes
already cover it with no further code changes. Add its fixture as a
second, independent regression case: it exercises the 'cooler' instance
segment instead of 'freezer' for both the temperature pattern caps and
DOOR_GENERIC, and notably reports /door/onedoorfreezer/vs/0 despite
being a single-door fridge (shared firmware naming across the product
line, not an actual second compartment) -- worth having its own golden
so that stays working too.
2026-07-27 00:41:25 +00:00
Marc Billow 8194ea9e87 Fix ARTIK051_DONGLE_REF freezer type detection and door sensor (issue #77)
RZ32M713EWW/EE (an ARTIK051-dongle standalone freezer) reports no
oneUiVersion and a pipe-delimited modelNum
('ARTIK051_DONGLE_REF|<rest>') -- REF is the last underscore segment
before the pipe, not wrapped in underscores on both sides like the
'..._REF_...' shape for_device_by_model's substring check expected, so
the device fell through to 'unknown' with only common capabilities:
no door sensor, no temperature sensors, nothing fridge-specific.

Replace the substring check with a segment-based one
(_model_num_segments splits the pipe-delimited prefix on '_') that
catches both shapes. Same root cause, same fix, and same device family
independently reported and root-caused in issue #83 (which also covers
two further bugs -- config-flow/coordinator serial collisions on a
second symptom of this firmware, 'Nothing(SVC)' as a literal serial --
not needed here since this reporter has a single unit; left for #83).

Once routed to the refrigerator registry, fridge.py's existing pattern
capabilities pick up /temperature/current/freezer/0 and
/temperature/desired/freezer/0 for free -- they were never the actual
problem, just unreachable under the 'unknown' fallback (which never
tries pattern capabilities at all). The door sensor needed one more
fix: /door/onedoorfreezer/vs/0 reports the vendor-prefixed
x.com.samsung.da.openState, not the bare openState DOOR_GENERIC read,
so the entity existed but stayed permanently unavailable. Check both
field names via rep_fn.
2026-07-27 00:39:33 +00:00
Marc Billow 3afbe6c6c1 Add humidity/temperature sensors and horizontal swing for AC (issue #75)
Three gaps reported against an ARTIK051_PRAC_20K WindFree unit vs. the
SmartThings integration:

1. Missing WindFree/motion convenient-mode presets -- left alone here.
   PR #91 replaces climate.py's static _DEVICE_TO_PRESET table with a
   generic resolver that reads any preset code straight off the unit's
   own supportedModes, which already covers this (and more generically
   than a per-model dict would) -- adding one here would just conflict.

2. No horizontal oscillation: /wind/direction/vs/0's supportedModes
   includes Left_And_Right, which _DEVICE_TO_SWING had no mapping for.
   Add it to HA's standard 'horizontal' swing constant.

3. No standalone humidity/current-temperature sensors: the climate card
   already reads both internally, but nothing exposed them as entities
   for history/automations. Add CURRENT_TEMPERATURE (OCF
   /temperature/current/0) with a CURRENT_TEMPERATURE_VS vendor fallback
   (same match_fn-gated pair shape as common.py's POWER_GENERIC/
   POWER_VS_FALLBACK), and a HUMIDITY sensor reading /humidity/vs/0's
   fivepercentHumidity field -- the only one of the three
   humidity-shaped fields across /humidity/0 and /humidity/vs/0 that
   isn't permanently stuck at 0 on every dump seen.

Regenerates the five existing AC goldens (all pick up
current_temperature_c; most pick up humidity) and adds a dedicated
fixture from the issue's WindFree dump, whose /humidity/vs/0 actually
has live fivepercentHumidity data.
2026-07-27 00:33:35 +00:00
Marc Billow c72b5a988e Add range/oven detection for boards missing /information/vs/0 (issue #74)
NE63B8411SS reports no oneUiVersion and no /information/vs/0 resource at
all, so neither for_device nor for_device_by_model's modelNum tokens have
anything to key off -- it fell through to the unknown-device fallback,
which also mis-binds /temperatures/vs/0 against fridge.py's setpoint
capability (a collision the oven family's own capabilities are normally
excluded from the global registry specifically to avoid).

Add a resources-based signature to for_device_by_resources(): 'Bake' in
/mode/vs/0's supportedModes is oven/range-exclusive vocabulary, and paired
with the /oven/vs/0 cavity resource it reliably identifies this family
even with no model info at all. Route to 'range' when a cooktop-status
resource is also present, else plain 'oven'.

This board's cooktop half also doesn't expose the per-burner
/cooktop/status/vs/0 array range.py already models -- only the coarser
/cooktopmonitoring/vs/0 summary resource. Add a read-only
COOKTOP_MONITORING capability for it (cooktop running state, warming
center state) rather than leaving it unbound.
2026-07-27 00:23:04 +00:00
vmvarga 2fd8ff8260 merge temp_setpoint 2026-07-26 11:05:13 +02:00
vmvarga 00cf8d676d feat: laundry firmware-flag gating, fridge vendor temp writes, course names 2026-07-25 10:01:56 +02:00
114 changed files with 13445 additions and 206 deletions
+5 -1
View File
@@ -23,14 +23,18 @@ Your state stays on your LAN: HA talks to the appliance over a direct DTLS sessi
|---|---|
| Air conditioner | `by_type/airconditioner.py` |
| Air purifier | `by_type/air_purifier.py` |
| Dehumidifier | `by_type/dehumidifier.py` |
| Dryer | `by_type/dryer.py` |
| Oven | `by_type/oven.py` |
| Cooktop (read-only burner status) | `by_type/cooktop.py` |
| Microwave | `by_type/microwave.py` |
| Gas cooktop (read-only burner status) | `by_type/cooktop.py` |
| Range hood | `by_type/range_hood.py` |
| Range | `by_type/range.py` |
| Dishwasher | `by_type/dishwasher.py` |
| Refrigerator | `by_type/refrigerator.py` |
| Washer | `by_type/washer.py` |
| Water purifier | `by_type/water_purifier.py` |
| Vacuum clean/auto-empty station | `by_type/vacuum_station.py` |
Each registry composes shared and family-specific `Capability` objects from `registry/capabilities/`; those modules document the individual resources/entities in more depth than a README table can stay current with.
+198 -32
View File
@@ -20,10 +20,13 @@ back for, power, mode, temperature and wind resources alike.
"""
from __future__ import annotations
import logging
from homeassistant.components.climate import (
ClimateEntity,
ClimateEntityFeature,
HVACMode,
PRESET_NONE,
)
from homeassistant.config_entries import ConfigEntry
from homeassistant.const import UnitOfTemperature
@@ -45,6 +48,7 @@ from .registry.capabilities.airconditioner import (
HREF_TEMPS_VS as TEMPS_VS_HREF,
HREF_WIND_STRENGTH as WIND_STRENGTH_HREF,
HREF_WIND_DIRECTION as WIND_DIRECTION_HREF,
HREF_WIND_OSCILLATION as WIND_OSCILLATION_HREF,
HREF_CONVENIENT as CONVENIENT_HREF,
)
from .registry.capabilities.common import normalize_temp_unit
@@ -53,6 +57,8 @@ from .const import DOMAIN
from .coordinator import LocalThingsCoordinator
from .entity import LocalThingsEntity, _is_included
_LOGGER = logging.getLogger(__name__)
_MODES_FIELD = 'x.com.samsung.da.modes'
_SUPPORTED_FIELD = 'x.com.samsung.da.supportedModes'
@@ -62,12 +68,39 @@ _SUPPORTED_FIELD = 'x.com.samsung.da.supportedModes'
_DEVICE_TO_HVAC: dict[str, HVACMode] = {
'Cool': HVACMode.COOL,
'Dry': HVACMode.DRY,
# Fan-only is spelled 'Wind' on some boards (e.g. TP1X_DA-AC-RAC-01001) and
# 'Fan' on others (e.g. TP1X_DA-AC-RAC-01011); both map to FAN_ONLY. The
# reverse write can't rely on this map alone (two codes, one HA value) --
# _device_code_for_hvac() resolves the code from the unit's own
# supportedModes, so this is only a fallback for a unit reporting no
# supportedModes at all. 'Fan' is listed first so the {v: k} reverse
# comprehension below has 'Wind' win that fallback (last-key-wins),
# preserving the original single-spelling behavior rather than silently
# flipping it when 'Fan' was added.
'Fan': HVACMode.FAN_ONLY,
'Wind': HVACMode.FAN_ONLY,
'Auto': HVACMode.HEAT_COOL,
# The device's 'Auto' is a single-setpoint "device decides" mode -> HA
# HVACMode.AUTO (renders "Auto"). Not HEAT_COOL: that renders "Heat/cool"
# and implies a two-setpoint heat+cool range these single-setpoint units
# (including cool-only models) don't have.
'Auto': HVACMode.AUTO,
'Heat': HVACMode.HEAT,
}
_HVAC_TO_DEVICE = {v: k for k, v in _DEVICE_TO_HVAC.items()}
# AI-driven auto-comfort mode (issue #93, A-CAWW-TP2-20-COMMON). Not a flat
# _DEVICE_TO_HVAC entry: 'AIComfort' isn't a distinct thermodynamic operation
# like Cool/Dry/Heat, it's an AI overlay on top of the device's own 'Auto'
# behavior -- confirmed by this unit reporting both 'Auto' and 'AIComfort' as
# separate, mutually-exclusive entries in /mode/vs/0's supportedModes. Modeled
# the idiomatic HA way instead: hvac_mode reports AUTO (same as the plain
# 'Auto' code maps to) and a dedicated 'ai_comfort' preset carries the
# distinction a bare hvac_mode can't. Not reachable via async_set_hvac_mode --
# entered/left only through the preset, since there's no dedicated HVACMode
# value for it to write back to.
_AI_COMFORT_MODE = 'AIComfort'
PRESET_AI_COMFORT = 'ai_comfort'
# Fan (wind strength): device codes "0".."4" -> HA standard fan constants where
# a clean match exists so they auto-localize; "turbo" is custom (translated).
_DEVICE_TO_FAN: dict[str, str] = {
@@ -84,19 +117,42 @@ _DEVICE_TO_SWING: dict[str, str] = {
'Fix': 'off',
'All': 'both',
'Up_And_Low': 'vertical',
'Left_And_Right': 'horizontal', # issue #75
}
_SWING_TO_DEVICE = {v: k for k, v in _DEVICE_TO_SWING.items()}
# Preset (convenient mode): Off/Sleep map onto HA standard presets; Quiet/Smart/
# Speed are custom (translated).
_DEVICE_TO_PRESET: dict[str, str] = {
'Off': 'none',
'Sleep': 'sleep',
'Quiet': 'quiet',
'Smart': 'smart',
'Speed': 'speed',
}
_PRESET_TO_DEVICE = {v: k for k, v in _DEVICE_TO_PRESET.items()}
# Swing fallback via /wind/oscillation/vs/0 (issue #126) -- boards without
# WIND_DIRECTION_HREF at all report two independent Swing|Fix toggles
# instead of one combined code. Same HA vocabulary as _DEVICE_TO_SWING
# above (off/vertical/horizontal/both), just read from/written to a pair
# of fields rather than a single one.
def _oscillation_swing(rep: dict) -> str | None:
vertical = rep.get('vertical')
horizontal = rep.get('horizontal')
if vertical is None and horizontal is None:
return None
v = vertical == 'Swing'
h = horizontal == 'Swing'
if v and h:
return 'both'
if v:
return 'vertical'
if h:
return 'horizontal'
return 'off'
# Preset (convenient mode): resolved dynamically from the device's own
# /mode/convenient/vs/0 supportedModes -- no per-model table. The device 'Off'
# code maps to HA's PRESET_NONE ("no preset active"); every other code is
# exposed as its lowercased self and labelled in translations
# (entity.climate.airconditioner.state_attributes.preset_mode.state.<code>),
# so any board's convenient modes surface without code changes, and an
# unlabelled code just renders as its raw value until a label is added.
# (Samsung's WindFree still-air cooling shows up here as the 'Nano'/
# 'NanoSleep' codes on cool-only global RAC boards -- that's just a
# translation label, not a hard-coded mode.)
def _preset_to_ha(code) -> str:
return PRESET_NONE if code == 'Off' else str(code).lower()
async def async_setup_entry(
@@ -164,6 +220,11 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
| ClimateEntityFeature.TURN_ON
| ClimateEntityFeature.TURN_OFF
)
# (href, raw device code) pairs already logged by _warn_unmapped --
# these properties are read on every coordinator refresh, so an
# un-deduped warning would spam the log for any device with a
# genuinely unrecognized code.
self._warned_unmapped: set[tuple[str, str]] = set()
# -- resource helpers ---------------------------------------------------
@@ -171,25 +232,59 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
return self.coordinator.resource(href) or {}
def _is_on(self) -> bool:
rep = self._rep(POWER_HREF)
if 'value' in rep:
return bool(rep.get('value'))
vs = self._rep(POWER_VS_HREF)
return str(vs.get('x.com.samsung.da.power', '')).lower() == 'on'
# Prefer the vendor /power/vs/0 (present on every observed board and
# the resource writes target -- see airconditioner._climate_write).
# The OCF /power/0 is absent on many boards and a stale mirror on
# some, so reading it first showed pre-write state after a power
# toggle (issue #53: "can turn on but not off").
power = self._rep(POWER_VS_HREF).get('x.com.samsung.da.power')
if power is not None:
return str(power).lower() == 'on'
return bool(self._rep(POWER_HREF).get('value'))
def _supported(self, href: str) -> list[str]:
return list(self._rep(href).get(_SUPPORTED_FIELD) or [])
def _warn_unmapped(self, href: str, code: str) -> None:
"""Log once per (href, code) when a device-reported mode has no
entry in the relevant device<->HA map, so a real device gap surfaces
in the log instead of silently vanishing (issue #93)."""
key = (href, code)
if key in self._warned_unmapped:
return
self._warned_unmapped.add(key)
_LOGGER.warning(
"%s: device mode %r on %s has no HA mapping and was dropped; "
"please file an issue with your diagnostics dump",
self.entity_id, code, href,
)
def _read_mode(self, href: str, mapping: dict):
"""Current mode of a wind/convenient resource, mapped to its HA value."""
return mapping.get(_first(self._rep(href).get(_MODES_FIELD)))
raw = _first(self._rep(href).get(_MODES_FIELD))
if raw is not None and raw not in mapping:
self._warn_unmapped(href, raw)
return mapping.get(raw)
def _read_modes(self, href: str, mapping: dict) -> list[str]:
"""Supported modes of a resource, mapped to HA values (unknowns dropped)."""
return [mapping[c] for c in self._supported(href) if c in mapping]
supported = self._supported(href)
for c in supported:
if c not in mapping:
self._warn_unmapped(href, c)
return [mapping[c] for c in supported if c in mapping]
# -- temperature --------------------------------------------------------
def _ocf_temp_authoritative(self) -> bool:
"""True when the OCF /temperature/{current,desired}/0 pair is the
authoritative temperature channel -- signalled by
/temperature/current/0 being present. Those boards honour reads/
writes on /temperature/desired/0 and ignore the vendor
/temperatures/vs/0; boards without the pair (only a desired stub, or
nothing) are the reverse. Confirmed on live units of both kinds."""
return bool(self._rep(TEMP_CURRENT_HREF))
def _temps_vs(self) -> dict:
"""Vendor `/temperatures/vs/0` items[0] (empty {} when absent)."""
return _temps_vs_item(self._rep(TEMPS_VS_HREF))
@@ -212,10 +307,14 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
@property
def target_temperature(self):
v = _num(self._rep(TEMP_DESIRED_HREF).get('temperature'))
if v is None:
v = _num(self._temps_vs().get('x.com.samsung.da.desired'))
return v
# Read from the same channel writes go to (see async_set_temperature):
# OCF /temperature/desired/0 on boards with the full OCF pair, vendor
# /temperatures/vs/0 otherwise -- with the other as fallback.
ocf = _num(self._rep(TEMP_DESIRED_HREF).get('temperature'))
vs = _num(self._temps_vs().get('x.com.samsung.da.desired'))
if self._ocf_temp_authoritative():
return ocf if ocf is not None else vs
return vs if vs is not None else ocf
def _range(self) -> list | None:
r = self._rep(TEMP_DESIRED_HREF).get('range')
@@ -250,14 +349,23 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
if not self._is_on():
return HVACMode.OFF
device = _first(self._rep(MODE_HREF).get(_MODES_FIELD))
if device == _AI_COMFORT_MODE:
return HVACMode.AUTO
if device is not None and device not in _DEVICE_TO_HVAC:
self._warn_unmapped(MODE_HREF, device)
return _DEVICE_TO_HVAC.get(device, HVACMode.AUTO)
@property
def hvac_modes(self) -> list[HVACMode]:
modes = [HVACMode.OFF]
for m in self._supported(MODE_HREF):
if m == _AI_COMFORT_MODE:
continue
mapped = _DEVICE_TO_HVAC.get(m)
if mapped is not None and mapped not in modes:
if mapped is None:
self._warn_unmapped(MODE_HREF, m)
continue
if mapped not in modes:
modes.append(mapped)
return modes
@@ -271,34 +379,76 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
def fan_modes(self) -> list[str]:
return self._read_modes(WIND_STRENGTH_HREF, _DEVICE_TO_FAN)
def _swing_via_direction(self) -> bool:
"""True when WIND_DIRECTION_HREF is the swing channel to use --
signalled by its presence. Boards without it (issue #126) report
the 2-axis oscillation resource instead; see _oscillation_swing."""
return bool(self._rep(WIND_DIRECTION_HREF))
@property
def swing_mode(self):
return self._read_mode(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
if self._swing_via_direction():
return self._read_mode(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
return _oscillation_swing(self._rep(WIND_OSCILLATION_HREF))
@property
def swing_modes(self) -> list[str]:
return self._read_modes(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
if self._swing_via_direction():
return self._read_modes(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
if self._rep(WIND_OSCILLATION_HREF):
return list(_SWING_TO_DEVICE.keys())
return []
@property
def preset_mode(self):
return self._read_mode(CONVENIENT_HREF, _DEVICE_TO_PRESET)
if _first(self._rep(MODE_HREF).get(_MODES_FIELD)) == _AI_COMFORT_MODE:
return PRESET_AI_COMFORT
code = _first(self._rep(CONVENIENT_HREF).get(_MODES_FIELD))
return _preset_to_ha(code) if code is not None else None
@property
def preset_modes(self) -> list[str]:
return self._read_modes(CONVENIENT_HREF, _DEVICE_TO_PRESET)
modes = [_preset_to_ha(c) for c in self._supported(CONVENIENT_HREF)]
if _AI_COMFORT_MODE in self._supported(MODE_HREF):
modes.append(PRESET_AI_COMFORT)
return modes
# -- writes -------------------------------------------------------------
def _device_code_for_hvac(self, hvac_mode: HVACMode):
"""Device mode code for an HA hvac_mode, chosen from this unit's own
supportedModes -- fan-only is 'Wind' on some boards and 'Fan' on
others, so the reverse map alone can't pick the code this unit
accepts."""
for code in self._supported(MODE_HREF):
if _DEVICE_TO_HVAC.get(code) == hvac_mode:
return code
return _HVAC_TO_DEVICE.get(hvac_mode)
async def async_set_temperature(self, **kwargs) -> None:
# HA's set_temperature service forwards an optional hvac_mode here; honour
# it (set the mode first -- that also powers the unit on when it was off),
# matching the climate contract other integrations follow. Without this a
# set_temperature call carrying hvac_mode (e.g. a dashboard "turn on to
# Auto 24" button) set the setpoint but never changed mode or powered on.
hvac_mode = kwargs.get('hvac_mode')
if hvac_mode is not None:
await self.async_set_hvac_mode(hvac_mode)
if hvac_mode == HVACMode.OFF:
return
temp = kwargs.get('temperature')
if temp is not None:
await self.coordinator.async_send_command(self._bound, ('temperature', temp))
if temp is None:
return
# OCF-pair boards write /temperature/desired/0; vendor boards write
# /temperatures/vs/0 (see airconditioner._climate_write).
kind = 'temperature_ocf' if self._ocf_temp_authoritative() else 'temperature'
await self.coordinator.async_send_command(self._bound, (kind, temp))
async def async_set_hvac_mode(self, hvac_mode: HVACMode) -> None:
if hvac_mode == HVACMode.OFF:
await self.coordinator.async_send_command(self._bound, ('power', False))
return
device = _HVAC_TO_DEVICE.get(hvac_mode)
device = self._device_code_for_hvac(hvac_mode)
if device is None:
return
if not self._is_on():
@@ -321,7 +471,23 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
await self._set_mapped('fan', _FAN_TO_DEVICE, fan_mode)
async def async_set_swing_mode(self, swing_mode: str) -> None:
await self._set_mapped('swing', _SWING_TO_DEVICE, swing_mode)
if self._swing_via_direction():
await self._set_mapped('swing', _SWING_TO_DEVICE, swing_mode)
return
if self._rep(WIND_OSCILLATION_HREF):
await self.coordinator.async_send_command(
self._bound, ('oscillation', swing_mode))
async def async_set_preset_mode(self, preset_mode: str) -> None:
await self._set_mapped('preset', _PRESET_TO_DEVICE, preset_mode)
if preset_mode == PRESET_AI_COMFORT:
# Writes the primary mode resource, not the convenient one --
# 'AIComfort' lives in /mode/vs/0 alongside Cool/Dry/Auto, not in
# /mode/convenient/vs/0 with Quiet/Smart/Speed/Sleep.
await self.coordinator.async_send_command(self._bound, ('mode', _AI_COMFORT_MODE))
return
# Reverse-resolve against the unit's own supportedModes (codes aren't
# a fixed transform of the HA value -- e.g. 'NanoSleep' -> 'nanosleep').
for code in self._supported(CONVENIENT_HREF):
if _preset_to_ha(code) == preset_mode:
await self.coordinator.async_send_command(self._bound, ('preset', code))
return
+13 -1
View File
@@ -197,6 +197,18 @@ def _find_live_ports(host: str, ports: list[int], timeout: float) -> list[int]:
return _order_candidates(live)
def _is_placeholder_serial(serial: str) -> bool:
"""True for a non-empty serialNum that isn't actually a real identity.
The ARTIK051_DONGLE_REF firmware family reports the literal string
'Nothing(SVC)' for every unit -- non-empty, so the plain `if not
serial` check here (and the equivalent one in coordinator.py's
`_run_discovery`) doesn't catch it, and two such units get the same
config-entry unique_id / entity unique_ids and collide (issue #83).
"""
return serial.strip().lower().startswith('nothing')
def _probe_and_validate(host: str, ca_cert_pem: str, ca_key_pem: str) -> dict:
"""Fetch UUID, mint leaf cert, probe each port. Returns config entry data dict."""
import cbor2
@@ -261,7 +273,7 @@ def _probe_and_validate(host: str, ca_cert_pem: str, ca_key_pem: str) -> dict:
.get('/information/vs/0', {})
.get('x.com.samsung.da.serialNum', '')
)
if not serial:
if not serial or _is_placeholder_serial(serial):
serial = f"{host}:{port}"
one_ui_version = (
resources
+7
View File
@@ -42,6 +42,13 @@ LIVENESS_PROBE_TIMEOUT_S = 1.5
# without stalling setup; it matches the per-resource read timeout elsewhere.
PROBE_GET_TIMEOUT_S = 10.0
# Base for the local (client-side) DTLS source port, distinct from the
# destination probe ports above. See coordinator._local_source_port for why a
# fixed per-device source port matters and how the per-device offset is
# derived. Base mirrors the upstream smartthings-local reference bridge.
# Requires smartthings-local >= 0.1.1.
DTLS_LOCAL_PORT_BASE = 49700
SUMMARY_INTERVAL_S = 30.0
DEVICE_SUPPORT_ISSUE_URL = (
+123 -17
View File
@@ -2,9 +2,11 @@
from __future__ import annotations
import asyncio
import ipaddress
import logging
import threading
import time
import zlib
from datetime import timedelta
from typing import Any
@@ -22,7 +24,12 @@ from smartthings_local.ocf.state_cache import StateCache
from .registry.batch import parse_device0_batch
from .registry.by_type import for_device, for_device_by_model, for_device_by_resources
from .registry.capabilities.common import merge_options_field, remote_control_enabled
from .registry.capabilities.common import (
merge_items_field,
merge_options_field,
remote_control_enabled,
remote_control_required_for_write,
)
from .registry.discovery import discover, BoundEntity
from .registry import CAPABILITIES
from .registry.adapter import flatten
@@ -32,6 +39,7 @@ from .observe import ObserveManager, MODE_OBSERVE, MODE_POLL, GRACE_PERIOD_S
from .const import (
DOMAIN, CONF_HOST, CONF_PORT, CONF_LEAF_CERT_PEM, CONF_LEAF_KEY_PEM,
CONF_BYPASS_REMOTE_CONTROL, DEVICE_SUPPORT_ISSUE_URL, SUMMARY_INTERVAL_S,
DTLS_LOCAL_PORT_BASE,
)
_LOGGER = logging.getLogger(__name__)
@@ -49,6 +57,45 @@ class _NoOpDescriptor:
_RECOVERY_RETRY_S = 600.0 # re-attempt observe mode this often while polling
def _local_source_port(host: str) -> int:
"""Deterministic UDP source port for this device's DTLS socket.
Binding the same source port on every (re)connect keeps the client on one
5-tuple, so the appliance evicts an orphaned session left by a previous run
(unclean shutdown -> no DTLS close_notify) at handshake time per RFC 6347
§4.2.8, instead of holding it for 5-15 min while the new session's reads
hang. See DTLS_LOCAL_PORT_BASE in const.py. Requires smartthings-local
>= 0.1.1 (the version that added DtlsCoapSession(local_port=...)).
The port must be stable across restarts and unique per device on this HA
host: the library's socket is unconnected (recvfrom), so two devices
sharing a source port would mis-demux each other's datagrams. For the usual
dotted-IPv4 host we use the last octet as the offset (unique on a /24);
anything else folds a stable CRC32 into the same 256-wide window.
"""
try:
offset = int(ipaddress.IPv4Address(host)) & 0xFF
except (ipaddress.AddressValueError, ValueError):
offset = zlib.crc32(host.encode()) & 0xFF
return DTLS_LOCAL_PORT_BASE + offset
def _is_placeholder_serial(serial: str) -> bool:
"""True for a non-empty serialNum that isn't actually a real identity.
The ARTIK051_DONGLE_REF firmware family reports the literal string
'Nothing(SVC)' for every unit -- non-empty, so the plain `if not
serial` check below doesn't catch it, and `device_serial` feeds both
the HA device-registry identifier and every entity's unique_id
(entity.py), so two such units on the same install silently collide
and the second one's entities get dropped (issue #83). Mirrors the
identical helper in config_flow.py's `_probe_and_validate` -- kept
separate rather than imported to avoid pulling the config-flow module
into the runtime coordinator's import graph for a two-line check.
"""
return serial.strip().lower().startswith('nothing')
class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
"""Manages one Samsung appliance: session, discovery, polling."""
@@ -64,6 +111,24 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
_OBSERVE_GRACE_PERIOD_S: float = GRACE_PERIOD_S
_RECONNECT_PAUSE_S: float = 5.0
# A single reconnect is normal appliance-side behavior (see the
# README's "Known device behavior" section) -- Samsung's firmware
# drops the DTLS session briefly every now and then, and the
# coordinator recovering from that on its own isn't something a user
# needs to see at WARNING. Only escalate once reconnects pile up
# within a trailing window (issue #119).
#
# The window can't be a literal 60s: consecutive reconnect attempts are
# never closer together than one summary poll interval (SUMMARY_INTERVAL_S,
# 30s) plus _RECONNECT_PAUSE_S, so at most ~2 can ever land inside a 60s
# window regardless of how unhealthy the connection is -- a threshold of
# 5 there could never fire, silently downgrading every reconnect
# (including a persistently broken one) to INFO forever. 300s/3 instead:
# reachable under normal polling, and 3 reconnects inside 5 minutes is
# still a reasonable proxy for the README's "actually broken" case.
_RECONNECT_WARN_WINDOW_S: float = 300.0
_RECONNECT_WARN_THRESHOLD: int = 3
# A block-level ACK timeout on the summary GET doesn't prove the
# session is dead (see _poll_once) — require this many in a row
# before treating it as one. A single slow transfer on an otherwise
@@ -115,6 +180,7 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
self.one_ui_version: str = ''
self._consecutive_poll_timeouts = 0
self._unbound_hrefs: list[str] = []
self._reconnect_times: list[float] = []
# ------------------------------------------------------------------
# Session management (all blocking — must run in executor)
@@ -142,7 +208,8 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
key_pem = self._entry.data[CONF_LEAF_KEY_PEM]
sess = DtlsCoapSession(host, port, cert_pem=cert_pem, key_pem=key_pem,
on_notification=self._observe.on_notification)
on_notification=self._observe.on_notification,
local_port=_local_source_port(host))
sess.connect()
sess.start_reader()
self._session = sess
@@ -312,7 +379,7 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
self._unbound_hrefs = unbound
serial = info.get('x.com.samsung.da.serialNum', '')
if not serial:
if not serial or _is_placeholder_serial(serial):
serial = self._entry.data[CONF_HOST]
self.device_serial = serial
@@ -423,6 +490,17 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
self._consecutive_poll_timeouts += 1
return self._consecutive_poll_timeouts < self._POLL_TIMEOUT_LIMIT
def _reconnect_is_frequent(self) -> bool:
"""True once this cycle's reconnect is the Nth within the trailing
warn window -- see _RECONNECT_WARN_WINDOW_S/_RECONNECT_WARN_THRESHOLD."""
now = time.monotonic()
self._reconnect_times = [
t for t in self._reconnect_times
if now - t < self._RECONNECT_WARN_WINDOW_S
]
self._reconnect_times.append(now)
return len(self._reconnect_times) >= self._RECONNECT_WARN_THRESHOLD
# ------------------------------------------------------------------
# DataUpdateCoordinator hook
# ------------------------------------------------------------------
@@ -449,7 +527,13 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
self._consecutive_poll_timeouts = 0
# One reconnect attempt — pause briefly so the device can
# clean up its DTLS session state before we knock again.
self._log.warning("poll failed, reconnecting: %s", e)
# A lone reconnect is routine (see the README's "Known
# device behavior" section); only warn once they're piling
# up within the trailing window.
if self._reconnect_is_frequent():
self._log.warning("poll failed, reconnecting: %s", e)
else:
self._log.info("poll failed, reconnecting: %s", e)
await self.hass.async_add_executor_job(self._close_session)
await asyncio.sleep(self._RECONNECT_PAUSE_S)
try:
@@ -531,7 +615,10 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
opted this device out of it via CONF_BYPASS_REMOTE_CONTROL (issue
#54: some devices accept certain writes, e.g. a washer's default
dosing levels, even while reporting remote control off, so the
block's assumption doesn't hold for every model)."""
block's assumption doesn't hold for every model), or the laundry
firmware flag isModelSettingWithoutSC declares settings writable
without Smart Control (cycle start/pause/stop on /operational/state
still require it)."""
desc = bound_entity.desc
write_fn = getattr(desc, 'write_fn', None)
if write_fn is None:
@@ -540,7 +627,11 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
rep = self._cache.get(href or '') or {}
resources = self._cache.snapshot()
bypass_remote_control = self._entry.options.get(CONF_BYPASS_REMOTE_CONTROL, False)
if not bypass_remote_control and not remote_control_enabled(resources):
if (
not bypass_remote_control
and remote_control_required_for_write(resources, href or '')
and not remote_control_enabled(resources)
):
raise ServiceValidationError(
translation_domain=DOMAIN,
translation_key="remote_control_disabled",
@@ -553,7 +644,10 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
translation_domain=DOMAIN,
translation_key=error,
)
result = write_fn(payload, rep, href)
try:
result = write_fn(payload, rep, href, resources)
except TypeError:
result = write_fn(payload, rep, href)
if result is None:
self._log.warning("write_fn rejected payload %r for %s", payload, href)
return
@@ -611,23 +705,35 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
# introduced its own races around overlapping writes to the same
# href. Simpler and safer to just hold the guard for the full,
# generously-sized window and let it expire on its own.
# write_fn bodies that touch x.com.samsung.da.options carry only the
# changed token(s) now (issue #54: confirmed sufficient on the wire --
# the device merges by prefix itself), not the whole packed array.
# observe.apply()'s field-level {**cached, **rep} merge doesn't know
# that -- handed the bare token list, it would replace the cached
# field outright and wipe every sibling option for the rest of the
# settle window. Pre-merge it here the same way the device does, so
# the optimistic cache entry stays complete; the minimal `body` below
# is still exactly what goes out over the wire.
# write_fn bodies that touch x.com.samsung.da.options or
# x.com.samsung.da.items carry only the changed token(s)/item now
# (issue #54 for options; the AC vendor temperature write for items --
# confirmed sufficient on the wire, the device merges the rest itself),
# not the whole packed array. observe.apply()'s field-level
# {**cached, **rep} merge doesn't know that -- handed the bare
# partial value, it would replace the cached field outright and wipe
# every sibling option/item for the rest of the settle window.
# Pre-merge it here the same way the device does, so the optimistic
# cache entry stays complete; the minimal `body` below is still
# exactly what goes out over the wire.
optimistic_body = body
new_options = body.get('x.com.samsung.da.options')
if isinstance(new_options, list):
cached_options = (self._cache.get(write_href) or {}).get('x.com.samsung.da.options')
optimistic_body = {
**body,
**optimistic_body,
'x.com.samsung.da.options': merge_options_field(cached_options, new_options),
}
# Same fact, items[] shape (e.g. airconditioner._climate_write's vendor
# temperature write, which now carries only {id, desired} -- see that
# module for the write-side half of this).
new_items = body.get('x.com.samsung.da.items')
if isinstance(new_items, list):
cached_items = (self._cache.get(write_href) or {}).get('x.com.samsung.da.items')
optimistic_body = {
**optimistic_body,
'x.com.samsung.da.items': merge_items_field(cached_items, new_items),
}
self._observe.apply(write_href, optimistic_body, source='optimistic')
self._observe.mark_write_pending(
write_href, settle_s=self._POST_TIMEOUT_S + self._POLL_TIMEOUT_S
+13 -4
View File
@@ -8,6 +8,7 @@ from homeassistant.helpers.device_registry import DeviceInfo
from homeassistant.const import EntityCategory
from .registry.adapter import _key
from .registry.batch import is_stub_rep
from .registry.discovery import BoundEntity, _snake_to_title
from .const import DOMAIN
@@ -21,9 +22,17 @@ def _is_included(bound: BoundEntity, coordinator: 'LocalThingsCoordinator') -> b
require that field to be present in the resource rep so that optional
fields on shared resources don't create phantom entities.
An empty rep ({}) means /device/0 returned a stub for this resource —
the resource exists on the device but data hasn't been fetched yet.
In that case we include the entity so it can be populated by sub-polls.
A stub rep (is_stub_rep — /device/0's "resource exists, no data fetched
yet" marker) is included anyway so it can be populated by sub-polls. A
genuinely empty {} rep is included too by this default gate -- whether
empty means "not populated yet" or "permanently unsupported" needs
per-field domain knowledge this generic gate doesn't have: /alarms/vs/0's
{} is fridge.py's documented *normal* no-alarm state (see
_active_alarm_codes), not an absence signal, and it's far from the only
resource like that. Only a capability whose author has actually verified
a field is genuinely never populated on unsupported hardware opts into
stricter gating with its own is_stub_rep-based exists_fn (see
common.ENERGY_METER, issue #127) -- this default stays permissive.
"""
rep = coordinator.last_resources.get(bound.href)
if rep is None:
@@ -31,7 +40,7 @@ def _is_included(bound: BoundEntity, coordinator: 'LocalThingsCoordinator') -> b
if bound.desc.exists_fn is not None:
return bound.desc.exists_fn(rep, coordinator.last_resources)
if bound.desc.field:
if not rep: # stub — resource known to exist, data not yet fetched
if not rep or is_stub_rep(rep):
return True
return bound.desc.field in rep
return True # rep_fn or no-field entities (ButtonDesc) are always included
+255 -12
View File
@@ -1,7 +1,20 @@
"""Fan platform for Samsung range hoods."""
"""Fan platform for Samsung range hoods and air purifiers.
Three FanDesc-bound hrefs exist, dispatched by href in async_setup_entry
below since each needs different HA fan semantics: the range hood's fan
speed and the older ARTIK051_TVTL air-purifier family's Auto/Sleep/Low/
Medium/High (issue #56) are both an ordered set of numeric levels
(SET_SPEED) -- the latter confirmed monotonic in capabilities/
air_purifier.py's module docstring, with no named-mode list to preserve
since this board never self-reports one. The newer TP1X air-purifier
family's modes (Smart/Max/Mid/WindFree/Sleep, issue #130) are named
behaviors with no linear order (PRESET_MODE), reported directly by that
board's own supportedModes."""
from __future__ import annotations
import logging
from homeassistant.components.fan import FanEntity, FanEntityFeature
from homeassistant.config_entries import ConfigEntry
from homeassistant.core import HomeAssistant
@@ -14,13 +27,21 @@ from homeassistant.util.percentage import (
from .const import DOMAIN
from .coordinator import LocalThingsCoordinator
from .entity import LocalThingsEntity, _is_included
from .registry.capabilities.air_purifier import HREF_AIRFLOW
from .registry.capabilities.air_purifier import HREF_MODE as AIR_PURIFIER_FAN_HREF
from .registry.entities import FanDesc
_LOGGER = logging.getLogger(__name__)
POWER_HREF = '/power/0'
POWER_VS_HREF = '/power/vs/0'
_FAN_SPEED_FIELD = 'x.com.samsung.da.hood.fanSpeed'
_SUPPORTED_FAN_SPEED_FIELD = 'x.com.samsung.da.hood.supportedFanSpeed'
_MIN_FAN_SPEED_FIELD = 'x.com.samsung.da.hood.settableMinFanSpeed'
_OFF_SPEED_CODE = '0'
_MODES_FIELD = 'x.com.samsung.da.modes'
_SUPPORTED_MODES_FIELD = 'x.com.samsung.da.supportedModes'
async def async_setup_entry(
@@ -29,15 +50,38 @@ async def async_setup_entry(
async_add_entities: AddEntitiesCallback,
) -> None:
coordinator: LocalThingsCoordinator = hass.data[DOMAIN][entry.entry_id]
async_add_entities(
LocalThingsRangeHoodFan(coordinator, bound)
for bound in coordinator.bound
if isinstance(bound.desc, FanDesc) and _is_included(bound, coordinator)
)
entities = []
for bound in coordinator.bound:
if not (isinstance(bound.desc, FanDesc) and _is_included(bound, coordinator)):
continue
if bound.href == AIR_PURIFIER_FAN_HREF:
entities.append(LocalThingsAirPurifierFan(coordinator, bound))
elif bound.href == HREF_AIRFLOW:
entities.append(LocalThingsAirflowFan(coordinator, bound))
else:
entities.append(LocalThingsRangeHoodFan(coordinator, bound))
async_add_entities(entities)
class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
"""A hood fan combining sibling power and fan-speed resources."""
"""A hood fan combining sibling power and fan-speed resources.
Some boards that reuse this capability (built-in microwave vent fans,
issues #137/#142) report no sibling `/power/0` or `/power/vs/0`
resource at all -- fan speed 0 is itself the off state there, with no
separate power toggle to write. `_speed_zero_is_off` detects that
shape from the hood resource's own settableMinFanSpeed/
supportedFanSpeed fields and switches every method below to drive
off/on purely through the fanSpeed field, including '0' in the
ordered speed codes as the off step instead of assuming every
advertised code is an active speed.
This is deliberately not the same question as `_has_separate_power`,
which only proves *some* power resource exists on the device -- on a
combi appliance (e.g. an over-the-range microwave) that resource can
belong to the cavity, not the vent fan, and toggling it from here
would turn off the whole appliance instead of just the fan.
"""
_enable_turn_on_off_backwards_compatibility = False
_attr_supported_features = (
@@ -53,15 +97,35 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
def _rep(self, href: str) -> dict:
return self.coordinator.resource(href) or {}
def _has_separate_power(self) -> bool:
return bool(self._rep(POWER_HREF)) or bool(self._rep(POWER_VS_HREF))
def _speed_zero_is_off(self) -> bool:
"""Whether fan speed '0' is itself this hood's off step, with no
separate power resource to toggle. The board says so directly:
settableMinFanSpeed '0', or '0' inside supportedFanSpeed. The
standalone hood's codes start at 14 and it carries a real /power
resource instead, so this is False there."""
rep = self._rep(self._bound.href)
return (
str(rep.get(_MIN_FAN_SPEED_FIELD, '')) == _OFF_SPEED_CODE
or _OFF_SPEED_CODE in self._all_speed_codes()
)
def _all_speed_codes(self) -> list[str]:
rep = self._rep(self._bound.href)
return [str(value) for value in rep.get(_SUPPORTED_FAN_SPEED_FIELD, ())]
def _active_speed_codes(self) -> list[str]:
# Power is carried by the separate /power resource. fanSpeed retains
# the selected setting while power is off (as the lamp's `current`
# field does), so every advertised code is an active ordered speed.
return self._all_speed_codes()
codes = self._all_speed_codes()
if self._speed_zero_is_off():
# No separate power resource: '0' is the off step, not a speed.
return [code for code in codes if code != _OFF_SPEED_CODE]
# Power is carried by the separate /power resource. fanSpeed
# retains the selected setting while power is off (as the
# lamp's `current` field does), so every advertised code is an
# active ordered speed.
return codes
def _power_payload(self, enabled: bool) -> tuple[str, bool, str]:
"""Target whichever power resource this hood actually exposes."""
@@ -71,6 +135,9 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
@property
def is_on(self) -> bool:
if self._speed_zero_is_off():
current = str(self._rep(self._bound.href).get(_FAN_SPEED_FIELD, '0'))
return current not in ('', _OFF_SPEED_CODE)
rep = self._rep(POWER_HREF)
if 'value' in rep:
return bool(rep.get('value'))
@@ -96,6 +163,18 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
self, percentage: int | None = None, preset_mode: str | None = None,
**kwargs,
) -> None:
if self._speed_zero_is_off():
if percentage is not None:
await self.async_set_percentage(percentage)
return
if self.is_on:
# Already running: no percentage given means "just turn on",
# not "reset to the lowest speed".
return
codes = self._active_speed_codes()
if codes:
await self.coordinator.async_send_command(self._bound, ('speed', codes[0]))
return
await self.coordinator.async_send_command(
self._bound, self._power_payload(True),
)
@@ -103,6 +182,9 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
await self.async_set_percentage(percentage)
async def async_turn_off(self, **kwargs) -> None:
if self._speed_zero_is_off():
await self.coordinator.async_send_command(self._bound, ('speed', _OFF_SPEED_CODE))
return
await self.coordinator.async_send_command(
self._bound, self._power_payload(False),
)
@@ -114,9 +196,170 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
codes = self._active_speed_codes()
if not codes:
return
if not self.is_on:
if not self._speed_zero_is_off() and not self.is_on:
await self.coordinator.async_send_command(
self._bound, self._power_payload(True),
)
code = percentage_to_ordered_list_item(codes, percentage)
await self.coordinator.async_send_command(self._bound, ('speed', code))
class LocalThingsAirPurifierFan(LocalThingsEntity, FanEntity):
"""Air-purifier fan: named preset modes, not an ordered percentage --
see air_purifier.FAN's comment for why (Smart/WindFree/Sleep aren't
"faster/slower" than Max/Mid)."""
_enable_turn_on_off_backwards_compatibility = False
_attr_supported_features = (
FanEntityFeature.PRESET_MODE
| FanEntityFeature.TURN_ON
| FanEntityFeature.TURN_OFF
)
def __init__(self, coordinator: LocalThingsCoordinator, bound) -> None:
super().__init__(coordinator, bound)
self._attr_name = None
def _rep(self, href: str) -> dict:
return self.coordinator.resource(href) or {}
def _mode_rep(self) -> dict:
return self._rep(self._bound.href)
def _power_payload(self, enabled: bool) -> tuple[str, bool, str]:
"""Target whichever power resource this unit actually exposes --
same pattern as LocalThingsRangeHoodFan._power_payload above.
Writing a hardcoded href here would silently no-op on a board that
only reports the other one, even though is_on already falls back
correctly."""
resources = self.coordinator.last_resources
target = POWER_VS_HREF if POWER_VS_HREF in resources else POWER_HREF
return 'power', enabled, target
@property
def is_on(self) -> bool:
power = self._rep(POWER_VS_HREF).get('x.com.samsung.da.power')
if power is not None:
return str(power).lower() == 'on'
return bool(self._rep(POWER_HREF).get('value'))
@property
def preset_modes(self) -> list[str]:
return [
str(code).lower()
for code in self._mode_rep().get(_SUPPORTED_MODES_FIELD, ())
]
@property
def preset_mode(self) -> str | None:
modes = self._mode_rep().get(_MODES_FIELD)
code = modes[0] if isinstance(modes, (list, tuple)) and modes else modes
return str(code).lower() if code is not None else None
async def async_turn_on(
self, percentage: int | None = None, preset_mode: str | None = None,
**kwargs,
) -> None:
await self.coordinator.async_send_command(self._bound, self._power_payload(True))
if preset_mode is not None:
await self.async_set_preset_mode(preset_mode)
async def async_turn_off(self, **kwargs) -> None:
await self.coordinator.async_send_command(self._bound, self._power_payload(False))
async def async_set_preset_mode(self, preset_mode: str) -> None:
# Reverse-resolve against the unit's own supportedModes -- the
# write needs the raw device code (e.g. 'WindFree'), not the
# lowercased HA value.
for code in self._mode_rep().get(_SUPPORTED_MODES_FIELD, ()):
if str(code).lower() == preset_mode:
await self.coordinator.async_send_command(self._bound, ('mode', code))
return
_LOGGER.warning(
"%s: %r is not a valid preset mode (supported: %s)",
self.entity_id, preset_mode, self.preset_modes,
)
_AIRFLOW_SPEED_FIELD = 'speed'
# Raw `speed` codes, low-to-high -- confirmed monotonic (Auto=0, Sleep=1,
# Low=2, Medium=3, High=4) via air_purifier.py's module docstring. Ordered
# as plain strings, same as _all_speed_codes above, so
# ordered_list_item_to_percentage/percentage_to_ordered_list_item can treat
# it exactly like the range hood's numeric levels -- no named-preset table
# needed since this board never reports mode names to hang one off of.
_AIRFLOW_SPEED_CODES = ('0', '1', '2', '3', '4')
class LocalThingsAirflowFan(LocalThingsEntity, FanEntity):
"""ARTIK051_TVTL-class air purifier fan (issue #56): an ordered numeric
speed range, same SET_SPEED shape as LocalThingsRangeHoodFan above."""
_enable_turn_on_off_backwards_compatibility = False
_attr_supported_features = (
FanEntityFeature.SET_SPEED
| FanEntityFeature.TURN_ON
| FanEntityFeature.TURN_OFF
)
def __init__(self, coordinator: LocalThingsCoordinator, bound) -> None:
super().__init__(coordinator, bound)
self._attr_name = None
def _rep(self, href: str) -> dict:
return self.coordinator.resource(href) or {}
def _power_payload(self, enabled: bool) -> tuple[str, bool, str]:
"""Prefer /power/0 like LocalThingsRangeHoodFan above, NOT
LocalThingsAirPurifierFan's vs/0-first order -- that order is only
harmless for the TP1X board because it never reports /power/0 at
all. This family's dumps carry both hrefs, and common.POWER_GENERIC
(the power_switch entity) is unconditionally bound to /power/0
whenever it's present, so writing here to /power/vs/0 first would
leave power_switch and this fan reading/writing two different
resources -- disagreeing until the next poll refreshes the other
one (the same optimistic-apply lag coordinator.py's own comments
warn about)."""
resources = self.coordinator.last_resources
target = POWER_HREF if POWER_HREF in resources else POWER_VS_HREF
return 'power', enabled, target
@property
def is_on(self) -> bool:
power = self._rep(POWER_HREF)
if 'value' in power:
return bool(power.get('value'))
return str(self._rep(POWER_VS_HREF).get('x.com.samsung.da.power', '')).lower() == 'on'
@property
def speed_count(self) -> int:
return len(_AIRFLOW_SPEED_CODES)
@property
def percentage(self) -> int | None:
if not self.is_on:
return 0
current = str(self._rep(self._bound.href).get(_AIRFLOW_SPEED_FIELD, ''))
if current not in _AIRFLOW_SPEED_CODES:
return None
return ordered_list_item_to_percentage(_AIRFLOW_SPEED_CODES, current)
async def async_turn_on(
self, percentage: int | None = None, preset_mode: str | None = None,
**kwargs,
) -> None:
await self.coordinator.async_send_command(self._bound, self._power_payload(True))
if percentage is not None:
await self.async_set_percentage(percentage)
async def async_turn_off(self, **kwargs) -> None:
await self.coordinator.async_send_command(self._bound, self._power_payload(False))
async def async_set_percentage(self, percentage: int) -> None:
if percentage <= 0:
await self.async_turn_off()
return
if not self.is_on:
await self.coordinator.async_send_command(self._bound, self._power_payload(True))
code = percentage_to_ordered_list_item(_AIRFLOW_SPEED_CODES, percentage)
await self.coordinator.async_send_command(self._bound, ('speed', int(code)))
+2 -2
View File
@@ -10,7 +10,7 @@
"requirements": [
"cbor2>=5.4.6",
"pyOpenSSL>=23.0",
"smartthings-local>=0.1.0"
"smartthings-local>=0.1.1"
],
"version": "0.11.1"
"version": "0.14.0"
}
@@ -2,8 +2,25 @@
from __future__ import annotations
def is_stub_rep(rep: dict) -> bool:
"""True for the device's "resource exists, no data fetched yet" marker --
an echoed {"href": "..."} with no other fields.
Distinct from a genuinely empty {} rep, which is the device's confirmed
(if empty) answer -- e.g. an unsupported resource on this model that will
never populate. Conflating the two used to make every field-gated entity
on a permanently-empty resource look like a not-yet-fetched stub forever,
creating phantom always-"unknown" entities (issue #127)."""
return isinstance(rep, dict) and set(rep.keys()) == {'href'}
def parse_device0_batch(device0: list) -> dict[str, dict]:
"""Extract {href: rep} from a /device/0 CBOR list response."""
"""Extract {href: rep} from a /device/0 CBOR list response.
A stub rep is passed through unchanged rather than collapsed to {} --
downstream code (entity._is_included, capability exists_fns) uses
is_stub_rep to tell "not fetched yet" apart from a confirmed-empty {}.
"""
out = {}
for entry in device0[1:]: # skip [0] (device-level rep)
if not isinstance(entry, dict):
@@ -12,8 +29,6 @@ def parse_device0_batch(device0: list) -> dict[str, dict]:
rep = entry.get('rep')
if not href:
continue
# rep == {"href": "..."} is a stub (resource present, no current data).
# Include it as {} so capabilities still bind and the entity exists.
if isinstance(rep, dict):
out[href] = {} if set(rep.keys()) == {'href'} else rep
out[href] = rep
return out
@@ -3,8 +3,9 @@ from typing import Optional
from ._base import DeviceRegistry
from . import (
air_purifier, airconditioner, cooktop, dishwasher, dryer, oven,
range as _range, range_hood, refrigerator, washer,
air_purifier, airconditioner, cooktop, dehumidifier, dishwasher, dryer,
induction_cooktop, microwave, oven, range as _range, range_hood,
refrigerator, vacuum_station, washer, water_purifier,
)
__all__ = [
@@ -19,14 +20,19 @@ _REGISTRY_BY_KEY: dict[str, DeviceRegistry] = {
'airconditioner': airconditioner.REGISTRY,
'air_conditioner': airconditioner.REGISTRY,
'cooktop': cooktop.REGISTRY,
'dehumidifier': dehumidifier.REGISTRY,
'dishwasher': dishwasher.REGISTRY,
'dryer': dryer.REGISTRY,
'induction_cooktop': induction_cooktop.REGISTRY,
'microwave': microwave.REGISTRY,
'oven': oven.REGISTRY,
'hood': range_hood.REGISTRY,
'range': _range.REGISTRY,
'range_hood': range_hood.REGISTRY,
'refrigerator': refrigerator.REGISTRY,
'vacuum_station': vacuum_station.REGISTRY,
'washer': washer.REGISTRY,
'water_purifier': water_purifier.REGISTRY,
}
@@ -82,11 +88,55 @@ _CONSUMER_PREFIX_TO_KEY: dict[str, str] = {
'WD': 'washer',
'WF': 'washer',
'WV': 'washer', # FlexWash twin units (e.g. WV55M9600AW) -- issue #19
'WA': 'washer', # Top-load washers (e.g. WA8000T) -- issue #106
'DV': 'dryer',
'DW': 'dishwasher',
}
def _model_num_segments(model_num: str) -> list[str]:
"""Underscore-delimited segments of modelNum's pipe-prefix.
Most boards wrap a token in underscores on both sides ('..._REF_...'),
which a plain substring check catches fine. But the ARTIK051_DONGLE_REF
family (issues #77, #83) reports modelNum as
'<board>_DONGLE_REF|<rest...>' -- REF is the *last* segment before the
pipe, with no trailing underscore, so '_REF_' never matches and the
device silently fell back to 'unknown'. Splitting on '_' and checking
segment membership catches both shapes without caring which side (if
either) has a delimiter.
"""
prefix = (model_num or '').split('|', 1)[0]
return prefix.split('_')
def _consumer_model_key(description: str) -> Optional[str]:
"""Registry key from the consumer-model token in `description`, or None.
Usually that token is the last '_'-delimited segment before any
'/board-info' suffix (e.g. '..._WW90DG6U25LEU4' -> 'WW90DG6U25LEU4').
But issue #79's dryer pairs two model numbers in one description --
'..._DVE50A8800_8600/DC92-...' -- so the true consumer token
('DVE50A8800') sits one segment *before* the actual last segment
('8600', a bare second model number with no recognizable prefix). Scan
segments from the end and take the first one that resolves, rather
than assuming the last segment is always it.
Only a 2-letter *prefix* match -- e.g. 'WAC' (the Window Air Conditioner
board-family token, issue #87) also starts with 'WA' (the top-load-washer
prefix, issue #106) at this granularity. for_device_by_model() calls the
board-family modelNum checks first and this function only as a fallback,
so that ambiguity resolves correctly without this function needing to
know about unrelated device families.
"""
segments = (description or '').split('/', 1)[0].split('_')
for segment in reversed(segments):
key = _CONSUMER_PREFIX_TO_KEY.get(segment[:2].upper())
if key is not None:
return key
return None
def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegistry]:
"""Fallback device-type detection for hardware that never reports
oneUiVersion (confirmed for washers -- their /otninformation/vs/0 has
@@ -100,18 +150,30 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
DeviceRegistry if the consumer-model code or modelNum resolves to a
known type, None otherwise.
"""
token = (description or '').split('/', 1)[0].rsplit('_', 1)[-1]
key = _CONSUMER_PREFIX_TO_KEY.get(token[:2].upper())
if key is None and '_REF_' in (model_num or ''):
# Board-family modelNum tokens are checked first, and the fuzzier
# 2-letter consumer-model prefix from `description` only as a fallback
# (see the bottom of this function) -- some board tokens are themselves
# only 2-3 letters long ('WAC', issue #87) and would otherwise collide
# with an unrelated consumer prefix at that granularity ('WA', issue #106).
key = None
if key is None and 'REF' in _model_num_segments(model_num):
key = 'refrigerator'
# Room air conditioners (e.g. ARTIK051_PRAC_20K) report no oneUiVersion and
# a modelNum carrying the '_PRAC_' (Package Room Air Conditioner) token.
if key is None and '_PRAC_' in (model_num or ''):
key = 'airconditioner'
# Older/simpler RAC boards (e.g. TP2X_RAC_20K, issue #37) use the plain
# '_RAC_' token instead -- distinct from '_PRAC_' above (no overlap: the
# 'P' sits between the underscore and 'RAC' in that token).
if key is None and '_RAC_' in (model_num or ''):
# Other RAC boards carry a bare 'RAC' (Room Air Conditioner) token in the
# modelNum, in one of two spellings: the underscore form '_RAC_' (e.g.
# TP2X_RAC_20K, issue #37) or the hyphenated form '-RAC-' (e.g.
# TP1X_DA-AC-RAC-01001, a cool-only global variant, issue #91). Both are
# distinct from '_PRAC_' above ('P' sits before 'RAC' with no delimiter)
# and from range ('-RANGE-') / oven ('-OVEN-') tokens. Most TP1X boards
# self-report oneUiVersion and resolve via for_device() upstream of this
# fallback; the hyphenated match is what rescues variants whose
# /otninformation/vs/0 ships no swVersionInfo block at all, so
# oneUiVersion is empty.
if key is None and ('_RAC_' in (model_num or '')
or '-RAC-' in (model_num or '').upper()):
key = 'airconditioner'
# System air conditioners (multi-indoor-unit commercial installs, e.g.
# A-CAWW-TP2-20-COMMON, issue #52) report no oneUiVersion either and
@@ -122,6 +184,32 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
# resource (see airconditioner.py's _AC_IGNORED).
if key is None and '-CAWW-' in (model_num or '').upper():
key = 'airconditioner'
# Dehumidifiers (e.g. TP1X_DA_AC_DHM_01001_0000, issue #88) share the
# DA_AC_ board family with the room-AC models above but carry the
# '_DHM_' (DeHuMidifier) token instead of '_RAC_'/'_PRAC_'. Distinct
# registry: target humidity, not temperature, is the primary control,
# and there's no climate composite.
if key is None and '_DHM_' in (model_num or ''):
key = 'dehumidifier'
# Window air conditioners (e.g. TP1X_DA_AC_WAC_01001_0000, issue #87)
# report no oneUiVersion and carry the '_WAC_' (Window Air Conditioner)
# token instead of '_RAC_'/'_PRAC_'. Same TP1X-class resource surface
# as the room-AC models above (mode/convenient/wind/temperature/power/
# filter/humidity all confirmed against the issue #87 dump binding
# cleanly against the existing airconditioner registry once routed
# here) -- no WAC-specific resources needed.
if key is None and '_WAC_' in (model_num or ''):
key = 'airconditioner'
# ARA-WW-class wall-mount RACs (e.g. ARA-WW-TP1-22-COMMON, issues #115/
# #116/#117/#120) report no oneUiVersion and no '_RAC_'/'-RAC-' token at
# all -- the board family is spelled 'ARA-WW-' instead. Same resource
# surface as the other TP1X-class room ACs above (mode/convenient/wind/
# temperature/power/filter/humidity all confirmed against these dumps
# binding cleanly against the existing airconditioner registry once
# routed here) -- no ARA-WW-specific resources needed, so this reuses
# the same registry rather than adding a new device type.
if key is None and 'ARA-WW-' in (model_num or '').upper():
key = 'airconditioner'
# Air purifiers (e.g. ARTIK051_TVTL_18K, issue #56) report no
# oneUiVersion either, and carry the '_TVTL_' board-family token.
if key is None and '_TVTL_' in (model_num or ''):
@@ -129,6 +217,10 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
model_identity = f'{model_num} {description}'.upper()
if key is None and ('_COOKTOP' in model_identity or '_GB_CT_' in model_identity):
key = 'cooktop'
# Water purifiers (e.g. TP2X_WATERPURIFIER_20K, issue #90) report no
# oneUiVersion and carry the 'WATERPURIFIER' board-family token.
if key is None and 'WATERPURIFIER' in model_identity:
key = 'water_purifier'
if key is None and model_identity.startswith('AHD-'):
key = 'range_hood'
# Range/cooktop-oven combos (e.g. TP1X_DA-KS-RANGE-0102X, issue #44) --
@@ -141,6 +233,40 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
# oneUiVersion and doesn't match the washer/dryer/dishwasher prefix map.
if key is None and '-OVEN-' in (model_num or '').upper():
key = 'oven'
# Microwaves, both combi (e.g. TP1X_DA-KS-MICROWAVE-01041, issue #121)
# and plain (e.g. TP2X_DA-KS-MICROWAVE-01011, issue #66) -- same board
# family as the wall oven above (an '/oven/vs/0' cavity resource, same
# /operational/state/vs/0 + /doors/vs/0 shape), but a distinct mode
# vocabulary (Convection/AirFryer/Grill/MicroWave*) and setpoint bounds
# from the oven registry, plus a powerLevel field ovens don't report --
# its own device type rather than folded into 'oven' (issue #121 shipped
# it onto the oven registry initially; split out per user feedback).
# Reports no oneUiVersion and doesn't match the washer/dryer/dishwasher
# prefix map either.
if key is None and '-MICROWAVE-' in (model_num or '').upper():
key = 'microwave'
# Standalone induction cooktops (e.g. TP1X_DA-KS-COOKTOP-01011, issue
# #86) -- same board family and '/cooktop/status/vs/0' resource shape
# as the range combo above, but no oven attached at all. Distinct from
# the '_COOKTOP'/'_GB_CT_' underscore-delimited check above: that one
# matches a different, older gas-cooktop family (cooktop.py's NA9300K
# class, burner state embedded in /mode/vs/0's options array) whose
# modelNum token is underscore-delimited, not hyphenated like this
# board family's.
if key is None and '-COOKTOP-' in (model_num or '').upper():
key = 'induction_cooktop'
# Stick-vacuum clean/auto-empty station (e.g. A-VSKR-TP1-22-VS9500AL,
# issue #131) -- reports no oneUiVersion and carries the '-VSKR-'
# board-family token. See capabilities/vacuum_station.py for why this
# is its own device type: the resource set (dustbag/dustbin/UV-sanitize
# station state) shares no hrefs with anything else already modeled.
if key is None and '-VSKR-' in (model_num or '').upper():
key = 'vacuum_station'
# Consumer-model prefix from `description` (washer/dryer/dishwasher) --
# last, since it's the fuzziest match (a bare 2-letter prefix) and would
# otherwise shadow the more specific board-family tokens above.
if key is None:
key = _consumer_model_key(description)
return _REGISTRY_BY_KEY.get(key) if key else None
@@ -170,4 +296,18 @@ def for_device_by_resources(resources: dict[str, dict]) -> Optional[DeviceRegist
and '/hood/lamp/vs/0' in resources
):
return _REGISTRY_BY_KEY['range_hood']
# Oven/range-combo boards that report no /information/vs/0 at all
# (issue #74's NE63B8411SS -- the resource is simply absent from the
# dump, not just empty) can't be matched via for_device_by_model's
# modelNum tokens either. 'Bake' is oven/range cook-mode vocabulary that
# no other family's /mode/vs/0 uses (confirmed against the microwave,
# cooktop, and every laundry fixture), so its presence alongside the
# oven cavity resource is a safe signature. Distinguish range (has a
# cooktop half) from a plain wall oven by which cooktop-status resource,
# if any, is also present.
supported_modes = mode.get('x.com.samsung.da.supportedModes') or ()
if '/oven/vs/0' in resources and 'Bake' in supported_modes:
if '/cooktopmonitoring/vs/0' in resources or '/cooktop/status/vs/0' in resources:
return _REGISTRY_BY_KEY['range']
return _REGISTRY_BY_KEY['oven']
return None
@@ -1,10 +1,22 @@
"""Air-purifier device registry (Samsung ARTIK051_TVTL-class, issue #56).
"""Air-purifier device registry.
Reports no oneUiVersion; resolved via for_device_by_model's '_TVTL_' modelNum
token (see registry.py). Reuses dishwasher.DIAGNOSIS for /diagnosis/vs/0
(identical field/write contract).
Spans two board generations sharing this one registry (see
capabilities/air_purifier.py's module docstring for the per-href
match_fn discriminators that keep them from colliding):
- ARTIK051_TVTL-class (issue #56). Reports no oneUiVersion; resolved via
for_device_by_model's '_TVTL_' modelNum token (see registry.py).
- TP1X_DA-AC-AIR-class (issue #130). Self-reports oneUiVersion "7.0 Air
purifier", resolved via for_device(). Adds real fan-mode control plus
display/HEPA-filter/pet-filter/sound resources the older family never
reported; reuses airconditioner.DISPLAY_LIGHT and airconditioner.MUTE_ONCE
for /light/vs/0 and /option/muteonce/vs/0, which are identical shapes on
the shared DA-AC- board family.
Reuses dishwasher.DIAGNOSIS for /diagnosis/vs/0 (identical field/write
contract).
"""
from ..capabilities import air_purifier, common, dishwasher, ignored
from ..capabilities import air_purifier, airconditioner, common, dishwasher, ignored
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
@@ -20,6 +32,16 @@ REGISTRY = DeviceRegistry(
air_purifier.AIRFLOW_GENERIC,
air_purifier.AIRFLOW_VS_FALLBACK,
air_purifier.MODE,
air_purifier.FAN,
air_purifier.DISPLAY,
air_purifier.HEPA_FILTER,
air_purifier.PANEL_STATUS,
air_purifier.PET_FILTER_ACTIVATION,
air_purifier.SOUND_MODE,
air_purifier.SOUND_OUTPUT,
air_purifier.SOUND_VOLUME,
airconditioner.DISPLAY_LIGHT,
airconditioner.MUTE_ONCE,
*air_purifier.COVERAGE,
]),
)
@@ -25,6 +25,10 @@ REGISTRY = DeviceRegistry(
airconditioner.DISPLAY_LIGHT,
airconditioner.MUTE_ONCE,
airconditioner.CURRENT_LIMIT,
airconditioner.ANOMALY_LOAD,
airconditioner.CURRENT_TEMPERATURE,
airconditioner.CURRENT_TEMPERATURE_VS,
airconditioner.HUMIDITY,
*airconditioner.COVERAGE,
]),
)
@@ -1,11 +1,21 @@
"""Cooktop device registry."""
"""Gas cooktop device registry (NA9300K-class, PR #23).
Named 'gas_cooktop' (not 'cooktop') so its diagnostics/device-info label
doesn't collide with the unrelated induction_cooktop family (issue #86,
by_type/induction_cooktop.py) -- two different OCF surfaces that happen to
share the English word "cooktop". The `_REGISTRY_BY_KEY['cooktop']` lookup
key is unchanged: it's relied on by real devices reporting
oneUiVersion "Cooktop" (for_device), the legacy ARTIK051 modelNum rule
(for_device_by_model), and the resource-signature fallback
(for_device_by_resources) alike.
"""
from ..capabilities import common, cooktop, ignored
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='cooktop',
name='gas_cooktop',
capabilities=_build([
*ignored.IGNORED,
cooktop.COOKTOP_POWER,
@@ -0,0 +1,23 @@
"""Dehumidifier device registry (Samsung TP1X_DA_AC_DHM-class, issue #88).
Shares the DA_AC_ board family with airconditioner.py (power, air filter,
auto-clean, mute-once all use the identical resource shapes), so those three
Capability objects are reused directly rather than duplicated.
"""
from ..capabilities import airconditioner, common, dehumidifier, ignored
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='dehumidifier',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*common.POWER,
dehumidifier.MODE,
dehumidifier.HUMIDITY,
airconditioner.AUTO_CLEAN,
airconditioner.AIR_FILTER,
airconditioner.MUTE_ONCE,
*dehumidifier.COVERAGE,
]),
)
@@ -0,0 +1,30 @@
"""Standalone induction-cooktop device registry (Samsung
TP1X_DA-KS-COOKTOP-class, issue #86) -- the cooktop half of the
range/oven board family (see capabilities/range.py), but with no oven
attached at all.
Reuses range.py's COOKTOP_STATUS/COOKTOP_SPEC/COOKTOP_SAFETY/PROBE_STATUS
wholesale (identical resource shapes to the range combo's cooktop half)
and cooktop.PAIRED_HOOD_STATUS for the Bluetooth-paired range hood some
units pair with. Distinct registry key from cooktop.REGISTRY ('cooktop')
-- that family is the unrelated NA9300K-class gas cooktop (burner state
embedded in /mode/vs/0's options array, a completely different OCF
surface that happens to share the English word "cooktop").
"""
from ..capabilities import common, cooktop as cooktop_caps, ignored
from ..capabilities import range as range_caps
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='induction_cooktop',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*common.POWER,
range_caps.COOKTOP_STATUS,
range_caps.COOKTOP_SPEC,
range_caps.COOKTOP_SAFETY,
range_caps.PROBE_STATUS,
cooktop_caps.PAIRED_HOOD_STATUS,
]),
)
@@ -0,0 +1,37 @@
"""Microwave device registry (combi and plain microwaves, issues #66/#121).
Shares the oven board family's cavity/cook-cycle resource shape, so the
operational-state, door, cloud-connected, and quick-recipe-display
Capability objects are reused directly from oven.py rather than duplicated.
Cooking mode, setpoint, cavity power level, and lamp are genuinely
different for this family (different mode vocabulary, different setpoint
bounds, an extra powerLevel field, a differently-named lamp option) and are
defined fresh in capabilities/microwave.py -- see that module's docstring.
Some combi units (built-in over-the-range microwaves, issues #137/#142)
also carry the vent fan's `/hood/fanspeed/vs/0` resource, in the exact same
shape a standalone range hood reports it in -- reused directly from
range_hood.py rather than duplicated. Unlike a standalone hood, this dump
has no sibling `/power/0` or `/power/vs/0` resource; fan.py's
LocalThingsRangeHoodFan falls back to treating fan speed 0 as off in that
case (see its `_speed_zero_is_off` check).
"""
from ..capabilities import common, ignored, microwave, oven, range_hood
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='microwave',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*common.POWER,
microwave.MICROWAVE_CAVITY,
microwave.MICROWAVE_SETPOINT,
microwave.MICROWAVE_MODE,
oven.OVEN_OPERATIONAL_STATE,
oven.OVEN_DOOR,
oven.OVEN_CONNECTED,
oven.OVEN_RECIPE_COOK,
range_hood.HOOD_FAN,
]),
)
@@ -15,5 +15,6 @@ REGISTRY = DeviceRegistry(
oven.OVEN_DOOR,
oven.OVEN_CONNECTED,
oven.OVEN_SPEC,
oven.OVEN_RECIPE_COOK,
]),
)
@@ -25,5 +25,6 @@ REGISTRY = DeviceRegistry(
range_caps.COOKTOP_STATUS,
range_caps.COOKTOP_SPEC,
range_caps.COOKTOP_SAFETY,
range_caps.COOKTOP_MONITORING,
]),
)
@@ -11,6 +11,7 @@ REGISTRY = DeviceRegistry(
range_hood.HOOD_ALARMS,
common.ENERGY_METER,
common.FIRMWARE_UPDATE,
range_hood.AFTER_RUN,
range_hood.HOOD_FAN,
range_hood.HOOD_LAMP,
range_hood.HOOD_FILTER,
@@ -33,8 +33,10 @@ REGISTRY = DeviceRegistry(
]),
pattern_capabilities=[
fridge.TEMP_CURRENT_GENERIC,
fridge.TEMP_SETPOINT_GENERIC,
fridge.TEMP_SETPOINT,
fridge.ICEMAKER_GENERIC,
fridge.DOOR_GENERIC,
fridge.KIMCHI_ZONE,
fridge.KIMCHI_DOOR_GENERIC,
],
)
@@ -0,0 +1,22 @@
"""Stick-vacuum clean/auto-empty station device registry (issue #131).
See capabilities/vacuum_station.py's module docstring for why this only
covers the station's own dustbag/dustbin/UV-sanitize state and not any
vacuum-body control (suction, battery, cleaning mode) -- the diagnostics
dump this was built from reports none of that.
"""
from ..capabilities import common, ignored, vacuum_station
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='vacuum_station',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*common.POWER,
vacuum_station.DUSTBAG,
vacuum_station.DUSTBAG_USAGE,
vacuum_station.DUSTBIN_SETTING,
vacuum_station.CLEANSTATION_STATUS,
]),
)
@@ -0,0 +1,20 @@
"""Water-purifier device registry (Samsung TP2X_WATERPURIFIER-class, issue #90).
"""
from ..capabilities import common, ignored, water_purifier
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='water_purifier',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
common.WATER_FILTER,
water_purifier.DISPENSE,
water_purifier.STATUS,
water_purifier.FAVORITE_CAPACITY,
water_purifier.FAVORITE_HOTWATER,
water_purifier.COFFEE,
water_purifier.LOCK,
*water_purifier.COVERAGE,
]),
)
@@ -15,6 +15,13 @@ issue #56's follow-up (five diagnostics dumps captured with the physical unit
set to Auto/Sleep/Low/Medium/High):
Light_On / Light_Off -- a plain on/off flag; MODE below models it as a
real switch, RMW-replacing just that one entry.
NOT the same polarity as the AC family's own
Light_On/Light_Off token on its own /mode/vs/0
(airconditioner._display_light_on) -- that one is
confirmed inverted (Light_Off means the panel is
lit) on live hardware. Same token name, same
resource name, different device type and
opposite meaning -- don't unify them.
Comode_Off -- read 'Off' on *every* one of the five dumps,
including High/Low/Medium/Auto -- confirms this
is NOT the fan-speed selector (ruling out the
@@ -32,20 +39,46 @@ set to Auto/Sleep/Low/Medium/High):
automatic side effect of sleep mode, e.g. a
display-dimming level, but that's still a guess).
/airflow/0 and /airflow/vs/0's `speed` still isn't modeled as a real
fan-speed control: across the same five dumps it read 0 for both Auto *and*
High, and 3 for Low/Medium *and* Sleep -- not a monotonic mapping to any
selectable level, and the dumps were all captured within about three minutes
of each other (only one poll cycle apart at this integration's 30s summary
interval), so the values may not have settled after each change before the
diagnostics snapshot was taken. Exposed read-only pending a confirmed,
stable capture -- see the issue #56 discussion for what's needed.
/airflow/0's `speed` is now a real fan-speed control (issue #56 follow-up).
The first round of five dumps above wasn't conclusive -- it read 0 for both
Auto *and* High, and 3 for Low/Medium *and* Sleep, likely because all five
were captured within about a minute of each other, faster than this
integration's own ~30s poll cycle could settle each change. A second round,
captured 60-90s apart per setting on two independent units, confirmed a
clean monotonic mapping instead: Auto=0, Sleep=1, Low=2, Medium=3, High=4.
AIRFLOW_GENERIC below builds an ordered-speed fan off that confirmed 0-4
range -- same SET_SPEED shape as range_hood.py's fan, mapping HA's
percentage steps straight onto the raw code, no named-preset table needed
(unlike the TP1X family's FAN, which exposes real named modes because its
board actually reports a supportedModes list to hang names off of).
/airflow/vs/0's vendor `speedLevel` is NOT used for the same purpose -- it
was unreliable on both units in that second round (Low/Medium collided on
one unit, stuck at 0 throughout on the other), so AIRFLOW_VS_FALLBACK below
stays a plain read-only diagnostic even after this change.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, SensorDesc, SwitchDesc
from .common import int_or_none, sensor_item_value
from ..entities import (
BinarySensorDesc, FanDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc,
)
from .common import filter_usage_percent, int_or_none, sensor_item_value
from .laundry import bool_option_exists, bool_option_value, option_value, option_write
# Newer TP1X_DA-AC-AIR-class boards (e.g. TP1X_DA-AC-AIR-01031_0000, issue
# #130) report fan modes directly on /mode/vs/0's top-level `modes`/
# `supportedModes` fields (Smart/Max/Mid/WindFree/Sleep) instead of packing
# everything into the options[] array the way the older ARTIK051_TVTL
# family above does -- that older family's /mode/vs/0 has no top-level
# supportedModes at all (see the module docstring's Comode_Off finding).
# Both board generations share the /mode/vs/0 href, so FAN and MODE below
# are mutually exclusive via this presence check rather than colliding.
HREF_MODE = '/mode/vs/0'
HREF_AIRFLOW = '/airflow/0'
def _has_top_level_modes(rep, resources):
return isinstance(rep.get('x.com.samsung.da.supportedModes'), (list, tuple))
_AIR_QUALITY_SENSORS = (
('dust', 'mdi:blur', 'Dust'),
('fine_dust', 'mdi:blur', 'FineDust'),
@@ -103,21 +136,52 @@ DEVICE_ACTIVE = Capability(
),
)
# OCF-native / vendor pair for fan speed+direction -- see module docstring for
# why these are read-only for now.
def _airflow_fan_write(payload, rep, href=None):
kind, value, *args = payload
if kind == 'power':
power_href = args[0] if args else '/power/vs/0'
if power_href == '/power/0':
return ['power', '0'], {'value': bool(value)}
return (['power', 'vs', '0'],
{'x.com.samsung.da.power': 'On' if value else 'Off'})
if kind == 'speed':
return ['airflow', '0'], {'speed': int(value)}
return None
# Confirmed via issue #56's second, properly-spaced round of diagnostics
# (two independent units, 60-90s apart per setting): /airflow/0's `speed` is
# a clean, monotonic 0-4 code across Auto/Sleep/Low/Medium/High, so it now
# backs a real ordered-speed fan (fan.py's LocalThingsAirflowFan, same
# SET_SPEED shape as the range hood's) instead of a read-only sensor --
# no named-preset table needed, since HA's percentage steps map onto the
# raw 0-4 code directly, the same way the range hood's numeric levels do.
# `direction` stays a plain diagnostic: every dump seen (both rounds, both
# units) reads 'Off' for it regardless of fan setting, so there's nothing
# confirmed to control there yet.
#
# Keyed 'airflow_fan', not 'fan' -- FAN below (bound to the shared
# /mode/vs/0 href) also uses 'fan', and BoundEntity's unique_id is built
# from key alone (entity.py's _key), not href. FAN and AIRFLOW_GENERIC are
# only *empirically* mutually exclusive (every dump seen has one board
# generation's shape or the other, never both), not architecturally
# enforced the way same-href caps are by _build()'s match_fn check -- a
# same key would collide if a future board ever reported both.
AIRFLOW_GENERIC = Capability(
href='/airflow/0',
href=HREF_AIRFLOW,
poll_tier='warm',
entities=(
SensorDesc(key='fan_speed_level', field='speed',
icon='mdi:fan',
state_class='measurement', entity_category='diagnostic'),
FanDesc(key='airflow_fan', field='speed', write_fn=_airflow_fan_write),
SensorDesc(key='fan_direction', field='direction',
icon='mdi:rotate-3d-variant',
entity_category='diagnostic'),
),
)
# Left exactly as a read-only fallback -- speedLevel is NOT the same
# confirmed-reliable field as /airflow/0's speed above (see module
# docstring): it collided Low/Medium on one unit and stuck at 0 throughout
# on the other in the same properly-spaced round.
AIRFLOW_VS_FALLBACK = Capability(
href='/airflow/vs/0',
match_fn=lambda rep, resources: '/airflow/0' not in resources,
@@ -149,6 +213,7 @@ def _light_write(payload, rep, href=None):
MODE = Capability(
href='/mode/vs/0',
poll_tier='warm',
match_fn=lambda rep, resources: not _has_top_level_modes(rep, resources),
entities=(
SwitchDesc(key='display_light', icon='mdi:led-on',
entity_category='config',
@@ -164,11 +229,200 @@ MODE = Capability(
),
)
def _fan_write(payload, rep, href=None):
kind, value, *args = payload
if kind == 'power':
# Targets whichever power href fan.py's _power_payload picked (the
# board may only report /power/0) -- a hardcoded vendor href here
# would silently no-op on such a board even though the entity's
# own is_on already falls back to reading it correctly.
power_href = args[0] if args else '/power/vs/0'
if power_href == '/power/0':
return ['power', '0'], {'value': bool(value)}
return (['power', 'vs', '0'],
{'x.com.samsung.da.power': 'On' if value else 'Off'})
if kind == 'mode':
return ['mode', 'vs', '0'], {'x.com.samsung.da.modes': [value]}
return None
def _first_fan_mode(rep):
"""Representative scalar for the fan entity in the flattened state
(golden/regression), mirroring airconditioner.py's own _first_mode --
the real entity computes its state from live coordinator reads."""
modes = rep.get('x.com.samsung.da.modes')
if isinstance(modes, (list, tuple)):
return modes[0] if modes else None
return modes
# Named preset modes (Smart/Max/Mid/WindFree/Sleep), not an ordered
# percentage -- WindFree/Smart/Sleep are named behaviors, not
# "faster/slower" positions relative to Max/Mid, so fan.py's entity for
# this only exposes PRESET_MODE, matching how the AC family's own named
# convenient modes are modeled as a preset rather than a speed number.
FAN = Capability(
href=HREF_MODE,
poll_tier='warm',
match_fn=_has_top_level_modes,
entities=(
FanDesc(key='fan', translation_key='air_purifier_fan',
rep_fn=_first_fan_mode, write_fn=_fan_write),
),
)
# ---------------------------------------------------------------------------
# TP1X_DA-AC-AIR-class additions (issue #130). This board reports several
# resources the older ARTIK051_TVTL family never did.
# ---------------------------------------------------------------------------
# Screen/indicator-panel on/off -- distinct from LIGHT below (ambient mood
# light): both report the same {mode, supportedModes: [On, Off]} shape on
# separate hrefs on this dump, so they're two independent physical controls,
# not a duplicate encoding of one.
DISPLAY = Capability(
href='/display/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='display', field='mode',
icon='mdi:monitor',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['display', 'vs', '0'],
{'mode': 'On' if p == 'On' else 'Off'})),
),
)
# Same filterUsage/filterCapacity/filterStatus shape as the AC family's own
# AIR_FILTER (airconditioner.py) -- confirmed normal/wash/replace values not
# seen on this one dump, so the option list there is reused as-is rather
# than re-deriving it from a single sample.
HEPA_FILTER = Capability(
href='/filter/hepafilter/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='hepa_filter_usage', rep_fn=filter_usage_percent,
unit='%', state_class='measurement',
icon='mdi:air-filter', entity_category='diagnostic'),
SensorDesc(key='hepa_filter_status', field='x.com.samsung.da.filterStatus',
device_class='enum',
options=('normal', 'wash', 'replace'),
translation_key='filter_status',
icon='mdi:air-filter', entity_category='diagnostic',
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
),
)
# Physical panel/cover status -- meaning of the one value seen ('Close') is
# plausible (the HEPA-filter access cover) but unconfirmed, and no
# supportedStatus list is present to check against -- exposed as a plain
# diagnostic sensor rather than an asserted binary_sensor polarity.
PANEL_STATUS = Capability(
href='/panel/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='panel_status', field='status',
icon='mdi:archive-outline', entity_category='diagnostic'),
),
)
# Pet-care filter mode -- a plain On/Off field with no vendor prefix, same
# convention as airconditioner.MUTE_ONCE.
PET_FILTER_ACTIVATION = Capability(
href='/petfilteractivation/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='pet_filter_activation', field='status',
icon='mdi:paw',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['petfilteractivation', 'vs', '0'],
{'status': 'On' if p == 'On' else 'Off'})),
),
)
# Sound mode/volume shapes look like laundry.py's SOUND_MODE/SOUND_VOLUME at
# a glance, but this board's actual values differ (supportedModes here is
# ['mute', 'buzzer'], not laundry's hardcoded voice/tone/mute; volume range
# is 0-3, not laundry's fixed 0-15) -- reusing those would either reject a
# valid write ('buzzer') or expose the wrong number range, so these are
# separate descriptors reading the live supported values instead of a
# hardcoded table.
SOUND_MODE = Capability(
href='/settings/sound/mode/vs/0',
poll_tier='cold',
entities=(
# Distinct translation_key from laundry.SOUND_MODE's shared
# 'sound_mode' catalog entry -- that one's state table is
# {voice, tone, mute}, but this board's supportedModes is
# {mute, buzzer}. Sharing the key would leave 'buzzer' unlabelled
# (falls through to the raw code) since the catalogs don't overlap.
SelectDesc(key='sound_mode', translation_key='air_purifier_sound_mode',
field='mode',
icon='mdi:volume-high',
entity_category='config',
options_field='supportedModes',
write_fn=lambda p, rep, href=None: (
['settings', 'sound', 'mode', 'vs', '0'], {'mode': p})),
),
)
# Read-only descriptor of which sound output the unit has -- only one value
# seen, no alternatives to select between.
SOUND_OUTPUT = Capability(
href='/settings/sound/output/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='sound_output', field='deviceType',
icon='mdi:volume-high', entity_category='diagnostic'),
),
)
SOUND_VOLUME = Capability(
href='/settings/sound/volume/vs/0',
poll_tier='cold',
entities=(
NumberDesc(key='sound_volume', field='level',
icon='mdi:volume-medium',
entity_category='config',
native_min_fn=lambda rep: int_or_none(rep.get('minLevel')) or 0,
native_max_fn=lambda rep: int_or_none(rep.get('maxLevel')) or 0,
step_fn=lambda rep: int_or_none(rep.get('resolution')) or 1,
value_fn=int_or_none,
write_fn=lambda p, rep, href=None: (
['settings', 'sound', 'volume', 'vs', '0'],
{'level': str(int(p))})),
),
)
# /humidity/0 and /humidity/vs/0 are empty {} on both dumps this family has
# been verified against -- covered here (not globally, per ignored.py's
# module docstring) since those hrefs collide with fridge/AC schemas
# elsewhere. Same two hrefs and reasoning as airconditioner.py's _AC_IGNORED.
#
# The next six hrefs (issue #130, TP1X_DA-AC-AIR board) are the exact same
# resources, same shapes, same reasoning as airconditioner.py's
# _AC_IGNORED on the shared DA-AC- board family -- duplicated here rather
# than promoted to the global ignored.py list, since that would require
# also removing them from _AC_IGNORED in the same change (a global entry
# colliding with a family-local bare Capability on the same href raises in
# _build()); left as a possible follow-up DRY cleanup.
COVERAGE = [
Capability(href='/humidity/0'),
Capability(href='/humidity/vs/0'),
Capability(href='/airlevelcheck/vs/0'), # periodic air-quality sensing scheduler plumbing
Capability(href='/availablecontrolsets/vs/0'), # opaque hex-encoded control-set bitmap
Capability(href='/da/softreset/vs/0'), # soft-reset trigger plumbing
Capability(href='/keepnormalstate/vs/0'), # internal keep-normal flag
Capability(href='/personality/presence/vs/0'), # presence-personalization plumbing (empty here)
Capability(href='/reserverulesets/vs/0'), # opaque hex-encoded schedule reservation blob
# Do-not-disturb/auto-sleep schedule (visible/startTime/endTime/
# useTimeSetting/functionState) -- every field reads its inert default
# on the only dump seen (times both '00:00:00', useTimeSetting/
# functionState both 'false'). Same "needs a multi-field schedule
# editor" treatment as fridge.py's /defrost/reservation/vs/0.
Capability(href='/dnd/autosleep/vs/0'),
]
@@ -16,6 +16,8 @@ by_type registry.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
from .common import filter_usage_percent, normalize_temp_unit
from .laundry import option_write
# ---------------------------------------------------------------------------
# Canonical AC resource hrefs. The climate entity (climate.py) binds the
@@ -33,13 +35,19 @@ HREF_TEMP_DESIRED = '/temperature/desired/0' # target_temperature (write ta
HREF_TEMP_CONTROL = '/temperature/control/vs/0' # target_temperature_step
HREF_WIND_STRENGTH = '/wind/strength/vs/0' # fan_mode
HREF_WIND_DIRECTION = '/wind/direction/vs/0' # swing_mode
# Newer boards (issue #126, TP1X_DA-AC-RAC-01011 WindFree variant) report no
# HREF_WIND_DIRECTION at all and instead carry a 2-axis oscillation resource
# (separate vertical/horizontal Swing|Fix toggles, each with its own angle).
# climate.py falls back to this when HREF_WIND_DIRECTION is absent, the same
# duality pattern as the OCF/vendor temperature channel below.
HREF_WIND_OSCILLATION = '/wind/oscillation/vs/0' # swing_mode fallback
HREF_CONVENIENT = '/mode/convenient/vs/0' # preset_mode
HREF_TEMPS_VS = '/temperatures/vs/0' # vendor temp fallback (items[] array)
CLIMATE_CONSUMED_HREFS = [
HREF_POWER, HREF_POWER_VS, HREF_TEMP_CURRENT, HREF_TEMP_DESIRED,
HREF_TEMP_CONTROL, HREF_TEMPS_VS, HREF_WIND_STRENGTH, HREF_WIND_DIRECTION,
HREF_CONVENIENT,
HREF_WIND_OSCILLATION, HREF_CONVENIENT,
]
@@ -50,16 +58,23 @@ def _num(v):
return None
def _filter_usage_percent(rep):
"""Filter usage as a percentage of rated capacity. The device reports
`filterUsage` as a raw count in `filterCapacityUnit` (Hours here, e.g.
100 of a 500 capacity), so a plain value with a '%' unit would be wrong --
normalize to used/capacity. Returns None when capacity is missing/zero."""
used = _num(rep.get('x.com.samsung.da.filterUsage'))
cap = _num(rep.get('x.com.samsung.da.filterCapacity'))
if used is None or not cap:
return None
return round(used / cap * 100)
def _temps_vs_item(rep):
"""First item of the vendor `/temperatures/vs/0` items[] array -- the
Tizen Lite board's only current-temperature source (see climate.py's
identical helper; duplicated rather than imported to avoid a
capabilities<->platform import cycle)."""
items = rep.get('x.com.samsung.da.items')
if isinstance(items, (list, tuple)) and items and isinstance(items[0], dict):
return items[0]
return {}
def _temps_vs_current(rep):
return _num(_temps_vs_item(rep).get('x.com.samsung.da.current'))
def _temps_vs_unit(rep):
return normalize_temp_unit(_temps_vs_item(rep).get('x.com.samsung.da.unit'), '°C')
def _first_mode(rep):
@@ -71,25 +86,100 @@ def _first_mode(rep):
return modes
def _mode_options(rep):
opts = rep.get('x.com.samsung.da.options')
return opts if isinstance(opts, (list, tuple)) else ()
def _has_display_light_option(rep, resources):
"""True when the panel light state is carried inside /mode/vs/0's options
blob (a `Light_On`/`Light_Off` token) rather than a dedicated /light/vs/0
switch. The two encodings are mutually exclusive across observed boards:
models exposing the /light/vs/0 switch (bound by DISPLAY_LIGHT below)
carry no Light_* option, so this entity only materialises on the boards
that would otherwise have no display-light entity at all."""
return any(isinstance(o, str) and o.startswith('Light_')
for o in _mode_options(rep))
def _display_light_on(rep):
"""Panel display light state from /mode/vs/0's options blob. The token is
INVERTED relative to its name -- confirmed by a live toggle test: with the
panel lit the option reads `Light_Off`, and with it dark it reads
`Light_On` (the flag really encodes "night/display-off mode active"). So
`Light_Off` -> light on, `Light_On` -> light off. Read-only from here; the
write below uses the device's own single-token merge (see option_write)."""
for o in _mode_options(rep):
if isinstance(o, str) and o.startswith('Light_'):
return o == 'Light_Off'
return None
def _display_light_write(payload, rep, href=None):
"""Toggle the panel light via a single-token /mode/vs/0 options write
('SingleCommand_1' is advertised in this family's /configuration/vs/0
airconOptionList; option_write's one-token merge is the same mechanism
air_purifier.py uses for its own Light switch). Polarity is inverted (see
_display_light_on): switching the lamp ON writes 'Light_Off', OFF writes
'Light_On'."""
token = 'Off' if payload == 'On' else 'On'
return (['mode', 'vs', '0'],
{'x.com.samsung.da.options': option_write('Light', token)})
def _climate_write(payload, rep, href=None):
"""Map a (kind, value) command from the climate platform to the
(path_segs, body) for that one sub-write. `value` is already the raw device
code (the platform maps HA<->device). async_send_command POSTs to path_segs,
so a single desc drives writes across power/mode/temperature/wind resources.
Read-modify-write safe: each write sends only its own field, leaving the
resource's other fields (e.g. /mode/vs/0's opaque `options` blob) untouched.
so a single desc drives writes across the power/mode/temperature/wind
resources.
Power goes to the vendor `/power/vs/0` (the OCF `/power/0` is absent on
most boards and a non-authoritative mirror where present -- vendor works
on every board). Temperature is board-dependent, so the platform picks the
channel and sends `temperature_ocf` (-> OCF `/temperature/desired/0`,
boards with the full OCF current+desired pair) or `temperature` (-> vendor
`/temperatures/vs/0`, boards without it). Mode/fan/swing/preset are always
the vendor `/x/vs/0` resources.
Each write sends only its own field(s), leaving the resource's other
fields (e.g. /mode/vs/0's opaque `options` blob, or the vendor temperature
item's current/minimum/maximum/unit) untouched -- the device merges the
rest itself, same contract as the options[] array (see
common.merge_items_field / merge_options_field, which keep the
coordinator's optimistic cache complete for the settle window instead of
this write echoing those fields back).
"""
kind, value = payload
if kind == 'power':
return (['power', '0'], {'value': bool(value)})
return (['power', 'vs', '0'],
{'x.com.samsung.da.power': 'On' if value else 'Off'})
if kind == 'mode':
return (['mode', 'vs', '0'], {'x.com.samsung.da.modes': [value]})
if kind == 'temperature_ocf':
return (['temperature', 'desired', '0'],
{'temperature': int(round(float(value)))})
if kind == 'temperature':
return (['temperature', 'desired', '0'], {'temperature': int(round(float(value)))})
# Vendor items[] array; only one item observed on every AC dump, id
# '0'. See the docstring above for why this doesn't echo current/
# minimum/maximum/unit back at the unit.
return (['temperatures', 'vs', '0'],
{'x.com.samsung.da.items': [
{'x.com.samsung.da.id': '0',
'x.com.samsung.da.desired': str(int(round(float(value))))}]})
if kind == 'fan':
return (['wind', 'strength', 'vs', '0'], {'x.com.samsung.da.modes': value})
if kind == 'swing':
return (['wind', 'direction', 'vs', '0'], {'x.com.samsung.da.modes': value})
if kind == 'oscillation':
# value is the HA swing_mode string ('off'/'vertical'/'horizontal'/
# 'both'); both axes are independent Swing|Fix toggles on this
# resource, so one HA value maps to a pair of fields written
# together (see climate.py's oscillation fallback).
return (['wind', 'oscillation', 'vs', '0'], {
'vertical': 'Swing' if value in ('vertical', 'both') else 'Fix',
'horizontal': 'Swing' if value in ('horizontal', 'both') else 'Fix',
})
if kind == 'preset':
return (['mode', 'convenient', 'vs', '0'], {'x.com.samsung.da.modes': value})
return None
@@ -101,6 +191,19 @@ CLIMATE = Capability(
entities=(
ClimateDesc(key='climate', translation_key='airconditioner',
rep_fn=_first_mode, write_fn=_climate_write),
# Display (panel) light switch, only on boards that encode it in
# /mode/vs/0's options instead of a /light/vs/0 switch (see
# _has_display_light_option). Shares the /mode/vs/0 href with the
# climate entity above -- same Capability, so no multi-cap
# discriminator is needed. /mode/vs/0 is OBSERVE-subscribed, so state
# updates on push; writes go through the single-token merge in
# _display_light_write. Shares the switch.display_light translation
# with DISPLAY_LIGHT (the /light/vs/0 switch on other boards) --
# mutually exclusive per href, so only one ever binds for a given unit.
SwitchDesc(key='display_light', rep_fn=_display_light_on,
exists_fn=_has_display_light_option,
write_fn=_display_light_write,
icon='mdi:led-on', entity_category='config'),
),
)
@@ -136,7 +239,7 @@ AIR_FILTER = Capability(
href='/filter/airdustfilter/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='air_filter_usage', rep_fn=_filter_usage_percent,
SensorDesc(key='air_filter_usage', rep_fn=filter_usage_percent,
unit='%', state_class='measurement',
icon='mdi:air-filter', entity_category='diagnostic'),
SensorDesc(key='air_filter_status', field='x.com.samsung.da.filterStatus',
@@ -199,6 +302,73 @@ CURRENT_LIMIT = Capability(
),
)
# Overload-response setting (issue #126, TP1X_DA-AC-RAC-01011 WindFree
# variant): `operation` toggles the feature and `mode` picks 'Alarm' vs
# 'PowerSaving' out of `supportedModes`, with a `savingTime` duration
# ('20'/'40'/'60' minutes) alongside. Plausible shape (compressor-overload
# alarm vs. automatic power throttling), but nothing in the dump confirms
# the exact behavioral difference between the two modes or whether writing
# 'operation' is safe on live HVAC hardware -- exposed read-only per the
# 'don't guess' rule, same precedent as CURRENT_LIMIT above.
ANOMALY_LOAD = Capability(
href='/anomalyload/vs/0',
poll_tier='cold',
entities=(
BinarySensorDesc(key='overload_protection_active', field='operation',
icon='mdi:flash-alert',
entity_category='diagnostic',
value_fn=lambda v: v == 'On'),
SensorDesc(key='overload_protection_mode', field='mode',
device_class='enum',
options=('alarm', 'powersaving'),
translation_key='overload_protection_mode',
icon='mdi:flash-alert', entity_category='diagnostic',
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
),
)
# The climate entity already surfaces current_temperature as a card
# attribute, but that's not enough for history graphs/automations/
# statistics -- issue #75 asked for a standalone sensor. Same OCF-standard-
# with-vendor-fallback shape as common.py's POWER_GENERIC/POWER_VS_FALLBACK
# pair: both share key='current_temperature_c' so only one ever binds
# (match_fn gates the vendor one off when the OCF resource is present).
CURRENT_TEMPERATURE = Capability(
href=HREF_TEMP_CURRENT,
poll_tier='warm',
entities=(
SensorDesc(key='current_temperature_c', field='temperature',
device_class='temperature', state_class='measurement',
unit_fn=lambda rep: normalize_temp_unit(rep.get('units'), '°C')),
),
)
CURRENT_TEMPERATURE_VS = Capability(
href=HREF_TEMPS_VS,
poll_tier='warm',
match_fn=lambda rep, resources: HREF_TEMP_CURRENT not in resources,
entities=(
SensorDesc(key='current_temperature_c', rep_fn=_temps_vs_current,
device_class='temperature', state_class='measurement',
unit_fn=_temps_vs_unit),
),
)
# Only the vendor resource's `fivepercentHumidity` (current reading, rounded
# to the nearest 5%) has live data on the issue #75 dump -- its `humidity`
# field, and the OCF-standard /humidity/0 resource entirely, both read a
# stuck "0" there and stay ignored per the 'don't guess' rule (see
# _AC_IGNORED below).
HUMIDITY = Capability(
href='/humidity/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='humidity', field='x.com.samsung.da.fivepercentHumidity',
device_class='humidity', state_class='measurement', unit='%',
value_fn=_num),
),
)
# ---------------------------------------------------------------------------
# AC-scoped coverage: the CLIMATE_CONSUMED_HREFS above (read by the climate
# entity) plus vendor duplicates / all-zero-ambiguous / plumbing resources.
@@ -221,8 +391,10 @@ _AC_IGNORED = [
# All-zero and ambiguously encoded on this model (2-value arrays); the
# 'don't guess' rule -- leave unmodeled rather than invent entities.
'/sensors/vs/0',
# Stuck at "0" on every dump seen -- HUMIDITY above reads the vendor
# resource's usable fivepercentHumidity field instead; this OCF-standard
# one has no corresponding live value confirmed yet.
'/humidity/0',
'/humidity/vs/0',
# Presence-personalization plumbing (empty item list here).
'/personality/presence/vs/0',
# --- TP1X/TP2X-class housekeeping / opaque blobs. These carry no
@@ -240,7 +412,14 @@ _AC_IGNORED = [
'/mds/absencemonitoring/vs/0', # motion-detection sensor plumbing (empty here)
'/mds/absencestate/vs/0', # motion-detection state (empty here)
'/remotedatacontrol/vs/0', # remote data-control session status
'/remotedeviceinfo/vs/0', # remote paired-device id list (empty didList here)
'/remotetemperature/vs/0', # external temp-sensor feed (unset on this unit)
# Manual airflow-step position (supportedModes Off/80/60/40/Power).
# Overlaps the /wind/direction swing control already on the climate card,
# and the meaning of the numeric steps vs. 'Power' isn't documented in the
# dump -- ignored per the 'don't guess' rule rather than modeled as a
# select whose write could confuse live HVAC hardware.
'/stepcontrol/vs/0',
'/reserverulesets/vs/0', # opaque hex-encoded schedule reservation blob
'/welcome/temperature/vs/0', # welcome-cooling plumbing
# System-AC-only (multi-indoor-unit commercial installs, e.g.
@@ -251,8 +430,11 @@ _AC_IGNORED = [
]
# Built as bare no-entity caps; folded into the AC registry (not global).
# HREF_TEMP_CURRENT and HREF_TEMPS_VS are excluded here -- CURRENT_TEMPERATURE
# / CURRENT_TEMPERATURE_VS above already cover those two with real entities.
COVERAGE = [
Capability(href=h, poll_tier='warm') for h in CLIMATE_CONSUMED_HREFS
if h not in (HREF_TEMP_CURRENT, HREF_TEMPS_VS)
] + [
Capability(href=h) for h in _AC_IGNORED
]
@@ -10,6 +10,9 @@ against live device dumps:
/water/consumption/vs/0 -> x.com.samsung.da.cumulativeWater
/filter/waterfilter/vs/0 -> x.com.samsung.da.filterUsage / filterStatus
"""
from datetime import datetime, timezone
from ..batch import is_stub_rep
from ..capability import Capability
from ..entities import (
BinarySensorDesc, ButtonDesc, SelectDesc, SensorDesc, SwitchDesc,
@@ -40,6 +43,35 @@ def wh_to_kwh(v):
return round(n / 1000.0, 2) if n is not None else None
def parse_iso_utc(raw):
"""ISO datetime defaulting to UTC when the string carries no timezone
of its own (this integration's convention for other bare ISO datetime
fields -- see washer.py's drum-clean-log comment). A few boards do
ship a 'Z'/offset suffix (fromisoformat parses that natively since
Python 3.11) -- only fill in UTC when parsing left the result naive,
rather than unconditionally overwriting whatever offset was parsed."""
if not raw:
return None
try:
dt = datetime.fromisoformat(raw)
except ValueError:
return None
return dt if dt.tzinfo is not None else dt.replace(tzinfo=timezone.utc)
def filter_usage_percent(rep):
"""Filter usage as a percentage of rated capacity. Several families
(AC, air purifier) report `filterUsage` as a raw count in
`filterCapacityUnit` (Hours, e.g. 100 of a 500 capacity), so a plain
value with a '%' unit would be wrong -- normalize to used/capacity.
Returns None when capacity is missing/zero."""
used = _num(rep.get('x.com.samsung.da.filterUsage'))
cap = _num(rep.get('x.com.samsung.da.filterCapacity'))
if used is None or not cap:
return None
return round(used / cap * 100)
def normalize_temp_unit(raw, default='°F'):
"""'C'/'Celsius' -> '°C', 'F'/'Fahrenheit' -> '°F'. Falls back to
`default` for any other/missing value. Shared by fridge.py and oven.py,
@@ -59,9 +91,21 @@ def _ml_to_l(v):
def _active_alarm_codes(items):
"""Join active alarm codes; skip retained rows Samsung leaves as Deleted.
Laundry boards keep a Deleted ErrorCode row in /alarms/vs/0 after the
condition clears (see WD7000B diagnostics). Surface only live alarms so
HA doesn't stick on a stale ErrorCode. Range-hood has its own stricter
helper that also drops ErrorCode_OFF.
"""
if not items or not isinstance(items, list):
return 'none'
codes = [i.get('x.com.samsung.da.code') for i in items if i.get('x.com.samsung.da.code')]
codes = [
i.get('x.com.samsung.da.code')
for i in items
if i.get('x.com.samsung.da.code')
and str(i.get('x.com.samsung.da.state', '')).lower() != 'deleted'
]
return ', '.join(codes) if codes else 'none'
@@ -92,6 +136,80 @@ def merge_options_field(cached, new_tokens):
return merged
def merge_items_field(cached, new_items):
"""Merge a partial x.com.samsung.da.items[]-style write (matched by
x.com.samsung.da.id) into a cached items array -- the read-side
counterpart of merge_options_field above, for the items[] shape instead
of the packed options[] shape.
Confirmed on hardware that a write only needs to carry the array item
with the changed id plus the field(s) being changed; the device merges
the rest itself (same fact as the options[] case, different array --
see airconditioner._climate_write's vendor temperature write). Fields
within the matched item are merged, not replaced outright, so a
setpoint-only write doesn't wipe current/minimum/maximum/unit from the
optimistic cache entry for the settle window. An id with no match in
`cached` is appended."""
merged = [dict(i) if isinstance(i, dict) else i for i in (cached or [])]
for new_item in new_items or ():
if not isinstance(new_item, dict):
continue
item_id = new_item.get('x.com.samsung.da.id')
for i, existing in enumerate(merged):
if isinstance(existing, dict) and existing.get('x.com.samsung.da.id') == item_id:
merged[i] = {**existing, **new_item}
break
else:
merged.append(new_item)
return merged
# /wm/setinfo/vs/0 -- laundry-family firmware capability flags. Present on
# washers, dryers, and dishwashers; absent on fridge/oven/AC. Static for the
# life of a given board, so reading them from the /device/0 seed (no dedicated
# poll_tier) is enough.
_SETINFO_HREF = '/wm/setinfo/vs/0'
_POWER_ON_OFF_FIELD = 'x.com.samsung.da.isModelSettingPowerOnOff'
_WITHOUT_SC_FIELD = 'x.com.samsung.da.isModelSettingWithoutSC'
def model_allows_power_on_off(resources: dict) -> bool:
"""True unless firmware explicitly declares remote power on/off unsupported.
`/wm/setinfo/vs/0`.`isModelSettingPowerOnOff` is `"false"` on many laundry
boards (washers/dryers): `/power/0` and `/power/vs/0` still report state,
but CoAP writes are ignored. Absent setinfo (non-laundry families) keeps
the writable switch -- current behavior.
"""
setinfo = resources.get(_SETINFO_HREF)
if setinfo is None:
return True
flag = setinfo.get(_POWER_ON_OFF_FIELD)
if flag is None:
return True
return str(flag).lower() != 'false'
def model_setting_without_sc(resources: dict) -> bool:
"""True when firmware declares settings writable without Smart Control.
`/wm/setinfo/vs/0`.`isModelSettingWithoutSC` is `"true"` on washers/dryers
that accept temperature/spin/cycle-option writes while remote control is
off. Cycle start/pause/stop still need Smart Control on those boards --
the flag name is settings-specific, not a blanket remote-control bypass.
"""
setinfo = resources.get(_SETINFO_HREF) or {}
return str(setinfo.get(_WITHOUT_SC_FIELD, '')).lower() == 'true'
def _power_switch_exists(rep, resources):
return model_allows_power_on_off(resources)
def _power_sensor_exists(rep, resources):
return not model_allows_power_on_off(resources)
def sensor_item_value(items, sensor_type, index=0):
"""Pull one reading out of a `/sensors/vs/0`-style items[] list -- each
item is `{type, value: [...]}`; `index` picks which slot of a possibly
@@ -128,10 +246,17 @@ def sensor_item_value(items, sensor_type, index=0):
POWER_GENERIC = Capability(
href='/power/0',
entities=(
# Writable when firmware allows remote power; otherwise a read-only
# binary_sensor with the same key keeps HA state without a dead switch.
SwitchDesc(key='power_switch', field='value',
value_fn=lambda v: bool(v),
exists_fn=_power_switch_exists,
write_fn=lambda p, rep, href=None: (
['power', '0'], {'value': p == 'On'})),
BinarySensorDesc(key='power_switch', field='value',
device_class='power',
value_fn=lambda v: bool(v),
exists_fn=_power_sensor_exists),
),
)
@@ -141,9 +266,14 @@ POWER_VS_FALLBACK = Capability(
entities=(
SwitchDesc(key='power_switch', field='x.com.samsung.da.power',
value_fn=lambda v: v == 'On',
exists_fn=_power_switch_exists,
write_fn=lambda p, rep, href=None: (
['power', 'vs', '0'],
{'x.com.samsung.da.power': 'On' if p == 'On' else 'Off'})),
BinarySensorDesc(key='power_switch', field='x.com.samsung.da.power',
device_class='power',
value_fn=lambda v: v == 'On',
exists_fn=_power_sensor_exists),
),
)
@@ -192,6 +322,20 @@ def remote_control_enabled(resources: dict) -> bool:
return True
def remote_control_required_for_write(resources: dict, bound_href: str) -> bool:
"""Whether a write to bound_href should be gated on Smart Control.
When isModelSettingWithoutSC is true, laundry firmware accepts settings
writes (wash temp, spin, course options, buzzer, ...) with remote
control off, but cycle start/pause/stop on /operational/state still
need Smart Control. Absent that flag, keep the historical blanket gate.
"""
if not model_setting_without_sc(resources):
return True
href = bound_href or ''
return href.startswith('/operational/state')
REMOTE_CONTROL_GENERIC = Capability(
href='/remotectrl/0',
poll_tier='warm',
@@ -237,32 +381,35 @@ _DEAD_INSTANTANEOUS_POWER = '-500'
ENERGY_METER = Capability(
href='/energy/consumption/vs/0',
entities=(
# `not rep` keeps the empty-{} stub carve-out (see entity._is_included):
# `is_stub_rep(rep)` keeps the stub carve-out (see entity._is_included):
# an explicit exists_fn otherwise bypasses it, which would drop the
# entity when /device/0 returns a not-yet-fetched stub. On a populated
# rep, hide power only for the dead sentinel or an absent field.
# entity when /device/0 returns a not-yet-fetched stub. A genuinely
# empty {} rep is NOT a stub -- it's the device's confirmed (if empty)
# answer, so it falls through to the normal field/sentinel checks like
# any populated rep. On a populated rep, hide power only for the dead
# sentinel or an absent field.
SensorDesc(key='power_watts', field='x.com.samsung.da.instantaneousPower',
device_class='power', state_class='measurement',
unit='W', value_fn=clamp_power,
exists_fn=lambda rep, resources: not rep or (
exists_fn=lambda rep, resources: is_stub_rep(rep) or (
rep.get('x.com.samsung.da.instantaneousPower')
not in (None, _DEAD_INSTANTANEOUS_POWER))),
SensorDesc(key='energy_kwh', field='x.com.samsung.da.cumulativePower',
device_class='energy',
state_class='total_increasing', unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.cumulativePower' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.cumulativePower' in rep)),
# cumulativeConsumption is a second, independently-varying running
# total alongside cumulativePower -- some fridges (issue #26) report
# both. Self-gates off where only cumulativePower is present. `not
# rep or` keeps the same empty-{} stub carve-out as power_watts/
# both. Self-gates off where only cumulativePower is present. The
# `is_stub_rep(rep) or` keeps the same stub carve-out as power_watts/
# energy_kwh above -- without it, an exists_fn permanently drops the
# entity if setup happens to land on a not-yet-fetched stub.
SensorDesc(key='power_energy_kwh', field='x.com.samsung.da.cumulativeConsumption',
device_class='energy',
state_class='total_increasing', unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.cumulativeConsumption' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.cumulativeConsumption' in rep)),
# AI Energy Mode's lifetime savings estimate vs. an unoptimized
# baseline -- present on some models (e.g. TP1X_REF_21K, issue #21/
# #27) and absent on others (issue #20/#26), unlike cumulativePower.
@@ -270,7 +417,7 @@ ENERGY_METER = Capability(
device_class='energy',
state_class='total_increasing', unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.cumulativeSavedPower' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.cumulativeSavedPower' in rep)),
# Monthly billing-cycle totals -- the completed prior month and the
# in-progress current month. Not ever-increasing (each resets at
# month boundary), so no state_class.
@@ -278,12 +425,12 @@ ENERGY_METER = Capability(
device_class='energy',
unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.monthlyConsumption' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.monthlyConsumption' in rep)),
SensorDesc(key='energy_this_month_kwh', field='x.com.samsung.da.thismonthlyConsumption',
device_class='energy',
unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.thismonthlyConsumption' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.thismonthlyConsumption' in rep)),
),
)
@@ -356,7 +503,7 @@ AI_ENERGY_LEVEL = Capability(
href='/energy/ailevel/vs/0',
poll_tier='cold',
entities=(
# No `not rep` stub carve-out on either side, unlike most exists_fn
# No is_stub_rep carve-out on either side, unlike most exists_fn
# gates in this file -- entity creation only ever runs once, against
# whichever snapshot happens to be current the moment platforms are
# set up (see entity._is_included / __init__.py's
@@ -419,7 +566,7 @@ SELF_CHECK = Capability(
icon='mdi:alert-circle-outline',
entity_category='diagnostic',
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.error' in rep),
is_stub_rep(rep) or 'x.com.samsung.da.error' in rep),
value_fn=lambda v: (', '.join(v) if v else None) if isinstance(v, list) else v),
ButtonDesc(key='selfcheck_start', field='', payload='Start',
icon='mdi:play-circle-outline',
@@ -9,6 +9,7 @@ cooktop must not be remotely ignited by an automation.
import re
from ..batch import is_stub_rep
from ..capability import Capability
from ..entities import BinarySensorDesc, SensorDesc
@@ -97,7 +98,7 @@ COOKTOP_MODE = Capability(
options, f'OperationState{slot}'
),
exists_fn=lambda rep, resources, slot=slot: (
not rep or _option_value(
is_stub_rep(rep) or _option_value(
rep.get('x.com.samsung.da.options'),
f'OperationState{slot}',
) is not None
@@ -0,0 +1,85 @@
"""Capabilities for the Samsung dehumidifier family (TP1X_DA_AC_DHM-class,
issue #88, model AY18CG7500GED).
Same DA_AC_ board family as the room-AC models in airconditioner.py (shared
power/energy/filter/auto-clean/mute-once resource shapes), but target
humidity -- not temperature -- is this device's primary control, and there
is no climate composite: power, mode, and humidity are exposed as separate
entities rather than folded into one card.
"""
from ..capability import Capability
from ..entities import NumberDesc, SelectDesc, SensorDesc
from .common import int_or_none
def _first_mode(rep):
"""Representative scalar for the operating-mode select. `modes` is a
single-element list on every dump seen so far, mirroring
airconditioner._first_mode's handling of the same field shape."""
modes = rep.get('x.com.samsung.da.modes')
if isinstance(modes, (list, tuple)):
return modes[0] if modes else None
return modes
MODE = Capability(
href='/mode/vs/0',
poll_tier='warm',
entities=(
SelectDesc(key='operating_mode', rep_fn=_first_mode,
icon='mdi:tune-variant',
options_field='x.com.samsung.da.supportedModes',
write_fn=lambda p, rep, href=None: (
['mode', 'vs', '0'], {'x.com.samsung.da.modes': [p]})),
),
)
# Target humidity is this device's primary control (the issue-#88 dump's
# equivalent of a thermostat setpoint). No min/max range field is present in
# any dump seen so far -- native_min/native_max are deliberately left unset
# so the number entity falls back to HA's own 0-100 default, the natural
# bound for a percentage field, rather than a bound guessed from one unit's
# spec sheet (see the adding-device-support skill's "never hard-code the one
# dump's values" section). Step comes live from the device's own `increment`
# field.
HUMIDITY = Capability(
href='/humidity/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='humidity', field='x.com.samsung.da.humidity',
device_class='humidity', unit='%', state_class='measurement',
value_fn=int_or_none),
NumberDesc(key='target_humidity', field='x.com.samsung.da.desiredHumidity',
device_class='humidity', unit='%',
icon='mdi:water-percent',
entity_category='config',
value_fn=int_or_none,
step_fn=lambda rep: int_or_none(rep.get('increment')) or 1,
write_fn=lambda p, rep, href=None: (
['humidity', 'vs', '0'],
{'x.com.samsung.da.desiredHumidity': str(int(round(float(p))))})),
),
)
# ---------------------------------------------------------------------------
# Dehumidifier-scoped coverage: vendor plumbing with no user-actionable state
# or no documented write contract, following the same 'don't guess' rule as
# airconditioner._AC_IGNORED (this is the same DA_AC_ board family). Not in
# the global ignored.IGNORED since some of these hrefs collide with other
# families' schemas.
# ---------------------------------------------------------------------------
_DHM_IGNORED = [
'/availablecontrolsets/vs/0', # opaque hex-encoded control-set bitmap (id: DHM)
'/da/softreset/vs/0', # soft-reset trigger plumbing
'/keepnormalstate/vs/0', # internal keep-normal flag
'/personality/presence/vs/0', # presence-personalization plumbing (empty item value)
'/reserverulesets/vs/0', # opaque hex-encoded schedule reservation blob
'/sensors/vs/0', # empty {} on this dump
'/welcome/humidity/vs/0', # welcome-mode plumbing (requestId/operatingStatus, inert)
# Only supportedModes ([Off, Sleep]) is present -- no live "current
# value" field on this dump to confirm the read/write contract, so per
# the 'don't guess' rule this is left unmodeled rather than assumed.
'/mode/convenient/vs/0',
]
COVERAGE = [Capability(href=h) for h in _DHM_IGNORED]
@@ -42,7 +42,10 @@ DRYER_SETTINGS = Capability(
# under entity.select.dryer_cycle (Table_03, DV5000-class, captured
# 2026-05-29). Codes 0x21 and 0x4C appear in the issue #14 DV90BB5245AES1
# editCourseList but aren't identified yet -- they render as the raw code
# until named. The /st/dryercourse/vs/0 resource re-encodes the same selected
# until named. Codes '01' Normal and '06' Time dry were confirmed on a
# DVE50A8600V/A3 (also Table_03) by selecting each cycle on the physical
# appliance and reading back the raw code from the entity's state (issue
# #80). The /st/dryercourse/vs/0 resource re-encodes the same selected
# course and is ignored (ignored.py) -- the mirror of how /st/washercourse/vs/0
# is ignored for washers.
DRYER_COURSE = Capability(
@@ -62,7 +62,38 @@ TEMP_CURRENT_GENERIC = Capability(
),
)
TEMP_SETPOINT_GENERIC = Capability(
def _temp_setpoint_write(p, rep, href=None, resources=None):
"""Write temperature — prefer vendor /temperatures/vs/0 when available,
fall back to direct OCF /temperature/desired/ write otherwise.
Samsung fridges expose both OCF-standard /temperature/desired/* and vendor
/temperatures/vs/0. On some models only the vendor path commits the change;
on others both work. Using the vendor path when present is always correct.
Item IDs follow the Samsung convention: "0" = Freezer, "1" = Fridge/Cooler.
"""
if not href:
return None
if resources and '/temperatures/vs/0' in resources:
if '/cooler/' in href:
item_id = '1'
elif '/freezer/' in href:
item_id = '0'
else:
return None
return (
['temperatures', 'vs', '0'],
{'x.com.samsung.da.items': [
{'x.com.samsung.da.id': item_id,
'x.com.samsung.da.desired': str(int(round(float(p))))}
]}
)
return (
[s for s in href.strip('/').split('/') if s],
{'temperature': int(round(float(p)))}
)
TEMP_SETPOINT = Capability(
href=None,
href_prefix='/temperature/desired/',
strip_prefix_in_key=True,
@@ -73,10 +104,7 @@ TEMP_SETPOINT_GENERIC = Capability(
use_instance_name=True, device_class='temperature', unit_fn=_temp_unit,
native_min=-20.0, native_max=50.0,
range_field='range', entity_category='config',
write_fn=lambda p, rep, href=None: (
[s for s in href.strip('/').split('/') if s],
{'temperature': int(round(float(p)))}
) if href else None),
write_fn=_temp_setpoint_write),
),
)
@@ -562,8 +590,17 @@ FLEX_ZONE = Capability(
translation_key='flex_zone_mode',
entity_category='config',
options_field='x.com.samsung.da.supportedOptions',
exists_fn=lambda rep, resources: bool(
rep.get('x.com.samsung.da.supportedOptions')),
# A nonempty supportedOptions alone isn't sufficient: the
# kimchi-refrigerator family (issue #26) also populates
# /mode/vs/0's modes/supportedOptions with real data, but
# its tokens carry a "_[n]:[n]" parameter suffix on
# supportedOptions that modes never repeats, so no item
# ever overlaps -- the RF9000/Bespoke-class overlap this
# capability was built for never happens there. Require an
# actual resolvable value instead of just a populated
# list, so this stays absent on that family rather than
# showing a select permanently stuck on "unknown".
exists_fn=lambda rep, resources: _flex_zone_current(rep) is not None,
rep_fn=_flex_zone_current,
write_fn=_flex_zone_write),
),
@@ -573,15 +610,126 @@ FLEX_ZONE = Capability(
# Generic door pattern capability (href=None — use as pattern_cap only)
# ---------------------------------------------------------------------------
def _door_open_state(rep):
"""Most /door/* resources report bare `openState`, but the
ARTIK051_DONGLE_REF family's /door/onedoorfreezer/vs/0 (issues #77, #83)
reports the vendor-prefixed `x.com.samsung.da.openState` instead. This
capability still binds either way (href_prefix match doesn't care about
field names), but a plain `field=` lookup against the wrong key means
the entity exists and is permanently unavailable -- check both."""
v = rep.get('openState')
if v is None:
v = rep.get('x.com.samsung.da.openState')
return v == 'Open'
DOOR_GENERIC = Capability(
href=None,
href_prefix='/door/',
poll_tier='hot',
entities=(
BinarySensorDesc(key='open', field='openState',
BinarySensorDesc(key='open', rep_fn=_door_open_state,
translation_key='instance_open',
use_instance_name=True, device_class='door',
value_fn=lambda v: v == 'Open'),
use_instance_name=True, device_class='door'),
),
)
# ---------------------------------------------------------------------------
# Kimchi refrigerator compartments (TP2X_REF_20K-class 3-compartment kimchi
# units, issue #26) -- top/middle/bottom each report their own storage mode
# plus a ripening status/timer on /status/kimchi/<slot>/vs/0, all three in
# an identical shape; modeled as a pattern capability the same way
# DOOR_GENERIC/TEMP_CURRENT_GENERIC above are, deriving the per-compartment
# key and {instance_name} from the href's top/middle/bottom segment. Only
# the top compartment's door has been seen reported separately (kimchidoors);
# middle/bottom apparently have no contact switch of their own, so that's
# its own narrower pattern cap rather than assumed universal.
#
# The same state is also mirrored -- packed into single tokens like
# "KIMCHIT_KIMCHI_STORAGE_NORMAL" (T/M/B prefix per compartment) with
# bracketed parameters -- on /mode/vs/0, the same resource FLEX_ZONE reads
# for RF9000-class fridges. /status/kimchi/<slot>/vs/0's plain currentMode/
# supportMode fields are unpacked and self-describing, so that's what this
# binds to instead.
#
# Write path is unconfirmed (no live write against a real unit) -- same
# "write the same field back to the entity's own href" convention as
# PANTRY_ZONE/BEVERAGE_ZONE above, first real-world write is also the test.
#
# translations/en.json's kimchi_zone_mode state labels were translated
# directly from the reporter's own (Korean-language) SmartThings app
# screenshots, not guessed from the codes or from their English paraphrase.
# Cross-checking the screenshots against supportMode confirms the on-screen
# option order matches the array order everywhere it's verifiable: the top
# compartment's freezer triplet (표준/강냉/약냉 = Standard/Strong/Weak, at
# -19/-21/-17°C) lines up 1:1 with STORAGE_FREEZER_NORMAL/COLD/WARM, and the
# middle/bottom compartments' full 8-entry kimchi-storage list, 2-entry
# ripening list, and 4-entry custom-storage list each line up 1:1 with their
# supportMode order too -- so COLD/WARM consistently means Strong/Weak (a
# colder or warmer preset around the NORMAL setpoint) everywhere that suffix
# appears, including on STORAGE_FRIDGE_* and the low-salt kimchi variants,
# which weren't directly screenshotted but share the same NORMAL/COLD/WARM
# vocabulary as the two confirmed triplets. CRUNFCH (아삭, "crisp/crunchy")
# and BUY (구입, "purchased") are also confirmed exact matches, not
# abbreviation guesses.
# ---------------------------------------------------------------------------
def _kimchi_mode_write(p, rep, href=None):
if not href or p not in (rep.get('x.com.samsung.da.supportMode') or ()):
return None
return [s for s in href.strip('/').split('/') if s], {
'x.com.samsung.da.currentMode': p,
}
KIMCHI_ZONE = Capability(
href=None,
href_prefix='/status/kimchi/',
strip_prefix_in_key=True,
poll_tier='warm',
entities=(
SelectDesc(key='mode', field='x.com.samsung.da.currentMode',
use_instance_name=True, icon='mdi:fridge-outline',
translation_key='kimchi_zone_mode',
entity_category='config',
options_field='x.com.samsung.da.supportMode',
write_fn=_kimchi_mode_write),
SensorDesc(key='ripening_status', field='x.com.samsung.da.ripeStatus',
use_instance_name=True, icon='mdi:progress-clock',
translation_key='kimchi_ripening_status',
entity_category='diagnostic'),
SensorDesc(key='ripening_remaining', field='x.com.samsung.da.ripeRemaintime',
use_instance_name=True, icon='mdi:timer-sand',
translation_key='kimchi_ripening_remaining',
entity_category='diagnostic',
# No dump has this nonzero (ripeStatus is always "Off" so
# far) -- device-reported unit unconfirmed, so this stays
# a bare number rather than asserting minutes or hours.
value_fn=_int),
SensorDesc(key='rack_count', field='x.com.samsung.da.rackCount',
use_instance_name=True, icon='mdi:tray-full',
translation_key='kimchi_rack_count',
entity_category='diagnostic', enabled_default=False,
value_fn=_int),
),
)
KIMCHI_DOOR_GENERIC = Capability(
href=None,
href_prefix='/kimchidoors/',
strip_prefix_in_key=True,
poll_tier='hot',
entities=(
# Not deduped against DOORS_FALLBACK below: on the one reporter
# (refrigerator_tp2x_ref_20k_kimchi) this binds alongside, the
# /doors/vs/0 aggregate carries a single generic item (id "4", no
# /door/<instance> siblings for DOORS_FALLBACK's match_fn to see)
# that doesn't share this compartment's "top" instance numbering --
# a distinct main-cabinet door, not this kimchi drawer's own contact
# switch reported twice.
BinarySensorDesc(key='open', rep_fn=_door_open_state,
translation_key='instance_open',
use_instance_name=True, device_class='door'),
),
)
@@ -131,4 +131,12 @@ IGNORED: list[Capability] = [
# parallel write-capable capability around an unverified generic OCF
# write contract.
Capability(href='/operational/state/0'),
# Cooktop guided-cooking/recipe status (issue #86, TP1X_DA-KS-COOKTOP
# family): sequenceNumber, operationBurnerNumber, a stageInfo block, and
# a textData.menu string -- every field empty/zero on the only dump
# seen so far (device idle, no guided-cooking program active). Same
# "don't guess" treatment as the microwave family's /recipe/cook/vs/0.
# Revisit if a dump with an active recipe surfaces.
Capability(href='/cooktop/recipe/status/vs/0'),
]
@@ -0,0 +1,195 @@
"""Capabilities for the Samsung microwave family (TP1X_DA-KS-MICROWAVE-*
class boards, both combi units and plain microwaves).
Shares the oven board family's cavity/cook-cycle resource shape
(`/operational/state/vs/0`, `/doors/vs/0`, `/connected/vs/0`,
`/recipe/cook/vs/0`) -- those Capability objects are reused directly from
oven.py in by_type/microwave.py rather than duplicated. What's genuinely
different from an oven, and defined fresh here:
* Cooking-mode vocabulary: MicroWave/MicroWaveGrill/MicroWaveConvection/
KeepWarm never appear on an oven's /mode/vs/0, and this family spells
some shared-sounding modes differently than oven.py's own constants
(e.g. 'AirFryer', not oven.py's 'AirFry') -- a distinct SelectDesc and
mode list, not oven.OVEN_MODE.
* Setpoint bounds: this family's Convection/MicroWaveConvection modeSpec
(issue #121's MW7300B dump) reports 40-200 C / step 5, not oven.py's
30-270 C range (verified against a different, bake-oven-class board).
* Cavity: /oven/vs/0 here also carries a `powerLevel` field (100W-900W
on the MicroWave mode's powerListData) that plain ovens don't report --
exposed as its own sensor.
* Lamp: this family's option-array token is bare 'Lamp' (issue #137's
'Lamp_Off'), not oven.py's 'UpperLamp' -- and it's genuinely absent on
the combi dump (issue #121), so it's gated with exists_fn rather than
assumed universal like oven.py's lamp switch.
Note: cooking-mode writes are unproven here, same caveat as oven.py's
OVEN_MODE -- exposed as a SelectDesc for fidelity, first real-world write
is also the test.
"""
from ..capability import Capability
from ..entities import NumberDesc, SelectDesc, SensorDesc, SwitchDesc
from .common import int_or_none, normalize_temp_unit
from .laundry import option_value, option_write
# ---------------------------------------------------------------------------
# Constants
# ---------------------------------------------------------------------------
# Union of every mode seen across the two known dumps: issue #121's combi
# MW7300B (NoOperation/Autocook/AutocookCustom/Convection/AirFryer/Grill/
# MicroWave/MicroWaveGrill/MicroWaveConvection/Deodorization) and issue #137's
# plain ME7500D (NoOperation/MicroWave/Autocook/KeepWarm). No dump has shown
# every mode below on one device -- the select surfaces whatever a given
# board's own /mode/vs/0 supportedModes reports; an entry here that a device
# never sends just never gets picked.
_MICROWAVE_MODES = (
'NoOperation',
'MicroWave',
'MicroWaveGrill',
'MicroWaveConvection',
'Convection',
'AirFryer',
'Grill',
'Autocook',
'AutocookCustom',
'Deodorization',
'KeepWarm',
)
# Convection/MicroWaveConvection modeSpec on issue #121's dump: tempMinC 40,
# tempMaxC 200, tempIntervalC 5. No Fahrenheit dump exists for this family;
# unlike oven.py's own SETPOINT_MIN_F/MAX_F/STEP_F (independently verified
# against issue #44's range dump), there's nothing to verify a microwave's
# Fahrenheit bounds against, so this module only exposes the setpoint
# control when the live unit is Celsius (see _microwave_temp_unit below).
SETPOINT_MIN_C = 40
SETPOINT_MAX_C = 200
SETPOINT_STEP_C = 5
def _microwave_temp_unit(rep):
"""Same shape as oven.py's _oven_temp_unit: /temperatures/vs/0 items[]
carries a per-item x.com.samsung.da.unit field. Both known dumps for
this family report 'Celsius'; kept live rather than hardcoded per the
fridge/oven convention (issue #7)."""
items = rep.get('x.com.samsung.da.items') or []
unit = items[0].get('x.com.samsung.da.unit') if items else None
return normalize_temp_unit(unit, default='°C')
def _setpoint_write(p, rep, href=None):
"""RMW write to /temperatures/vs/0 items array -- unproven for this
family (no live write confirmed against a real unit), same "exposed for
fidelity" caveat as the mode select."""
try:
temp = float(p)
except (TypeError, ValueError):
return None
temp_i = int(round(temp / SETPOINT_STEP_C) * SETPOINT_STEP_C)
if not (SETPOINT_MIN_C <= temp_i <= SETPOINT_MAX_C):
return None
items = rep.get('x.com.samsung.da.items')
if not items:
return None
items = [dict(it) for it in items]
items[0]['x.com.samsung.da.desired'] = str(temp_i)
return ['temperatures', 'vs', '0'], {'x.com.samsung.da.items': items}
def _power_level_watts(v):
"""'100W'..'900W' (issue #121) or a bare '0' (issue #137) -> int watts."""
if v is None:
return None
s = str(v).strip()
if s.upper().endswith('W'):
s = s[:-1]
return int_or_none(s)
def _mode_write(p, rep, href=None):
if p not in _MICROWAVE_MODES:
return None
return ['mode', 'vs', '0'], {'x.com.samsung.da.modes': [p]}
def _sound_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
if not rep.get('x.com.samsung.da.options'):
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': option_write('Sound', p),
}
def _lamp_exists(rep, resources):
return option_value(rep.get('x.com.samsung.da.options'), 'Lamp') is not None
def _lamp_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
if not rep.get('x.com.samsung.da.options'):
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': option_write('Lamp', p),
}
# ---------------------------------------------------------------------------
# Capabilities
# ---------------------------------------------------------------------------
MICROWAVE_CAVITY = Capability(
href='/oven/vs/0',
poll_tier='hot',
entities=(
SensorDesc(key='cavity_state', field='x.com.samsung.da.state'),
SensorDesc(key='power_level', field='x.com.samsung.da.powerLevel',
unit='W', value_fn=_power_level_watts),
),
)
MICROWAVE_SETPOINT = Capability(
href='/temperatures/vs/0',
poll_tier='hot',
entities=(
NumberDesc(key='setpoint', field='x.com.samsung.da.items',
device_class='temperature', unit_fn=_microwave_temp_unit,
native_min=float(SETPOINT_MIN_C), native_max=float(SETPOINT_MAX_C),
step=float(SETPOINT_STEP_C), icon='mdi:thermometer-chevron-up',
exists_fn=lambda rep, resources: _microwave_temp_unit(rep) == '°C',
value_fn=lambda items: int_or_none(
(items[0].get('x.com.samsung.da.desired') if items else None)),
write_fn=_setpoint_write),
SensorDesc(key='current_temp_c', field='x.com.samsung.da.items',
device_class='temperature',
state_class='measurement', unit_fn=_microwave_temp_unit,
value_fn=lambda items: int_or_none(
(items[0].get('x.com.samsung.da.current') if items else None))),
),
)
MICROWAVE_MODE = Capability(
href='/mode/vs/0',
poll_tier='warm',
entities=(
# SelectDesc first — test_microwave_mode_options_nonempty uses entities[0]
SelectDesc(key='cooking_mode', field='x.com.samsung.da.modes',
icon='mdi:tune',
options=_MICROWAVE_MODES,
value_fn=lambda v: v[0] if v else None,
write_fn=_mode_write),
SwitchDesc(key='sound', field='x.com.samsung.da.options',
icon='mdi:volume-high',
entity_category='config',
value_fn=lambda opts: option_value(opts, 'Sound') == 'On',
write_fn=_sound_write),
SwitchDesc(key='lamp', field='x.com.samsung.da.options',
icon='mdi:track-light',
exists_fn=_lamp_exists,
value_fn=lambda opts: option_value(opts, 'Lamp') == 'On',
write_fn=_lamp_write),
),
)
@@ -338,6 +338,12 @@ OVEN_CONNECTED = Capability(
# fields worth exposing.
OVEN_SPEC = Capability(href='/oven/spec/vs/0')
# Quick-recipe display blob (combi microwave, issue #121) -- a JSON-encoded
# string (language/menu/servingSize/option) with every field blank on the
# only dump seen, and no documented write contract. No entity to bind per
# the 'don't guess' rule; a bare Capability still marks the href covered.
OVEN_RECIPE_COOK = Capability(href='/recipe/cook/vs/0')
OVEN_MODE = Capability(
href='/mode/vs/0',
poll_tier='warm',
@@ -24,7 +24,8 @@ write pattern already proven safe elsewhere in this codebase (oven setpoint,
icemaker toggles).
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, SelectDesc, SensorDesc
from ..entities import BinarySensorDesc, SelectDesc, SensorDesc, SwitchDesc
from .common import normalize_temp_unit
# Observed as high as 4 (this issue's dump); user-reported hardware with 5
# burners exists. Kept a little above both since exists_fn gates unused
@@ -52,6 +53,10 @@ def _burner_hot_surface_fn(i):
return lambda burner_list: get_state(burner_list) not in (None, 'normal')
def _burner_pan_detection_fn(i):
return lambda burner_list: bool(_burner_field_fn(i, 'panDetection')(burner_list))
def _power_level_options(resources):
spec = resources.get('/cooktop/spec/vs/0') or {}
return list(spec.get('supportedPowerLevelList') or [])
@@ -100,15 +105,44 @@ def _burner_entities(i):
translation_placeholders={'number': str(n)},
exists_fn=exists,
value_fn=_burner_hot_surface_fn(i)),
BinarySensorDesc(key=f'burner_{i}_pan_detected', field='burnerList',
icon='mdi:pot',
translation_key='burner_pan_detected',
translation_placeholders={'number': str(n)},
entity_category='diagnostic',
exists_fn=exists,
value_fn=_burner_pan_detection_fn(i)),
)
def _child_lock_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
return ['cooktop', 'status', 'vs', '0'], {'childLock': p.lower()}
COOKTOP_STATUS = Capability(
href='/cooktop/status/vs/0',
poll_tier='hot',
entities=(
SensorDesc(key='cooktop_state', field='operationState',
icon='mdi:pot-steam'),
# The cooktop section's own on/off (issue #86) -- distinct from
# common.POWER's /power/0 or /power/vs/0, which some boards in this
# family (the range combo) additionally carry for the whole
# appliance. Read-only: no live device to confirm remotely turning
# a cooktop on wouldn't leave a burner active unattended.
BinarySensorDesc(key='cooktop_power', field='power',
device_class='power', icon='mdi:pot-steam',
value_fn=lambda v: str(v).lower() == 'on'),
# Safe to write -- a lock toggle, not a heat control -- via a
# direct single-field PUT (no RMW needed; unlike burnerList this
# is a lone scalar, not an array of siblings to preserve).
SwitchDesc(key='cooktop_child_lock', field='childLock',
device_class='lock', entity_category='config',
icon='mdi:lock',
value_fn=lambda v: str(v).lower() == 'on',
write_fn=_child_lock_write),
*[e for i in range(MAX_BURNERS) for e in _burner_entities(i)],
),
)
@@ -133,3 +167,46 @@ COOKTOP_SAFETY = Capability(
value_fn=lambda v: (v or {}).get('state') == 'on'),
),
)
# Bluetooth meat probe (issue #86). All-idle sentinel values when
# disconnected (operationBurnerNumber -1, temperatures 0) -- no special
# gating on those, matching cooktop.PAIRED_HOOD_STATUS's own precedent of
# showing a disconnected accessory's fields plainly rather than hiding the
# whole capability.
PROBE_STATUS = Capability(
href='/bluetooth/probe/status/vs/0',
poll_tier='warm',
entities=(
BinarySensorDesc(key='probe_connected', field='connectionState',
device_class='connectivity',
value_fn=lambda v: str(v).lower() == 'connected'),
SensorDesc(key='probe_battery', field='batteryPercentage',
device_class='battery', state_class='measurement',
unit='%', entity_category='diagnostic'),
SensorDesc(key='probe_temperature', field='currentTemperature',
device_class='temperature', state_class='measurement',
unit_fn=lambda rep: normalize_temp_unit(rep.get('temperatureUnit'), '°C')),
SensorDesc(key='probe_target_temperature', field='targetTemperature',
device_class='temperature', entity_category='diagnostic',
unit_fn=lambda rep: normalize_temp_unit(rep.get('temperatureUnit'), '°C')),
),
)
# Some range boards (issue #74's NE63B8411SS) report no /cooktop/status/vs/0
# burner array at all -- their local API only exposes this coarse
# monitoring resource for the cooktop half, with no per-burner detail.
# Meaning of `cooktopMonitoring` (a bare "0" on the only dump seen) and
# `warmingCenterState`'s full value set aren't confirmed, so both are
# exposed as plain sensors rather than guessed at as a switch/select --
# `supportedHoodLampStateList` has no corresponding live-state field on
# this resource, so nothing to bind it to yet.
COOKTOP_MONITORING = Capability(
href='/cooktopmonitoring/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='cooktop_running_state', field='x.com.samsung.da.cooktopRunningState',
icon='mdi:pot-steam-outline'),
SensorDesc(key='warming_center_state', field='x.com.samsung.da.warmingCenterState',
icon='mdi:heat-wave', entity_category='diagnostic'),
),
)
@@ -9,9 +9,11 @@ independent fields.
from datetime import datetime, timezone
from ..batch import is_stub_rep
from ..capability import Capability
from ..entities import (
BinarySensorDesc,
ButtonDesc,
FanDesc,
SelectDesc,
SensorDesc,
@@ -99,6 +101,11 @@ HOOD_FAN = Capability(
field='x.com.samsung.da.hood.autoOperation',
icon='mdi:fan-auto',
entity_category='diagnostic',
# Absent on the microwave family's built-in vent fan (issue
# #137) -- this board has no auto-ventilation mode, unlike the
# standalone range hood this capability was written for.
exists_fn=lambda rep, resources: (
is_stub_rep(rep) or 'x.com.samsung.da.hood.autoOperation' in rep),
value_fn=lambda value: str(value).lower() == 'on',
),
),
@@ -179,6 +186,50 @@ HOOD_FILTER = Capability(
)
# After Run (issue #147): the hood keeps the fan running at low speed for a
# while after it's switched off, to clear residual cooking smoke -- a
# feature a user actively watches and cancels, not passive diagnostics, so
# none of the three entities below carry entity_category. No
# supported-values list is advertised for activationState, so it's modeled
# read-only (monitoring, not an invented "enable" write) per the 'don't
# guess' rule; runningCancel's only observed value is the command name
# itself ('Cancel'), the same self-describing command-field shape as
# operational.STOP_BUTTON. runningProgress's own name states its domain
# (a percentage of the cycle completed), so it's modeled as one rather than
# left an opaque passthrough -- unlike activationState/runningCancel, there's
# no ambiguous field name or missing-write-contract question here to hedge on.
AFTER_RUN = Capability(
href='/afterrun/vs/0',
poll_tier='warm',
entities=(
BinarySensorDesc(
key='after_run_active',
field='x.com.samsung.da.activationState',
icon='mdi:fan-clock',
value_fn=lambda value: str(value).lower() == 'on',
),
SensorDesc(
key='after_run_progress',
field='x.com.samsung.da.runningProgress',
unit='%',
state_class='measurement',
icon='mdi:fan-clock',
value_fn=int_or_none,
),
ButtonDesc(
key='after_run_cancel',
field='',
payload='Cancel',
icon='mdi:fan-off',
write_fn=lambda p, rep, href=None: (
['afterrun', 'vs', '0'],
{'x.com.samsung.da.runningCancel': p},
),
),
),
)
AIR_QUALITY = Capability(
href='/sensors/vs/0',
poll_tier='warm',
@@ -0,0 +1,109 @@
"""Capabilities for the Samsung stick-vacuum clean/auto-empty station
(model A-VSKR-TP1-22-VS9500AL, "Bespoke Jet" clean station, issue #131).
The reporter's diagnostics dump shows no vacuum-body state at all (no
suction level, no battery, no cleaning-mode/room-mapping control, no
docked/undocked status even) -- only the clean station's own dustbag,
dustbin auto-empty settings, and UV-C sanitizing-cycle status. This
strongly suggests the WiFi/DTLS module lives in the station, not the
handheld stick: the station is the only "device" this integration's local
API can see, and the wand's own controls are unrelated hardware not
reachable this way. Modeled as its own device type -- these hrefs don't
overlap with any existing family, so there's no shared-href ambiguity to
resolve against another type (see registry/by_type/__init__.py's
docstring for that rule).
Resources verified against the issue #131 diagnostics dump.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, SelectDesc, SensorDesc, SwitchDesc
from .common import int_or_none, parse_iso_utc as _parse_iso_utc
DUSTBAG = Capability(
href='/component/station/dustbag/vs/0',
poll_tier='warm',
entities=(
BinarySensorDesc(key='dustbag_full', field='x.com.samsung.da.status',
device_class='problem',
icon='mdi:bag-personal',
value_fn=lambda v: v == 'full'),
),
)
# dustbagUsage/dustbagPrevUsage are raw counters with no capacity/resolution
# field alongside them to normalize into a percentage (unlike the AC/range
# families' filterUsage, which always ships filterCapacity) -- exposed as a
# plain diagnostic count rather than guessing a unit.
DUSTBAG_USAGE = Capability(
href='/component/station/dustbagusage/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='dustbag_usage', field='x.com.samsung.da.dustbagUsage',
icon='mdi:counter', entity_category='diagnostic',
state_class='total_increasing', value_fn=int_or_none),
),
)
DUSTBIN_SETTING = Capability(
href='/setting/dustbin/vs/0',
poll_tier='warm',
entities=(
SwitchDesc(key='auto_empty', field='x.com.samsung.da.autoEmpty',
icon='mdi:delete-empty',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['setting', 'dustbin', 'vs', '0'],
{'x.com.samsung.da.autoEmpty': 'On' if p == 'On' else 'Off'})),
SwitchDesc(key='dustbin_auto_close', field='x.com.samsung.da.autoClose',
icon='mdi:door-sliding',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['setting', 'dustbin', 'vs', '0'],
{'x.com.samsung.da.autoClose': 'On' if p == 'On' else 'Off'})),
SelectDesc(key='discharging_time', field='x.com.samsung.da.desiredDischargingTime',
icon='mdi:timer-outline',
entity_category='config',
options_field='x.com.samsung.da.supportedDischargingTime',
write_fn=lambda p, rep, href=None: (
['setting', 'dustbin', 'vs', '0'],
{'x.com.samsung.da.desiredDischargingTime': p})),
),
)
# stickStatus's exact meaning (docked? powered? charging?) isn't confirmed
# from this single On/Off dump -- exposed as a plain diagnostic sensor
# rather than a binary_sensor, so no polarity/semantic is asserted that
# might be wrong.
CLEANSTATION_STATUS = Capability(
href='/status/cleanstation/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='cleanstation_status', field='x.com.samsung.da.status',
icon='mdi:home-lightning-bolt', entity_category='diagnostic'),
SensorDesc(key='stick_status', field='x.com.samsung.da.stickStatus',
icon='mdi:broom', entity_category='diagnostic'),
SwitchDesc(key='uvc_intensive_mode', field='x.com.samsung.da.uvcIntensive',
icon='mdi:lightbulb-on-outline',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['status', 'cleanstation', 'vs', '0'],
{'x.com.samsung.da.uvcIntensive': 'On' if p == 'On' else 'Off'})),
SensorDesc(key='uvc_operation_time', field='x.com.samsung.da.uvcOperationTime',
icon='mdi:timer-sand', entity_category='diagnostic',
value_fn=int_or_none),
SensorDesc(key='uvc_total_operation_time',
field='x.com.samsung.da.uvcTotalOperationTime',
icon='mdi:timer-sand', entity_category='diagnostic',
state_class='total_increasing', value_fn=int_or_none),
SensorDesc(key='uvc_finished_time', field='x.com.samsung.da.uvcFinishedTime',
device_class='timestamp', entity_category='diagnostic',
value_fn=_parse_iso_utc),
SensorDesc(key='uvc_emitted_time', field='x.com.samsung.da.emittedTime',
device_class='timestamp', entity_category='diagnostic',
value_fn=_parse_iso_utc),
),
)
@@ -45,6 +45,14 @@ from .laundry import (
# (issue #22). Combo units carry their own course set, so these codes
# don't imply anything about '1F' on a plain washer.
#
# Three more -- '52' Eco Cold, '54' Towels, '60' Self Clean+ -- came from a
# WF50A8600AV/US, verified directly rather than by inference: the reporter
# selected each cycle on the physical appliance and read back the resulting
# raw code from the cycle_select entity's state (issue #80). '54' shares a
# display name with the existing '24' Towels -- a different code on a
# different course table legitimately landing on the same label, not a typo
# (same pattern as '21'/'65' Colors and '27'/'5E' Rinse+Spin above).
#
# No static fallback list of those codes is kept here, deliberately: other
# washer models have a different actual course set (a second dump's active
# course, '65', isn't even in the list above; models with 'AI Wash'/'Mixed
@@ -0,0 +1,256 @@
"""Capabilities for the Samsung water-purifier family (TP2X_WATERPURIFIER-class,
issue #90, model TP2X_WATERPURIFIER_20K).
Resources verified against the issue #90 diagnostics dump.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc
from .common import int_or_none, parse_iso_utc as _parse_iso_utc
DISPENSE = Capability(
href='/setting/waterpurifier/vs/0',
poll_tier='warm',
entities=(
SelectDesc(key='dispense_type', field='x.com.samsung.da.desiredType',
icon='mdi:cup-water',
options_field='x.com.samsung.da.supportedTypes',
write_fn=lambda p, rep, href=None: (
['setting', 'waterpurifier', 'vs', '0'],
{'x.com.samsung.da.desiredType': p})),
# Only a handful of discrete temperatures are selectable (not a
# continuous range) -- a select over the live-reported set, not a
# number with invented bounds.
SelectDesc(key='hot_water_temperature', field='x.com.samsung.da.tempDesiredHotWater',
icon='mdi:thermometer',
entity_category='config',
options_field='x.com.samsung.da.supportedHotTemperatures',
write_fn=lambda p, rep, href=None: (
['setting', 'waterpurifier', 'vs', '0'],
{'x.com.samsung.da.tempDesiredHotWater': p})),
# Bounds and step come live from the device's own
# desiredCapacityRange/capacityResolution fields, not a hardcoded
# constant -- see the adding-device-support skill's "never hard-code
# the one dump's values" section. No unit is set: capacityUnit reads
# "C" on this dump, which can't be right for a volume field, so per
# the 'don't guess' rule the unit is left unset rather than assumed
# to be mL.
NumberDesc(key='dispense_capacity', field='x.com.samsung.da.desiredCapacity',
icon='mdi:cup-water',
value_fn=int_or_none,
range_field='x.com.samsung.da.desiredCapacityRange',
step_fn=lambda rep: int_or_none(
rep.get('x.com.samsung.da.capacityResolution')) or 1,
write_fn=lambda p, rep, href=None: (
['setting', 'waterpurifier', 'vs', '0'],
{'x.com.samsung.da.desiredCapacity': str(int(round(float(p))))})),
BinarySensorDesc(key='pouring', field='x.com.samsung.da.pourStatus',
icon='mdi:cup-water',
value_fn=lambda v: v == 'On'),
),
)
STATUS = Capability(
href='/status/waterpurifier/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='waterpurifier_status', field='x.com.samsung.da.status',
icon='mdi:water-pump',
entity_category='diagnostic'),
BinarySensorDesc(key='filter_door_status', field='x.com.samsung.da.filterDoorStatus',
device_class='door',
entity_category='diagnostic',
value_fn=lambda v: v == 'Open'),
SensorDesc(key='sterilize_period', field='x.com.samsung.da.sterilizePeriod',
icon='mdi:calendar-sync',
entity_category='diagnostic'),
SensorDesc(key='sterilize_run_time', field='x.com.samsung.da.sterilizeRunTime',
icon='mdi:timer-outline',
entity_category='diagnostic'),
SensorDesc(key='sterilize_last_time', device_class='timestamp',
entity_category='diagnostic',
rep_fn=lambda rep: _parse_iso_utc(
rep.get('x.com.samsung.da.sterilizeLastTime'))),
SensorDesc(key='sterilize_plan_time', device_class='timestamp',
entity_category='diagnostic',
rep_fn=lambda rep: _parse_iso_utc(
rep.get('x.com.samsung.da.sterilizePlanTime'))),
SensorDesc(key='filter_clean_remain_time', field='x.com.samsung.da.filterCleanRemainTime',
icon='mdi:timer-sand',
entity_category='diagnostic'),
),
)
FAVORITE_CAPACITY = Capability(
href='/favorite/capacity/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='favorite_capacity_enabled', field='x.com.samsung.da.switchCapacity',
icon='mdi:star-outline',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['favorite', 'capacity', 'vs', '0'],
{'x.com.samsung.da.switchCapacity': 'On' if p == 'On' else 'Off'})),
SelectDesc(key='favorite_capacity', field='x.com.samsung.da.defaultCapacity',
icon='mdi:cup-water',
entity_category='config',
options_field='x.com.samsung.da.capacityList',
write_fn=lambda p, rep, href=None: (
['favorite', 'capacity', 'vs', '0'],
{'x.com.samsung.da.defaultCapacity': p})),
),
)
# Coffee-capable variant (issue #107) -- a "favorite" supported-list select
# for the hot water dispensed alongside brewing, same shape as
# FAVORITE_CAPACITY above.
def _status_lock_definitely_lacks_hotwater_field(resources: dict) -> bool:
"""Three-way read of /status/lock/vs/0's hotwaterLock field, favouring
LOCK.hotwater_lock (the primary descriptor) whenever the outcome is
still ambiguous:
- href entirely absent from this device -> definitely no clash, the
switchHotwater fallback below may claim the entity.
- href present but an unfetched stub ({}) -> outcome pending, *not* a
confirmed absence. LOCK's own exists_fn optimistically includes itself
through a stub (matching entity.py's default), so returning True here
too would register both descriptors -- as SwitchDescs sharing one key,
with identical unique_ids -- until the next poll resolves it.
- href present and fetched -> the real answer."""
rep = resources.get('/status/lock/vs/0')
if rep is None:
return True
if not rep:
return False
return 'x.com.samsung.da.hotwaterLock' not in rep
FAVORITE_HOTWATER = Capability(
href='/favorite/hotwater/vs/0',
poll_tier='cold',
entities=(
# Despite the resource/field naming, switchHotwater's value domain is
# Locked/Unlocked, not an enable flag (issue #144) -- it's the same
# hot-water lock as LOCK.hotwater_lock below, just surfaced through
# this href on boards that don't populate /status/lock/vs/0's
# hotwaterLock field. Shares that descriptor's key so only one "Hot
# water lock" entity ever appears.
#
# Both halves of this fallback pair need an exists_fn, not just this
# one: adapter.flatten() (the coordinator.data source every entity's
# is_on reads) only ever honours exists_fn, never entity.py's
# implicit "require own field present" default that gates plain
# registration. Two same-keyed descriptors with only one of them
# gated still both land in flatten()'s output dict -- whichever is
# processed last silently wins, decided by device-reported href
# order, not by which one is actually correct. So this exists_fn
# also re-asserts its own field's presence (switchHotwater), the
# gate a bare `field=` used to get for free before it had to share a
# key with LOCK's descriptor.
SwitchDesc(key='hotwater_lock', field='x.com.samsung.da.switchHotwater',
device_class='lock',
entity_category='config',
value_fn=lambda v: v != 'Unlocked',
exists_fn=lambda rep, resources: (
'x.com.samsung.da.switchHotwater' in rep
and _status_lock_definitely_lacks_hotwater_field(resources)),
write_fn=lambda p, rep, href=None: (
['favorite', 'hotwater', 'vs', '0'],
{'x.com.samsung.da.switchHotwater': 'Locked' if p == 'On' else 'Unlocked'})),
SelectDesc(key='favorite_hotwater_temperature',
field='x.com.samsung.da.favorite.defaultTemperature',
icon='mdi:thermometer',
entity_category='config',
options_field='x.com.samsung.da.favorite.supportedList',
write_fn=lambda p, rep, href=None: (
['favorite', 'hotwater', 'vs', '0'],
{'x.com.samsung.da.favorite.defaultTemperature': p})),
),
)
# Coffee-capable variant (issue #107). No 'x.com.samsung.da.' field prefix
# on this resource, unlike the rest of the water-purifier surface.
COFFEE = Capability(
href='/favorite/coffee/vs/0',
poll_tier='warm',
entities=(
SwitchDesc(key='favorite_coffee_enabled', field='favorite.activate',
icon='mdi:coffee-outline',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['favorite', 'coffee', 'vs', '0'],
{'favorite.activate': 'On' if p == 'On' else 'Off'})),
SensorDesc(key='coffee_brew_status', field='brew.status',
icon='mdi:coffee-outline',
entity_category='diagnostic'),
),
)
LOCK = Capability(
href='/status/lock/vs/0',
poll_tier='warm',
entities=(
# Shares its key with FAVORITE_HOTWATER's switchHotwater fallback
# above (issue #144); see the comment there for why this half also
# needs an explicit exists_fn now that the two share a key in
# adapter.flatten()'s output. A stub rep ({}) still counts as
# "present" here (matches entity.py's own default for a field-less
# gate) since the alternative -- treating an unfetched resource as
# confirmed-absent -- is what let both descriptors register at once.
SwitchDesc(key='hotwater_lock', field='x.com.samsung.da.hotwaterLock',
device_class='lock',
entity_category='config',
value_fn=lambda v: v != 'Unlocked',
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.hotwaterLock' in rep),
write_fn=lambda p, rep, href=None: (
['status', 'lock', 'vs', '0'],
{'x.com.samsung.da.hotwaterLock': 'Locked' if p == 'On' else 'Unlocked'})),
SwitchDesc(key='coldwater_lock', field='x.com.samsung.da.coldwaterLock',
device_class='lock',
entity_category='config',
value_fn=lambda v: v != 'Unlocked',
write_fn=lambda p, rep, href=None: (
['status', 'lock', 'vs', '0'],
{'x.com.samsung.da.coldwaterLock': 'Locked' if p == 'On' else 'Unlocked'})),
SwitchDesc(key='buzz_lock', field='x.com.samsung.da.buzzLock',
device_class='lock',
entity_category='config',
value_fn=lambda v: v != 'Unlocked',
write_fn=lambda p, rep, href=None: (
['status', 'lock', 'vs', '0'],
{'x.com.samsung.da.buzzLock': 'Locked' if p == 'On' else 'Unlocked'})),
),
)
# ---------------------------------------------------------------------------
# Water-purifier-scoped coverage: hrefs with no user-actionable state or no
# confirmed contract, following the 'don't guess' rule.
# ---------------------------------------------------------------------------
_WP_IGNORED = [
# supportedModes carries a single opaque wizard-workflow token
# ('HOMECARE_WIZARD_V2') and modes reports a completely different,
# unrelated value ('WATERFILTER_DISABLE') not even present in
# supportedModes -- internal plumbing, not a real user-facing mode
# select. OCF-standard /mode/0 mirrors the same vendor resource but is
# already covered by the global ignored.IGNORED (fridge's OCF-native
# vacation-mode flag shares that href).
'/mode/vs/0',
# Static support-flags blob (automation.supported.modes/options) -- no
# live "current automation setting" field to expose.
'/automation/waterpurifier/vs/0',
# Coffee-capable variant (issue #107). All four are static
# capability-advertisement blobs or empty -- no live "current recipe" /
# "current custom slot" field to expose, unlike /favorite/coffee/vs/0
# (COFFEE above), which does carry live brew status.
'/brand/recipe/info/vs/0', # revision + max-brand-count metadata
'/coffee/custom/recipe/vs/0', # publisher.support: allowed custom-recipe slot IDs
'/recipe/coffee/vs/0', # same publisher.support shape, no per-recipe content
'/recipe/coffee/deletion/vs/0', # empty {} on this dump
]
COVERAGE = [Capability(href=h) for h in _WP_IGNORED]
@@ -1,6 +1,9 @@
{
"entity": {
"binary_sensor": {
"after_run_active": {
"name": "After run active"
},
"any_burner_active": {
"name": "Any burner active"
},
@@ -10,15 +13,27 @@
"burner_hot_surface": {
"name": "Burner {number} hot surface"
},
"burner_pan_detected": {
"name": "Burner {number} pan detected"
},
"cloud_connected": {
"name": "Cloud connected"
},
"dustbag_full": {
"name": "Dust bag full"
},
"cooktop_power": {
"name": "Cooktop power"
},
"cooktop_safety_shutoff_enabled": {
"name": "Hot surface auto-shutoff enabled"
},
"current_limit_enabled": {
"name": "Current limit enabled"
},
"overload_protection_active": {
"name": "Overload protection active"
},
"cycle_active": {
"name": "Running"
},
@@ -34,6 +49,9 @@
"door_open": {
"name": "Door"
},
"filter_door_status": {
"name": "Filter door"
},
"firmware_update": {
"name": "Firmware update available"
},
@@ -52,9 +70,18 @@
"periodic_air_sensing": {
"name": "Periodic air sensing"
},
"pouring": {
"name": "Pouring"
},
"power_state": {
"name": "Power state"
},
"probe_connected": {
"name": "Probe connected"
},
"power_switch": {
"name": "Power"
},
"rapid_freezing": {
"name": "Rapid freezing"
},
@@ -69,6 +96,9 @@
}
},
"button": {
"after_run_cancel": {
"name": "Cancel after run"
},
"diagnosis_start": {
"name": "Start diagnosis"
},
@@ -95,9 +125,31 @@
},
"preset_mode": {
"state": {
"ai_comfort": "AI Comfort",
"quiet": "Quiet",
"smart": "Smart",
"speed": "Speed"
"speed": "Speed",
"nano": "WindFree",
"nanosleep": "WindFree sleep",
"longwind": "Long wind",
"motionindirect": "Motion indirect",
"motiondirect": "Motion direct",
"drycomfort": "Dry comfort"
}
}
}
}
},
"fan": {
"air_purifier_fan": {
"state_attributes": {
"preset_mode": {
"state": {
"smart": "Smart",
"max": "Max",
"mid": "Mid",
"windfree": "WindFree",
"sleep": "Sleep"
}
}
}
@@ -110,14 +162,23 @@
"delay_start_hours": {
"name": "Delay start"
},
"dispense_capacity": {
"name": "Dispense capacity"
},
"instance_setpoint": {
"name": "{instance_name} setpoint"
},
"oven_setpoint": {
"name": "Setpoint"
},
"setpoint": {
"name": "Setpoint"
},
"sound_volume": {
"name": "Sound volume"
},
"target_humidity": {
"name": "Target humidity"
}
},
"select": {
@@ -154,6 +215,13 @@
"on": "On"
}
},
"discharging_time": {
"name": "Discharging time",
"state": {
"1": "1 minute",
"3": "3 minutes"
}
},
"cycle": {
"name": "Cycle"
},
@@ -189,6 +257,9 @@
"8f": "Baby Care"
}
},
"dispense_type": {
"name": "Dispense type"
},
"door_alert": {
"name": "Door alarm",
"state": {
@@ -201,6 +272,8 @@
"dryer_cycle_table_03": {
"name": "Cycle",
"state": {
"01": "Normal",
"06": "Time dry",
"16": "Cotton",
"18": "Synthetics",
"19": "Delicates",
@@ -217,6 +290,12 @@
"1f": "Mixed load"
}
},
"favorite_capacity": {
"name": "Favorite capacity"
},
"favorite_hotwater_temperature": {
"name": "Favorite hot water temperature"
},
"finish_sound": {
"name": "Finish sound",
"state": {
@@ -248,6 +327,9 @@
"extra_high": "Extra high"
}
},
"hot_water_temperature": {
"name": "Hot water temperature"
},
"ice_type": {
"name": "{instance_name} type",
"state": {
@@ -271,6 +353,22 @@
"high": "High"
}
},
"cooking_mode": {
"name": "Cooking mode",
"state": {
"no_operation": "No operation",
"micro_wave": "Microwave",
"micro_wave_grill": "Microwave + grill",
"micro_wave_convection": "Microwave + convection",
"convection": "Convection",
"air_fryer": "Air fry",
"grill": "Grill",
"autocook": "Auto cook",
"autocook_custom": "Auto cook (custom)",
"deodorization": "Deodorize",
"keep_warm": "Keep warm"
}
},
"oven_mode": {
"name": "Cooking mode",
"state": {
@@ -286,6 +384,40 @@
"air_fry": "Air fry"
}
},
"operating_mode": {
"name": "Operating mode"
},
"kimchi_zone_mode": {
"name": "{instance_name} storage mode",
"state": {
"off": "Off",
"kimchi_storage_normal": "Kimchi",
"kimchi_storage_cold": "Kimchi, strong",
"kimchi_storage_warm": "Kimchi, weak",
"kimchi_storage_low_salt_normal": "Low-salt kimchi",
"kimchi_storage_low_salt_cold": "Low-salt kimchi, strong",
"kimchi_storage_low_salt_warm": "Low-salt kimchi, weak",
"kimchi_storage_crunfch": "Crisp kimchi",
"kimchi_storage_buy": "Purchased kimchi",
"storage_fridge_normal": "Fridge",
"storage_fridge_cold": "Fridge, strong",
"storage_fridge_warm": "Fridge, weak",
"storage_freezer_normal": "Freezer",
"storage_freezer_cold": "Freezer, strong",
"storage_freezer_warm": "Freezer, weak",
"kimchi_ripe_low_temp": "Kimchi ripening, low temperature",
"kimchi_ripe_normal_temp": "Kimchi ripening, room temperature",
"kimchi_ripe_kkakdugi": "Kkakdugi ripening",
"kimchi_ripe_dongchimi": "Dongchimi ripening",
"meat_ripe_normal": "Meat ripening",
"storage_meat": "Meat & fish",
"storage_fridge_vegetables_fruit": "Fruit & vegetables",
"storage_fresh_cereal": "Grains",
"storage_fridge_drink": "Beverages",
"storage_fresh_wine": "Wine",
"storage_fresh_potato_banana": "Potato & banana"
}
},
"pantry_zone_mode": {
"name": "Pantry zone mode",
"state": {
@@ -337,6 +469,13 @@
"mute": "Mute"
}
},
"air_purifier_sound_mode": {
"name": "Sound mode",
"state": {
"mute": "Mute",
"buzzer": "Buzzer"
}
},
"spin_speed": {
"name": "Spin speed",
"state": {
@@ -379,30 +518,37 @@
"27": "Rinse+Spin",
"28": "Drain/Spin",
"29": "Drum Clean+",
"2a": "Jeans",
"2b": "AI Wash",
"2d": "Silent Wash",
"2e": "Baby Care",
"2f": "Activewear",
"30": "Cloudy Day",
"32": "Shirts",
"33": "Bedding",
"34": "Mixed",
"36": "Wash+Dry",
"37": "Air Wash",
"38": "Cotton Dry",
"39": "Synthetics Dry",
"3a": "Drum Clean",
"52": "Eco Cold",
"53": "Heavy Duty",
"54": "Towels",
"55": "Activewear",
"57": "Delicate",
"5e": "Rinse+Spin",
"60": "Self Clean+",
"65": "Colors",
"66": "Denim",
"7c": "Whites",
"7d": "Bedding/Waterproof",
"7e": "Self-Clean",
"7f": "Wool/Delicate",
"86": "Deep Wash",
"87": "Download",
"8f": "Intense Cold",
"96": "Less Microfiber",
"2b": "AI Wash",
"2a": "Jeans"
"96": "Less Microfiber"
}
},
"washer_dry_level": {
@@ -420,6 +566,9 @@
}
},
"sensor": {
"after_run_progress": {
"name": "After run progress"
},
"air_filter_usage": {
"name": "Filter usage"
},
@@ -441,6 +590,9 @@
"clean_level": {
"name": "Clean level"
},
"coffee_brew_status": {
"name": "Coffee brew status"
},
"connection_mode": {
"name": "Connection mode",
"state": {
@@ -448,15 +600,58 @@
"poll": "Polling"
}
},
"cooktop_running_state": {
"name": "Cooktop running state"
},
"cooktop_state": {
"name": "Cooktop state"
},
"current_limit_level": {
"name": "Current limit level"
},
"hepa_filter_usage": {
"name": "HEPA filter usage"
},
"panel_status": {
"name": "Panel status"
},
"sound_output": {
"name": "Sound output"
},
"dustbag_usage": {
"name": "Dust bag usage"
},
"cleanstation_status": {
"name": "Clean station status"
},
"stick_status": {
"name": "Stick status"
},
"uvc_operation_time": {
"name": "UV-C operation time"
},
"uvc_total_operation_time": {
"name": "UV-C total operation time"
},
"uvc_finished_time": {
"name": "UV-C finished time"
},
"uvc_emitted_time": {
"name": "UV-C emitted time"
},
"overload_protection_mode": {
"name": "Overload protection mode",
"state": {
"alarm": "Alarm",
"powersaving": "Power saving"
}
},
"current_temp_c": {
"name": "Temperature"
},
"current_temperature_c": {
"name": "Temperature"
},
"diagnosis": {
"name": "Diagnosis"
},
@@ -499,6 +694,9 @@
"fan_speed_level": {
"name": "Fan speed level"
},
"filter_clean_remain_time": {
"name": "Filter clean remaining time"
},
"filter_progress": {
"name": "Filter progress"
},
@@ -520,12 +718,27 @@
"fridge_temperature": {
"name": "Fridge temperature"
},
"kimchi_ripening_status": {
"name": "{instance_name} ripening status"
},
"kimchi_ripening_remaining": {
"name": "{instance_name} ripening time remaining"
},
"kimchi_rack_count": {
"name": "{instance_name} rack count"
},
"hood_filter_capacity": {
"name": "Filter capacity"
},
"humidity": {
"name": "Humidity"
},
"hood_filter_usage": {
"name": "Filter usage"
},
"humidity": {
"name": "Humidity"
},
"instance_temperature": {
"name": "{instance_name} temperature"
},
@@ -559,6 +772,12 @@
"oven_state": {
"name": "Cavity state"
},
"cavity_state": {
"name": "Cavity state"
},
"power_level": {
"name": "Power level"
},
"paired_hood_fan_speed": {
"name": "Paired hood fan speed"
},
@@ -574,6 +793,15 @@
"power_watts": {
"name": "Power"
},
"probe_battery": {
"name": "Probe battery"
},
"probe_target_temperature": {
"name": "Probe target temperature"
},
"probe_temperature": {
"name": "Probe temperature"
},
"progress": {
"name": "Progress"
},
@@ -589,12 +817,30 @@
"selfcheck_status": {
"name": "Self-check status"
},
"sterilize_last_time": {
"name": "Sterilize last time"
},
"sterilize_period": {
"name": "Sterilize period"
},
"sterilize_plan_time": {
"name": "Sterilize plan time"
},
"sterilize_run_time": {
"name": "Sterilize run time"
},
"super_fine_dust": {
"name": "Super fine dust"
},
"warming_center_state": {
"name": "Warming center state"
},
"water_liters": {
"name": "Water consumption"
},
"waterpurifier_status": {
"name": "Status"
},
"machine_state": {
"name": "Machine state",
"state": {
@@ -629,6 +875,21 @@
"auto_clean": {
"name": "Auto clean"
},
"display": {
"name": "Display"
},
"pet_filter_activation": {
"name": "Pet filter activation"
},
"auto_empty": {
"name": "Auto empty"
},
"dustbin_auto_close": {
"name": "Dustbin auto-close"
},
"uvc_intensive_mode": {
"name": "UV-C intensive mode"
},
"auto_door_opener": {
"name": "Auto door opener"
},
@@ -641,6 +902,9 @@
"bubble_soak": {
"name": "Bubble soak"
},
"buzz_lock": {
"name": "Buzzer lock"
},
"cabinet_light_dim": {
"name": "Brighten gradually"
},
@@ -650,6 +914,12 @@
"child_lock": {
"name": "Child lock"
},
"coldwater_lock": {
"name": "Cold water lock"
},
"cooktop_child_lock": {
"name": "Child lock"
},
"defrost_delay": {
"name": "Defrost delay"
},
@@ -659,9 +929,18 @@
"fast_preheat": {
"name": "Fast preheat"
},
"favorite_capacity_enabled": {
"name": "Favorite capacity"
},
"favorite_coffee_enabled": {
"name": "Favorite coffee"
},
"fridge_sound": {
"name": "Sound"
},
"hotwater_lock": {
"name": "Hot water lock"
},
"ice_maker_enabled": {
"name": "Ice maker"
},
@@ -1,6 +1,9 @@
{
"entity": {
"binary_sensor": {
"after_run_active": {
"name": "Nadraaien actief"
},
"any_burner_active": {
"name": "Een brander actief"
},
@@ -10,15 +13,27 @@
"burner_hot_surface": {
"name": "Brander {number} heet oppervlak"
},
"burner_pan_detected": {
"name": "Brander {number} pan gedetecteerd"
},
"cloud_connected": {
"name": "Verbonden met cloud"
},
"dustbag_full": {
"name": "Stofzak vol"
},
"cooktop_power": {
"name": "Kookplaat voeding"
},
"cooktop_safety_shutoff_enabled": {
"name": "Automatische uitschakeling heet oppervlak ingeschakeld"
},
"current_limit_enabled": {
"name": "Stroombegrenzing ingeschakeld"
},
"overload_protection_active": {
"name": "Overbelastingsbeveiliging actief"
},
"cycle_active": {
"name": "Actief"
},
@@ -34,6 +49,9 @@
"door_open": {
"name": "Deur"
},
"filter_door_status": {
"name": "Filterdeur"
},
"firmware_update": {
"name": "Firmware-update beschikbaar"
},
@@ -52,9 +70,18 @@
"periodic_air_sensing": {
"name": "Periodieke luchtmeting"
},
"pouring": {
"name": "Schenken"
},
"power_state": {
"name": "Voedingsstatus"
},
"probe_connected": {
"name": "Sonde verbonden"
},
"power_switch": {
"name": "Voeding"
},
"rapid_freezing": {
"name": "Snelvriezen"
},
@@ -69,6 +96,9 @@
}
},
"button": {
"after_run_cancel": {
"name": "Nadraaien annuleren"
},
"diagnosis_start": {
"name": "Diagnose starten"
},
@@ -95,9 +125,31 @@
},
"preset_mode": {
"state": {
"ai_comfort": "AI-comfort",
"quiet": "Stil",
"smart": "Slim",
"speed": "Snel"
"speed": "Snel",
"nano": "WindFree",
"nanosleep": "WindFree-slaap",
"longwind": "Lange wind",
"motionindirect": "Beweging indirect",
"motiondirect": "Beweging direct",
"drycomfort": "Droog comfort"
}
}
}
}
},
"fan": {
"air_purifier_fan": {
"state_attributes": {
"preset_mode": {
"state": {
"smart": "Slim",
"max": "Max",
"mid": "Gemiddeld",
"windfree": "WindFree",
"sleep": "Slaap"
}
}
}
@@ -110,14 +162,23 @@
"delay_start_hours": {
"name": "Uitgestelde start"
},
"dispense_capacity": {
"name": "Schenkhoeveelheid"
},
"instance_setpoint": {
"name": "Instelpunt {instance_name}"
},
"oven_setpoint": {
"name": "Instelpunt"
},
"setpoint": {
"name": "Instelpunt"
},
"sound_volume": {
"name": "Geluidsvolume"
},
"target_humidity": {
"name": "Doelvochtigheid"
}
},
"select": {
@@ -154,6 +215,13 @@
"on": "Aan"
}
},
"discharging_time": {
"name": "Leegtijd",
"state": {
"1": "1 minuut",
"3": "3 minuten"
}
},
"cycle": {
"name": "Programma"
},
@@ -189,6 +257,9 @@
"8f": "Babyverzorging"
}
},
"dispense_type": {
"name": "Type dispenser"
},
"door_alert": {
"name": "Deuralarm",
"state": {
@@ -201,6 +272,8 @@
"dryer_cycle_table_03": {
"name": "Programma",
"state": {
"01": "Normaal",
"06": "Tijdprogramma",
"16": "Katoen",
"18": "Synthetisch",
"19": "Fijne was",
@@ -217,6 +290,12 @@
"1f": "Gemengde was"
}
},
"favorite_capacity": {
"name": "Favoriete capaciteit"
},
"favorite_hotwater_temperature": {
"name": "Favoriete temperatuur warm water"
},
"finish_sound": {
"name": "Eindgeluid",
"state": {
@@ -248,6 +327,9 @@
"extra_high": "Extra hoog"
}
},
"hot_water_temperature": {
"name": "Temperatuur warm water"
},
"ice_type": {
"name": "Type {instance_name}",
"state": {
@@ -271,6 +353,22 @@
"high": "Hoog"
}
},
"cooking_mode": {
"name": "Bereidingsmodus",
"state": {
"no_operation": "Niet actief",
"micro_wave": "Magnetron",
"micro_wave_grill": "Magnetron + grill",
"micro_wave_convection": "Magnetron + hetelucht",
"convection": "Hetelucht",
"air_fryer": "Airfryen",
"grill": "Grillen",
"autocook": "Automatisch koken",
"autocook_custom": "Automatisch koken (aangepast)",
"deodorization": "Geurverwijdering",
"keep_warm": "Warmhouden"
}
},
"oven_mode": {
"name": "Bereidingsmodus",
"state": {
@@ -286,6 +384,40 @@
"air_fry": "Airfryen"
}
},
"operating_mode": {
"name": "Bedrijfsmodus"
},
"kimchi_zone_mode": {
"name": "{instance_name} opslagmodus",
"state": {
"off": "Uit",
"kimchi_storage_normal": "Kimchi",
"kimchi_storage_cold": "Kimchi, sterk",
"kimchi_storage_warm": "Kimchi, zwak",
"kimchi_storage_low_salt_normal": "Kimchi met weinig zout",
"kimchi_storage_low_salt_cold": "Kimchi met weinig zout, sterk",
"kimchi_storage_low_salt_warm": "Kimchi met weinig zout, zwak",
"kimchi_storage_crunfch": "Knapperige kimchi",
"kimchi_storage_buy": "Gekochte kimchi",
"storage_fridge_normal": "Koelkast",
"storage_fridge_cold": "Koelkast, sterk",
"storage_fridge_warm": "Koelkast, zwak",
"storage_freezer_normal": "Vriezer",
"storage_freezer_cold": "Vriezer, sterk",
"storage_freezer_warm": "Vriezer, zwak",
"kimchi_ripe_low_temp": "Kimchi rijpen, lage temperatuur",
"kimchi_ripe_normal_temp": "Kimchi rijpen, kamertemperatuur",
"kimchi_ripe_kkakdugi": "Kkakdugi rijpen",
"kimchi_ripe_dongchimi": "Dongchimi rijpen",
"meat_ripe_normal": "Vlees rijpen",
"storage_meat": "Vlees en vis",
"storage_fridge_vegetables_fruit": "Groenten en fruit",
"storage_fresh_cereal": "Granen",
"storage_fridge_drink": "Dranken",
"storage_fresh_wine": "Wijn",
"storage_fresh_potato_banana": "Aardappelen en bananen"
}
},
"pantry_zone_mode": {
"name": "Modus voorraadzone",
"state": {
@@ -337,6 +469,13 @@
"mute": "Dempen"
}
},
"air_purifier_sound_mode": {
"name": "Geluidsmodus",
"state": {
"mute": "Dempen",
"buzzer": "Zoemer"
}
},
"spin_speed": {
"name": "Centrifugesnelheid",
"state": {
@@ -379,30 +518,37 @@
"27": "Spoelen+centrifugeren",
"28": "Afpompen/centrifugeren",
"29": "Drum Clean+",
"2a": "Spijkerbroek",
"2b": "AI Wash",
"2d": "Stille was",
"2e": "Babyverzorging",
"2f": "Sportkleding",
"30": "Bewolkte dag",
"32": "Overhemden",
"33": "Beddengoed",
"34": "Gemengd",
"36": "Wassen+drogen",
"37": "Air Wash",
"38": "Katoen drogen",
"39": "Synthetisch drogen",
"3a": "Trommel reinigen",
"52": "Eco koud",
"53": "Intensief",
"54": "Handdoeken",
"55": "Sportkleding",
"57": "Fijn",
"5e": "Spoelen+centrifugeren",
"60": "Zelfreinigend+",
"65": "Bonte was",
"66": "Spijkergoed",
"7c": "Witte was",
"7d": "Beddengoed/Waterdicht",
"7e": "Zelfreinigend",
"7f": "Wol/Fijn",
"86": "Diep wassen",
"87": "Downloaden",
"8f": "Intensief koud",
"96": "Minder microvezels",
"2b": "AI Wash",
"2a": "Spijkerbroek"
"96": "Minder microvezels"
}
},
"washer_dry_level": {
@@ -420,6 +566,9 @@
}
},
"sensor": {
"after_run_progress": {
"name": "Voortgang nadraaien"
},
"air_filter_usage": {
"name": "Filterverbruik"
},
@@ -441,6 +590,9 @@
"clean_level": {
"name": "Reinigingsniveau"
},
"coffee_brew_status": {
"name": "Koffiezetstatus"
},
"connection_mode": {
"name": "Verbindingsmodus",
"state": {
@@ -448,15 +600,58 @@
"poll": "Polling"
}
},
"cooktop_running_state": {
"name": "Loopstatus kookplaat"
},
"cooktop_state": {
"name": "Status kookplaat"
},
"current_limit_level": {
"name": "Niveau stroombegrenzing"
},
"hepa_filter_usage": {
"name": "HEPA-filtergebruik"
},
"panel_status": {
"name": "Paneelstatus"
},
"sound_output": {
"name": "Geluidsuitvoer"
},
"dustbag_usage": {
"name": "Stofzakgebruik"
},
"cleanstation_status": {
"name": "Status schoonmaakstation"
},
"stick_status": {
"name": "Status steel"
},
"uvc_operation_time": {
"name": "UV-C bedrijfstijd"
},
"uvc_total_operation_time": {
"name": "UV-C totale bedrijfstijd"
},
"uvc_finished_time": {
"name": "UV-C voltooid op"
},
"uvc_emitted_time": {
"name": "UV-C uitgestraald op"
},
"overload_protection_mode": {
"name": "Modus overbelastingsbeveiliging",
"state": {
"alarm": "Alarm",
"powersaving": "Energiebesparing"
}
},
"current_temp_c": {
"name": "Temperatuur"
},
"current_temperature_c": {
"name": "Temperatuur"
},
"diagnosis": {
"name": "Diagnose"
},
@@ -499,6 +694,9 @@
"fan_speed_level": {
"name": "Ventilatorniveau"
},
"filter_clean_remain_time": {
"name": "Resterende tijd filterreiniging"
},
"filter_progress": {
"name": "Filterverbruik"
},
@@ -520,12 +718,27 @@
"fridge_temperature": {
"name": "Koelkasttemperatuur"
},
"kimchi_ripening_status": {
"name": "{instance_name} rijpingsstatus"
},
"kimchi_ripening_remaining": {
"name": "{instance_name} resterende rijptijd"
},
"kimchi_rack_count": {
"name": "{instance_name} aantal rekken"
},
"hood_filter_capacity": {
"name": "Filtercapaciteit"
},
"humidity": {
"name": "Luchtvochtigheid"
},
"hood_filter_usage": {
"name": "Filterverbruik"
},
"humidity": {
"name": "Luchtvochtigheid"
},
"instance_temperature": {
"name": "Temperatuur {instance_name}"
},
@@ -559,6 +772,12 @@
"oven_state": {
"name": "Status ovenruimte"
},
"cavity_state": {
"name": "Status ovenruimte"
},
"power_level": {
"name": "Vermogensniveau"
},
"paired_hood_fan_speed": {
"name": "Ventilatorsnelheid gekoppelde afzuigkap"
},
@@ -574,6 +793,15 @@
"power_watts": {
"name": "Vermogen"
},
"probe_battery": {
"name": "Sonde batterij"
},
"probe_target_temperature": {
"name": "Doeltemperatuur sonde"
},
"probe_temperature": {
"name": "Temperatuur sonde"
},
"progress": {
"name": "Voortgang"
},
@@ -589,12 +817,30 @@
"selfcheck_status": {
"name": "Status zelfcontrole"
},
"sterilize_last_time": {
"name": "Laatste sterilisatie"
},
"sterilize_period": {
"name": "Sterilisatie-interval"
},
"sterilize_plan_time": {
"name": "Geplande sterilisatie"
},
"sterilize_run_time": {
"name": "Sterilisatieduur"
},
"super_fine_dust": {
"name": "Ultrafijnstof"
},
"warming_center_state": {
"name": "Status warmhoudzone"
},
"water_liters": {
"name": "Waterverbruik"
},
"waterpurifier_status": {
"name": "Status"
},
"machine_state": {
"name": "Machinestatus",
"state": {
@@ -629,6 +875,21 @@
"auto_clean": {
"name": "Automatisch reinigen"
},
"display": {
"name": "Display"
},
"pet_filter_activation": {
"name": "Huisdierfilter actief"
},
"auto_empty": {
"name": "Automatisch legen"
},
"dustbin_auto_close": {
"name": "Stofreservoir automatisch sluiten"
},
"uvc_intensive_mode": {
"name": "Intensieve UV-C-modus"
},
"auto_door_opener": {
"name": "Automatische deuropener"
},
@@ -641,6 +902,9 @@
"bubble_soak": {
"name": "Bubble Soak"
},
"buzz_lock": {
"name": "Zoemerslot"
},
"cabinet_light_dim": {
"name": "Geleidelijk feller"
},
@@ -650,6 +914,12 @@
"child_lock": {
"name": "Kinderslot"
},
"coldwater_lock": {
"name": "Koudwaterslot"
},
"cooktop_child_lock": {
"name": "Kinderslot"
},
"defrost_delay": {
"name": "Ontdooien uitstellen"
},
@@ -659,9 +929,18 @@
"fast_preheat": {
"name": "Snel voorverwarmen"
},
"favorite_capacity_enabled": {
"name": "Favoriete capaciteit"
},
"favorite_coffee_enabled": {
"name": "Favoriete koffie"
},
"fridge_sound": {
"name": "Geluid"
},
"hotwater_lock": {
"name": "Heetwaterslot"
},
"ice_maker_enabled": {
"name": "IJsmaker"
},
+466
View File
@@ -0,0 +1,466 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/airlevelcheck/vs/0",
"rep": {
"x.com.samsung.da.sensingState": "NonProcessing",
"x.com.samsung.da.lastSensingTime": "1785157841",
"x.com.samsung.da.lastSensingLevel": "Kr1",
"x.com.samsung.da.periodicSensingSkipStatus": "Off",
"x.com.samsung.da.periodicSensingSkipTime": "00000000",
"x.com.samsung.da.periodicSensingActivationState": "On",
"x.com.samsung.da.autoExeState": "Off",
"x.com.samsung.da.supportedAutoExeState": [
"Off",
"Airpurify",
"Alarm"
],
"x.com.samsung.da.startSensingOnce": "Off"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-27T13:18:51",
"x.com.samsung.da.state": "Deleted"
}
],
"rt": [
"x.com.samsung.da.alarms"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "3B000100000A0000000000000000",
"x.com.samsung.da.id": "VTL",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "2650000000",
"x.com.samsung.da.airconOptionList": [
"AI_PURIFY",
"WELCOMECARE",
"DR"
]
}
},
{
"href": "/da/softreset/vs/0",
"rep": {
"x.com.samsung.da.softwarereset": "false"
}
},
{
"href": "/devicespecificinfo/vs/0",
"rep": {
"x.com.samsung.da.deviceActive": true
}
},
{
"href": "/display/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/dnd/autosleep/vs/0",
"rep": {
"x.com.samsung.da.visible": "true",
"x.com.samsung.da.startTime": "00:00:00",
"x.com.samsung.da.endTime": "00:00:00",
"x.com.samsung.da.useTimeSetting": "false",
"x.com.samsung.da.functionState": "false"
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.start": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.durationminutes": "0",
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativeDate": "1785158301",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativePower": "32428",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePowerType": "total"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/hepafilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "70",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterCapacity": "8760",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable"
],
"x.com.samsung.da.filterStatus": "normal"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.modelNum": "TP1X_DA-AC-AIR-01031_0000|10268241|70000721001813CC4D1A490301082100",
"x.com.samsung.da.description": "TP1X_DA-AC-AIR-01031_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02660A260401",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.newVersionAvailable": "0",
"x.com.samsung.da.number": "02682A25042102,02683A25031801"
}
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AP2",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 1
}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/light/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.modes": [
"Smart"
],
"x.com.samsung.da.supportedModes": [
"Smart",
"Max",
"Mid",
"WindFree",
"Sleep"
],
"x.com.samsung.da.options": [
"OptionCode_23418",
"SmartSleep_Off",
"WelcomeCare_On",
"Pollution_Off",
"ProtectOperation_Off",
"UpdateAllow_NotAllowed"
],
"rt": [
"x.com.samsung.da.mode"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/panel/vs/0",
"rep": {
"status": "Close"
}
},
{
"href": "/personality/presence/vs/0",
"rep": {}
},
{
"href": "/petfilteractivation/vs/0",
"rep": {
"status": "Off"
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On",
"operationNumber": "36",
"displayCondition": "Enable"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "true",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "3F00000000000000000000",
"x.com.samsung.da.id": "VTL",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/sensors/vs/0",
"rep": {
"x.com.samsung.da.cleanLevel": "1",
"x.com.samsung.da.total": "5",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Sensor for CleanLevel",
"x.com.samsung.da.type": "CleanLevel",
"x.com.samsung.da.value": [
"1"
]
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Sensor for Odor",
"x.com.samsung.da.type": "Odor",
"x.com.samsung.da.value": [
"1"
]
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Sensor for Dust",
"x.com.samsung.da.type": "Dust",
"x.com.samsung.da.value": [
"5",
"1"
]
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Sensor for FineDust",
"x.com.samsung.da.type": "FineDust",
"x.com.samsung.da.value": [
"5",
"1"
]
},
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Sensor for SuperFineDust",
"x.com.samsung.da.type": "SuperFineDust",
"x.com.samsung.da.value": [
"5",
"1"
]
}
],
"rt": [
"x.com.samsung.da.sensors"
],
"if": [
"oic.if.baseline",
"oic.if.s"
]
}
},
{
"href": "/settings/sound/mode/vs/0",
"rep": {
"mode": "mute",
"supportedModes": [
"mute",
"buzzer"
]
}
},
{
"href": "/settings/sound/output/vs/0",
"rep": {
"deviceType": "buzzer"
}
},
{
"href": "/settings/sound/volume/vs/0",
"rep": {
"level": "0",
"minLevel": "0",
"maxLevel": "3",
"resolution": "1"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "Micom",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "12250421",
"x.com.samsung.da.currentVersionInfo": "10000000",
"otnStatus": "None",
"flashingProgress": "0",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"scheduledTime": "None",
"swVersionInfo": {
"platform": "Tizen Lite",
"oneUiVersion": "7.0 Air purifier",
"osVersion": "4.0"
},
"otnList": [
{
"type": "WIFI",
"modelId": "AVT-KR-TP1-24-AXXX00",
"versions": [
"12260401"
],
"visVersion": "260401"
},
{
"type": "Micom",
"modelId": "895010268241FFFFFFFF",
"versions": [
"25042102",
"FFFFFFFF"
],
"visVersion": "250421"
},
{
"type": "Micom",
"modelId": "09501026824110268341",
"versions": [
"25042102",
"25031801"
],
"visVersion": "250421"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "Branden_Summit"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
}
]
}
+476
View File
@@ -0,0 +1,476 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "54",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Smart",
"Speed",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "Off",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "0",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Low",
"Mid",
"High",
"Turbo"
]
}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Left_And_Right",
"x.com.samsung.da.supportedModes": [
"Fix",
"Up_And_Low",
"Left_And_Right",
"All"
]
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-27T06:07:25",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-27T06:07:25",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "26.0",
"x.com.samsung.da.current": "30.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "18",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 30.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 26.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "0.000000",
"x.com.samsung.da.cumulativePower": "3193591",
"x.com.samsung.da.cumulativeSavedPower": "158331",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 0.0
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Auto",
"Cool",
"Dry",
"Wind"
],
"x.com.samsung.da.modes": [
"Dry"
],
"x.com.samsung.da.options": [
"Sleep_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_270",
"OutdoorConnection_Connected",
"OutdoorTemp_88",
"CoolCapa_53",
"WarmCapa_0",
"Light_Off",
"Volume_100",
"StopAutoClean_Idle",
"Autoclean_Off",
"DiagnosisAI_Off",
"ProgressDiagnosisAI_1",
"ResultDiagnosisAI_Normal",
"SmartCoolClean_Off",
"ProgressSmartClean_0",
"FreezeAlarmSetting_On",
"DesiredFreezeAlarm_112",
"WashAlarm_Off",
"OptionCode_56440",
"ExtendOptionCode_246413",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_0",
"WelcomeCoolingState_On"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off",
"x.com.samsung.da.displaycondition": "Enable"
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ARA-WW-TP1-22-COMMON|10229641|60010535001511014600083200800000",
"x.com.samsung.da.description": "ARA-WW-TP1-22-COMMON",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "010",
"x.com.samsung.da.diagMinVersion": "1.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.serialNumOption": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02378A260327",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102296A23012700",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102295A22113000,102299A10000300",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+08:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"PRODUCT_GLOBAL",
"AI_RAC_GLOBAL_COOLONLY_3.0",
"AI_3.0",
"Auto_To_AI"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "64"
}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 1,
"start": "2026-07-27T05:07:32Z",
"duration": 20,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "1",
"x.com.samsung.da.duration": "20:47:00",
"x.com.samsung.da.drlcStartTime": "2026-07-27T05:07:32Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "000000B4012C016102490C000000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 1
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "ARA-WW-TP1-22-COMMON",
"versions": [
"11260327"
],
"visVersion": "260327"
},
{
"type": "Micom",
"modelId": "",
"versions": [
"23012700",
"FFFFFFFF"
],
"visVersion": "230127"
},
{
"type": "Micom",
"modelId": "",
"versions": [
"23012700",
"FFFFFFFF"
],
"visVersion": "230127"
}
]
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Kuala_Lumpur",
"offset": "+08:00",
"DST": "OFF"
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": "0",
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "dreamer"
}
}
]
}
@@ -0,0 +1,515 @@
{
"meta": {
"model": "TP1X_DA-AC-RAC-01001_0000",
"device_type": "airconditioner",
"source": "user diagnostics (scrubbed)",
"note": "Cool-only global TP1X RAC variant (airconOptionList AI_RAC_GLOBAL_COOLONLY_3.0). Unlike the other TP1X_DA-AC-RAC dumps, its /otninformation/vs/0 ships no swVersionInfo block, so oneUiVersion is empty and detection must fall back to the hyphenated '-RAC-' modelNum token in for_device_by_model. Adds two hrefs absent from the other AC dumps -- /stepcontrol/vs/0 (manual airflow step) and /remotedeviceinfo/vs/0 (empty paired-device list), both ignored -- and exposes Samsung WindFree via the convenient-mode codes Nano/NanoSleep (in place of the Smart code on other boards; confirmed by an off-vs-on dump diff)."
},
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "100",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "wash",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Speed",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "Off",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "0",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Low",
"Mid",
"High",
"Turbo"
]
}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Fix",
"x.com.samsung.da.supportedModes": [
"Fix",
"Up_And_Low",
"Left_And_Right",
"All"
]
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T15:24:44",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm",
"x.com.samsung.da.triggeredTime": "2026-07-26T15:24:44",
"x.com.samsung.da.state": "Created"
}
]
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "25.0",
"x.com.samsung.da.current": "20.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "16",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 20.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 25.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "0.000000",
"x.com.samsung.da.cumulativePower": "445938",
"x.com.samsung.da.cumulativeSavedPower": "81528",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 0.0
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Auto",
"Cool",
"Dry",
"Wind"
],
"x.com.samsung.da.modes": [
"Auto"
],
"x.com.samsung.da.options": [
"Sleep_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_240",
"OutdoorTemp_84",
"CoolCapa_35",
"WarmCapa_0",
"Light_Off",
"Volume_Mute",
"StopAutoClean_Idle",
"Autoclean_Off",
"DiagnosisAI_Off",
"ProgressDiagnosisAI_0",
"ResultDiagnosisAI_Normal",
"OptionCode_52344",
"ExtendOptionCode_230029",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_0",
"WelcomeCoolingState_Off"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off",
"causeSource": "DEFT",
"operationNumber": "0"
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_DA-AC-RAC-01001_0000|10247441|60010523001811014E00002200D00000",
"x.com.samsung.da.description": "TP1X_DA-AC-RAC-01001_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AR2",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02646A260327",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102474A23112200",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102702A24041900,102579A10000200",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "-03:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"PRODUCT_GLOBAL",
"AI_RAC_GLOBAL_COOLONLY_3.0",
"AI_3.0",
"Auto_To_AI"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "66"
}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 1,
"start": "2026-07-26T12:01:41Z",
"duration": 23,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "1",
"x.com.samsung.da.duration": "23:59:00",
"x.com.samsung.da.drlcStartTime": "2026-07-26T12:01:41Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "000000A0012C0161024904000000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/stepcontrol/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"80",
"60",
"40",
"Power"
]
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 1
}
},
{
"href": "/remotedatacontrol/vs/0",
"rep": {
"x.com.samsung.da.status": "Off",
"x.com.samsung.da.connectionStatus": "Disconnected"
}
},
{
"href": "/remotetemperature/vs/0",
"rep": {
"x.com.samsung.da.temperature": "",
"x.com.samsung.da.unit": "",
"x.com.samsung.da.error": ""
}
},
{
"href": "/remotedeviceinfo/vs/0",
"rep": {
"x.com.samsung.da.didList": ""
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "ARA-WW-TP1-24-ARXX00",
"versions": [
"11260327"
],
"visVersion": "260327"
},
{
"type": "Micom",
"modelId": "045210247441FFFFFFFF",
"versions": [
"23112200",
"FFFFFFFF"
],
"visVersion": "231122"
},
{
"type": "Micom",
"modelId": "04521027024110257941",
"versions": [
"24041900",
"10000200"
],
"visVersion": "240419"
}
]
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "America/Sao_Paulo",
"offset": "-03:00",
"DST": "OFF"
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": "0",
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "**REDACTED**"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
}
]
}
+380
View File
@@ -0,0 +1,380 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-25T08:19:03"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-25T08:19:03"
}
]
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"HOMECARE_WIZARD_V2",
"PRODUCT_GLOBAL",
"AI_RAC_GLOBAL_2.0",
"AI_2.0",
"Auto_To_AI",
"AI_Heat"
]
}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 0.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "0",
"x.com.samsung.da.cumulativePower": "320466",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+00:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "41",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "42"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ARTIK051_PRAC_20K|10217841|60010519001411010200001000000000",
"x.com.samsung.da.description": "ARTIK051_PRAC_20K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.serialNumOption": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02181A230313",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "20082000,FFFFFFFF",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Outdoor",
"x.com.samsung.da.number": "20091600,10000400"
}
]
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Smart",
"Speed",
"MotionIndirect",
"MotionDirect",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Cool",
"Dry",
"Wind",
"Auto",
"Heat"
],
"x.com.samsung.da.modes": [
"Dry"
],
"x.com.samsung.da.options": [
"Sleep_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"MotionState_Normal",
"AiTempChanged_Off",
"AiTemp_240",
"OutdoorTemp_87",
"CoolCapa_25",
"WarmCapa_32",
"Light_Off",
"Volume_100",
"MotionMode_Default",
"OptionCode_56376",
"ExtendOptionCode_781",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_0",
"WelcomeCoolingState_Off"
]
}
},
{
"href": "/option/airpurify/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "On",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/sensors/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Sensor for CleanLevel",
"x.com.samsung.da.type": "CleanLevel",
"x.com.samsung.da.value": [
"0"
]
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Sensor for Odor",
"x.com.samsung.da.type": "Odor",
"x.com.samsung.da.value": [
"0"
]
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Sensor for Dust",
"x.com.samsung.da.type": "Dust",
"x.com.samsung.da.value": [
"0",
"0"
]
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Sensor for FineDust",
"x.com.samsung.da.type": "FineDust",
"x.com.samsung.da.value": [
"0",
"0"
]
},
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Sensor for SuperFineDust",
"x.com.samsung.da.type": "SuperFineDust",
"x.com.samsung.da.value": [
"0",
"0"
]
}
]
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 27.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 26.0
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "26.0",
"x.com.samsung.da.current": "27.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "18",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Fix",
"x.com.samsung.da.supportedModes": [
"Fix",
"All",
"Up_And_Low",
"Left_And_Right"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "0",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Low",
"Mid",
"High",
"Turbo"
]
}
}
]
}
@@ -0,0 +1,590 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": 0,
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-27T11:59:06",
"x.com.samsung.da.state": "Deleted"
}
],
"rt": [
"x.com.samsung.da.alarms"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/anomalyload/vs/0",
"rep": {
"operation": "Off",
"mode": "Alarm",
"supportedModes": [
"Alarm",
"PowerSaving"
],
"savingTime": "20",
"supportedSavingTime": [
"20",
"40",
"60"
]
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "000000A0012C01610CC90C0F0000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"PRODUCT_GLOBAL",
"AI_GLOBAL_COOLONLY_4.0",
"AI_3.0",
"Auto_To_AI",
"ENERGY_2.0",
"HOMECARE_WIZARD_V2",
"DR",
"SingleCommand_1"
],
"InstalledRoomSize": "0.0",
"SkipInstalledRoomSize": "false",
"RoomSizeMenuNumber": "Manual"
}
},
{
"href": "/da/softreset/vs/0",
"rep": {
"x.com.samsung.da.softwarereset": "false"
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.start": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.durationminutes": "0",
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativeDate": "1785153515",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativePower": "47536",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePowerType": "total"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+08:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterCapacity": "180",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
],
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterUsage": "44",
"x.com.samsung.da.filterDesiredUsage": "180",
"x.com.samsung.da.supportedFilterDesiredUsage": [
"180",
"300",
"500",
"700"
]
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "46"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.modelNum": "TP1X_DA-AC-RAC-01011_0000|10281241|6001051A001911018E0049300002A900",
"x.com.samsung.da.description": "TP1X_DA-AC-RAC-01011_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.serialNumOption": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02825A260401",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.newVersionAvailable": "0",
"x.com.samsung.da.number": "02812A25111800,FFFFFFFFFFFFFF"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.newVersionAvailable": "0",
"x.com.samsung.da.number": "02813A25101500,FFFFFFFFFFFFFF"
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.newVersionAvailable": "0",
"x.com.samsung.da.number": "FFFFFFFFFFFFFF,FFFFFFFFFFFFFF"
}
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AR2",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 0
}
},
{
"href": "/light/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/mds/absencemonitoring/vs/0",
"rep": {}
},
{
"href": "/mds/absencestate/vs/0",
"rep": {}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Smart",
"Speed",
"Nano",
"NanoSleep",
"DryComfort"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.modes": [
"Cool"
],
"workingMode": "Cool",
"x.com.samsung.da.supportedModes": [
"Auto",
"Cool",
"Dry",
"Fan"
],
"x.com.samsung.da.options": [
"OptionCode_56416",
"Sleep_0",
"SleepRemainTime_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_240",
"Volume_100",
"DiagnosisAI_Off",
"ProgressDiagnosisAI_0",
"ResultDiagnosisAI_Normal",
"SmartCoolClean_Off",
"ProgressSmartClean_0",
"OutDoorVentil_Off",
"InDoorVentil_Off",
"FreezeAlarmSetting_Off",
"DesiredFreezeAlarm_240",
"WashAlarm_Off",
"ExtendOptionCode_246413",
"UpdateAllow_NotAllowed",
"DurationOn_0",
"WelcomeCoolingState_Off"
],
"rt": [
"x.com.samsung.da.mode"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.settingStatus": "Off",
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
],
"defaultSettingStatus": "On"
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off",
"rt": [
"x.com.samsung.da.option.muteonce"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/personality/presence/vs/0",
"rep": {}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off",
"operationNumber": "2",
"displayCondition": "Enable"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "8EFFFFFFFF101E121EFFFFFFFFFFFF000001001F0001000000000000009C00FFFF1E00",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/selfcheck/vs/0",
"rep": {
"x.com.samsung.da.start": "Cancel",
"x.com.samsung.da.status": "Ready",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.result": "NA",
"x.com.samsung.da.supportedActions": [
"Start",
"Cancel"
],
"x.com.samsung.da.error": [
"DA_ERROR_NONE"
]
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.current": "29.0",
"x.com.samsung.da.desired": "18.0",
"x.com.samsung.da.minimum": "16",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.increment": "1",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/wind/oscillation/vs/0",
"rep": {
"vertical": "Fix",
"supportedVertical": [
"Swing",
"Fix"
],
"verticalAngle": "4",
"supportedVerticalAngle": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"horizontal": "Fix",
"supportedHorizontal": [
"Swing",
"Fix"
],
"horizontalSwingMode": "AllSwing",
"supportedHorizontalSwingMode": [
"AllSwing",
"LeftSwing",
"RightSwing"
],
"horizontalAngle": "3",
"supportedHorizontalAngle": [
"1",
"2",
"3",
"4",
"5"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "1",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Low",
"Mid",
"High",
"Turbo"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"otnStatus": "None",
"flashingProgress": "0",
"otnCompleteDate": "noHistory",
"scheduledTime": "None",
"swVersionInfo": {
"platform": "Tizen Lite",
"oneUiVersion": "7.0 Air conditioner",
"osVersion": "4.0"
},
"otnList": [
{
"type": "WIFI",
"modelId": "ARA-WW-TP1-26-AR6X00MG",
"versions": [
"11260401"
],
"visVersion": "260401"
},
{
"type": "Micom",
"modelId": "845241131741FFFFFFFF",
"versions": [
"25102900",
"FFFFFFFF"
],
"visVersion": "251029"
},
{
"type": "Micom",
"modelId": "045210281241FFFFFFFF",
"versions": [
"25111800",
"FFFFFFFF"
],
"visVersion": "251118"
},
{
"type": "Micom",
"modelId": "045210281341FFFFFFFF",
"versions": [
"25101500",
"FFFFFFFF"
],
"visVersion": "251015"
},
{
"type": "Micom",
"modelId": "0452FFFFFFFFFFFFFFFF",
"versions": [
"FFFFFFFF",
"FFFFFFFF"
],
"visVersion": "999999"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Kuala_Lumpur",
"offset": "+08:00",
"DST": "OFF"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "K9 Unit"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
},
{
"href": "/dginformation/vs/0",
"rep": {
"enrolmentstatus": "Unknown",
"devicestate": "Unknown",
"lockstatus": "Unknown",
"nextduedate": "",
"workingminutes": 0,
"paymentinfo": {
"emiplan": "Unknown",
"currency": "Unknown",
"totalemi": 0,
"totalemipaid": 0
}
}
},
{
"href": "/temperature/desired/0",
"rep": {
"temperature": 25
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
}
]
}
+523
View File
@@ -0,0 +1,523 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": "0",
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T06:26:40",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T06:26:40",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "8D0D00B4012C3F21064804000000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "2647000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"AI_RAC_KOREA_COOLONLY_3.0",
"AI_3.0",
"Auto_To_AI"
]
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 0,
"start": "1970-01-01T00:00:00Z",
"duration": 0,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.duration": "00:00:00",
"x.com.samsung.da.drlcStartTime": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 244.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "244.000000",
"x.com.samsung.da.cumulativePower": "11001",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePowerType": "total"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "20",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "60"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_DA_AC_WAC_01001_0000|10254341|60050000001711014E00402000002000",
"x.com.samsung.da.description": "TP1X_DA_AC_WAC_01001_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AW0",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02545A260601",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "02543A24061800,FFFFFFFFFFFFFF",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Outdoor",
"x.com.samsung.da.number": "02580A10000100,FFFFFFFFFFFFFF"
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Touch IC",
"x.com.samsung.da.number": "02553A23031600,FFFFFFFFFFFFFF"
}
]
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 0
}
},
{
"href": "/light/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Quiet",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"AIComfort",
"Cool",
"Dry",
"Fan"
],
"x.com.samsung.da.modes": [
"Cool"
],
"x.com.samsung.da.options": [
"OnTimer_0",
"OffTimer_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_230",
"Volume_Mute",
"OutdoorTemp_97",
"CoolCapa_0",
"StopAutoClean_Idle",
"Autoclean_Off",
"OptionCode_51320",
"ExtendOptionCode_230093",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_93",
"WelcomeCoolingState_Off"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "Off",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "AWA-KR-TP1-23-AW7000",
"versions": [
"15260601"
],
"visVersion": "260601"
},
{
"type": "Micom",
"modelId": "042010254341FFFFFFFF",
"versions": [
"24061800",
"FFFFFFFF"
],
"visVersion": "240618"
},
{
"type": "Micom",
"modelId": "042010258041FFFFFFFF",
"versions": [
"10000100",
"FFFFFFFF"
],
"visVersion": "100001"
},
{
"type": "Micom",
"modelId": "042010255341FFFFFFFF",
"versions": [
"23031600",
"FFFFFFFF"
],
"visVersion": "230316"
}
]
}
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": true
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On",
"causeSource": "SMTS"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "true",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "8DFFFFFFFF121E121E0000FFFFFFFFFFFF01000000011F0000000000000000001F8C00",
"x.com.samsung.da.id": "WAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/selfcheck/vs/0",
"rep": {
"x.com.samsung.da.start": "Cancel",
"x.com.samsung.da.status": "Ready",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.result": "NA",
"x.com.samsung.da.supportedActions": [
"Start",
"Cancel"
],
"x.com.samsung.da.error": [
"DA_ERROR_NONE"
]
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 30.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 30.0
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "30.0",
"x.com.samsung.da.current": "30.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "18",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/welcome/temperature/vs/0",
"rep": {
"operatingStatus": "None",
"requestId": "0000"
}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Fix",
"x.com.samsung.da.supportedModes": [
"Fix",
"Left_And_Right"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "1",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4",
"5"
],
"x.com.samsung.da.modesName": [
"Auto",
"1",
"2",
"3",
"4",
"5"
]
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "**REDACTED**"
}
}
]
}
+386
View File
@@ -0,0 +1,386 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "100",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "224",
"x.com.samsung.da.filterStatus": "wash",
"x.com.samsung.da.filterCapacity": "224",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"washable"
],
"x.com.samsung.da.supportedFilterDesiredUsage": [
"224",
"300",
"500",
"700"
]
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "On",
"x.com.samsung.da.progress": "100",
"cleaningTime": "30",
"minCleaningTime": "10",
"maxCleaningTime": "60",
"cleaningTimeUnit": "10",
"x.com.samsung.da.supportedStatus": [
"Start",
"TimedClean",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"TimedClean",
"Off"
]
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T10:35:53",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "WaterTankFull_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T10:35:53",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "259.000000",
"x.com.samsung.da.cumulativePower": "183099",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePowerType": "total"
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Smart",
"Max",
"High",
"Medium",
"Quiet",
"ClothesDrying"
],
"x.com.samsung.da.modes": [
"Smart"
],
"x.com.samsung.da.options": [
"Volume_Mute",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"WelcomeCoolingState_Off"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On",
"causeSource": "SMTS"
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_DA_AC_DHM_01001_0000|10253841|77000000001700000A00000000000000",
"x.com.samsung.da.description": "TP1X_DA_AC_DHM_01001_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AY0",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02544A260401",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "02538A24032700,FFFFFFFFFFFFFF",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Outdoor",
"x.com.samsung.da.number": "02590A10000100,FFFFFFFFFFFFFF"
},
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Touch IC",
"x.com.samsung.da.number": "02552A23020200,FFFFFFFFFFFFFF"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"PRODUCT_GLOBAL",
"AI_RAC_GLOBAL_2.0",
"AI_Heat"
]
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "47",
"x.com.samsung.da.desiredHumidity": "50",
"increment": "5",
"x.com.samsung.da.fivepercentHumidity": "46"
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.durationminutes": "0",
"x.com.samsung.da.start": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "20001E46070A5A00000000000000",
"x.com.samsung.da.id": "DHM",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/da/softreset/vs/0",
"rep": {
"x.com.samsung.da.softwarereset": "false"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 0
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "ADH-WW-TP1-23-AY7100",
"versions": [
"18260401"
],
"visVersion": "260401"
},
{
"type": "Micom",
"modelId": "042110253841FFFFFFFF",
"versions": [
"24032700",
"FFFFFFFF"
],
"visVersion": "240327"
},
{
"type": "Micom",
"modelId": "042110259041FFFFFFFF",
"versions": [
"10000100",
"FFFFFFFF"
],
"visVersion": "100001"
},
{
"type": "Micom",
"modelId": "042110255241FFFFFFFF",
"versions": [
"23020200",
"FFFFFFFF"
],
"visVersion": "230202"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "3F1E461E461E46FFFFFFFF1E4600",
"x.com.samsung.da.id": "DHM",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/welcome/humidity/vs/0",
"rep": {
"requestId": "0000",
"operatingStatus": "None"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
}
]
}
+391
View File
@@ -0,0 +1,391 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.countryCode": "US"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/course/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.options": [
"DeviceType_0152",
"UpdateAllow_NotAllowed",
"Course_01",
"AiOption_On",
"MixedLoadBell_Disable",
"MixedLoadBellNoti_Nothing",
"LaundryOutTime_0",
"SeamlessControl_Enable",
"KidsLockBypass_On",
"DetergentOnce_1",
"DetergentLeft_0",
"DetergentBase_5",
"DetergentAlarm_Off",
"DetergentType_3",
"DetergentTotal_0",
"SpecialFunction_20",
"AvailableDelayTime_39",
"LaundryPlannerUserSetTime_0",
"ProgressTimeSet_B20870B400B4",
"WrinklePreventRunning_Off",
"DryTime_0",
"SendToDevice_Off",
"GMT_F6",
"DryTimeSet_0A00000000500A005A00000000000000001E0A005A00000000000000001414005A000000000000000000000000000000000000000000000000000000000000000000000000140A005A280A005A",
"EnergyLevelSet_0504040504040205020204040305020203030103",
"MostUsed_068A3ED000",
"WrinklePreventSet_0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F",
"MixedLoadBellSet_02FF02FFFF02FFFFFF0202FF02FFFF02FFFFFF",
"GeoFenceAlarm",
"UsagesDB_ok",
"EnergyKW_396",
"DrumCleanLog_Empty",
"TimeSync_NotSupported"
],
"x.com.samsung.da.supportedOptions": [
"2018410D33E06833ED0002F8520D33E178520D3083E8520D000078102D33E338520D520358520D000348520D0000E8520D33E058520D33E308410D308318410D33E098410D3080F8204D308328308D33E2E8102D308368000D0000D8102D000"
]
}
},
{
"href": "/cycleinterface/vs/0",
"rep": {
"x.com.samsung.da.cycleInterfaceEnabled": "On"
}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "-500",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePower": "2323800",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.cumulativeDate": "1784991600",
"x.com.samsung.da.cumulativeDateUTC": "1785009600"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "-05:00"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "DA_WM_TP1_21_COMMON|20286441|300000010015110002A3031700000000",
"x.com.samsung.da.description": "DA_WM_TP1_21_COMMON_DVE50A8800_8600/DC92-02835A_0080",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "310",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "DA_WM_TP1_21_COMMON|20286441|300000010015110002A3031700000000",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02986A260118(A182)",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Firmware_1_DB_20286441210514150FFFFF202835412105131904FFFF(01522028644120283541_30000000)(FileDown:0)(Type:0)",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "02864A21051415,02835A21051319",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/kidslock/0",
"rep": {
"value": false
}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/operational/state/0",
"rep": {
"currentMachineState": "**REDACTED**",
"machineStates": "**REDACTED**",
"jobStates": [
"None",
"Drying",
"Cooling",
"Finish"
],
"currentJobState": "None",
"remainingTime": "01:15:00",
"progressPercentage": "1"
}
},
{
"href": "/operational/state/vs/0",
"rep": {
"x.com.samsung.da.state": "Ready",
"x.com.samsung.da.remainingTime": "01:15:00",
"x.com.samsung.da.progressPercentage": "1",
"x.com.samsung.da.progress": "None",
"x.com.samsung.da.delayEndTime": "00:00:00",
"x.com.samsung.da.supportedProgress": [
"None",
"Drying",
"Cooling",
"Finish"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "2026-03-04",
"otnList": [
{
"type": "WIFI",
"modelId": "DA_WM_TP1_21_COMMON",
"versions": [
"30260118"
],
"visVersion": "260118"
},
{
"type": "Micom",
"modelId": "01522028644120283541",
"versions": [
"21051415",
"21051319"
],
"visVersion": "210514"
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "10",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/remotectrl/0",
"rep": {
"value": false
}
},
{
"href": "/remotectrl/vs/0",
"rep": {
"x.com.samsung.da.remoteControlEnabled": "false"
}
},
{
"href": "/setting/vs/0",
"rep": {
"x.com.samsung.da.supportedSetLanguage": [
"en_US",
"ko_KR",
"fr_CA",
"es_MX",
"pt_BR"
],
"x.com.samsung.da.setLanguage": "en_US"
}
},
{
"href": "/st/dryercourse/vs/0",
"rep": {
"x.com.samsung.da.st.dryerMode": "Table_03_Course_01",
"x.com.samsung.da.st.courseTable": "Table_03"
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "America/Chicago",
"offset": "-05:00",
"DST": "ON"
}
},
{
"href": "/washer/vs/0",
"rep": {
"x.com.samsung.da.wrinklePrevent": "Off",
"x.com.samsung.da.waterTemperature": "Medium",
"x.com.samsung.da.supportedWaterTemperature": [
"None",
"ExtraLow",
"Low",
"MediumLow",
"Medium",
"High"
],
"x.com.samsung.da.dryLevel": "Normal",
"x.com.samsung.da.supportedDryLevel": [
"None",
"Damp",
"Less",
"Normal",
"More",
"Very"
],
"x.com.samsung.da.dryerType": "Electricity"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**"
}
},
{
"href": "/wm/editcourse/vs/0",
"rep": {
"x.com.samsung.da.editCourseList": "EditCourseList_0106",
"x.com.samsung.da.fixedCourseList": "FixedCourseList_0101"
}
},
{
"href": "/wm/jobbeginingstatus/vs/0",
"rep": {
"x.com.samsung.da.currentStatus": "None"
}
},
{
"href": "/wm/personalcourse/vs/0",
"rep": {
"x.com.samsung.da.courses": [
"F1_00",
"F2_00",
"F3_00",
"F4_00",
"F5_00",
"F6_00",
"F7_00",
"F8_00",
"F9_00",
"FA_00"
],
"x.com.samsung.da.maxCourseNum": "10"
}
},
{
"href": "/wm/setinfo/vs/0",
"rep": {
"x.com.samsung.da.isModelSettingWithoutSC": "true",
"x.com.samsung.da.aiCourse": "false",
"x.com.samsung.da.isModelSettingPowerOnOff": "false",
"x.com.samsung.da.modelCode": "M(None),W(DVE50A8600V/A3)"
}
},
{
"href": "/wm/welcomemsg/vs/0",
"rep": {}
}
]
}
+1 -7
View File
@@ -1,24 +1,18 @@
{
"state_keys": [
"airflow_fan",
"alarm_code",
"clean_level",
"device_active",
"diagnosis_status",
"display_light",
"dust",
"energy_kwh",
"energy_last_month_kwh",
"energy_saved_kwh",
"energy_this_month_kwh",
"fan_direction",
"fan_speed_level",
"filter_progress",
"fine_dust",
"odor",
"operating_mode",
"power_energy_kwh",
"power_switch",
"power_watts",
"super_fine_dust"
]
}
+27
View File
@@ -0,0 +1,27 @@
{
"state_keys": [
"alarm_code",
"child_lock",
"clean_level",
"device_active",
"display",
"display_light",
"dust",
"energy_kwh",
"energy_saved_kwh",
"fan",
"fine_dust",
"firmware_update",
"hepa_filter_status",
"hepa_filter_usage",
"mute_once",
"odor",
"panel_status",
"pet_filter_activation",
"power_switch",
"sound_mode",
"sound_output",
"sound_volume",
"super_fine_dust"
]
}
+3
View File
@@ -6,9 +6,12 @@
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"humidity",
"power_watts"
]
}
+17
View File
@@ -0,0 +1,17 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts"
]
}
+3
View File
@@ -5,10 +5,13 @@
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts"
]
@@ -6,10 +6,12 @@
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"selfcheck_error",
"selfcheck_result",
+1
View File
@@ -8,6 +8,7 @@
"climate",
"current_limit_enabled",
"current_limit_level",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
@@ -0,0 +1,17 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts"
]
}
@@ -5,8 +5,11 @@
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts"
]
+16
View File
@@ -0,0 +1,16 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"air_purify",
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"energy_kwh",
"humidity",
"power_watts"
]
}
@@ -0,0 +1,21 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"overload_protection_active",
"overload_protection_mode",
"selfcheck_error",
"selfcheck_result",
"selfcheck_status"
]
}
+20
View File
@@ -0,0 +1,20 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts",
"selfcheck_error",
"selfcheck_result",
"selfcheck_status"
]
}
+17
View File
@@ -0,0 +1,17 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"alarm_code",
"auto_clean",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"operating_mode",
"power_switch",
"power_watts",
"target_humidity"
]
}
+24
View File
@@ -0,0 +1,24 @@
{
"state_keys": [
"alarm_code",
"child_lock",
"completion_minutes",
"cycle",
"cycle_active",
"delay_start_hours",
"diagnosis",
"dry_level",
"dry_time",
"dryer_type",
"energy_kwh",
"finish_time",
"firmware_update",
"job_beginning_status",
"machine_state",
"power_switch",
"progress",
"progress_percentage",
"remote_control",
"wrinkle_prevent"
]
}
+32
View File
@@ -0,0 +1,32 @@
{
"state_keys": [
"alarm_code",
"burner_0_hot_surface",
"burner_0_pan_detected",
"burner_0_power_level",
"burner_0_state",
"burner_1_hot_surface",
"burner_1_pan_detected",
"burner_1_power_level",
"burner_1_state",
"burner_2_hot_surface",
"burner_2_pan_detected",
"burner_2_power_level",
"burner_2_state",
"cooktop_child_lock",
"cooktop_power",
"cooktop_state",
"energy_kwh",
"firmware_update",
"paired_hood_connected",
"paired_hood_fan_speed",
"paired_hood_firmware",
"paired_hood_light",
"paired_hood_model",
"paired_hood_power",
"probe_battery",
"probe_connected",
"probe_target_temperature",
"probe_temperature"
]
}
+22
View File
@@ -0,0 +1,22 @@
{
"state_keys": [
"alarm_code",
"cavity_state",
"child_lock",
"cloud_connected",
"cook_time",
"cooking_mode",
"cycle_active",
"door_open",
"energy_kwh",
"fan",
"finish_time",
"firmware_update",
"lamp",
"machine_state",
"operation_time_minutes",
"power_level",
"progress_percentage",
"sound"
]
}
+23
View File
@@ -0,0 +1,23 @@
{
"state_keys": [
"alarm_code",
"cavity_state",
"child_lock",
"cloud_connected",
"cook_time",
"cooking_mode",
"current_temp_c",
"cycle_active",
"door_open",
"energy_kwh",
"finish_time",
"firmware_update",
"machine_state",
"operation_time_minutes",
"power_level",
"progress_percentage",
"remote_control",
"setpoint",
"sound"
]
}
+6
View File
@@ -2,20 +2,26 @@
"state_keys": [
"alarm_code",
"burner_0_hot_surface",
"burner_0_pan_detected",
"burner_0_power_level",
"burner_0_state",
"burner_1_hot_surface",
"burner_1_pan_detected",
"burner_1_power_level",
"burner_1_state",
"burner_2_hot_surface",
"burner_2_pan_detected",
"burner_2_power_level",
"burner_2_state",
"burner_3_hot_surface",
"burner_3_pan_detected",
"burner_3_power_level",
"burner_3_state",
"child_lock",
"cloud_connected",
"cook_time",
"cooktop_child_lock",
"cooktop_power",
"cooktop_safety_shutoff_enabled",
"cooktop_state",
"current_temp_c",
+2
View File
@@ -1,5 +1,7 @@
{
"state_keys": [
"after_run_active",
"after_run_progress",
"air_sensing_state",
"alarm_code",
"auto_ventilation_action",
+27
View File
@@ -0,0 +1,27 @@
{
"state_keys": [
"alarm_code",
"child_lock",
"cloud_connected",
"cook_time",
"cooktop_running_state",
"current_temp_c",
"cycle_active",
"door_open",
"fast_preheat",
"finish_time",
"firmware_update",
"lamp",
"machine_state",
"natural_steam",
"operation_time_minutes",
"oven_mode",
"oven_setpoint",
"oven_state",
"power_switch",
"progress_percentage",
"remote_control",
"sound",
"warming_center_state"
]
}
+27
View File
@@ -0,0 +1,27 @@
{
"state_keys": [
"alarm_code",
"child_lock",
"cloud_connected",
"cook_time",
"cooktop_running_state",
"current_temp_c",
"cycle_active",
"door_open",
"fast_preheat",
"finish_time",
"firmware_update",
"lamp",
"machine_state",
"natural_steam",
"operation_time_minutes",
"oven_mode",
"oven_setpoint",
"oven_state",
"power_switch",
"progress_percentage",
"remote_control",
"sound",
"warming_center_state"
]
}
@@ -0,0 +1,16 @@
{
"state_keys": [
"alarm_code",
"defrost_active",
"defrost_delay",
"diagnosis_status",
"door_onedoorfreezer_open",
"firmware_update",
"freezer_setpoint",
"freezer_temperature",
"ice_maker_enabled",
"rapid_freezing",
"rapid_fridge",
"sabbath_mode"
]
}
@@ -0,0 +1,17 @@
{
"state_keys": [
"alarm_code",
"cooler_setpoint",
"cooler_temperature",
"defrost_active",
"defrost_delay",
"diagnosis_status",
"door_cooler_open",
"door_onedoorfreezer_open",
"firmware_update",
"ice_maker_enabled",
"rapid_freezing",
"rapid_fridge",
"sabbath_mode"
]
}
@@ -0,0 +1,24 @@
{
"state_keys": [
"alarm_code",
"bottom_mode",
"bottom_rack_count",
"bottom_ripening_remaining",
"bottom_ripening_status",
"diagnosis_status",
"door_open",
"energy_kwh",
"firmware_update",
"middle_mode",
"middle_rack_count",
"middle_ripening_remaining",
"middle_ripening_status",
"power_energy_kwh",
"power_watts",
"top_mode",
"top_open",
"top_rack_count",
"top_ripening_remaining",
"top_ripening_status"
]
}
+19
View File
@@ -0,0 +1,19 @@
{
"state_keys": [
"alarm_code",
"auto_empty",
"cleanstation_status",
"discharging_time",
"dustbag_full",
"dustbag_usage",
"dustbin_auto_close",
"energy_kwh",
"firmware_update",
"stick_status",
"uvc_emitted_time",
"uvc_finished_time",
"uvc_intensive_mode",
"uvc_operation_time",
"uvc_total_operation_time"
]
}
+30
View File
@@ -0,0 +1,30 @@
{
"state_keys": [
"alarm_code",
"child_lock",
"completion_minutes",
"cycle",
"cycle_active",
"delay_start_hours",
"detergent_low",
"detergent_quantity",
"detergent_water_hardness",
"diagnosis_status",
"drum_clean_cycles_remaining",
"energy_kwh",
"finish_time",
"firmware_update",
"job_beginning_status",
"machine_state",
"power_switch",
"progress",
"progress_percentage",
"remote_control",
"rinse_cycles",
"softener_concentration",
"softener_low",
"softener_quantity",
"spin_speed",
"wash_temperature"
]
}
+26
View File
@@ -0,0 +1,26 @@
{
"state_keys": [
"alarm_code",
"child_lock",
"completion_minutes",
"cycle",
"cycle_active",
"delay_start_hours",
"detergent_low",
"diagnosis_status",
"drum_clean_cycles_remaining",
"energy_kwh",
"finish_time",
"firmware_update",
"job_beginning_status",
"machine_state",
"power_switch",
"progress",
"progress_percentage",
"remote_control",
"rinse_cycles",
"softener_low",
"spin_speed",
"wash_temperature"
]
}
+27
View File
@@ -0,0 +1,27 @@
{
"state_keys": [
"alarm_code",
"buzz_lock",
"coldwater_lock",
"dispense_capacity",
"dispense_type",
"favorite_capacity",
"favorite_capacity_enabled",
"filter_clean_remain_time",
"filter_door_status",
"filter_status",
"filter_usage",
"firmware_update",
"hot_water_temperature",
"hotwater_lock",
"pouring",
"selfcheck_error",
"selfcheck_result",
"selfcheck_status",
"sterilize_last_time",
"sterilize_period",
"sterilize_plan_time",
"sterilize_run_time",
"waterpurifier_status"
]
}
+30
View File
@@ -0,0 +1,30 @@
{
"state_keys": [
"alarm_code",
"buzz_lock",
"coffee_brew_status",
"coldwater_lock",
"dispense_capacity",
"dispense_type",
"favorite_capacity",
"favorite_capacity_enabled",
"favorite_coffee_enabled",
"favorite_hotwater_temperature",
"filter_clean_remain_time",
"filter_door_status",
"filter_status",
"filter_usage",
"firmware_update",
"hot_water_temperature",
"hotwater_lock",
"pouring",
"selfcheck_error",
"selfcheck_result",
"selfcheck_status",
"sterilize_last_time",
"sterilize_period",
"sterilize_plan_time",
"sterilize_run_time",
"waterpurifier_status"
]
}
+243
View File
@@ -0,0 +1,243 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {
"rt": [
"x.com.samsung.da.alarms"
],
"if": [
"oic.if.baseline",
"oic.if.s"
],
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "CT_E_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T06:30:18"
}
]
}
},
{
"href": "/bluetooth/hood/status/vs/0",
"rep": {
"connectionState": "disconnected",
"micomModelId": "",
"firmwareVersion": "",
"power": "off",
"fanSpeed": 0,
"lampState": "off",
"timer": {}
}
},
{
"href": "/bluetooth/probe/status/vs/0",
"rep": {
"connectionState": "disconnected",
"batteryState": "normal",
"batteryPercentage": 0,
"operationBurnerNumber": -1,
"temperatureUnit": "C",
"targetTemperature": 0,
"currentTemperature": 0
}
},
{
"href": "/cooktop/recipe/status/vs/0",
"rep": {
"sequenceNumber": 160,
"operationBurnerNumber": 2,
"stageInfo": {
"numberOfStages": 0,
"cookingTimeList": []
},
"textData": {
"menu": ""
}
}
},
{
"href": "/cooktop/spec/vs/0",
"rep": {
"deviceType": "cooktop",
"micomModelId": "NV8500T-/KO4",
"supportedFeatureList": [
"kitchenService"
],
"numberOfBurners": 3,
"supportedBurnerList": [
0,
1,
2
],
"supportedPowerLevelList": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"boost",
"0",
"keepWarm"
],
"supportedRecipeProtocolVersion": 3
}
},
{
"href": "/cooktop/status/vs/0",
"rep": {
"sequenceNumber": 3214,
"power": "off",
"childLock": "off",
"operationState": "ready",
"additionalStateList": [
""
],
"burnerList": [
{
"burnerNumber": 0,
"mode": "normal",
"operationState": "ready",
"powerLevel": "0",
"hotSurfaceState": "normal",
"panDetection": true,
"timer": {
"operationState": "ready",
"cookingTime": 0,
"remainingTime": 0
}
},
{
"burnerNumber": 1,
"mode": "normal",
"operationState": "ready",
"powerLevel": "0",
"hotSurfaceState": "normal",
"panDetection": true,
"timer": {
"operationState": "ready",
"cookingTime": 0,
"remainingTime": 0
}
},
{
"burnerNumber": 2,
"mode": "normal",
"operationState": "ready",
"powerLevel": "0",
"hotSurfaceState": "normal",
"panDetection": true,
"timer": {
"operationState": "ready",
"cookingTime": 0,
"remainingTime": 0
}
}
]
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "-500",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePower": "212700",
"x.com.samsung.da.cumulativeUnit": "Wh"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_DA-KS-COOKTOP-01011|40459741|50000203001711000A00000000000000",
"x.com.samsung.da.description": "NV8500T-/KO4",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "26033000",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "04597A23021100, 04596A23080300",
"x.com.samsung.da.newVersionAvailable": "0"
}
],
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "KCA",
"x.com.samsung.da.diagTsId": "DA01"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"flashingProgress": "",
"otnTarget": "main",
"otnStatus": "None",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "AKS-WW-TP1-21-COOKTOP-2",
"versions": [
"40260330"
],
"visVersion": "260330"
},
{
"type": "Micom",
"modelId": "05114045974140459641",
"versions": [
"23021100",
"23080300"
],
"visVersion": "230803"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
}
]
}
+201
View File
@@ -0,0 +1,201 @@
{
"device0": [
{
"rt": ["x.com.samsung.devcol", "oic.wk.col"],
"if": ["oic.if.baseline", "oic.if.ll", "oic.if.b"]
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"flashingProgress": "",
"otnStatus": "None",
"otnList": [
{
"type": "WIFI",
"modelId": "AKS-WW-TP1-23-MICROWAVE-OTR",
"versions": ["40241114"],
"visVersion": "241114"
},
{
"type": "Micom",
"modelId": "07424047334140473241",
"versions": ["24071000", "23120700"],
"visVersion": "240710"
},
{
"type": "Micom",
"modelId": "074240475443FFFFFFFF",
"versions": ["23120800", "FFFFFFFF"],
"visVersion": "231208"
}
]
}
},
{
"href": "/connected/vs/0",
"rep": {
"x.com.samsung.da.connected": "On",
"rt": ["x.com.samsung.da.connected"],
"if": ["oic.if.baseline", "oic.if.s"]
}
},
{
"href": "/doors/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Door",
"x.com.samsung.da.openState": "Close"
}
],
"rt": ["x.com.samsung.da.doors"],
"if": ["oic.if.baseline", "oic.if.s"]
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_DA-KS-MICROWAVE-01051|40473341|50040000011811000A00000000000000",
"x.com.samsung.da.description": "ME7500D-/AA1",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "24111400",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "04733A24071000, 04732A23120700",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "04754C23120800",
"x.com.samsung.da.newVersionAvailable": "0"
}
],
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": ["errCode", "dump"],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "KM5",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01"
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": ["NoOperation", "MicroWave", "Autocook", "KeepWarm"],
"x.com.samsung.da.modes": ["NoOperation"],
"x.com.samsung.da.options": [
"DeviceType_ME7500D-/AA1",
"TimeAutoSync_On",
"weight_LBS",
"TimeSystem_12",
"Sound_On",
"RemindBeep_On",
"FilterRemind_Off",
"Lamp_Off"
],
"x.com.samsung.da.defaultMode": "MicroWave",
"rt": ["x.com.samsung.da.mode"],
"if": ["oic.if.baseline", "oic.if.a"]
}
},
{
"href": "/operational/state/vs/0",
"rep": {
"x.com.samsung.da.state": "Ready",
"x.com.samsung.da.operationTime": "00:00:00",
"x.com.samsung.da.remainingTime": "00:00:00",
"x.com.samsung.da.progressPercentage": "0",
"rt": ["x.com.samsung.da.operation"],
"if": ["oic.if.baseline", "oic.if.a"]
}
},
{
"href": "/alarms/vs/0",
"rep": {
"rt": ["x.com.samsung.da.alarms"],
"if": ["oic.if.baseline", "oic.if.s"],
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "OV_E_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-27T20:03:10"
}
]
}
},
{
"href": "/oven/vs/0",
"rep": {
"x.com.samsung.da.state": "Ready",
"x.com.samsung.da.recipe": "00000000000000",
"x.com.samsung.da.powerLevel": "0",
"rt": ["x.com.samsung.da.oven"],
"if": ["oic.if.baseline", "oic.if.s"]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "America/New_York",
"offset": "-04:00",
"DST": "ON"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "-500",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePower": "3400",
"x.com.samsung.da.cumulativeUnit": "Wh"
}
},
{
"href": "/hood/fanspeed/vs/0",
"rep": {
"x.com.samsung.da.hood.fanSpeed": "0",
"x.com.samsung.da.hood.supportedFanSpeed": ["0", "1", "2", "3", "4"],
"x.com.samsung.da.hood.settableMaxFanSpeed": "4",
"x.com.samsung.da.hood.settableMinFanSpeed": "0"
}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
}
]
}
File diff suppressed because one or more lines are too long
+8
View File
@@ -160,6 +160,14 @@
"href": "/da/softreset/vs/0",
"rep": {"x.com.samsung.da.softwarereset": "false"}
},
{
"href": "/afterrun/vs/0",
"rep": {
"x.com.samsung.da.runningProgress": "0",
"x.com.samsung.da.runningCancel": "Cancel",
"x.com.samsung.da.activationState": "Off"
}
},
{
"href": "/filter/hoodfilter/vs/0",
"rep": {
File diff suppressed because one or more lines are too long
File diff suppressed because one or more lines are too long
@@ -0,0 +1,201 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/bespoke/vs/0",
"rep": {
"x.com.samsung.da.BespokeProduct": "Off"
}
},
{
"href": "/defrost/delay/0",
"rep": {}
},
{
"href": "/defrost/delay/vs/0",
"rep": {}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/door/cooler/0",
"rep": {
"openState": "Close"
}
},
{
"href": "/door/onedoorfreezer/vs/0",
"rep": {
"x.com.samsung.da.openState": "Close"
}
},
{
"href": "/doors/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Door",
"x.com.samsung.da.openState": "Close"
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Door",
"x.com.samsung.da.openState": "Close"
}
]
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+01:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/icemaker/status/0",
"rep": {}
},
{
"href": "/icemaker/status/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ARTIK051_DONGLE_REF|00090741|00090028001130300100000000000000",
"x.com.samsung.da.description": "ARTIK_REF_17K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "WiFi Module",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "011120190711",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Micom",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "14040703,ffffffff",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/mode/0",
"rep": {
"supportedModes": [
"HOMECARE_WIZARD_V2",
"RVACATION_ON",
"RVACATION_OFF"
],
"modes": [
"RVACATION_OFF"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2",
"RVACATION_ON",
"RVACATION_OFF"
],
"x.com.samsung.da.modes": [
"RVACATION_OFF"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "Micom",
"x.com.samsung.da.newVersionAvailable": "false"
}
},
{
"href": "/refrigeration/0",
"rep": {
"defrost": false,
"rapidFreeze": false,
"rapidCool": false
}
},
{
"href": "/refrigeration/vs/0",
"rep": {
"x.com.samsung.da.rapidFridge": "Off"
}
},
{
"href": "/sabbath/vs/0",
"rep": {}
},
{
"href": "/temperature/current/cooler/0",
"rep": {
"range": [
1.0,
7.0
],
"units": "C",
"temperature": 3.0
}
},
{
"href": "/temperature/desired/cooler/0",
"rep": {
"range": [
1.0,
7.0
],
"units": "C",
"temperature": 3.0
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Fridge",
"x.com.samsung.da.desired": "3",
"x.com.samsung.da.current": "3",
"x.com.samsung.da.maximum": "7",
"x.com.samsung.da.minimum": "1",
"x.com.samsung.da.unit": "Celsius"
}
]
}
}
]
}
@@ -0,0 +1,184 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/bespoke/vs/0",
"rep": {
"x.com.samsung.da.BespokeProduct": "Off"
}
},
{
"href": "/defrost/delay/0",
"rep": {}
},
{
"href": "/defrost/delay/vs/0",
"rep": {}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/door/onedoorfreezer/vs/0",
"rep": {
"x.com.samsung.da.openState": "Close"
}
},
{
"href": "/doors/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Door",
"x.com.samsung.da.openState": "Close"
}
]
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+02:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/icemaker/status/0",
"rep": {}
},
{
"href": "/icemaker/status/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ARTIK051_DONGLE_REF|00127641|00080020001430300100000000000000",
"x.com.samsung.da.description": "ARTIK_REF_17K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "WiFi Module",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "011120190711",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Micom",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "2103120d,ffffffff",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/mode/0",
"rep": {
"supportedModes": [
"HOMECARE_WIZARD_V2",
"ENERGY_REPORT_MODEL",
"18K_REF_OUTDOOR_CONTROL_V2"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2",
"ENERGY_REPORT_MODEL",
"18K_REF_OUTDOOR_CONTROL_V2"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "Micom",
"x.com.samsung.da.newVersionAvailable": "false"
}
},
{
"href": "/refrigeration/0",
"rep": {
"defrost": false,
"rapidFreeze": false,
"rapidCool": false
}
},
{
"href": "/refrigeration/vs/0",
"rep": {
"x.com.samsung.da.rapidFreezing": "Off"
}
},
{
"href": "/sabbath/vs/0",
"rep": {}
},
{
"href": "/temperature/current/freezer/0",
"rep": {
"range": [
-23.0,
-15.0
],
"units": "C",
"temperature": -20.0
}
},
{
"href": "/temperature/desired/freezer/0",
"rep": {
"range": [
-23.0,
-15.0
],
"units": "C",
"temperature": -20.0
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Freezer",
"x.com.samsung.da.desired": "-20",
"x.com.samsung.da.current": "-20",
"x.com.samsung.da.maximum": "-15",
"x.com.samsung.da.minimum": "-23",
"x.com.samsung.da.unit": "Celsius"
}
]
}
}
]
}
@@ -0,0 +1,274 @@
{
"device0": [
{
"rt": ["x.com.samsung.devcol", "oic.wk.col"],
"if": ["oic.if.baseline", "oic.if.ll", "oic.if.b"]
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativeConsumption": "5",
"x.com.samsung.da.cumulativePower": "1733313",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPower": "61",
"x.com.samsung.da.instantaneousPowerUnit": "W"
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2",
"ENERGY_REPORT_MODEL",
"18K_KIMCHI_OUTDOOR_CONTROL"
],
"x.com.samsung.da.modes": [
"KIMCHIT_STORAGE_FREEZER_NORMAL",
"KIMCHIT_RIPE_REMAIN_[0]:[0]",
"KIMCHIM_KIMCHI_STORAGE_NORMAL",
"KIMCHIM_RIPE_REMAIN_[0]:[0]",
"KIMCHIB_KIMCHI_STORAGE_NORMAL",
"KIMCHIB_RIPE_REMAIN_[0]:[0]",
"KIMCHIT_BOX_COUNT_[6]",
"KIMCHIM_BOX_COUNT_[4]",
"KIMCHIB_BOX_COUNT_[2]",
"KIMCHI_BOX_COUNT_[0]"
],
"x.com.samsung.da.supportedOptions": [
"KIMCHIT_KIMCHI_STORAGE_NORMAL_[0]:[0]",
"KIMCHIT_KIMCHI_STORAGE_COLD_[0]:[0]",
"KIMCHIT_KIMCHI_STORAGE_WARM_[0]:[0]",
"KIMCHIT_KIMCHI_STORAGE_LOW_SALT_NORMAL_[0]:[0]",
"KIMCHIT_KIMCHI_STORAGE_LOW_SALT_COLD_[0]:[0]",
"KIMCHIT_KIMCHI_STORAGE_LOW_SALT_WARM_[0]:[0]",
"KIMCHIT_STORAGE_FRIDGE_NORMAL_[0]:[0]",
"KIMCHIT_STORAGE_FRIDGE_COLD_[0]:[0]",
"KIMCHIT_STORAGE_FRIDGE_WARM_[0]:[0]",
"KIMCHIT_STORAGE_FREEZER_NORMAL_[0]:[0]",
"KIMCHIT_STORAGE_FREEZER_COLD_[0]:[0]",
"KIMCHIT_STORAGE_FREEZER_WARM_[0]:[0]",
"KIMCHIT_OFF_[0]:[0]",
"KIMCHIT_KIMCHI_RIPE_LOW_TEMP_[5]:[17]",
"KIMCHIT_KIMCHI_RIPE_NORMAL_TEMP_[2]:[12]",
"KIMCHIM_KIMCHI_STORAGE_NORMAL_[0]:[0]",
"KIMCHIM_KIMCHI_STORAGE_COLD_[0]:[0]",
"KIMCHIM_KIMCHI_STORAGE_WARM_[0]:[0]",
"KIMCHIM_KIMCHI_STORAGE_LOW_SALT_NORMAL_[0]:[0]",
"KIMCHIM_KIMCHI_STORAGE_LOW_SALT_COLD_[0]:[0]",
"KIMCHIM_KIMCHI_STORAGE_LOW_SALT_WARM_[0]:[0]",
"KIMCHIM_KIMCHI_STORAGE_CRUNFCH_[0]:[0]",
"KIMCHIM_KIMCHI_STORAGE_BUY_[0]:[0]",
"KIMCHIM_MEAT_RIPE_NORMAL_[3]:[0]",
"KIMCHIM_STORAGE_MEAT_[0]:[0]",
"KIMCHIM_STORAGE_FRIDGE_VEGETABLES_FRUIT_[0]:[0]",
"KIMCHIM_STORAGE_FRESH_CEREAL_[0]:[0]",
"KIMCHIM_OFF_[0]:[0]",
"KIMCHIM_KIMCHI_RIPE_LOW_TEMP_[5]:[17]",
"KIMCHIM_KIMCHI_RIPE_NORMAL_TEMP_[2]:[12]",
"KIMCHIB_KIMCHI_STORAGE_NORMAL_[0]:[0]",
"KIMCHIB_KIMCHI_STORAGE_COLD_[0]:[0]",
"KIMCHIB_KIMCHI_STORAGE_WARM_[0]:[0]",
"KIMCHIB_KIMCHI_STORAGE_LOW_SALT_NORMAL_[0]:[0]",
"KIMCHIB_KIMCHI_STORAGE_LOW_SALT_COLD_[0]:[0]",
"KIMCHIB_KIMCHI_STORAGE_LOW_SALT_WARM_[0]:[0]",
"KIMCHIB_KIMCHI_STORAGE_CRUNFCH_[0]:[0]",
"KIMCHIB_KIMCHI_STORAGE_BUY_[0]:[0]",
"KIMCHIB_STORAGE_FRIDGE_VEGETABLES_FRUIT_[0]:[0]",
"KIMCHIB_STORAGE_FRIDGE_DRINK_[0]:[0]",
"KIMCHIB_STORAGE_FRESH_WINE_[0]:[0]",
"KIMCHIB_STORAGE_FRESH_POTATO_BANANA_[0]:[0]",
"KIMCHIB_OFF_[0]:[0]",
"KIMCHIB_KIMCHI_RIPE_KKAKDUGI_[4]:[5]",
"KIMCHIB_KIMCHI_RIPE_DONGCHIMI_[7]:[6]"
]
}
},
{
"href": "/mode/0",
"rep": {
"supportedModes": [
"HOMECARE_WIZARD_V2",
"ENERGY_REPORT_MODEL",
"18K_KIMCHI_OUTDOOR_CONTROL"
],
"modes": [
"KIMCHIT_STORAGE_FREEZER_NORMAL",
"KIMCHIT_RIPE_REMAIN_[0]:[0]",
"KIMCHIM_KIMCHI_STORAGE_NORMAL",
"KIMCHIM_RIPE_REMAIN_[0]:[0]",
"KIMCHIB_KIMCHI_STORAGE_NORMAL",
"KIMCHIB_RIPE_REMAIN_[0]:[0]",
"KIMCHIT_BOX_COUNT_[6]",
"KIMCHIM_BOX_COUNT_[4]",
"KIMCHIB_BOX_COUNT_[2]",
"KIMCHI_BOX_COUNT_[0]"
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP2X_REF_20K|00135941|10010221011411010103642021000000",
"x.com.samsung.da.description": "TP2X_REF_20K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "WiFi Module",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02144A220110",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Micom",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "20082109,FFFFFFFF",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/doors/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Door",
"x.com.samsung.da.openState": "Close"
}
]
}
},
{
"href": "/kimchidoors/top/vs/0",
"rep": {
"x.com.samsung.da.openState": "Close"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.countryCode": "",
"x.com.samsung.da.region": ""
}
},
{
"href": "/bespoke/vs/0",
"rep": {
"x.com.samsung.da.BespokeProduct": "On"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "Micom",
"x.com.samsung.da.newVersionAvailable": "false"
}
},
{
"href": "/status/kimchi/top/vs/0",
"rep": {
"x.com.samsung.da.currentMode": "STORAGE_FREEZER_NORMAL",
"x.com.samsung.da.ripeStatus": "Off",
"x.com.samsung.da.ripeRemaintime": "0",
"x.com.samsung.da.rackCount": "6",
"x.com.samsung.da.supportMode": [
"KIMCHI_STORAGE_NORMAL",
"KIMCHI_STORAGE_COLD",
"KIMCHI_STORAGE_WARM",
"KIMCHI_STORAGE_LOW_SALT_NORMAL",
"KIMCHI_STORAGE_LOW_SALT_COLD",
"KIMCHI_STORAGE_LOW_SALT_WARM",
"STORAGE_FRIDGE_NORMAL",
"STORAGE_FRIDGE_COLD",
"STORAGE_FRIDGE_WARM",
"STORAGE_FREEZER_NORMAL",
"STORAGE_FREEZER_COLD",
"STORAGE_FREEZER_WARM",
"OFF",
"KIMCHI_RIPE_LOW_TEMP",
"KIMCHI_RIPE_NORMAL_TEMP"
]
}
},
{
"href": "/status/kimchi/middle/vs/0",
"rep": {
"x.com.samsung.da.currentMode": "KIMCHI_STORAGE_NORMAL",
"x.com.samsung.da.ripeStatus": "Off",
"x.com.samsung.da.ripeRemaintime": "0",
"x.com.samsung.da.rackCount": "4",
"x.com.samsung.da.supportMode": [
"KIMCHI_STORAGE_NORMAL",
"KIMCHI_STORAGE_COLD",
"KIMCHI_STORAGE_WARM",
"KIMCHI_STORAGE_LOW_SALT_NORMAL",
"KIMCHI_STORAGE_LOW_SALT_COLD",
"KIMCHI_STORAGE_LOW_SALT_WARM",
"KIMCHI_STORAGE_CRUNFCH",
"KIMCHI_STORAGE_BUY",
"MEAT_RIPE_NORMAL",
"STORAGE_MEAT",
"STORAGE_FRIDGE_VEGETABLES_FRUIT",
"STORAGE_FRESH_CEREAL",
"OFF",
"KIMCHI_RIPE_LOW_TEMP",
"KIMCHI_RIPE_NORMAL_TEMP"
]
}
},
{
"href": "/status/kimchi/bottom/vs/0",
"rep": {
"x.com.samsung.da.currentMode": "KIMCHI_STORAGE_NORMAL",
"x.com.samsung.da.ripeStatus": "Off",
"x.com.samsung.da.ripeRemaintime": "0",
"x.com.samsung.da.rackCount": "2",
"x.com.samsung.da.supportMode": [
"KIMCHI_STORAGE_NORMAL",
"KIMCHI_STORAGE_COLD",
"KIMCHI_STORAGE_WARM",
"KIMCHI_STORAGE_LOW_SALT_NORMAL",
"KIMCHI_STORAGE_LOW_SALT_COLD",
"KIMCHI_STORAGE_LOW_SALT_WARM",
"KIMCHI_STORAGE_CRUNFCH",
"KIMCHI_STORAGE_BUY",
"STORAGE_FRIDGE_VEGETABLES_FRUIT",
"STORAGE_FRIDGE_DRINK",
"STORAGE_FRESH_WINE",
"STORAGE_FRESH_POTATO_BANANA",
"OFF",
"KIMCHI_RIPE_KKAKDUGI",
"KIMCHI_RIPE_DONGCHIMI"
]
}
}
]
}
+170
View File
@@ -0,0 +1,170 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.timeforlongnoti": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativePower": "915",
"x.com.samsung.da.cumulativeUnit": "Wh"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "A-VSKR-TP1-22-VS9500AL|50023541|80030100001611000800000000000000",
"x.com.samsung.da.description": "A-VSKR-TP1-22-VS9500AL",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "VS1",
"x.com.samsung.da.diagMinVersion": "1.0",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "023741250507",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "25050800",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "2650000000",
"x.com.samsung.da.airconOptionList": [
"HOMECARE_WIZARD_V2",
"CLEAN_OPTION_SUPPORT"
]
}
},
{
"href": "/component/station/dustbag/vs/0",
"rep": {
"x.com.samsung.da.status": "normal",
"x.com.samsung.da.supportedStatus": [
"full",
"normal"
]
}
},
{
"href": "/setting/dustbin/vs/0",
"rep": {
"x.com.samsung.da.autoEmpty": "On",
"x.com.samsung.da.autoClose": "On",
"x.com.samsung.da.desiredDischargingTime": "3",
"x.com.samsung.da.supportedDischargingTime": [
"1",
"3"
]
}
},
{
"href": "/status/cleanstation/vs/0",
"rep": {
"x.com.samsung.da.status": "Ready",
"x.com.samsung.da.uvcTotalOperationTime": "90",
"x.com.samsung.da.uvcOperationTime": "90",
"x.com.samsung.da.uvcFinishedTime": "2026-07-27T10:26Z",
"x.com.samsung.da.emittedTime": "2026-07-26T12:26Z",
"x.com.samsung.da.uvcIntensive": "Off",
"x.com.samsung.da.stickStatus": "On"
}
},
{
"href": "/component/station/dustbagusage/vs/0",
"rep": {
"x.com.samsung.da.dustbagUsage": "506",
"x.com.samsung.da.dustbagPrevUsage": "0"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"flashingProgress": ""
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
]
}
}
]
}
+407
View File
@@ -0,0 +1,407 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "-500",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePower": "40500",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.cumulativeDate": "1784988000",
"x.com.samsung.da.cumulativeDateUTC": "1785013200"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/course/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.options": [
"DeviceType_0145",
"UpdateAllow_NotAllowed",
"Course_01",
"LaundryOutTime_0",
"AddGarmentIndicator_Off",
"SeamlessControl_Disable",
"KidsLockBypass_On",
"WashingTimes_18",
"DrumCleanProposal_20",
"DetergentOnce_0",
"DetergentLeft_0",
"DetergentBase_0",
"DetergentAlarm_Off",
"DetergentType_0",
"DetergentTotal_0",
"SoftenerOnce_0",
"SoftenerLeft_0",
"SoftenerBase_0",
"SoftenerAlarm_Off",
"SoftenerType_0",
"SoftenerTotal_0",
"SpecialFunction_6",
"AvailableDelayTime_67",
"DetergentLevelCtrl_0",
"SoftenerLevelCtrl_3",
"SupportedDetergentLevelCtrl_00010203",
"SupportedSoftenerLevelCtrl_00010203",
"DetergentLevel2Ctrl_1",
"SoftenerLevel2Ctrl_1",
"SupportedDetergentLevel2Ctrl_010203",
"SupportedSoftenerLevel2Ctrl_010203",
"LaundryPlannerUserSetTime_0",
"ProgressTimeSet_4205DC8208E8A206AE",
"SuperSpeed_Off",
"SendToDevice_Off",
"DetergentCycleUsed_0",
"SoftenerCycleUsed_0",
"CloudCourse_001C590549164D114A224C2037F0AC22",
"CloudExtraCourse_5958",
"OneTimeCloudCourse_FFFF010049004D004A804C0037F0AC00",
"EnergyLevelSet_05020403040204040401030203",
"MostUsed_01843E913FA43BC33E",
"SuperSpeedSet_F0F000F00000000000000000",
"DispenserSet_22222222222222FFF2000022",
"GeoFenceAlarm",
"UsagesDB_ok",
"EnergyKW_396",
"DrumCleanLog_2025-09-07T18:15:52|2025-10-05T18:49:21|2025-11-23T18:20:07|2026-01-01T19:11:59|2026-02-15T03:36:21|2026-03-09T19:59:19|2026-04-19T21:35:33|2026-05-10T19:21:00|2026-06-12T21:32:16|2026-06-29T06:29:50",
"TimeSync_NotSupported"
],
"x.com.samsung.da.supportedOptions": [
"401843E913FA43BC33E53853E913FA43FC53E86843E913FA43FC33E7C853E923FA43FC53E65821E913FA43FC33E7D843E923FA31FC33E1783089102A410C3087E85209204A308C0005E8000913FA43FC00055831E913FA31FC20E57821E913FA20FC10204843E913FA43FC13E"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/cycleinterface/vs/0",
"rep": {}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/kidslock/0",
"rep": {
"value": false
}
},
{
"href": "/operational/state/vs/0",
"rep": {
"x.com.samsung.da.state": "Ready",
"x.com.samsung.da.remainingTime": "01:07:00",
"x.com.samsung.da.progressPercentage": "1",
"x.com.samsung.da.progress": "None",
"x.com.samsung.da.delayEndTime": "00:00:00",
"x.com.samsung.da.supportedProgress": [
"None",
"Weightsensing",
"Wash",
"Rinse",
"Spin",
"Finish"
]
}
},
{
"href": "/operational/state/0",
"rep": {
"currentMachineState": "**REDACTED**",
"machineStates": "**REDACTED**",
"jobStates": [
"None",
"Weightsensing",
"Wash",
"Rinse",
"Spin",
"Finish"
],
"currentJobState": "None",
"remainingTime": "01:07:00",
"progressPercentage": "1"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "DA_WM_TP1_21_COMMON|20233742|20000001001511200AAB020200000000",
"x.com.samsung.da.description": "DA_WM_TP1_21_COMMON_WA7700A/DC92-03005B_004A",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "210",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "DA_WM_TP1_21_COMMON|20233742|20000001001511200AAB020200000000",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02986A260118(A182)",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Firmware_1_DB_20233742210931500FFFFF203005422212139101FFFF(01452023374220300542_30221213)(FileDown:0)(Type:0)",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "02337B21093150,03005B22121391",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Firmware_2_DB_2023394522081051012FFFFFFFFFFFFFFFFFFFFFFFFE(014520233945FFFFFFFF_30000000)(FileDown:0)(Type:0)",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "02339E22081051,FFFFFFFFFFFFFF"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "-07:00"
}
},
{
"href": "/washer/vs/0",
"rep": {
"x.com.samsung.da.detergentLevel": "1",
"x.com.samsung.da.softenerLevel": "2",
"x.com.samsung.da.waterTemperature": "Warm",
"x.com.samsung.da.supportedWaterTemperature": [
"None",
"Cold",
"Cool",
"EcoWarm",
"Warm",
"Hot"
],
"x.com.samsung.da.spinLevel": "High",
"x.com.samsung.da.supportedSpinLevel": [
"RinseHold",
"NoSpin",
"Low",
"Medium",
"High",
"ExtraHigh"
],
"x.com.samsung.da.soilLevel": "Normal",
"x.com.samsung.da.supportedSoilLevel": [
"None",
"ExtraLight",
"Light",
"Normal",
"Heavy",
"ExtraHeavy"
],
"x.com.samsung.da.rinseCycles": "1",
"x.com.samsung.da.supportedRinseCycles": [
"0",
"1",
"2",
"3",
"4",
"5"
]
}
},
{
"href": "/st/washercourse/vs/0",
"rep": {
"x.com.samsung.da.st.washerMode": "Table_02_Course_01",
"x.com.samsung.da.st.courseTable": "Table_02"
}
},
{
"href": "/setting/vs/0",
"rep": {}
},
{
"href": "/wm/editcourse/vs/0",
"rep": {}
},
{
"href": "/wm/setinfo/vs/0",
"rep": {
"x.com.samsung.da.isModelSettingWithoutSC": "true",
"x.com.samsung.da.isModelSettingPowerOnOff": "false",
"x.com.samsung.da.modelCode": "M(None),W(WA55A7700AV/US)"
}
},
{
"href": "/wm/jobbeginingstatus/vs/0",
"rep": {
"x.com.samsung.da.currentStatus": "None"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "2026-03-04",
"otnList": [
{
"type": "WIFI",
"modelId": "DA_WM_TP1_21_COMMON",
"versions": [
"30260118"
],
"visVersion": "260118"
},
{
"type": "Micom",
"modelId": "01452023374220300542",
"versions": [
"21093150",
"22121391"
],
"visVersion": "221213"
},
{
"type": "Micom",
"modelId": "014520233945FFFFFFFF",
"versions": [
"22081051",
"FFFFFFFF"
],
"visVersion": "220810"
}
]
}
},
{
"href": "/remotectrl/vs/0",
"rep": {
"x.com.samsung.da.remoteControlEnabled": "false"
}
},
{
"href": "/remotectrl/0",
"rep": {
"value": false
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.countryCode": "US"
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "America/Phoenix",
"offset": "-07:00",
"DST": "OFF"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
}
]
}
+314
View File
@@ -0,0 +1,314 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "-500",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePower": "121100",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.cumulativeDate": "1785142800",
"x.com.samsung.da.cumulativeDateUTC": "1785110400"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/course/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.options": [
"DeviceType_015C",
"UpdateAllow_NotAllowed",
"Course_01",
"LaundryOutTime_0",
"SeamlessControl_Enable",
"KidsLockBypass_On",
"FreezeProtectionAlarm_On",
"WashingTimes_19",
"DrumCleanProposal_20",
"DrumCleanLog_2026-02-04T04:05:54|2026-02-28T08:48:43|2026-03-16T03:15:29|2026-03-26T02:55:05|2026-04-15T05:57:11|2026-04-30T05:37:44|2026-05-14T05:29:20|2026-06-04T01:55:39|2026-06-25T05:21:23|2026-07-11T03:10:21",
"DetergentOnce_0",
"DetergentLeft_0",
"DetergentBase_0",
"DetergentAlarm_Off",
"DetergentType_0",
"DetergentTotal_0",
"SoftenerOnce_0",
"SoftenerLeft_0",
"SoftenerBase_0",
"SoftenerAlarm_Off",
"SoftenerType_0",
"SoftenerTotal_0",
"SpecialFunction_4",
"AvailableDelayTime_73",
"LaundryPlannerUserSetTime_0",
"ProgressTimeSet_420780820438A205BE",
"FreezeProtectionMode_Off",
"SendToDevice_Off",
"EnergyLevelSet_0503030303040304010505020204",
"MostUsed_01923FA33F510E60A17340",
"GeoFenceAlarm",
"UsagesDB_ok",
"EnergyKW_396",
"DrumCleanLog_2026-02-04T04:05:54|2026-02-28T08:48:43|2026-03-16T03:15:29|2026-03-26T02:55:05|2026-04-15T05:57:11|2026-04-30T05:37:44|2026-05-14T05:29:20|2026-06-04T01:55:39|2026-06-25T05:21:23|2026-07-11T03:10:21",
"TimeSync_NotSupported"
],
"x.com.samsung.da.supportedOptions": [
"501923FA33F510E60A1734050923FA33F510E60A173400F933FA33F510E60A173407B923FA31F520E60A1724006933FA31F510E68A172400C933FA31F520E60A172404F9204A41052046666733308913FA33F510E60A170004A923FA31F520C645175554B923FA31F520C64517555269204A102510664A171114C913FA31F510E624171404D9204A410520466667555"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/cycleinterface/vs/0",
"rep": {}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/kidslock/0",
"rep": {
"value": false
}
},
{
"href": "/operational/state/vs/0",
"rep": {
"x.com.samsung.da.state": "Ready",
"x.com.samsung.da.remainingTime": "01:13:00",
"x.com.samsung.da.progressPercentage": "1",
"x.com.samsung.da.progress": "None",
"x.com.samsung.da.delayEndTime": "00:00:00",
"x.com.samsung.da.supportedProgress": [
"None",
"Weightsensing",
"Wash",
"Rinse",
"Spin",
"Finish"
]
}
},
{
"href": "/operational/state/0",
"rep": {
"currentMachineState": "**REDACTED**",
"machineStates": "**REDACTED**",
"jobStates": [
"None",
"Weightsensing",
"Wash",
"Rinse",
"Spin",
"Finish"
],
"currentJobState": "None",
"remainingTime": "01:13:00",
"progressPercentage": "1"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "DA_WM_TP2_20_COMMON|20233741|200000010014110002A3020200000000",
"x.com.samsung.da.description": "DA_WM_TP2_20_COMMON_WA8000T/DC92-02810A_0002",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "210",
"x.com.samsung.da.diagMinVersion": "1.0",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "DA_WM_TP2_20_COMMON|20233741|200000010014110002A3020200000000",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02674A250414(F546)",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Firmware_1_DB_20233741181128160FFFFF202810412011303403FFFF(015C2023374120281041_30000000)(FileDown:0)(Type:0)",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "18112816,20113034",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Firmware_2_DB_2023394400000000032FFFFFFFFFFFFFFFFFFFFFFFFE(015C20233944FFFFFFFF_30000000)(FileDown:0)(Type:0)",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "00000000,FFFFFFFF"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00"
}
},
{
"href": "/washer/vs/0",
"rep": {
"x.com.samsung.da.spinLevel": "Medium",
"x.com.samsung.da.supportedSpinLevel": [
"NoSpin",
"Delicate",
"Low",
"Medium",
"High",
"ExtraHigh"
],
"x.com.samsung.da.rinseCycles": "2",
"x.com.samsung.da.supportedRinseCycles": [
"0",
"1",
"2",
"3",
"4",
"5"
],
"x.com.samsung.da.waterValve": "Cold",
"x.com.samsung.da.supportedWaterValve": [
"None",
"Cold",
"Warm",
"Hot"
],
"x.com.samsung.da.waterHeight": "0",
"x.com.samsung.da.supportedWaterHeight": [
"0",
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"NoDisplay"
],
"x.com.samsung.da.washTime": "21",
"x.com.samsung.da.supportedWashTime": [
"0",
"9",
"15",
"21",
"27",
"50+"
]
}
},
{
"href": "/st/washercourse/vs/0",
"rep": {
"x.com.samsung.da.st.washerMode": "Table_02_Course_01",
"x.com.samsung.da.st.courseTable": "Table_02"
}
},
{
"href": "/setting/vs/0",
"rep": {}
},
{
"href": "/wm/editcourse/vs/0",
"rep": {}
},
{
"href": "/wm/setinfo/vs/0",
"rep": {
"x.com.samsung.da.isModelSettingWithoutSC": "true",
"x.com.samsung.da.isModelSettingPowerOnOff": "false"
}
},
{
"href": "/wm/jobbeginingstatus/vs/0",
"rep": {
"x.com.samsung.da.currentStatus": "None"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "Micom",
"x.com.samsung.da.newVersionAvailable": "false"
}
},
{
"href": "/remotectrl/vs/0",
"rep": {
"x.com.samsung.da.remoteControlEnabled": "false"
}
},
{
"href": "/remotectrl/0",
"rep": {
"value": false
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "4137000000",
"x.com.samsung.da.countryCode": "KR"
}
}
]
}
+295
View File
@@ -0,0 +1,295 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/selfcheck/vs/0",
"rep": {
"x.com.samsung.da.status": "Ready",
"x.com.samsung.da.result": "Success",
"x.com.samsung.da.error": [
"DA_ERROR_NONE"
],
"x.com.samsung.da.supportedActions": [
"Start"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.modes": [
"WATERFILTER_DISABLE"
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP2X_WATERPURIFIER_20K|00156641|900000000216130001088700000E0000",
"x.com.samsung.da.description": "TP2X_WATERPURIFIER_20K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "RP0",
"x.com.samsung.da.diagMinVersion": "1.0",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "WiFi Module",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02144A240904",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Micom",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "24091109, 2409110D, 22092302, FFFFFFFF, 23030200, FFFFFFFF",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+00:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"otnStatus": "None",
"flashingProgress": "",
"otnList": [
{
"type": "WIFI",
"modelId": "A-WPWW-TP2-22-COMMON",
"versions": [
"20240904"
],
"visVersion": "240904"
},
{
"type": "Micom",
"modelId": "03800015664100156041",
"versions": [
"24091109",
"2409110D"
],
"visVersion": "240911"
},
{
"type": "Micom",
"modelId": "038000156141FFFFFFFF",
"versions": [
"22092302",
"FFFFFFFF"
],
"visVersion": "220923"
},
{
"type": "Micom",
"modelId": "038000159141FFFFFFFF",
"versions": [
"23030200",
"FFFFFFFF"
],
"visVersion": "230302"
}
]
}
},
{
"href": "/filter/waterfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "90",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.lastResetDate": "2025-08-29T03:22:31",
"x.com.samsung.da.filterResetType": [
"replaceable"
]
}
},
{
"href": "/status/lock/vs/0",
"rep": {
"x.com.samsung.da.coldwaterLock": "Unlocked",
"x.com.samsung.da.buzzLock": "Unlocked"
}
},
{
"href": "/setting/waterpurifier/vs/0",
"rep": {
"x.com.samsung.da.hotwaterLevel": "5",
"x.com.samsung.da.desiredType": "ambientwater",
"x.com.samsung.da.tempDesiredHotWater": "40",
"x.com.samsung.da.tempUnit": "C",
"x.com.samsung.da.desiredCapacity": "100",
"x.com.samsung.da.capacityUnit": "C",
"x.com.samsung.da.capacityResolution": "10",
"x.com.samsung.da.hotwaterRange": [
"40",
"90"
],
"x.com.samsung.da.desiredCapacityRange": [
"50",
"2000"
],
"x.com.samsung.da.supportedTypes": [
"ambientwater",
"coldwater",
"hotwater"
],
"x.com.samsung.da.pourStatus": "Off"
}
},
{
"href": "/status/waterpurifier/vs/0",
"rep": {
"x.com.samsung.da.status": "Ready",
"x.com.samsung.da.filterDoorStatus": "Close",
"x.com.samsung.da.sterilizeRunTime": "0",
"x.com.samsung.da.sterilizeStartTime": "2026-07-27T17:00:00",
"x.com.samsung.da.sterilizePeriod": "3",
"x.com.samsung.da.sterilizePlanTime": "2026-07-27T17:00:00",
"x.com.samsung.da.sterilizeLastTime": "2026-07-24T17:08:25",
"x.com.samsung.da.sterilizeMaxTime": "10",
"x.com.samsung.da.filterCleanRemainTime": "0",
"x.com.samsung.da.filterCleanMaxTime": "14"
}
},
{
"href": "/favorite/capacity/vs/0",
"rep": {
"x.com.samsung.da.switchCapacity": "On",
"x.com.samsung.da.defaultCapacity": "100",
"x.com.samsung.da.capacityList": [
"100",
"200",
"260",
"500",
"9999"
]
}
},
{
"href": "/favorite/hotwater/vs/0",
"rep": {
"x.com.samsung.da.switchHotwater": "Unlocked",
"x.com.samsung.da.favorite.defaultTemperature": "40",
"x.com.samsung.da.favorite.revision": "0",
"x.com.samsung.da.favorite.showList": [
"40",
"75",
"85",
"90"
],
"x.com.samsung.da.favorite.supportedList": [
"40",
"75",
"85",
"90"
]
}
},
{
"href": "/automation/waterpurifier/vs/0",
"rep": {
"automation.supported.modes": [
"0"
],
"automation.supported.options": [
"capacity"
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/recipe/coffee/vs/0",
"rep": {
"publisher.support": [
"1",
"2",
"3",
"4",
"5"
]
}
},
{
"href": "/coffee/custom/recipe/vs/0",
"rep": {
"publisher.support": [
"1",
"2",
"3",
"4",
"5"
]
}
},
{
"href": "/favorite/coffee/vs/0",
"rep": {
"favorite.activate": "On",
"brew.status": "Suspend",
"favorite.enable.list": [
"0",
"1",
"2"
]
}
},
{
"href": "/recipe/coffee/deletion/vs/0",
"rep": {}
},
{
"href": "/brand/recipe/info/vs/0",
"rep": {
"revision": "0",
"brand.num.max": "1"
}
}
]
}
+234
View File
@@ -0,0 +1,234 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/selfcheck/vs/0",
"rep": {
"x.com.samsung.da.status": "Ready",
"x.com.samsung.da.result": "Success",
"x.com.samsung.da.error": [
"DA_ERROR_NONE"
],
"x.com.samsung.da.supportedActions": [
"Start"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.modes": [
"WATERFILTER_DISABLE"
]
}
},
{
"href": "/mode/0",
"rep": {
"supportedModes": [
"HOMECARE_WIZARD_V2"
],
"modes": [
"WATERFILTER_DISABLE"
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP2X_WATERPURIFIER_20K|00132341|900000000215130001060F0000020000",
"x.com.samsung.da.description": "TP2X_WATERPURIFIER_20K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "540",
"x.com.samsung.da.diagMinVersion": "1.0",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "WiFi Module",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02144A240615",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Micom",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "24061111, 24091218, 21072807, FFFFFFFF",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"otnStatus": "None",
"flashingProgress": "",
"otnList": [
{
"type": "WIFI",
"modelId": "A-WPWW-TP2-20-COMMON",
"versions": [
"20240615"
],
"visVersion": "240615"
},
{
"type": "Micom",
"modelId": "03800013234100132441",
"versions": [
"24061111",
"24091218"
],
"visVersion": "240912"
},
{
"type": "Micom",
"modelId": "038000132541FFFFFFFF",
"versions": [
"21072807",
"FFFFFFFF"
],
"visVersion": "210728"
}
]
}
},
{
"href": "/filter/waterfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "28",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.lastResetDate": "2026-04-14T14:33:15",
"x.com.samsung.da.filterResetType": [
"replaceable"
]
}
},
{
"href": "/status/lock/vs/0",
"rep": {
"x.com.samsung.da.hotwaterLock": "Unlocked",
"x.com.samsung.da.coldwaterLock": "Unlocked",
"x.com.samsung.da.buzzLock": "Unlocked"
}
},
{
"href": "/setting/waterpurifier/vs/0",
"rep": {
"x.com.samsung.da.desiredType": "coldwater",
"x.com.samsung.da.tempDesiredHotWater": "85",
"x.com.samsung.da.tempUnit": "C",
"x.com.samsung.da.desiredCapacity": "100",
"x.com.samsung.da.capacityUnit": "C",
"x.com.samsung.da.capacityResolution": "10",
"x.com.samsung.da.desiredCapacityRange": [
"50",
"2000"
],
"x.com.samsung.da.supportedTypes": [
"ambientwater",
"coldwater",
"hotwater"
],
"x.com.samsung.da.supportedHotTemperatures": [
"40",
"75",
"85"
],
"x.com.samsung.da.triggerTime": "1785063153",
"x.com.samsung.da.pourStatus": "Off"
}
},
{
"href": "/status/waterpurifier/vs/0",
"rep": {
"x.com.samsung.da.status": "Ready",
"x.com.samsung.da.filterDoorStatus": "Close",
"x.com.samsung.da.sterilizeRunTime": "0",
"x.com.samsung.da.sterilizeStartTime": "2026-07-27T18:00:00",
"x.com.samsung.da.sterilizePeriod": "3",
"x.com.samsung.da.sterilizePlanTime": "2026-07-27T18:00:00",
"x.com.samsung.da.sterilizeLastTime": "2026-07-24T18:09:25",
"x.com.samsung.da.sterilizeMaxTime": "10",
"x.com.samsung.da.filterCleanRemainTime": "0",
"x.com.samsung.da.filterCleanMaxTime": "15"
}
},
{
"href": "/favorite/capacity/vs/0",
"rep": {
"x.com.samsung.da.switchCapacity": "On",
"x.com.samsung.da.defaultCapacity": "100",
"x.com.samsung.da.maxCapacity": "6",
"x.com.samsung.da.capacityList": [
"100",
"150",
"200",
"250",
"550",
"9999"
]
}
},
{
"href": "/automation/waterpurifier/vs/0",
"rep": {
"automation.supported.modes": [
"0"
],
"automation.supported.options": [
"capacity"
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
}
]
}
+16
View File
@@ -508,3 +508,19 @@ async def test_options_flow_finish_preserves_existing_options(
assert result['type'] == FlowResultType.CREATE_ENTRY
assert entry.options[CONF_BYPASS_REMOTE_CONTROL] is True
def test_is_placeholder_serial_catches_nothing_svc():
"""Issue #83: the ARTIK051_DONGLE_REF firmware family reports the
literal string 'Nothing(SVC)' as serialNum on every unit -- non-empty,
so it must be caught by name, not by the plain `if not serial` check."""
from custom_components.localthings.config_flow import _is_placeholder_serial
assert _is_placeholder_serial('Nothing(SVC)') is True
assert _is_placeholder_serial('nothing(svc)') is True
assert _is_placeholder_serial(' Nothing(SVC) ') is True
def test_is_placeholder_serial_accepts_real_serials():
from custom_components.localthings.config_flow import _is_placeholder_serial
assert _is_placeholder_serial('0A1B2C3D4E5F') is False
assert _is_placeholder_serial('') is False
+190 -8
View File
@@ -11,11 +11,15 @@ from homeassistant.exceptions import ServiceValidationError
from homeassistant.helpers import issue_registry as ir
from custom_components.localthings.const import (
CONF_BYPASS_REMOTE_CONTROL, CONF_HOST, DOMAIN, SUMMARY_INTERVAL_S,
CONF_BYPASS_REMOTE_CONTROL, CONF_HOST, DOMAIN, DTLS_LOCAL_PORT_BASE,
SUMMARY_INTERVAL_S,
)
from custom_components.localthings.coordinator import (
LocalThingsCoordinator, _local_source_port,
)
from custom_components.localthings.coordinator import LocalThingsCoordinator
from custom_components.localthings.registry.capabilities.common import (
remote_control_enabled,
remote_control_required_for_write,
)
from custom_components.localthings.observe import MODE_OBSERVE, MODE_POLL, PUSH_HEALTH_WINDOW_S
@@ -136,6 +140,29 @@ def test_run_discovery_detects_washer_via_model_fallback(
assert coordinator.device_type_name == 'washer'
def test_run_discovery_falls_back_to_host_for_placeholder_serial(
hass: HomeAssistant, mock_entry
) -> None:
"""Issue #83: the ARTIK051_DONGLE_REF firmware family reports the
literal string 'Nothing(SVC)' as serialNum on every unit. Left as-is,
two such units get the same device_serial (which feeds both the HA
device-registry identifier and every entity's unique_id), so the
second one's entities silently collide and get dropped. It must be
treated the same as an empty serial and fall back to the host."""
resources = {
'/information/vs/0': {
'x.com.samsung.da.modelNum':
'ARTIK051_DONGLE_REF|00127641|00080020001430300100000000000000',
'x.com.samsung.da.description': 'ARTIK_REF_17K',
'x.com.samsung.da.serialNum': 'Nothing(SVC)',
},
'/otninformation/vs/0': {},
}
coordinator = LocalThingsCoordinator(hass, mock_entry)
coordinator._run_discovery(resources)
assert coordinator.device_serial == mock_entry.data[CONF_HOST]
def test_run_discovery_detects_cooktop_via_resource_signature(
hass: HomeAssistant, mock_entry
) -> None:
@@ -145,7 +172,7 @@ def test_run_discovery_detects_cooktop_via_resource_signature(
coordinator = LocalThingsCoordinator(hass, mock_entry)
coordinator._run_discovery(_load_device('cooktop'))
assert coordinator.device_type_name == 'cooktop'
assert coordinator.device_type_name == 'gas_cooktop'
assert coordinator._unbound_hrefs == []
@@ -722,10 +749,10 @@ async def test_climate_power_write_applies_to_its_own_href_not_bound_href(
"""Regression for issues #17/#53, using the real AC capability. The
composite climate entity binds /mode/vs/0 (airconditioner.CLIMATE.href),
but a power command's write_fn (airconditioner._climate_write) targets
the sibling /power/0 -- the href climate.py's `_is_on()` actually reads.
the sibling /power/vs/0 -- the href climate.py's `_is_on()` actually reads.
The optimistic value and settle guard must land there, not on the bound
/mode/vs/0, or the entity never sees the write and shows stale state
until the next unrelated read of /power/0."""
until the next unrelated read of /power/vs/0."""
from custom_components.localthings.registry.capabilities import airconditioner
from custom_components.localthings.registry.discovery import BoundEntity
@@ -744,9 +771,11 @@ async def test_climate_power_write_applies_to_its_own_href_not_bound_href(
fake.post = lambda *a, **k: (0x44, b'')
await coordinator.async_send_command(bound, ('power', True))
assert coordinator._cache.get('/power/0') == {'value': True}
assert coordinator._cache.get(airconditioner.CLIMATE.href) != {'value': True}
assert coordinator._observe._settle_until.get('/power/0') is not None
assert (coordinator._cache.get('/power/vs/0') or {}).get(
'x.com.samsung.da.power') == 'On'
assert 'x.com.samsung.da.power' not in (
coordinator._cache.get(airconditioner.CLIMATE.href) or {})
assert coordinator._observe._settle_until.get('/power/vs/0') is not None
async def test_send_command_survives_stale_confirm_poll(
@@ -880,6 +909,38 @@ class TestRemoteControlEnabled:
assert remote_control_enabled({}) is True
class TestRemoteControlRequiredForWrite:
"""isModelSettingWithoutSC auto-exempts settings writes, not cycle control."""
def test_without_flag_always_requires(self):
resources = {}
assert remote_control_required_for_write(resources, '/washer/vs/0') is True
assert remote_control_required_for_write(
resources, '/operational/state/vs/0') is True
def test_without_sc_exempts_settings_keeps_operational(self):
resources = {
'/wm/setinfo/vs/0': {
'x.com.samsung.da.isModelSettingWithoutSC': 'true',
},
}
assert remote_control_required_for_write(resources, '/washer/vs/0') is False
assert remote_control_required_for_write(resources, '/course/vs/0') is False
assert remote_control_required_for_write(resources, '/buzzersound/vs/0') is False
assert remote_control_required_for_write(
resources, '/operational/state/vs/0') is True
assert remote_control_required_for_write(
resources, '/operational/state/0') is True
def test_without_sc_false_still_requires(self):
resources = {
'/wm/setinfo/vs/0': {
'x.com.samsung.da.isModelSettingWithoutSC': 'false',
},
}
assert remote_control_required_for_write(resources, '/washer/vs/0') is True
async def test_send_command_blocked_when_remote_control_disabled(
hass: HomeAssistant, mock_entry, mock_coordinator_observe_session
) -> None:
@@ -1024,3 +1085,124 @@ async def test_send_command_bypasses_remote_control_when_option_enabled(
await coordinator.async_send_command(bound, 5)
assert coordinator._cache.get('/some/path') == {'value': 5}
async def test_send_command_settings_allowed_when_without_sc(
hass: HomeAssistant, mock_entry, mock_coordinator_observe_session
) -> None:
"""Laundry boards with isModelSettingWithoutSC=true accept settings
writes while remote control is off -- no options-flow bypass needed."""
from custom_components.localthings.registry.discovery import BoundEntity
from custom_components.localthings.registry.entities import SelectDesc
fake = mock_coordinator_observe_session
await hass.config_entries.async_setup(mock_entry.entry_id)
await hass.async_block_till_done()
coordinator: LocalThingsCoordinator = hass.data[DOMAIN][mock_entry.entry_id]
coordinator._cache.apply_rep(
'/remotectrl/vs/0',
{'x.com.samsung.da.remoteControlEnabled': 'false'},
source='test',
)
coordinator._cache.apply_rep(
'/wm/setinfo/vs/0',
{'x.com.samsung.da.isModelSettingWithoutSC': 'true'},
source='test',
)
def _write_fn(payload, rep, href=None):
return (['washer', 'vs', '0'], {'x.com.samsung.da.spinLevel': payload})
desc = SelectDesc(key='spin_speed', field='x.com.samsung.da.spinLevel',
write_fn=_write_fn)
bound = BoundEntity(
href='/washer/vs/0', capability=coordinator.bound[0].capability, desc=desc,
)
with patch.object(fake, 'subscribe'):
fake.post = lambda *a, **k: (0x44, b'')
await coordinator.async_send_command(bound, '1000')
assert coordinator._cache.get('/washer/vs/0') == {
'x.com.samsung.da.spinLevel': '1000',
}
async def test_send_command_operational_still_blocked_when_without_sc(
hass: HomeAssistant, mock_entry, mock_coordinator_observe_session
) -> None:
"""Start/Pause/Stop stay gated on Smart Control even when settings
are allowed without it -- isModelSettingWithoutSC is settings-only."""
from custom_components.localthings.registry.discovery import BoundEntity
from custom_components.localthings.registry.entities import ButtonDesc
fake = mock_coordinator_observe_session
await hass.config_entries.async_setup(mock_entry.entry_id)
await hass.async_block_till_done()
coordinator: LocalThingsCoordinator = hass.data[DOMAIN][mock_entry.entry_id]
coordinator._cache.apply_rep(
'/remotectrl/vs/0',
{'x.com.samsung.da.remoteControlEnabled': 'false'},
source='test',
)
coordinator._cache.apply_rep(
'/wm/setinfo/vs/0',
{'x.com.samsung.da.isModelSettingWithoutSC': 'true'},
source='test',
)
def _write_fn(payload, rep, href=None):
return (['operational', 'state', 'vs', '0'],
{'x.com.samsung.da.state': payload})
desc = ButtonDesc(key='start', payload='Run', write_fn=_write_fn)
bound = BoundEntity(
href='/operational/state/vs/0',
capability=coordinator.bound[0].capability,
desc=desc,
)
posted = False
def _post(*a, **k):
nonlocal posted
posted = True
return (0x44, b'')
with patch.object(fake, 'subscribe'):
fake.post = _post
with pytest.raises(ServiceValidationError) as exc_info:
await coordinator.async_send_command(bound, 'Run')
assert exc_info.value.translation_domain == DOMAIN
assert exc_info.value.translation_key == 'remote_control_disabled'
assert posted is False
def test_local_source_port_stable_and_in_range() -> None:
"""Same host always maps to the same port (stability is the whole point:
a reconnect must reuse the 5-tuple), and it stays in the documented window."""
for host in ('192.168.1.217', '10.0.0.42', 'fridge.local'):
port = _local_source_port(host)
assert port == _local_source_port(host)
assert DTLS_LOCAL_PORT_BASE <= port <= DTLS_LOCAL_PORT_BASE + 0xFF
def test_local_source_port_unique_per_host_on_a_24() -> None:
"""Distinct last octets -> distinct ports, so two devices on the same HA
host never share a source port (the lib's socket is unconnected, so a
shared port would cross-deliver datagrams)."""
ports = {_local_source_port(f'192.168.1.{n}') for n in range(1, 255)}
assert len(ports) == 254
def test_local_source_port_ipv4_uses_last_octet() -> None:
"""The IPv4 fast path is the last octet, not a hash."""
assert _local_source_port('192.168.1.217') == DTLS_LOCAL_PORT_BASE + 217
def test_local_source_port_non_ipv4_falls_back_to_hash() -> None:
"""A non-IPv4 host still yields a deterministic in-range port."""
port = _local_source_port('some-hostname')
assert port == _local_source_port('some-hostname')
assert DTLS_LOCAL_PORT_BASE <= port <= DTLS_LOCAL_PORT_BASE + 0xFF
+105
View File
@@ -0,0 +1,105 @@
"""HA fan-entity mapping tests for the ARTIK051_TVTL air purifier (issue #56)."""
from custom_components.localthings.fan import LocalThingsAirflowFan
from custom_components.localthings.registry.by_type import air_purifier
from custom_components.localthings.registry.capabilities.air_purifier import HREF_AIRFLOW
from custom_components.localthings.registry.discovery import discover
from custom_components.localthings.registry.entities import FanDesc
from tests.conftest import _load_device
class _FakeCoordinator:
device_serial = 'TEST-AIRFLOW-SERIAL'
device_info = {}
data = {}
def __init__(self, resources):
self.last_resources = resources
self.commands = []
def resource(self, href):
return self.last_resources.get(href, {})
async def async_send_command(self, bound, payload):
self.commands.append((bound, payload))
def _entity(resources, coordinator=None):
bound = discover(
resources,
air_purifier.REGISTRY.capabilities,
air_purifier.REGISTRY.pattern_capabilities,
)
fan_bound = next(
item for item in bound
if isinstance(item.desc, FanDesc) and item.href == HREF_AIRFLOW
)
return LocalThingsAirflowFan(
coordinator or _FakeCoordinator(resources), fan_bound,
)
def test_power_off_maps_to_zero_percent_and_five_retained_speeds():
entity = _entity(_load_device('air_purifier'))
assert entity.is_on is False
assert entity.speed_count == 5
assert entity.percentage == 0
def test_active_codes_map_to_ordered_percentages():
"""Confirmed via issue #56's second, properly-spaced diagnostics round:
/airflow/0's speed is a clean 0-4 code across Auto/Sleep/Low/Medium/High."""
resources = _load_device('air_purifier')
resources['/power/0']['value'] = True
for code, expected_percentage in ((0, 20), (1, 40), (2, 60), (3, 80), (4, 100)):
resources['/airflow/0']['speed'] = code
assert _entity(resources).percentage == expected_percentage
async def test_power_write_prefers_standard_resource_when_both_exist():
"""Both /power/0 and /power/vs/0 are present on this family's dumps --
/power/0 must win, matching common.POWER_GENERIC's own preference (the
power_switch entity is unconditionally bound to /power/0 whenever it's
present, so writing here to /power/vs/0 first would leave the two
entities disagreeing until the next poll)."""
resources = _load_device('air_purifier')
coordinator = _FakeCoordinator(resources)
entity = _entity(resources, coordinator)
await entity.async_turn_on()
assert coordinator.commands[-1][1] == ('power', True, '/power/0')
async def test_power_write_falls_back_to_vendor_resource():
resources = _load_device('air_purifier')
resources.pop('/power/0')
coordinator = _FakeCoordinator(resources)
entity = _entity(resources, coordinator)
await entity.async_turn_off()
assert coordinator.commands[-1][1] == ('power', False, '/power/vs/0')
async def test_set_percentage_writes_raw_speed_code():
resources = _load_device('air_purifier')
resources['/power/0']['value'] = True
coordinator = _FakeCoordinator(resources)
entity = _entity(resources, coordinator)
await entity.async_set_percentage(60)
assert coordinator.commands[-1][1] == ('speed', 2)
async def test_set_percentage_zero_turns_off():
resources = _load_device('air_purifier')
resources['/power/0']['value'] = True
coordinator = _FakeCoordinator(resources)
entity = _entity(resources, coordinator)
await entity.async_set_percentage(0)
assert coordinator.commands[-1][1] == ('power', False, '/power/0')
+25 -1
View File
@@ -41,7 +41,7 @@ def test_expected_entities_present():
for key in (
'power_switch', 'alarm_code', 'dust', 'fine_dust', 'super_fine_dust',
'odor', 'clean_level', 'filter_progress', 'device_active',
'diagnosis_status', 'fan_speed_level', 'fan_direction',
'diagnosis_status', 'airflow_fan', 'fan_direction',
'display_light', 'operating_mode',
):
assert key in state, key
@@ -114,3 +114,27 @@ def test_airflow_vs_fallback_only_binds_without_generic():
{}, {'/airflow/0': {'speed': 0, 'direction': 'Off'}},
) is False
assert air_purifier.AIRFLOW_VS_FALLBACK.match_fn({}, {}) is True
def test_airflow_fan_write_contract():
"""Confirmed via issue #56's second, properly-spaced diagnostics round
(two independent units, 60-90s apart per setting): /airflow/0's `speed`
is a clean, monotonic 0-4 code, so the write is a plain int passthrough
-- no named-preset table needed (see fan.py's LocalThingsAirflowFan)."""
fan_desc = next(e for e in air_purifier.AIRFLOW_GENERIC.entities if e.key == 'airflow_fan')
assert fan_desc.write_fn(('speed', 3), {}) == (['airflow', '0'], {'speed': 3})
assert fan_desc.write_fn(('power', True, '/power/vs/0'), {}) == (
['power', 'vs', '0'], {'x.com.samsung.da.power': 'On'},
)
assert fan_desc.write_fn(('power', False, '/power/0'), {}) == (
['power', '0'], {'value': False},
)
def test_airflow_speed_reads_from_dump():
"""The fixture's /airflow/0 (power-off snapshot) reads speed=0, and
fan_direction stays a plain diagnostic (every dump seen reads 'Off'
regardless of fan setting)."""
state = _state()
assert state['airflow_fan'] == 0
assert state['fan_direction'] == 'Off'
@@ -0,0 +1,39 @@
"""Tests for the /mode/vs/0 match_fn discriminator in capabilities/
air_purifier.py (issue #130).
`_has_top_level_modes` decides whether a given air-purifier dump's shared
/mode/vs/0 href binds to the older ARTIK051_TVTL family's MODE capability
(packed options[] scheme) or the newer TP1X_DA-AC-AIR family's FAN
capability (modes/supportedModes reported directly). Pure function, no
coordinator/entity dependency needed to test it directly -- same rationale
as test_climate_wind_oscillation_fallback.py's `_oscillation_swing`.
"""
from custom_components.localthings.registry.capabilities.air_purifier import (
_has_top_level_modes,
)
def test_new_family_with_supported_modes_list_matches():
rep = {
'x.com.samsung.da.modes': ['Smart'],
'x.com.samsung.da.supportedModes': ['Smart', 'Max', 'Mid', 'WindFree', 'Sleep'],
}
assert _has_top_level_modes(rep, {}) is True
def test_old_family_with_no_supported_modes_field_does_not_match():
"""The ARTIK051_TVTL family's /mode/vs/0 packs everything into
options[] (Light_On, Comode_Off, ...) and has no top-level
supportedModes at all."""
rep = {
'x.com.samsung.da.options': ['Light_On', 'Comode_Off', 'OptionCode_60282'],
}
assert _has_top_level_modes(rep, {}) is False
def test_non_list_supported_modes_does_not_match():
assert _has_top_level_modes({'x.com.samsung.da.supportedModes': 'Smart'}, {}) is False
def test_empty_rep_does_not_match():
assert _has_top_level_modes({}, {}) is False
+155 -7
View File
@@ -93,15 +93,30 @@ def test_air_filter_usage_is_percentage_of_capacity():
def test_climate_write_targets():
"""The CLIMATE write_fn maps each (kind, value) command to the right OCF
POST target and body. `value` is already the raw device code."""
"""The CLIMATE write_fn maps each (kind, value) command to the right vendor
POST target and body. `value` is already the raw device code. Power and
temperature target the vendor /power/vs/0 and /temperatures/vs/0 (the OCF
/power/0 is absent on most boards and a non-authoritative mirror where
present; /temperature/desired/0 is only written via the temperature_ocf
kind, on boards that have the OCF pair)."""
write = airconditioner.CLIMATE.entities[0].write_fn
assert write(('power', True), {}) == (['power', '0'], {'value': True})
assert write(('power', False), {}) == (['power', '0'], {'value': False})
assert write(('power', True), {}) == (
['power', 'vs', '0'], {'x.com.samsung.da.power': 'On'})
assert write(('power', False), {}) == (
['power', 'vs', '0'], {'x.com.samsung.da.power': 'Off'})
assert write(('mode', 'Heat'), {}) == (
['mode', 'vs', '0'], {'x.com.samsung.da.modes': ['Heat']})
assert write(('temperature', 23.6), {}) == (
# OCF-pair boards: temperature_ocf -> /temperature/desired/0.
assert write(('temperature_ocf', 23.6), {}) == (
['temperature', 'desired', '0'], {'temperature': 24})
# Vendor boards: temperature -> /temperatures/vs/0, carrying only the id
# and the changed field -- the device merges current/min/max/unit itself
# (see common.merge_items_field, wired into async_send_command, for the
# read-side half that keeps the optimistic cache complete).
assert write(('temperature', 22), {}) == (
['temperatures', 'vs', '0'],
{'x.com.samsung.da.items': [
{'x.com.samsung.da.id': '0', 'x.com.samsung.da.desired': '22'}]})
assert write(('fan', '2'), {}) == (
['wind', 'strength', 'vs', '0'], {'x.com.samsung.da.modes': '2'})
assert write(('swing', 'All'), {}) == (
@@ -114,11 +129,13 @@ def test_climate_write_targets():
def test_climate_consumed_hrefs_declared_as_coverage():
"""The climate-consumed and ambiguous hrefs are declared in the AC registry
(as no-entity coverage caps) so they don't leak as gaps -- but produce no
standalone entities."""
standalone entities. /temperature/current/0 and /temperatures/vs/0 are
NOT in this list -- CURRENT_TEMPERATURE / CURRENT_TEMPERATURE_VS give
those two real sensor entities (issue #75)."""
reg, _ = _ac()
for href in ('/power/0', '/power/vs/0', '/temperature/desired/0',
'/wind/strength/vs/0', '/mode/convenient/vs/0',
'/temperatures/vs/0', '/sensors/vs/0', '/humidity/0'):
'/sensors/vs/0', '/humidity/0'):
caps = reg.capabilities.get(href)
assert caps, href
assert all(c.entities == () for c in caps), href
@@ -257,3 +274,134 @@ def test_current_limit_is_read_only():
than a guessed writable control."""
for desc in airconditioner.CURRENT_LIMIT.entities:
assert getattr(desc, 'write_fn', None) is None
# ---------------------------------------------------------------------------
# TP1X_DA-AC-RAC-01001 cool-only global variant (issue #91). Same modelNum as
# the issue #38 board above, but its /otninformation/vs/0 ships no
# swVersionInfo block, so oneUiVersion is empty and detection must fall back
# to the hyphenated '-RAC-' modelNum token (the older '_RAC_' underscore match
# doesn't fire on this DA-AC-RAC spelling). Adds /stepcontrol/vs/0 and
# /remotedeviceinfo/vs/0 (both ignored) and exposes the WindFree preset via
# the Nano/NanoSleep convenient-mode codes. Its panel light is carried inside
# /mode/vs/0's options blob instead of a dedicated /light/vs/0 switch.
# ---------------------------------------------------------------------------
def test_tp1x_rac_coolonly_resolves_via_hyphenated_model_fallback():
"""Empty oneUiVersion -> resolved by the '-RAC-' modelNum token, not
for_device(). Guards the regression where this unit loaded as 'unknown'."""
resources = _load_device('airconditioner_tp1x_rac_coolonly')
otn = resources.get('/otninformation/vs/0', {})
assert otn.get('swVersionInfo', {}).get('oneUiVersion', '') == ''
reg, _ = _resolve('airconditioner_tp1x_rac_coolonly')
assert reg is not None and reg.name == 'airconditioner'
def test_tp1x_rac_coolonly_no_unbound_hrefs():
"""Every resource binds or is ignored -- including the two hrefs unique
to this dump (/stepcontrol/vs/0, /remotedeviceinfo/vs/0). Clears the gap
repair."""
reg, resources = _resolve('airconditioner_tp1x_rac_coolonly')
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_tp1x_rac_coolonly_stray_hrefs_ignored():
ignored_hrefs = {cap.href for cap in airconditioner.COVERAGE}
assert '/stepcontrol/vs/0' in ignored_hrefs
assert '/remotedeviceinfo/vs/0' in ignored_hrefs
def test_tp1x_rac_coolonly_climate_bound():
reg, resources = _resolve('airconditioner_tp1x_rac_coolonly')
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
climate = [b for b in bound if isinstance(b.desc, ClimateDesc)]
assert len(climate) == 1 and climate[0].href == '/mode/vs/0'
def test_tp1x_rac_coolonly_display_light_from_mode_options():
"""This board has no /light/vs/0 switch; the panel light lives in
/mode/vs/0's options and surfaces as a display_light switch. The token is
inverted vs its name (confirmed by a live toggle test): with the panel
lit the option reads `Light_Off`, and with it dark it reads `Light_On`."""
reg, resources = _resolve('airconditioner_tp1x_rac_coolonly')
state = flatten(discover(resources, reg.capabilities, reg.pattern_capabilities), resources)
assert state.get('display_light') is True
def test_display_light_option_parsing_and_gating():
# Inverted token: Light_Off -> panel lit (on), Light_On -> panel dark (off).
lit = {'x.com.samsung.da.options': ['CoolCapa_35', 'Light_Off', 'Volume_Mute']}
dark = {'x.com.samsung.da.options': ['Light_On']}
absent = {'x.com.samsung.da.options': ['Volume_Mute']}
assert airconditioner._display_light_on(lit) is True
assert airconditioner._display_light_on(dark) is False
assert airconditioner._display_light_on(absent) is None
assert airconditioner._has_display_light_option(lit, {}) is True
assert airconditioner._has_display_light_option(absent, {}) is False
def test_mode_options_display_light_write_is_inverted_single_token():
"""Turning the lamp ON writes the inverted 'Light_Off' token as a
single-element options list (single-token merge); OFF writes 'Light_On'."""
sw = next(e for e in airconditioner.CLIMATE.entities if e.key == 'display_light')
assert sw.write_fn('On', {}) == (
['mode', 'vs', '0'], {'x.com.samsung.da.options': ['Light_Off']})
assert sw.write_fn('Off', {}) == (
['mode', 'vs', '0'], {'x.com.samsung.da.options': ['Light_On']})
def test_light_switch_board_gates_out_mode_options_light():
"""Boards with a real /light/vs/0 switch carry no Light_* option, so the
mode-options display-light entity doesn't double up (mutually exclusive
encodings)."""
reg, resources = _resolve('airconditioner_tp1x_rac')
assert airconditioner._has_display_light_option(resources['/mode/vs/0'], resources) is False
# ---------------------------------------------------------------------------
# WindFree unit (issue #75): same ARTIK051_PRAC_20K modelNum family as the
# original issue #17 fixture, but its /mode/convenient/vs/0 additionally
# supports Nano/NanoSleep/MotionDirect/MotionIndirect, /wind/direction/vs/0
# additionally supports Left_And_Right, and /humidity/vs/0's
# fivepercentHumidity is populated (unlike the all-zero original dump).
# ---------------------------------------------------------------------------
def _ac_windfree():
resources = _load_device('airconditioner_windfree')
info = resources['/information/vs/0']
reg = for_device_by_model(
info['x.com.samsung.da.modelNum'], info['x.com.samsung.da.description'],
)
return reg, resources
def test_windfree_no_unbound_hrefs():
reg, resources = _ac_windfree()
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_windfree_humidity_and_temperature_sensors_present():
reg, resources = _ac_windfree()
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
state = flatten(bound, resources)
assert state['humidity'] == 42.0 # fivepercentHumidity, not the stuck humidity=0 field
assert state['current_temperature_c'] == 27.0
def test_current_temperature_vs_only_binds_when_ocf_href_absent():
"""CURRENT_TEMPERATURE_VS's match_fn must not double-bind alongside
CURRENT_TEMPERATURE when a device (like this one) reports both
/temperature/current/0 and /temperatures/vs/0."""
match = airconditioner.CURRENT_TEMPERATURE_VS.match_fn
assert match({}, {'/temperature/current/0': {}}) is False
assert match({}, {}) is True
def test_humidity_reads_five_percent_field_not_stuck_humidity_field():
desc = airconditioner.HUMIDITY.entities[0]
rep = {'x.com.samsung.da.humidity': '0', 'x.com.samsung.da.fivepercentHumidity': '42'}
assert desc.value_fn(rep.get(desc.field)) == 42.0
+56
View File
@@ -0,0 +1,56 @@
"""Tests for registry.batch — the /device/0 sweep parser and its stub marker.
issue #127: a device whose /energy/consumption/vs/0 is permanently
unsupported reports a genuinely empty {} rep for it. The previous parser
collapsed /device/0's own {"href": "..."} "not fetched yet" marker to that
same {} shape, so downstream exists_fn checks couldn't tell "confirmed
empty" apart from "haven't polled it yet" and created phantom always-
"unknown" entities either way. is_stub_rep/parse_device0_batch now keep the
two shapes distinct.
"""
from custom_components.localthings.registry.batch import is_stub_rep, parse_device0_batch
class TestIsStubRep:
def test_true_for_bare_href_marker(self):
assert is_stub_rep({'href': '/energy/consumption/vs/0'}) is True
def test_false_for_genuinely_empty_rep(self):
assert is_stub_rep({}) is False
def test_false_for_populated_rep(self):
assert is_stub_rep({'x.com.samsung.da.cumulativePower': '58900'}) is False
def test_false_for_href_plus_data(self):
"""A real, populated rep may legitimately echo 'href' alongside
actual fields -- only a rep with *no other keys* is the stub."""
assert is_stub_rep({'href': '/x/0', 'value': True}) is False
class TestParseDevice0Batch:
def test_stub_rep_kept_distinct_from_genuine_empty(self):
device0 = [
{},
{'href': '/energy/consumption/vs/0', 'rep': {'href': '/energy/consumption/vs/0'}},
{'href': '/sabbath/vs/0', 'rep': {}},
]
resources = parse_device0_batch(device0)
assert is_stub_rep(resources['/energy/consumption/vs/0']) is True
assert is_stub_rep(resources['/sabbath/vs/0']) is False
assert resources['/sabbath/vs/0'] == {}
def test_populated_rep_passes_through_unchanged(self):
device0 = [
{},
{'href': '/door/cooler/0', 'rep': {'openState': 'Close'}},
]
resources = parse_device0_batch(device0)
assert resources['/door/cooler/0'] == {'openState': 'Close'}
def test_skips_entries_without_href(self):
device0 = [{}, {'rep': {'a': 1}}]
assert parse_device0_batch(device0) == {}
def test_skips_non_dict_rep(self):
device0 = [{}, {'href': '/x/0', 'rep': 'not-a-dict'}]
assert parse_device0_batch(device0) == {}
+248 -3
View File
@@ -42,9 +42,12 @@ class TestForDevice:
assert registry.name == 'refrigerator'
def test_for_device_returns_cooktop_registry(self):
"""The registry's own .name is 'gas_cooktop' (disambiguated from
induction_cooktop), but the lookup key devices route through stays
'cooktop' -- oneUiVersion "Cooktop" still resolves here."""
registry = for_device('7.0 Cooktop')
assert registry is not None
assert registry.name == 'cooktop'
assert registry.name == 'gas_cooktop'
def test_for_device_returns_range_hood_registry(self):
registry = for_device('7.0 Range Hood')
@@ -111,6 +114,46 @@ class TestWasherRegistry:
assert href in registry.capabilities, f"{href} missing from washer registry"
class TestModelNumSegments:
def test_splits_pipe_prefix_on_underscore(self):
from custom_components.localthings.registry.by_type import _model_num_segments
assert _model_num_segments('ARTIK051_DONGLE_REF|00127641|000800200014') == [
'ARTIK051', 'DONGLE', 'REF',
]
def test_ignores_everything_after_first_pipe(self):
from custom_components.localthings.registry.by_type import _model_num_segments
assert _model_num_segments('TP2X_RAC_20K|abc|REF_should_not_appear') == [
'TP2X', 'RAC', '20K',
]
def test_empty_for_none_or_empty_input(self):
from custom_components.localthings.registry.by_type import _model_num_segments
assert _model_num_segments('') == ['']
assert _model_num_segments(None) == ['']
class TestConsumerModelKey:
def test_finds_key_in_last_segment(self):
from custom_components.localthings.registry.by_type import _consumer_model_key
assert _consumer_model_key('DA_WM_TP1_21_COMMON_WW5000C') == 'washer'
def test_finds_key_before_a_trailing_unrecognized_segment(self):
"""Issue #79: 'DVE50A8800_8600' pairs two model numbers -- the real
consumer token is the second-to-last segment, not the last."""
from custom_components.localthings.registry.by_type import _consumer_model_key
assert _consumer_model_key(
'DA_WM_TP1_21_COMMON_DVE50A8800_8600/DC92-02835A_0080') == 'dryer'
def test_ignores_everything_after_first_slash(self):
from custom_components.localthings.registry.by_type import _consumer_model_key
assert _consumer_model_key('DA_WM_TP1_21_COMMON_WW5000C/DW9000_board') == 'washer'
def test_none_when_no_segment_matches(self):
from custom_components.localthings.registry.by_type import _consumer_model_key
assert _consumer_model_key('ARTIK051_DONGLE_REF') is None
class TestForDeviceByModel:
"""Fallback device-type detection for hardware without oneUiVersion."""
@@ -142,6 +185,20 @@ class TestForDeviceByModel:
assert reg is not None
assert reg.name == 'dryer'
def test_dryer_dve50a8600_paired_model_numbers_in_description(self):
"""Issue #79: description pairs two model numbers
('..._DVE50A8800_8600/DC92-...'), so the 'DV' consumer token is one
segment before the literal last segment ('8600', which has no
recognizable prefix on its own). The old last-segment-only check
fell through to 'unknown' here."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'DA_WM_TP1_21_COMMON|20286441|300000010015110002A3031700000000',
'DA_WM_TP1_21_COMMON_DVE50A8800_8600/DC92-02835A_0080',
)
assert reg is not None
assert reg.name == 'dryer'
def test_dishwasher_not_misdetected_as_washer(self):
"""Dishwasher's modelNum contains the substring 'WW' -- must not
be misrouted by a naive substring match."""
@@ -178,6 +235,20 @@ class TestForDeviceByModel:
assert reg is not None
assert reg.name == 'refrigerator'
def test_refrigerator_dongle_ref_pipe_delimited_modelnum(self):
"""Issues #77/#83: the ARTIK051_DONGLE_REF family's modelNum is
'<board>_DONGLE_REF|<rest>' -- REF is the last underscore segment
before the pipe, with no trailing underscore, so the plain '_REF_'
substring check used to miss it entirely and the device fell back
to 'unknown' with only common capabilities."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'ARTIK051_DONGLE_REF|00127641|00080020001430300100000000000000',
'ARTIK_REF_17K',
)
assert reg is not None
assert reg.name == 'refrigerator'
def test_airconditioner_via_prac_token(self):
"""Issue #17: a room AC (ARTIK051_PRAC_20K) reports no oneUiVersion and
an unrecognized consumer token ('20K'); it falls back to the '_PRAC_'
@@ -190,6 +261,104 @@ class TestForDeviceByModel:
assert reg is not None
assert reg.name == 'airconditioner'
def test_dehumidifier_via_dhm_token(self):
"""Issue #88: a dehumidifier (AY18CG7500GED) shares the DA_AC_ board
family with the room-AC models but reports no oneUiVersion and
carries the '_DHM_' (DeHuMidifier) token instead of
'_RAC_'/'_PRAC_'/'_WAC_'; falls back to the '_DHM_' token in
modelNum."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'TP1X_DA_AC_DHM_01001_0000|10253841|77000000001700000A00000000000000',
'TP1X_DA_AC_DHM_01001_0000',
)
assert reg is not None
assert reg.name == 'dehumidifier'
def test_water_purifier_via_waterpurifier_token(self):
"""Issue #90: a water purifier (TP2X_WATERPURIFIER_20K) reports no
oneUiVersion and no consumer-prefix match; falls back to the
'WATERPURIFIER' token shared by modelNum and description."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'TP2X_WATERPURIFIER_20K|00132341|900000000215130001060F0000020000',
'TP2X_WATERPURIFIER_20K',
)
assert reg is not None
assert reg.name == 'water_purifier'
def test_airconditioner_via_wac_token(self):
"""Issue #87: a Bespoke Window AC (AW06C7155EWAZ) reports no
oneUiVersion and a modelNum carrying the '_WAC_' (Window Air
Conditioner) token instead of '_RAC_'/'_PRAC_'; falls back to the
'_WAC_' token in modelNum."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'TP1X_DA_AC_WAC_01001_0000|40460041|50030018001611020A00000000000000',
'AW06C7155EWAZ',
)
assert reg is not None
assert reg.name == 'airconditioner'
def test_wac_token_not_shadowed_by_wa_washer_prefix(self):
"""Regression: adding the 'WA' consumer-model prefix (issue #106)
must not hijack devices whose description literally equals their
modelNum (e.g. the Window AC family, issue #87) and so contains a
'WAC' segment -- 'WAC'[:2] == 'WA' would otherwise match the washer
prefix before the more specific '_WAC_' modelNum check ever runs."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'TP1X_DA_AC_WAC_01001_0000|40460041|50030018001611020A00000000000000',
'TP1X_DA_AC_WAC_01001_0000',
)
assert reg is not None
assert reg.name == 'airconditioner'
def test_airconditioner_via_ara_ww_token(self):
"""Issues #115/#116/#117/#120: ARA-WW-TP1-22-COMMON wall-mount RACs
(AR10/13/18BYEAAWKNME) report no oneUiVersion and no
'_RAC_'/'-RAC-'/'_PRAC_' token at all -- falls back to the
'ARA-WW-' token in modelNum, reusing the same airconditioner
registry as every other TP1X-class room AC rather than a new
device type."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'ARA-WW-TP1-22-COMMON|10229641|6001051A001511014600083200800000',
'ARA-WW-TP1-22-COMMON',
)
assert reg is not None
assert reg.name == 'airconditioner'
def test_microwave_via_microwave_token(self):
"""Issue #121/#66: a combi microwave (MW7300B-/EU1) reports no
oneUiVersion and an unrecognized consumer token; falls back to the
'-MICROWAVE-' token in modelNum onto its own microwave registry
(initially folded into 'oven' for issue #121, split out into a
distinct device type per user feedback)."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'TP1X_DA-KS-MICROWAVE-01041|40475341|50040100021811000A00000000000000',
'MW7300B-/EU1',
)
assert reg is not None
assert reg.name == 'microwave'
def test_vacuum_station_via_vskr_token(self):
"""Issue #131: a stick-vacuum clean/auto-empty station
(A-VSKR-TP1-22-VS9500AL) reports no oneUiVersion and no
washer/dryer/dishwasher consumer prefix; falls back to the
'-VSKR-' token in modelNum onto a new vacuum_station registry (its
dump has no vacuum-body state at all, only station-specific
dustbag/dustbin/UV-sanitize resources -- see
capabilities/vacuum_station.py's module docstring)."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'A-VSKR-TP1-22-VS9500AL|50023541|80030100001611000800000000000000',
'A-VSKR-TP1-22-VS9500AL',
)
assert reg is not None
assert reg.name == 'vacuum_station'
def test_cooktop_via_legacy_model_description(self):
"""Older cooktops identify themselves as ARTIK051_GLOBAL_COOKTOP."""
from custom_components.localthings.registry.by_type import for_device_by_model
@@ -198,7 +367,7 @@ class TestForDeviceByModel:
'ARTIK051_GLOBAL_COOKTOP',
)
assert reg is not None
assert reg.name == 'cooktop'
assert reg.name == 'gas_cooktop'
def test_range_hood_via_ahd_model(self):
from custom_components.localthings.registry.by_type import for_device_by_model
@@ -229,6 +398,17 @@ class TestForDeviceByModel:
assert reg is not None
assert reg.name == 'washer'
def test_washer_wa_prefix(self):
"""Top-load washers (e.g. WA8000T) use the WA consumer-model prefix
-- issue #106."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'DA_WM_TP2_20_COMMON|20233741|200000010014110002A3020200000000',
'DA_WM_TP2_20_COMMON_WA8000T/DC92-02810A_0002',
)
assert reg is not None
assert reg.name == 'washer'
def test_oven_via_oven_token(self):
"""Issue #55: a wall oven (NV7000BS/ET5) reports no oneUiVersion and
an unrecognized consumer token ('NV'); it falls back to the '-OVEN-'
@@ -241,6 +421,28 @@ class TestForDeviceByModel:
assert reg is not None
assert reg.name == 'oven'
def test_induction_cooktop_via_hyphenated_cooktop_token(self):
"""Issue #86: a standalone induction cooktop (NV8500T-/KO4) reports
no oneUiVersion and an unrecognized consumer token ('NV'); it falls
back to the hyphenated '-COOKTOP-' token in modelNum -- distinct
from the underscore-delimited '_COOKTOP'/'_GB_CT_' check, which is
the unrelated older NA9300K gas-cooktop family."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'TP1X_DA-KS-COOKTOP-01011|40459741|50000203001711000A00000000000000',
'NV8500T-/KO4',
)
assert reg is not None
assert reg.name == 'induction_cooktop'
def test_hyphenated_cooktop_token_not_confused_with_range(self):
"""'-COOKTOP-' and '-RANGE-' must route to distinct registries even
though both are TP1X_DA-KS- board-family siblings."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model('TP1X_DA-KS-COOKTOP-01011', 'NV8500T-/KO4')
assert reg is not None
assert reg.name != 'range'
def test_unknown_model_returns_none(self):
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model('SOME-UNKNOWN-BOARD', 'SOME-UNKNOWN-BOARD')
@@ -259,7 +461,7 @@ class TestForDeviceByResources:
reg = for_device_by_resources(_load_device('cooktop'))
assert reg is not None
assert reg.name == 'cooktop'
assert reg.name == 'gas_cooktop'
def test_unrelated_mode_options_are_not_cooktop(self):
from custom_components.localthings.registry.by_type import for_device_by_resources
@@ -284,3 +486,46 @@ class TestForDeviceByResources:
reg = for_device_by_resources(resources)
assert reg is not None
assert reg.name == 'range_hood'
def test_ne63b8411ss_without_information_or_burner_status_is_range(self):
"""Issue #74: no oneUiVersion, no /information/vs/0 at all, and no
/cooktop/status/vs/0 burner array -- only /cooktopmonitoring/vs/0.
'Bake' in supportedModes plus that monitoring resource must still
route this to the range registry, not plain oven or unknown."""
from custom_components.localthings.registry.by_type import for_device_by_resources
resources = {
'/mode/vs/0': {
'x.com.samsung.da.supportedModes': ['Bake', 'Broil', 'SelfClean'],
'x.com.samsung.da.options': ['DeviceType_NE8411B-/AC0'],
},
'/oven/vs/0': {'x.com.samsung.da.state': 'Ready'},
'/cooktopmonitoring/vs/0': {'x.com.samsung.da.cooktopRunningState': 'Ready'},
}
reg = for_device_by_resources(resources)
assert reg is not None
assert reg.name == 'range'
def test_bake_without_cooktop_resource_is_plain_oven(self):
from custom_components.localthings.registry.by_type import for_device_by_resources
resources = {
'/mode/vs/0': {
'x.com.samsung.da.supportedModes': ['Bake', 'Broil'],
'x.com.samsung.da.options': ['DeviceType_SOME_OVEN'],
},
'/oven/vs/0': {'x.com.samsung.da.state': 'Ready'},
}
reg = for_device_by_resources(resources)
assert reg is not None
assert reg.name == 'oven'
def test_bake_without_oven_cavity_resource_is_not_matched(self):
"""'Bake' alone isn't enough -- the oven cavity resource must also
be present, or this falls through to None like any other unknown
shape."""
from custom_components.localthings.registry.by_type import for_device_by_resources
resources = {
'/mode/vs/0': {
'x.com.samsung.da.supportedModes': ['Bake', 'Broil'],
},
}
assert for_device_by_resources(resources) is None
+76
View File
@@ -0,0 +1,76 @@
"""Tests for the AC HVAC-mode/preset device<->HA maps in climate.py (issue #93).
Module-level dicts/constants with no coordinator/entity dependency, so --
like `_temps_vs_item` in test_climate_temperature_fallback.py -- they're
testable directly.
"""
from homeassistant.components.climate import HVACMode
from custom_components.localthings.climate import (
_AI_COMFORT_MODE, _DEVICE_TO_HVAC, _HVAC_TO_DEVICE, PRESET_AI_COMFORT,
_preset_to_ha,
)
def test_auto_maps_to_hvac_auto():
"""The device's 'Auto' is a single-setpoint "device decides" mode -> HA
HVACMode.AUTO, not HEAT_COOL (issue #91 review): HEAT_COOL implies a
two-setpoint heat+cool range these single-setpoint units (including
cool-only models) don't have. AIComfort is handled separately, not
folded into this map."""
assert _DEVICE_TO_HVAC['Auto'] == HVACMode.AUTO
def test_aicomfort_not_in_flat_hvac_map():
"""AIComfort isn't a flat _DEVICE_TO_HVAC entry -- it's an AI overlay on
top of 'Auto', modeled as hvac_mode=AUTO + a dedicated preset instead of
a distinct HVACMode value (see the climate.py module comment)."""
assert _AI_COMFORT_MODE not in _DEVICE_TO_HVAC
def test_hvac_auto_writes_back_to_plain_auto_not_aicomfort():
"""HVACMode.AUTO is reachable via async_set_hvac_mode -- it writes the
device's plain 'Auto' code. AIComfort stays reachable only through the
ai_comfort preset, since it isn't a flat _DEVICE_TO_HVAC entry (see
test_aicomfort_not_in_flat_hvac_map) and so can never win the reverse
{v: k} dict even though both map to HVACMode.AUTO conceptually."""
assert _HVAC_TO_DEVICE[HVACMode.AUTO] == 'Auto'
def test_fan_only_still_reachable_via_wind():
"""Guard against regressing the existing 'Wind' -> FAN_ONLY entry while
editing this map."""
assert _DEVICE_TO_HVAC['Wind'] == HVACMode.FAN_ONLY
def test_fan_only_still_reachable_via_fan():
"""'Fan' (e.g. TP1X_DA-AC-RAC-01011) is a second FAN_ONLY spelling
alongside 'Wind' -- issue #91."""
assert _DEVICE_TO_HVAC['Fan'] == HVACMode.FAN_ONLY
def test_fan_only_reverse_fallback_prefers_wind():
"""_device_code_for_hvac() resolves FAN_ONLY from a unit's own
supportedModes first, so _HVAC_TO_DEVICE is only a fallback for a unit
reporting no supportedModes at all. That fallback must stay 'Wind' (the
original single spelling, predating 'Fan') rather than silently
flipping to whichever of the two duplicate-value entries happens to
come last in _DEVICE_TO_HVAC."""
assert _HVAC_TO_DEVICE[HVACMode.FAN_ONLY] == 'Wind'
def test_preset_ai_comfort_constant():
assert PRESET_AI_COMFORT == 'ai_comfort'
def test_preset_to_ha_off_maps_to_preset_none():
from homeassistant.components.climate import PRESET_NONE
assert _preset_to_ha('Off') == PRESET_NONE
def test_preset_to_ha_lowercases_other_codes():
"""Every other device code is exposed as its lowercased self -- resolved
dynamically, not via a per-model table (issue #91)."""
assert _preset_to_ha('Sleep') == 'sleep'
assert _preset_to_ha('NanoSleep') == 'nanosleep'
assert _preset_to_ha('MotionIndirect') == 'motionindirect'
@@ -0,0 +1,33 @@
"""Tests for the /wind/oscillation/vs/0 swing fallback helper in climate.py
(issue #126).
`_oscillation_swing` is a pure module-level function, like `_temps_vs_item`
in test_climate_temperature_fallback.py -- testable directly without a
coordinator/entity. This covers the fallback-selection logic that the
registry-level "no unbound hrefs" test in test_golden_regression.py doesn't
reach: newer WindFree firmware reports no /wind/direction/vs/0 at all, so
swing_mode/swing_modes would silently be None/empty without this fallback.
"""
from custom_components.localthings.climate import _oscillation_swing
def test_oscillation_swing_off_when_both_fixed():
assert _oscillation_swing({'vertical': 'Fix', 'horizontal': 'Fix'}) == 'off'
def test_oscillation_swing_vertical_only():
assert _oscillation_swing({'vertical': 'Swing', 'horizontal': 'Fix'}) == 'vertical'
def test_oscillation_swing_horizontal_only():
assert _oscillation_swing({'vertical': 'Fix', 'horizontal': 'Swing'}) == 'horizontal'
def test_oscillation_swing_both():
assert _oscillation_swing({'vertical': 'Swing', 'horizontal': 'Swing'}) == 'both'
def test_oscillation_swing_none_when_resource_absent():
"""Boards with /wind/direction/vs/0 instead don't populate this
resource at all -- callers must fall through cleanly, not raise."""
assert _oscillation_swing({}) is None