Marc Billow 8ca2c3cb16 Address opus review: Fahrenheit setpoint bounds, OVEN_SPEC coverage, docstring
- NumberDesc gains native_min_fn/native_max_fn/step_fn hooks (mirroring the
  existing unit_fn pattern) so an entity's slider bounds can track the live
  rep instead of staying pinned to whatever unit the descriptor was written
  against. Oven setpoint was hardcoded to Celsius bounds (30-270), which
  silently capped issue #44's Fahrenheit range at 270F -- below a normal
  350F bake temp. Verified Fahrenheit bounds (175-550, step 5) come from
  that dump's /mode/vs/0 Bake modeSpec.
- Wire oven.OVEN_SPEC into the oven registry, not just range -- it was only
  reachable from range before, so a standalone oven reporting
  /oven/spec/vs/0 would have false-tripped the coverage-gap repair.
- Fix a docstring in test_golden_regression.py left over from the
  cooktop.py -> range.py rename.
2026-07-23 02:32:34 +00:00
Marc Billow aec3c5e460 Rename cooktop.py capabilities module to range.py to avoid PR #23 collision
PR #23 independently adds registry/capabilities/cooktop.py for an unrelated
standalone-cooktop product (NA9300K-class, burner state encoded in
/mode/vs/0's options array) -- different hardware and a different OCF
surface than issue #44's oven+cooktop combo range, but the same file path.
Rename ours to range.py to keep both mergeable.
2026-07-23 02:32:34 +00:00
Marc Billow 321f186b0e Add range/cooktop-oven combo support (issue #44)
TP1X_DA-KS-RANGE-0102X (model NSI6DG9100SRAA) reports no oneUiVersion and
previously fell through to the unknown-device fallback, leaving /connected,
/cooktop/spec, /cooktop/settings/status, /cooktop/status, and /oven/spec
unbound. Add a 'range' device registry that reuses the oven family's
cavity/setpoint/mode/operational-state/door capabilities and adds a new
cooktop.py module modeling per-burner power level, state, and hot-surface
entities (gated so unreported burner slots don't appear), plus a hot-surface
auto-shutoff config sensor. Route range/cooktop models to it via a
'-RANGE-' modelNum token, mirroring the existing RAC/PRAC air-conditioner
fallback pattern.

The dryer (DA_WM_TP1_21_COMMON) pause/stop buttons mentioned in the same
issue are working as intended -- the reporter confirmed that's an expected
in-person-only limitation, not a bug.
2026-07-23 02:32:34 +00:00
Marc Billow 1e9437ef3c Merge pull request #46 from mbillow/claude/issue-27-investigation-ff60pw
fix(fridge,observe): merge partial cache updates, name ice makers dynamically
2026-07-22 20:31:19 -05:00
Marc Billow 36f7aa0b8c refactor: dedup naming helpers, close observe-cache merge race
/simplify pass on the issue #27 fix: extract a shared _snake_to_title
between entity.py and discovery.py, factor discover()'s two binding
loops through one _bind() helper, and close a TOCTOU race the cache
merge introduced -- apply() is the sole path StateCache mutations flow
through, so the read-then-write is now serialized under one lock
instead of two independently-locked calls.
2026-07-23 01:28:47 +00:00
Marc Billow 10ab51c7f3 fix(fridge,observe): merge partial cache updates, name ice makers dynamically
Issue #27: the flex-zone/cooler-drawer select vanished after a device
stopped including supportedOptions on an update for /mode/vs/0.
ObserveManager.apply() handed reps straight to StateCache.apply_rep,
which fully replaces the cached rep -- so a partial update (missing a
field the select's exists_fn/options_field gate on) silently erased
data a fuller update had previously supplied. apply() now merges
incoming reps onto whatever's already cached instead.

Also give ice-maker entities (and any future pattern-cap instance) a
device-given display name instead of the href-derived "Icemaker
One"/"Icemaker Two": Capability.name_field lets a pattern capability
read and normalize an instance name (e.g. iceMaker.name's "CUBED_ICE")
for use as the entity name prefix, independent of the stable
key/unique_id.
2026-07-23 01:28:35 +00:00
Marc Billow fb0f24a175 Fix AC climate state lag by promoting consumed hrefs to warm poll tier
CLIMATE_CONSUMED_HREFS (power, current/target temp, fan, swing, preset)
were bound as no-entity coverage capabilities with the Capability
default poll_tier='cold'. The coordinator only OBSERVE-subscribes and
sub-polls 'hot'/'warm' hrefs, so cold-tier state only refreshed on the
~30s full /device/0 summary sweep -- matching the 20-30s HA lag reported
on issue #17 despite commands landing on the device instantly. Pin them
to 'warm', same as CLIMATE's own primary href, so they get push
notifications (or warm-tier sub-polling as a poll-only fallback).
2026-07-23 01:01:39 +00:00
Marc Billow 1493467c63 Fix AI energy level platform-flip bug found in Opus review
The switch and select shared a stub-time asymmetry: only the select had a
`not rep` carve-out, so an unfetched-stub rep at the moment platforms are
set up (entity creation runs once, ever) would instantiate a Select, while
flatten() re-evaluates exists_fn every poll against live data -- once the
resource populated to a single-level list, the switch's exists_fn would win
instead and feed the already-created Select a bool through their shared
'ai_energy_level' key, which isn't a valid select option.

Dropped the stub carve-out from the select's exists_fn so both sides
require real, populated data to decide the platform -- on a device that
stubs this cold-tier href on its very first poll, the entity now simply
doesn't appear until a reload, instead of appearing as the wrong widget
type. Added tests for the missing/empty-list supportedAiLevel shapes on
both widgets and a regression test locking in the stub behavior.
2026-07-23 00:44:58 +00:00
Marc Billow 61ee2972dc Trim duplicated comments from /simplify review
Consolidate the AC/power-exclusion rationale (previously spelled out nearly
verbatim in three places) down to one canonical explanation next to
common.POWER, with one-line pointers elsewhere. Dedupe the switch/select
test classes' identical _desc() lookup into one shared helper.
2026-07-23 00:44:58 +00:00
Marc Billow 3d5263d792 Add common.UNIVERSAL/POWER bundles to stop hand-duplicating capabilities
FIRMWARE_UPDATE and ALARMS were already copy-pasted into all 6 device-type
registries by hand; POWER/KIDS_LOCK/REMOTE_CONTROL into 5 of 6. Consolidate
into two bundles in common.py, unpacked via *common.UNIVERSAL / *common.POWER
the same way ignored.IGNORED already is:

- UNIVERSAL: ALARMS, ENERGY_METER, FIRMWARE_UPDATE (moved from fridge.py),
  SELF_CHECK (moved from fridge.py), AI_ENERGY_LEVEL, and the kids-lock/
  remote-control pairs. Safe everywhere -- discover() only binds a href
  actually present in a device's dump, so a capability with no known
  conflicting family is a no-op where the href is absent and a real,
  wanted entity where it's present. This also broadens AI_ENERGY_LEVEL,
  ENERGY_METER, and SELF_CHECK to device types they weren't confirmed on
  before, on the same reasoning.
- POWER: just POWER_GENERIC/POWER_VS_FALLBACK, applied to the 5 non-AC
  registries. Airconditioner keeps its own opt-out: its climate entity
  already owns /power/0 and /power/vs/0 via a bare, no-entity claim
  (airconditioner.COVERAGE), and a real power capability on the same
  href would make _build() raise (a href with multiple caps requires
  every cap to have rt_filter or match_fn; the bare COVERAGE cap has
  neither).

Full test suite (327 tests, all 6 device-type golden fixtures) passes
unchanged -- none of the newly-broadened capabilities bind on any existing
fixture, confirming the no-op reasoning held in practice, not just theory.
2026-07-23 00:44:58 +00:00
Marc Billow d6639c99d4 Bind AI energy level on washer; switch/select split, drop translations
Issue #40: /energy/ailevel/vs/0 was unbound on a plain washer. The
capability already existed for fridges but was gated off entirely on
single-level hardware (the common case), so it's moved to common.py
(cross-family, like fridge + washer now) and split into two entities:
a switch when supportedAiLevel has exactly one entry (aiLevel is really
just an on/off toggle there), and a select otherwise, with '0' (off)
synthesized back into the select's options since supportedAiLevel never
lists it but it's a real observed value.

Also drops the translation_key/strings.json entries -- aiLevel's raw
digit values already render fine untranslated, and translating a
handful of levels can't cover devices with more.
2026-07-23 00:44:57 +00:00
Marc Billow 9800cd0aa8 refactor: lift options[] boolean-toggle machinery into laundry.py
Addresses the reuse finding skipped in the previous /simplify pass:
washer's bubble soak/pre-wash/intensive switches and dishwasher's storm
wash/auto release dry switches were two separate implementations of the
same '<prefix>_On'/'<prefix>_Off' read-modify-write-on-options[] contract.

Moved bool_option_write/bool_option_value/bool_option_exists/
bool_option_switch into laundry.py (same module that already owns
cycle_write/cycle_select for the identical 'Course' token), and pointed
both washer.py and dishwasher.py at it. washer.py keeps only its
washer-specific per-course validate_fn, passed into the shared factory
as a prebuilt callable -- the factory itself has no opinion on validation.

No behavior change; re-verified every existing assertion (washer toggles,
dishwasher storm_wash/auto_release_dry, dosing alarms) plus all golden
state-key sets by hand against the refactored code.
2026-07-22 19:45:57 +00:00
Marc Billow 3469f57080 refactor: simplify washer toggle switches, move validate_fn to coordinator
/simplify pass on the bubble soak/pre-wash/intensive switches:
- Move validate_fn dispatch from switch.py into coordinator.async_send_command,
  next to the existing write_fn getattr -- every platform gets validation for
  free instead of switch.py hand-rolling it alone, and it avoids building the
  full resources snapshot twice per write (switch.py was calling
  coordinator.last_resources twice; the coordinator now snapshots once, and
  only when a validate_fn is actually present).
- Collapse the four per-switch factories (write/value/exists/validate) plus
  the _AVAILABILITY_FIELD side-table into one _bool_option_switch() that
  builds the SwitchDesc directly, so the three call sites read as one line
  each instead of six, and a typo'd prefix can no longer silently KeyError
  against a separate lookup table.
- Rename _dosing_alarm_exists to _option_exists and reuse it for the new
  switches too -- it was already the exact same "is this token present"
  check the toggles need.

No behavior change; re-verified write_fn/rep_fn/exists_fn/validate_fn against
the same fixtures and golden state-key sets as before.
2026-07-22 19:45:57 +00:00
Marc Billow f54daf3608 feat: reject bubble soak/pre-wash/intensive writes on unsupported courses
Add a validate_fn hook to SwitchDesc, checked in switch.py before dispatch
and surfaced as a ServiceValidationError so an unsupported write shows a
real error in the UI instead of the coordinator's silent log-only rejection.

Wired it into the three course-gated washer switches using their
availability bitmaps (BubbleSoakSet/PreWashAvailableSet/IntensiveAvailableSet),
which line up positionally with editCourseList. Turning a toggle off is
never blocked, and the check fails open whenever the course or bitmap can't
be resolved.

Also fixes a bug in _bool_option_write: it took a `p and 'On' or 'Off'`-style
truthy check, but switch.py always calls it with the string 'On' or 'Off' --
both truthy, so every write landed as 'On' regardless of intent.
2026-07-22 19:45:57 +00:00
Marc Billow e49b61e01e feat: add bubble soak, pre-wash, and intensive switches for washers (#22)
A follow-up dump confirmed these ride as plain BubbleSoak_On/Off,
PreWashSetting_On/Off, and IntensiveSetting_On/Off tokens in the same
/course/vs/0 options array as the cycle select, so they're exposed as
self-gating config switches the same way other options-array fields are.

Per-cycle availability (BubbleSoakSet/PreWashAvailableSet/IntensiveAvailableSet)
lines up positionally with editCourseList but isn't used for gating, since
exists_fn only runs once at setup against whatever course happened to be
active then.
2026-07-22 19:45:57 +00:00
Marc Billow 7d011bfe89 fix: add missing washer cycle translations for combo units (#22)
A washer/dryer combo user's editCourseList carries five Course_XX codes
that weren't named in washer_cycle: 36 (Wash+Dry), 37 (Air Wash),
38 (Cotton Dry), 39 (Synthetics Dry), and 1F (Intense Cold, distinct
from the existing 8F code used by non-combo models).
2026-07-22 18:50:56 +00:00
Marc Billow 6611f85958 chore: bump version to 0.9.0
Covers PR #36's TP1X temperature-fallback fix and display-light switch,
plus TP2X_RAC_20K device-type recognition and full TP1X_DA-AC-RAC-01001
capability coverage (issues #37, #38).
2026-07-22 14:25:10 +00:00
Marc Billow e942c822a6 feat: extend AC support for TP2X_RAC_20K and TP1X_DA-AC-RAC-01001_0000
Closes the coverage-gap repair for two more room-AC boards (issues #37,

- TP2X_RAC_20K reports no oneUiVersion and no '_PRAC_' modelNum token, so
  its device type went unrecognized -- add a '_RAC_' fallback token to
  for_device_by_model.
- Bind the resources both dumps actually populate: mute-once (switch),
  display light (switch), self-check (reused from fridge.SELF_CHECK), and
  the circuit-breaker current-limit setting (read-only diagnostic sensors,
  since its write contract isn't confirmed from the dump).
- Ignore the rest as plumbing/opaque/unconfirmed: control-set descriptor,
  keepnormalstate flag, software-reset trigger, AI Sleep handshake,
  absence-monitoring stubs, remote-data-control, remote-temperature,
  reservation ruleset, and the welcome-temperature tracker.

Adds scrubbed fixtures + goldens for both dumps and extends the AC
capability/golden-regression tests to assert zero unbound hrefs.
2026-07-22 14:20:55 +00:00
paddawan2002 bc9d4f4cf5 Fix AC coverage for TP1X-class (oneUiVersion "7.0 Air conditioner") 2026-07-22 11:26:01 +02:00
Tim Schindler 0cc9d8e511 fix: render selfcheck_error as no-value on empty list; document ai_energy_level level labels 2026-07-22 09:04:24 +02:00
Tim Schindler 2a0a9f32ee feat: add AI energy level select and self-check error sensor for fridges
Adds two small, additive fridge capabilities:

- AI_ENERGY_LEVEL: a select on /energy/ailevel/vs/0 exposing the AI
  energy-saving level, gated behind supportedAiLevel actually offering
  more than one choice (previously globally ignored since every dump
  seen only reported a single supported level).
- selfcheck_error: a diagnostic sensor on the existing SELF_CHECK
  capability surfacing x.com.samsung.da.error from the last self-check,
  for hardware that reports it.

This does not touch FLEX_ZONE, /mode/vs/0, or /icemaker/status/0.
2026-07-22 08:42:31 +02:00
Marc Billow 5a9a002a7f chore: bump version to 0.8.0
Covers the #19-#27 fridge/washer coverage-gap batch: FlexWash (WV) and
washer/dryer combo detection, the CV_FDR_ flex-zone fix (also closes #32),
the Cool Select Zone pantry select, and the new energy sensors.
2026-07-22 06:12:17 +00:00
Marc Billow 43542b146f fix: restore empty-stub carve-out on the new energy sensors; dedupe flex-zone set build
Review follow-up (Opus + /simplify) on the previous commit:

- power_energy_kwh/energy_saved_kwh/energy_last_month_kwh/
  energy_this_month_kwh used a plain `field in rep` exists_fn, unlike their
  siblings power_watts/energy_kwh in the same capability. Per
  entity._is_included, an explicit exists_fn bypasses the stub carve-out
  entirely -- an empty {} rep at platform setup (device/0 returned a
  not-yet-fetched stub) would permanently drop these entities for the
  session instead of picking them up once a sub-poll populates the
  resource. Restore the same `not rep or ...` guard used above.
- fridge._flex_zone_current/_flex_zone_write independently rebuilt the same
  supportedOptions set; factor into _flex_zone_supported.
- note in a comment that the flex-zone match assumes at most one
  modes/supportedOptions overlap (true on every dump seen); add the
  missing negative assertion that dry_level self-gates off on a plain
  washer (was only positively asserted on the combo fixture).
2026-07-22 06:11:16 +00:00
Marc Billow 9a899080fa fix: fridge/washer coverage gaps from the #19-#27 dump batch
Six new diagnostics dumps, six gaps closed:

- refrigerator: bind /diagnosis/vs/0 (reuse dishwasher.DIAGNOSIS -- same
  shape) into the refrigerator registry; it was never wired up there,
  tripping the coverage repair on any fridge that reports it (#20, #26).
- refrigerator: add PANTRY_ZONE for the Cool Select Zone pantry compartment
  (/status/pantry/one/vs/0, x.com.samsung.da.mode/supportedOptions) -- same
  shape as BEVERAGE_ZONE but a distinct resource/field set (#20).
- refrigerator: generalize FLEX_ZONE to identify the current mode by list
  membership in supportedOptions instead of a hardcoded
  CV_TTYPE_RF9000A_ prefix check. TP1X/Bespoke-class fridges use a
  CV_FDR_ prefix instead, which the old code didn't recognize -- the
  select existed but always read as unknown, and writing to it would have
  appended a duplicate CV_FDR_ flag rather than replacing the existing one
  (#26, #27; also closes #32).
- common: add energy_saved_kwh (x.com.samsung.da.cumulativeSavedPower) and
  power_energy_kwh (x.com.samsung.da.cumulativeConsumption) to the shared
  energy meter, plus fridge-only energy_last_month_kwh/energy_this_month_kwh
  (monthlyConsumption/thismonthlyConsumption) -- all self-gating on field
  presence (#26).
- by_type: add the WV consumer-model prefix (FlexWash twin washers, e.g.
  WV55M9600AW) to the by-model fallback map. These report no oneUiVersion
  and previously matched no prefix at all, so they fell all the way
  through to the unrecognized-device registry with zero capabilities
  bound (#19).
- washer: add a self-gating dry_level select to WASHER_SETTINGS for
  washer/dryer combo units, which carry a writable dryLevel field
  directly on /washer/vs/0 with no separate dryer resource or course
  (#22).

The reset-water-filter button and "ice type vs. two named icemakers"
requests from #26/#27 are left alone -- no write contract or exclusivity
behavior is evidenced in either dump, and both icemakers report On
simultaneously on the Bespoke unit, so synthesizing a single-select would
be a guess rather than a fix.

Adds scrubbed fixtures + goldens for FlexWash, a washer/dryer combo,
ARTIK051_REF_17K, and TP2X_REF_20K, plus unit tests for the new/changed
capabilities.
2026-07-22 06:11:15 +00:00
Marc Billow 88e630b54f feat: detect FlexWash (WV) washers; add combo dry-level select
- WV consumer-model prefix (FlexWash twin washers, e.g. WV55M9600AW)
  wasn't in the by-model fallback map, so these units fell through to
  the unknown-device registry with zero capabilities bound (#19).
- Washer/dryer combo units carry a writable dryLevel field directly on
  /washer/vs/0 with no separate dryer resource; add a self-gating
  select for it, off supportedDryLevel presence, so plain washers are
  unaffected (#22).
2026-07-22 06:11:15 +00:00
Marc Billow 70a7f861c3 Merge pull request #25 from themaanda/contrib/detect-wf-washers
Detect WF-series washer models
2026-07-22 00:20:36 -05:00
Marc Billow ff034905a2 Merge pull request #24 from themaanda/contrib/tp1x-refrigerator-mirrors
Cover TP1X refrigerator native resource mirrors
2026-07-22 00:20:03 -05:00
Marc Billow 3688cf24a0 chore: bump version to 0.7.0
Covers the air-conditioner support (#17) and the washer dosing-select /
diagnostics fixes (#9). main was still advertising 0.6.0 despite the AC work
already merging, so this moves it for the next release.
2026-07-22 00:15:22 +00:00
Marc Billow f4b4a04628 refactor: tidy the AC climate entity (/simplify pass)
Quality-only cleanups on the air-conditioner support, no behavior change:

- climate.py: reuse common.normalize_temp_unit for the C/F unit read (also
  handles the "Celsius"/"Fahrenheit" long forms); collapse the three
  fan/swing/preset read properties into _read_mode/_read_modes and the three
  write setters into _set_mapped, removing the copy-paste.
- Single source of truth for the climate-consumed hrefs: they lived both as
  constants in climate.py and as a list in airconditioner.py. Declare them
  once in airconditioner.py (HREF_* + CLIMATE_CONSUMED_HREFS, which also builds
  the COVERAGE caps) and import them into climate.py, so a new sibling read
  can't drift out of sync with its coverage entry.
2026-07-21 23:59:03 +00:00
Marc Billow c0298d57d9 fix: normalize washer dosing-select codes; stop blocking the loop in diagnostics (#9)
Two fixes for issue #9 (WW90T634DHE washer):

- washer dosing selects: the four detergent/softener dosing selects read their
  current value from `<Prefix>LevelCtrl_<code>` (un-padded, e.g. "3") but their
  options from `Supported<Prefix>LevelCtrl_<hexpairs>` (zero-padded, e.g. "03").
  HA's SelectEntity renders a select "unknown" whenever current_option is not in
  options, so all four sat "unknown" (idle and running) even though every other
  select worked -- which is why it was only those four. Normalize the current
  value to the supported code with the same integer value so it matches an
  option (and its translation); convert back to the device's native un-padded
  format on write.

- diagnostics: pkg_version("smartthings-local") reads package metadata off disk
  (listdir + open + read_text), tripping HA's event-loop blocking-call detector.
  Offload it to the executor. Audited the rest of the package: config_flow's
  socket/crypto and every coordinator DTLS call are already offloaded via
  async_add_executor_job -- this was the only blocking call left on the loop.

Also documents air-conditioner support in the README (device table, capability
module list, platform list), missed when that support landed.

Updates the washer dosing tests to the corrected value/write format and adds a
current-option-is-a-valid-option regression; adds a diagnostics test asserting
the version lookup runs off the event loop.
2026-07-21 23:49:30 +00:00
themaanda 0503bda0f3 Detect WF-series washer models 2026-07-21 16:59:16 -05:00
themaanda 6f53b3043b Cover TP1X refrigerator native resource mirrors 2026-07-21 16:58:42 -05:00
Marc Billow 296535d0f2 feat: air conditioner support with a composite climate entity (#17)
Add support for Samsung room air conditioners (ARTIK051_PRAC-class), the
first device whose core controls map onto a single Home Assistant `climate`
entity rather than a scatter of switches/selects/numbers.

- New `climate` platform + `ClimateDesc`: one composite entity that reads
  power, HVAC mode, current/target temperature, fan (wind) strength, swing
  (wind direction) and the convenient-mode preset across several OCF
  resources and writes back to each. On/off folds into HVACMode.OFF /
  TURN_ON/OFF; convenient mode folds into preset_mode. The entity binds one
  primary resource (/mode/vs/0) and reads its siblings from the coordinator
  snapshot, reusing the cross-resource read pattern from number/select.
- New `airconditioner` capability module + by_type registry, routed via the
  `_PRAC_` modelNum token. Reuses common ALARMS/ENERGY_METER,
  fridge.FIRMWARE_UPDATE and dishwasher.DIAGNOSIS; air purify and auto clean
  as config switches; air dust filter status/usage as diagnostics (usage
  normalized to a percentage of rated capacity).
- Climate-consumed and all-zero/ambiguous resources (temperature/wind,
  /sensors, /humidity) are declared as AC-scoped coverage so every href in
  the dump binds or is covered -- no coverage-gap repair.
- Fan/swing modes map onto HA standard constants (auto-localized); the
  custom fan `turbo`, presets `quiet/smart/speed`, and the filter-status
  enum get translations in strings.json + translations/en.json.
- Scrubbed fixture, golden, and tests: registry routing, zero unbound
  hrefs, the climate write contract, and filter-% normalization.
2026-07-21 14:38:14 +00:00
Marc Billow febc8fa4a0 fix: keep energy sensors on empty-stub reps; gate power on field presence
Review follow-up. An explicit exists_fn bypasses entity._is_included's
empty-{} stub carve-out, so the sentinel-aware energy meter would drop
power_watts/energy_kwh when /device/0 returns a not-yet-fetched stub for
/energy/consumption/vs/0. Restore the carve-out (`not rep or ...`), and
hide power_watts when instantaneousPower is absent from a populated rep
(not just when it's the -500 sentinel) so a partial rep can't spawn a
phantom power sensor.
2026-07-21 01:39:49 +00:00
Marc Billow 9264b912f9 feat: full dryer support + consistent laundry capability surface
First full dryer dump (issue #14, DV90BB5245AES1) surfaced 5 unbound
hrefs and an "incomplete capability coverage" repair. Handle them and,
while here, make the washer/dryer/dishwasher families consistent instead
of each carrying a bespoke variant of the same controls.

Dryer coverage:
- /power/0, /kidslock/0, /remotectrl/0: bind via the OCF-native + vendor
  fallback pairs (prefer the standard OCF resource, fall back to -vs).
- /buzzersound/vs/0: new Buzzer sound select.
- /course/vs/0: cycle select shared with washer/dishwasher; ignore the
  /st/dryercourse/vs/0 re-encoding (mirror of /st/washercourse/vs/0).

Consistency / de-duplication:
- Move generic OCF controls (power/kids-lock/remote-control fallback
  pairs, energy meter) into common.py; every registry uses them.
- Move shared laundry controls (buzzer, job-beginning-status, and the
  /course/vs/0 cycle-select machinery) into laundry.py; washer and
  dishwasher stop hand-rolling their own copies.
- Energy meter is now sentinel-aware everywhere: the dead '-500'
  instantaneousPower reading no longer shows a misleading 0 W (fixes it
  on dryers and dishwashers, matching the earlier washer fix).
- Job-beginning-status reads x.com.samsung.da.currentStatus, the field
  every dump actually carries; the dryer sensor was previously blank.

Adds a scrubbed dryer fixture, golden, and capability tests, plus an
.claude/skills/adding-device-support skill capturing the dump-reading,
OCF-vs-vendor, entity-taxonomy, and coverage workflow. Bumps to 0.6.0.
2026-07-21 01:15:12 +00:00
Marc Billow 00c3ebaf75 feat: auto-detect DTLS port across the full 49152-49160 range
The config flow only probed 49154/49155, so appliances whose local
CoAP/DTLS API binds elsewhere in the ephemeral range (e.g. a dishwasher
answering on 49153) could never be added.

Add a fast UDP liveness sweep across 49152-49160 that uses the ICMP
port-unreachable / ECONNREFUSED asymmetry to find the live port(s)
before attempting the expensive DTLS handshake. Closed ports fall out
immediately; a live-but-silent port is kept as a candidate. The real
handshake then runs only against discovered ports, preferring the
historically known 49154/49155 when several look live.

Also drop the probe's /device/0 GET deadline from a bare 15s literal to
a named PROBE_GET_TIMEOUT_S constant (10s) — the slowest observed full
dump is ~8s, and 10s matches the per-resource read timeout used
elsewhere.

Bumps version to 0.5.0.
2026-07-20 21:52:35 +00:00
Marc Billow 91013ece60 fix: translate machine_state sensor values; bump to 0.4.1
machine_state was rendering the raw lowercase OCF values (idle/active/
pause) untranslated in the UI. Add device_class=enum, options, and a
translation_key matching the existing pattern used by ice_making_status
and connection_mode, in both the shared operational.py capability and
oven.py's separate machine_state sensor.

Bump patch version for this fix plus the ice_type 'off' translation and
iot_class correction earlier on this branch.
2026-07-19 04:33:23 +00:00
Marc Billow 795763f3ca fix: add missing ice_type 'off' state translation
The refrigerator fixture's x.com.samsung.da.iceType.supported list
includes "Off" alongside the whiskey_iceball_* values, but strings.json
only translated the whiskey_iceball options, leaving "Off" to render
untranslated in the ice-type select.
2026-07-19 04:18:59 +00:00
Marc Billow a7ed230569 fix: correct iot_class to local_push
Coordinator prefers CoAP OBSERVE push notifications (observe.py) over
polling when the device supports it, falling back to polling only when
observe mode isn't available or drops.
2026-07-19 04:11:01 +00:00
Marc Billow 5fbf58af30 chore: bump manifest version to 0.4.0 2026-07-18 18:26:58 +00:00
Marc Billow 35f76ce2df feat(washer): add label translations for detergent/softener dosing selects
Assumes the LevelCtrl code scheme is None/Low/Medium/High (00-03) on both
dispensers -- code 00 has no on-screen equivalent in the app's 3-choice
Faible/Moyen/Élevé picker, assumed to be what "Activation" off collapses
to -- and Level2Ctrl is Soft/Medium/Hard for detergent water hardness,
1x/2x/3x for softener concentration. detergent_quantity and
softener_quantity share one translation_key (same vocabulary), same
pattern as fridge.py's shared 'brightness_level' key.

Not cross-device verified: only one dump + screenshot set (issue #9) to go
on, and the softener concentration reading doesn't cleanly match its
screenshot (assumed to be a setting changed between dump and screenshots,
not a different code scheme -- see the comment in washer.py).
2026-07-18 18:24:10 +00:00
Marc Billow 2a6bbc9dfb fix(washer): stale idle progress%, add detergent/softener dosing entities (#9)
progress_percentage lacked the active-state gate already applied to
progress/cycle_active/finish_time, so it kept showing a stale device value
(e.g. 1%) while idle -- now zeroed the same way. Shared by dryer/dishwasher/
oven via operational.py's OPERATIONAL_STATE.

Also exposes detergent/softener auto-dispense quantity, water hardness/
concentration, and low-reservoir alarms from /course/vs/0's options array,
using the same decode/RMW helpers already used for course selection and
drum-clean tracking. Gated by exists_fn so washer models without these
fields (e.g. the existing test fixture) are unaffected.

Water consumption is unaffected -- common.WATER_METER is already wired
into the washer registry; this reporter's device just doesn't expose
/water/consumption/vs/0.
2026-07-18 18:15:41 +00:00
Marc Billow 37bd063c0a chore: bump manifest version to 0.3.0 2026-07-15 15:59:24 -05:00
Marc Billow e875266405 fix(washer,fridge,oven): correct energy/temperature-unit bugs from issues #6/#7
Washer (#6): instantaneousPower is a dead sentinel ('-500') on every
TP1-class washer dump collected so far, and cumulativePower is absent
outright on at least one model. WASHER_ENERGY_METER now hides both
sensors instead of showing a misleading "0 W"/perpetual "unavailable".

Fridge (#7): temperature sensors/setpoints hardcoded '°F', ignoring the
unit each device actually reports per-reading -- fixed via a new
unit_fn hook read live from the resource. Also corrects
DEFROST_BLOCK_STATUS's polarity (DEFROST_BLOCK_ON means actively
defrosting, not "blocked", confirmed against live dumps) and adds
REFRIGERATION_FALLBACK for /refrigeration/0, closing the last unbound
href surfaced by issue #7's diagnostic dump.

Oven: applies the same live-unit-reading fix defensively to
OVEN_SETPOINT, which shares the same aggregate resource shape.
2026-07-15 11:41:21 -05:00
Marc Billow e66f4fd2ff chore: bump manifest version to 0.2.1
Was left at 0.1.0 across the last two releases. Also de-hardcode the
diagnostics test's expected version so this doesn't happen again --
it now reads manifest.json directly instead of a copy-pasted literal.
2026-07-11 20:26:52 -05:00
Marc Billow dd541b19a1 feat(washer): expose Drum Clean+ maintenance status
Adds cycles-until-due and last-cleaned sensors decoded from the same
options[] array the course selector already reads (DrumCleanProposal_N -
WashingTimes_N for cycles remaining, DrumCleanLog_<iso> for last-cleaned),
verified byte-for-byte against a live app screenshot ("Potreba cistenia po
37 cykloch" / "Naposledy cistene pred 10 dnami").
2026-07-11 20:18:28 -05:00
Marc Billow 211cf74296 feat(washer,dishwasher): live per-device cycle selector, localized names
Course selection is now a writable select entity sourced from each
device's own x.com.samsung.da.editCourseList (via a new options-as-callable
form on SelectDesc, reading the coordinator's full resource snapshot
instead of just the entity's own href), rather than a hardcoded course
table baked into Python. A MostUsed_ field on the same resource was
considered as a fallback but rejected after byte-level analysis showed it
doesn't reliably encode a course list. When a device never populates
editCourseList, the selector isn't created at all (exists_fn now takes
(rep, resources) to check a sibling href, matching the existing
match_fn(rep, resources) pattern).

Display names moved out of Python into strings.json/translations under
entity.select.{washer,dishwasher}_cycle.state.*, matching this
integration's existing translation_key convention (fridge.py's ice_type,
flex_zone_mode, etc.) instead of hardcoding English names in code.
2026-07-11 20:00:12 -05:00
Marc Billow 29b9e36699 fix(washer): ignore remaining unbound hrefs (cycleinterface, drlc, operational/state OCF-native)
discover() flagged /cycleinterface/vs/0, /drlc/0, and /operational/state/0
as unbound on real washer dumps, which would surface a spurious device
coverage gap for washer owners. All three are noise: cycleinterface is
empty on every dump seen, drlc/0 is an OCF-native duplicate of the
already-ignored /drlc/vs/0, and operational/state/0 is a read-only
OCF-native duplicate of /operational/state/vs/0 (already modeled by the
richer, write-capable operational.OPERATIONAL_STATE).
2026-07-11 13:30:00 -05:00
Marc Billow 22c5295d18 feat(washer): wire model-number fallback into discovery and config flow 2026-07-11 12:53:57 -05:00
Marc Billow 2852a21c4a feat(washer): add model-number-based device-type detection fallback 2026-07-11 12:49:08 -05:00