Compare commits

...
Author SHA1 Message Date
Marc Billow 03958dd994 Merge pull request #184 from mbillow/claude/issue-triage-429jtb
Issue triage: absence/motion AC sensors (#173), microwave reminders (#181), Python 3.13 pin
2026-07-28 22:37:55 -05:00
Marc Billow a7aea3764b feat(airconditioner): make absence/motion-detect enable switches writable
status on both /mds/absencepowersaving/vs/0 and
/option/motiondetectwind/stateful/vs/0 is a bare On/Off boolean, the same
shape already shipped writable elsewhere in this file (MUTE_ONCE,
AUTO_CLEAN, AIR_PURIFY) without a live-confirmed write either -- worst
case a wrong token no-ops. The paired mode selects (switchPowerSaveMode,
motion-detect modes) stay read-only: their behavioral effect on live HVAC
isn't inferable from the dump, same reasoning as ANOMALY_LOAD's mode field.
2026-07-29 03:34:18 +00:00
Marc Billow a6eb1c62d4 feat(microwave): add filter reminder / end signal reminder switches (#181)
Both FilterRemind_*/RemindBeep_* option-array tokens are already
present -- and both On and Off already confirmed -- on the existing
ME7500D fixtures (issue #152), so this is a straight sibling of the
Sound/Lamp switches rather than new discovery work. Gated with
exists_fn like Lamp since the MW7300B combi dump has neither token.

Doesn't address the rest of issue #181 (power-level slider,
non-reported cooking modes, 3-level light, child lock, send-to-
microwave) -- those need write-contract confirmation this dump
doesn't carry.
2026-07-29 02:55:47 +00:00
Marc Billow 90d79f117a build: pin minimum Python to 3.13 in pyproject.toml
README.md and requirements-dev.txt already document that the test
harness needs Python 3.13+ (pytest-homeassistant-custom-component
doesn't resolve below it), but only in prose. Add requires-python so
pip fails fast with a clear message on an older interpreter instead of
a wall of "Requires-Python >=3.13" version-list noise.
2026-07-29 02:52:38 +00:00
Marc Billow 2b24152276 feat(registry): cover absence-power-saving and motion-detect-wind on AC (#173)
Lennox-branded heat pump on the Samsung RAC board family (modelNum
TP1X_LNX-AC-RAC-01001_0000) already routes correctly via the existing
'-RAC-' token, but its dump has two resources no prior AC fixture
carried: /mds/absencepowersaving/vs/0 and
/option/motiondetectwind/stateful/vs/0. Bind both as read-only
sensors, matching the CURRENT_LIMIT/ANOMALY_LOAD precedent -- nothing
in the dump confirms write safety on live HVAC hardware.
2026-07-29 02:52:33 +00:00
Marc Billow 6f21699c37 Merge pull request #182 from mbillow/claude/device-detection-simplify-58rvo5
Simplify device-type detection: token table in, oneUiVersion out
2026-07-28 21:28:49 -05:00
Marc Billow 40c7033b1b docs(readme): update device-type routing and test setup
Three things this branch left stale.

"Adding a new appliance type" step 4 told contributors to key the registry
on the lowercased suffix of oneUiVersion and pointed at _type_key() for the
transform. Neither exists any more, and oneUiVersion no longer routes at
all. Describe the board-token table instead, including the two rules that
keep it a table: whole-token matching covers every delimiter spelling, and
an entry must name the specific device type rather than the board family
that contains it.

The repo-layout line for identity.py said "Reads device identity for type
detection". It has never fed type detection -- it reads /oic/p and /oic/d
for the HA device registry, and now also carries OCF's device-type
declaration into diagnostics.

The test setup installed pytest-homeassistant-custom-component and
homeassistant unpinned on top of requirements-dev.txt, which already pulls
both in at matching versions, and used whatever `python3` resolves to. On
3.12 or older nothing resolves and the install fails outright with a wall of
version-conflict output that doesn't name the real cause. Say 3.13+, drop
the redundant install, and note CI runs 3.14.
2026-07-29 02:27:00 +00:00
Marc Billow c9620b47b3 fix(diagnostics): redact the OCF device name; log description on unknown type
Two things a review of this branch turned up.

/oic/d's `n` is free text the owner sets from the SmartThings app, so it may
carry a person's name. Nothing in the /device/0 dump has ever exposed it --
it only became reachable when diagnostics started reporting /oic/d earlier
in this branch, which would have started carrying it into public issue
reports. Redact it. `rt`, the device-type signal the block exists for, is
untouched, and no /device/0 resource uses a bare 'n' key, so nothing else
changes.

The unknown-device-type warning logged only modelNum. That line is what a
user pastes into an issue, and modelNum alone can't identify a washer from a
dryer -- both report the shared DA_WM_ laundry board, and detection reads
the consumer-model code out of `description` for exactly that reason. Log
both fields.
2026-07-29 02:20:37 +00:00
Marc Billow cafd7d5afa refactor(registry): drop oneUiVersion from device-type detection
oneUiVersion looks like the signal you'd want -- the device naming its own
type, '7.0 Dishwasher' -- and it was the first thing detection consulted. It
never earned the position:

- Only 7 of 49 fixtures report it at all.
- All 7 resolve to the same registry from their modelNum board token alone.
- No device-support issue has ever been fixed by adding a mapping for it.
  Every one went through modelNum. The alias keys it needed in
  _REGISTRY_BY_KEY ('airpurifier', 'air_conditioner', 'hood') were
  speculative when the registries were first written and never used since.

So it bought a key-normalizing helper (_type_key), a lookup with a suffix
fallback (for_device), three alias keys, and a second config-flow step whose
only reason to exist was phrasing a sentence about oneUiVersion -- for a
signal that has never once been decisive.

Remove it from detection. It stays in diagnostics, where it's genuinely
useful: it names the firmware generation ('7.0 Air conditioner' is Tizen
Lite), which matters when triaging an issue.

Detection order was also duplicated in four places -- the coordinator, the
config flow's probe, the golden-regression harness, and the skill -- which
is how the harness and the shipped order drift apart. Collapse it into
by_type.resolve(resources), and call that everywhere.

The two "appliance type not recognized" config steps become one. They
differed only in whether they blamed a missing oneUiVersion, which is not a
distinction a user can act on, and never was.

Verified by the full suite (795 passing), including every golden regression
-- so entity output is byte-identical for all 49 device fixtures.

TestOneUiVersionIsNotConsulted locks in the premise rather than just the
outcome: for every dump that reports a oneUiVersion, the model strings alone
must still reach a registry. If a future device breaks that, the test says
so instead of the device silently losing half its entities.

Also note in requirements-dev.txt that Python 3.13 resolves the pinned
harness floor -- 3.12 and older resolve nothing and fail the whole install.
2026-07-29 02:14:13 +00:00
Marc Billow a863df1e59 refactor(registry): match board families by token table, not substring ladder
for_device_by_model() had grown to 21 sequential `if key is None` branches
and 102 comment lines against 59 lines of code -- 33 of the repo's 243
commits have touched this file. Most of that bulk came from one wrong
primitive: substring matching on a delimited string.

Samsung spells the same board family with either delimiter, so '_RAC_' and
'-RAC-' each needed their own rule, and 'ARTIK051_DONGLE_REF' (issues #77,
#83) matched no '_TOKEN_' spelling at all because REF lands at the end of
the pipe-prefix with no trailing underscore -- which is what
_model_num_segments() existed to work around. Which field a rule searched
(modelNum, or modelNum + description) was historical accident. Collisions
like WAC vs WA were resolved by one `if` physically preceding another,
invisible in the code and explained at length in prose.

Tokenize on any non-alphanumeric run, upper-case, and look the tokens up in
a flat table. Every delimiter spelling collapses to one entry, both fields
go through the same matcher in a documented order (modelNum, then
description, then the fuzzy consumer prefix), and specificity is a property
of the table rather than of line ordering.

Two behaviours are preserved deliberately:

- modelNum is matched before description, which is what keeps the legacy
  gas cooktop correct: it reports 'ARTIK051_GB_CT_001' (CT) alongside
  'ARTIK051_GLOBAL_COOKTOP' (COOKTOP, which otherwise means induction).
  It is the only known device whose two fields disagree.
- _consumer_model_key still splits on '_' only. Widening it to '-' would
  read the dishwasher's 'ADW-WW-RTL-24-AILITE' board segment as a bare 'WW'
  washer.

Verified identical: all 49 device fixtures resolve to the same registry
before and after, and every existing for_device_by_model test case passes
unchanged. The table also picks up two families that previously depended on
oneUiVersion alone (TP1X_DA-AC-AIR air purifiers, ADW dishwashers), so they
now survive firmware that omits it.

TestBoardTokenAmbiguity guards the one property the flat lookup needs --
that no real model string contains two tokens naming different device types
-- across the whole fixture corpus, so a newly added dump exercises it
automatically.

The skill gains a section on routing: what each detection stage is for, the
rules for adding a token (name the specific type, never the board family;
never add a delimiter spelling; two-letter tokens are a last resort), when
to reach for the consumer prefix or a resource signature instead, and the
measured stake -- an unrouted device loses roughly half its entities.
2026-07-29 01:57:10 +00:00
Marc Billow 288ba02cc5 feat(diagnostics): capture /oic/p and /oic/d identity
Device-type detection currently parses board part numbers out of
/information/vs/0's modelNum. OCF has a standard field for exactly this
question -- /oic/d's `rt` -- and read_identity() already fetches the
resource, but kept only `n` and threw the rest away. No captured dump has
ever included it either: /device/0 batch responses don't carry /oic/d, and
diagnostics didn't report it, so there's no evidence on whether real
hardware populates it usefully.

Keep `rt` as DeviceIdentity.device_types, keep both raw payloads whole
(we don't yet know which of their fields identify a type), and surface
them in diagnostics so incoming issue reports answer the question.

Nothing routes on it yet.

/oic/d and /oic/p identify the unit with bare two-letter keys -- 'di' and
'pi' -- as sensitive as the serial number redact.py already covers but far
too short to match on: 'di' alone is a substring of 'condition', 'display'
and 'dispenser'. Add a whole-key match alongside the substring rules.
2026-07-29 01:56:52 +00:00
Marc Billow 668aec401a Merge pull request #174 from firstof9/fix/microwave-issue-172 2026-07-28 17:57:45 -05:00
firstof9@gmail.com 1f331f3aa6 fix(registry): route microwaves without /information/vs/0 to microwave registry (#172)
Issue #172: Samsung Microwave units (ME8000T-/AA0) omit /information/vs/0 and have empty oneUiVersion, falling back to unknown device type. Route via /oven/vs/0 and MicroWave modes in supportedModes.
2026-07-28 13:29:57 -07:00
Marc Billow 498da49817 Merge pull request #171 from mbillow/claude/issue-triage-gating-gf6bg4
Fix unsound gating from #170, cover remaining fan-speed icons
2026-07-28 14:10:22 -05:00
Marc Billow bbf3f3f833 Revert unsound air-quality gating from #170, cover remaining fan-speed icons
An Opus review of merged PR #170 found the cleanLevel-scalar existence
gate on AIR_QUALITY doesn't hold up as a general rule: three fixtures
in this repo (air_purifier_device.json, air_purifier_vtww_device.json,
range_hood_device.json) carry genuinely populated Dust/FineDust/
SuperFineDust readings with no such scalar, so requiring it risks
silently dropping real air-quality readings on AC hardware this repo
hasn't seen yet. Reverted _has_sensor_type to item-type presence only
(as before #170) and moved the #166 fix to enabled_default=False on
all five entities instead -- same conservative, non-existence-gated
treatment already used for tropical_night_mode and the fridge/cooktop
precedents it was modeled on. Golden fixtures and tests updated to
match; the five sensors are bound-but-disabled on windfree/#17-style
boards again rather than unbound.

Also added icons for the AC fan_mode values #170 missed -- the raw
numeric labels ("1".."5") that TP1X_DA-AC-RAC-01001 and the window-AC
board report instead of turbo/max -- and swapped the whole fan-speed
icon family to mdi:fan-speed-1/2/3 for a more purpose-built look than
the generic speedometer, applied consistently to both the AC climate
card and the air purifier fan. Fixed motiondirect/motionindirect to
match core's smartthings integration's arrow pairing (previously
inverted).

Known limitation, not fixed here: enabled_default only affects newly
registered entities. Anyone who already has tropical_night_mode or the
five air-quality sensors enabled from #164 (a narrow window before
this fix, but real) won't see them auto-disable -- they'd need to
disable them by hand in Settings > Devices > Entities. A real fix
needs a one-time entity-registry migration, which this integration has
no existing infrastructure or test coverage for; scoping that felt
like its own follow-up rather than something to bolt on here.
2026-07-28 19:07:59 +00:00
Marc Billow 91b129282b Bump version to 0.15.0 2026-07-28 18:56:07 +00:00
Marc Billow 34fe991858 Merge pull request #170 from mbillow/claude/issue-triage-gating-gf6bg4
Fix AC entity gating from #164, add missing preset/mode icons (#166, #169)
2026-07-28 13:50:53 -05:00
Marc Billow 6d185e4e3d Match WindFree icon to the official smartthings integration's choice
HA core's bundled smartthings integration (the cloud counterpart to
this same Samsung AC feature set) uses mdi:weather-dust for its
wind_free preset rather than a generic windy icon -- a better fit for
a feature about avoiding direct airflow, not blowing harder. Match it
for both the AC climate preset and the air purifier fan preset.
2026-07-28 18:47:10 +00:00
Marc Billow 5f47fc0477 Add per-state icons for the remaining entities that render with none
HA only consults icon-translation state icons when the entity has no
static icon of its own (Entity.icon, if set, always wins -- see
homeassistant.helpers.entity's state_attributes construction). Audited
every entity with a labelled state/state_attributes catalog in
translations/en.json against its descriptor's icon= setting: every
select (cycles, courses, brightness levels, ...) and most sensors
already carry a fixed icon in code, so per-state icons there would be
silently shadowed. The three that don't -- air_purifier_fan's
preset_mode, machine_state, and connection_mode -- get one per value
here.
2026-07-28 18:31:31 +00:00
Marc Billow cfa82e8853 Add icons for AC preset/fan modes not covered by HA's built-ins (#169)
HA's core climate component already ships default icons for common
preset_mode/fan_mode values (eco, away, sleep, auto, low/medium/high,
...), but this integration's own values -- WindFree (nano/nanosleep),
Quiet, Smart, Speed, Long wind, the motion-aware direct/indirect
presets, Dry comfort, 2-Step, and the turbo/max fan speeds some boards
report -- fall outside that vocabulary and rendered with the generic
circle-dot fallback (the icon the #169 screenshot is missing). Adds
icons.json with an icon per value, mirroring the state-label catalog
these same values already have in translations/en.json.
2026-07-28 18:20:10 +00:00
Marc Billow 739881de16 Gate AC tropical night mode and air-quality sensors on real capability signals (#166)
Issue #166 (ARxxTXFCAWKNEU, board ARTIK051_PRAC_20K) reported tropical
night mode, clean level, dust, fine dust, odor, and super fine dust
entities showing up even though the reporter's units have no such
physical features. All six were added in #164.

The Sleep_<N> options token backing tropical_night_mode is present in
every AC dump on record regardless of confirmed reality, so there's no
usable signal at boot time -- it's now registered but disabled by
default (matching the precedent already set by fridge.rack_count /
cooktop.paired_hood_model), letting units that do have it opt in.

/sensors/vs/0's item-type list has the same problem (all five types
always listed, permanently zero on this board), but there turned out
to be a real tell: a top-level x.com.samsung.da.cleanLevel scalar is
present only alongside genuinely populated readings on every dump on
record (tp1x_da_ac_rac_01011, the tp1x_da_ac_air air purifier fixture)
and absent on every all-zero ARTIK051_PRAC_20K dump, including both
#166 units and the original windfree/#17 fixtures this capability was
first verified against -- which, per their /information/vs/0, turn out
to be the same board revision as #166's units, so that "verification"
never actually proved a real sensor either. AIR_QUALITY's exists_fn now
requires that scalar, and the windfree/airconditioner golden fixtures
are updated to match (those five entities no longer bind there).
2026-07-28 18:12:02 +00:00
Marc Billow 6080d37f7d Merge pull request #167 from mbillow/claude/issue-triage-138-latest-y90g78
Issue triage batch: oven/AC/microwave/air-dresser fixes, 4 new device types
2026-07-28 10:21:28 -05:00
Marc Billow 71e026b804 Fix hot/warm href tiers dropped for no-entity coverage capabilities
discover() only emitted a BoundEntity per capability *entity*, so a
coverage-only Capability (entities=(), used to mark a href as handled
elsewhere -- e.g. the AC climate card's wind/strength, wind/direction,
temperature/control hrefs) produced zero rows. The coordinator computed
its hot/warm href lists by walking `bound`, so every such href's
poll_tier was silently discarded and it fell back to the ~30s summary
poll only -- no sub-poll cadence and never attempted for OCF OBSERVE.

This is the root cause of issue #166's "up to a minute" lag for
remote-driven fan-speed changes: /wind/strength/vs/0 carries poll_tier
'warm' via airconditioner.COVERAGE but never reached
_hot_hrefs/_warm_hrefs, so it wasn't in the OBSERVE-attempt href list
and only refreshed on the summary poll.

discover() now takes an optional tier_log(href, poll_tier) callback
fired for every href a capability matches, entities or not. The
coordinator uses it directly instead of deriving tiers from `bound`.
2026-07-28 15:08:12 +00:00
Marc Billow 65b0326d62 Merge remote-tracking branch 'origin/main' into claude/issue-triage-138-latest-y90g78
# Conflicts:
#	tests/test_airconditioner_capabilities.py
2026-07-28 14:51:29 +00:00
Marc Billow 6007505e6b Stop surfacing '_OFF'-suffixed placeholder alarm codes (#166)
Samsung pre-populates /alarms/vs/0 with one row per supported alarm type,
each carrying a '<Name>_OFF' placeholder code (no 'Deleted' state at all)
when that alarm isn't firing. common._active_alarm_codes only ever
filtered on 'Deleted' state, so every device using this shared capability
(including the AC family) showed these inert placeholders --
'ErrorCode_OFF', 'FilterAlarm_OFF' -- as if they were live alarms.

Confirmed the '_OFF' suffix convention holds across every alarm code seen
in this repo's fixtures so far (ErrorCode_OFF, FilterAlarm_OFF, OV_E_OFF,
CT_E_OFF, WaterTankFull_OFF, AC_V_0002_OFF, all placeholders; DoorA_Opened,
FilterAlarm, SNSF_Reached, all genuinely active with no suffix) -- issue
#166's own dump has both a FilterAlarm_OFF placeholder and, on a second
unit, a live FilterAlarm/state=Created alert, which is what motivated
generalizing range_hood.py's existing (but narrower, ErrorCode_OFF-only)
special case into the shared helper instead of duplicating it further.

The other three points in #166 (filter-usage percentage vs. filterStatus
disagreement, an "air purification" config toggle the reporter says has no
physical effect, a "beep on/off" control) don't have a confirmed code fix:
the percentage math already matches the device's own filterUsage/
filterCapacity fields (filterStatus is a separate device-computed field we
already relay verbatim, not something we derive), the air-purify resource
is correctly wired to what the board reports and its absence from the
official app's own options list suggests an inert shared-board-profile stub
rather than an integration bug, and a "Beep volume" NumberDesc keyed off
the same Volume_100 option both dumps report already exists (0 mutes it).
2026-07-28 14:43:21 +00:00
Marc Billow 5a73a25005 Address independent code review findings on PR #167
Two real bugs, both latent (no shipped fixture exercised them), plus a
consistency gap and a couple of correctness/DRY nits flagged by review:

- async_set_fan_mode resolved a fan_mode label against the static
  _FAN_TO_DEVICE reverse map before checking whether the resulting code is
  actually one of the unit's own supportedModes. A board using non-standard
  wind-strength codes while still spelling a standard-looking label in
  modesName (e.g. codes "31"-"33" named "Low"/"High"/"Turbo") would silently
  write a code ("1"/"3"/"4") the device never advertised. Now validates the
  static hit against the unit's own supported codes before trusting it,
  falling through to the live modesName scan otherwise.

- air_purifier.WIND_STRENGTH_FAN reused key='fan', the same key as FAN in
  the same registry -- BoundEntity's unique_id is built from key alone, not
  href, so a board reporting both hrefs would have one fan entity silently
  shadow the other. Renamed to 'wind_strength_fan' (translation_key
  unchanged). No shipped fixture reports both hrefs today, but the two caps
  living in the same registry made this a real latent hazard, the exact one
  AIRFLOW_GENERIC's own comment already documents and deliberately avoids.

- microwave.py's cooking_mode select still used a static, union-of-all-
  dumps mode list, even though both shipped microwave fixtures already
  report x.com.samsung.da.supportedModes on /mode/vs/0 -- the same shape
  oven._oven_mode_options was just built to prefer over exactly this kind
  of static list (issue #138's follow-up, this same PR's skill update).
  ME7500D advertises 4 modes; the select was offering 11. Applied the same
  live-first, static-fallback pattern.

- Added the issue #152 fixture the microwave lamp fix was missing (the
  SKILL.md step this PR itself added asks for one).

- climate.py's _legacy_airflow rebuilt a 2-key presence dict from
  coordinator.resource()'s truthiness, which collapses "href absent" and
  "href present with an empty {} rep" to the same falsy value -- while
  is_legacy_board (and discover()'s own binding) test key membership, not
  truthiness. Simplified to pass last_resources through directly, matching
  is_legacy_board's actual contract instead of a cheaper approximation of
  it, so the "can never disagree" claim in both docstrings is actually true.

- Hoisted the 'power' payload branch duplicated verbatim across
  _airflow_fan_write/_fan_write/_wind_strength_fan_write into one
  _power_write helper (registry/capabilities/air_purifier.py).

- Removed two now-unused imports (test_air_dresser_capabilities.py,
  test_air_purifier_vtww_fan.py) and replaced a tautological
  code-in-_DEVICE_TO_FAN check with one that actually exercises the live
  climate entity's fan_modes/fan_mode (test_climate_ac_modes.py).

- Fixed a pre-existing (not from this PR) no-op test on main --
  test_registry_reproduces_golden_state_keys_for_induction_cooktop computed
  golden/state_keys and never asserted on them.

756 tests pass.
2026-07-28 14:37:32 +00:00
Marc Billow dc3e1255d1 Ignore fridge /rm/control/vs/0 plumbing href (#165)
TP1X_REF_21K's EU region variant reports a bare resource-monitoring
poll-interval config (minPeriod in ms) the US variant doesn't -- the only
unbound href keeping the coverage-gap repair open. Door sensors, the
reporter's actual ask, were already covered generically by
fridge.DOOR_GENERIC/DOORS_FALLACK.
2026-07-28 14:27:15 +00:00
Marc Billow daa7546208 Add device support for Wind-Free 2-in-1 AC TP2X_FAC_BORA_21K (#150, #153)
This board (a floor-standing + wall-mounted indoor unit pair sharing one
outdoor unit and one local IP) reports no oneUiVersion and carries the
'_FAC_' modelNum token, which no existing routing rule matched -- it fell
back to 'unknown' and exposed nothing but a power switch, with no climate
entity generated at all (both issues' reported symptom).

Once routed to the existing airconditioner registry, it binds cleanly
against the exact same CLIMATE composite every other room-AC family uses --
same Cool/Dry/Wind/AIComfort mode vocabulary, same wind-strength/humidity/
filter/energy resource shapes already modeled. Only two hrefs are unique to
this board: /subdevices/vs/0 (an opaque paired-subdevice id list -- issue
#150 asked whether the second indoor unit can be controlled separately;
it can't through this or any other resource in the dump, the same
"remote device ids, not locally actionable" role as the existing
/remotedeviceinfo/vs/0 ignore) and /runn/vs/0 (a single undocumented int
with no supported-values list to interpret). Both added to _AC_IGNORED
rather than guessed at.
2026-07-28 14:09:21 +00:00
Marc Billow e568145deb Fix microwave lamp switch reading/writing the wrong tokens (#152)
The lamp SwitchDesc was modeled on issue #137's dump, which only ever
showed 'Lamp_Off' -- 'On' was never actually confirmed as the paired
value. Issue #152's ME7500D dump (same TP1X_DA-KS-MICROWAVE-01051 family)
is the first to report a real non-Off value, and it's 'Lamp_High' (a
brightness level), not 'Lamp_On'. So the switch always read as off
regardless of the device's real state, and toggling it on wrote a token
('On') the device has never been observed to accept -- matching the
reported "light control does not have any effect."

value_fn now treats any non-Off/non-absent value as on; write_fn now
writes back 'High'/'Off', the two tokens actually confirmed live, instead
of the never-confirmed 'On'.

The reporter's suspicion about the fan is unconfirmed and this dump's own
/hood/fanspeed/vs/0 shape already matches the no-separate-power case
fan.py's LocalThingsRangeHoodFan handles correctly (issues #137/#142), so
no fan change was needed here. A second dump attached in a comment on this
issue (model ME8000T, a large combi wall-oven with a very different mode
vocabulary) reports its own distinct gap and doesn't resolve to any known
device type at all -- that's a separate, substantial device-support task
left for its own follow-up rather than folded into this fix.
2026-07-28 14:03:56 +00:00
Marc Billow fcd34f73e5 Add device support for BESPOKE Cube Air A-VTWW-TP2-21-COMMON (#151)
This board reports no oneUiVersion and no modelNum token any existing
family routed on, so it fell back to unknown -- exposing nothing but power
even though most of its resources (air quality sensors, HEPA filter,
device-active, diagnosis, plumbing hrefs) are already handled generically
by the existing air_purifier registry via the '-VTWW-' modelNum fallback.

The one genuinely new piece is its fan: this board reports wind strength as
numeric codes ("87"/"89"/"90"/"91") on /wind/strength/vs/0 with a separate
modesName array ("SMART"/"MAX"/"WINDFREE"/"Sleep") giving the actual names,
unlike the existing TP1X_DA-AC-AIR family where supportedModes IS the name
list already. Generalized LocalThingsAirPurifierFan to resolve a mode code
through modesName when present (same live-label pattern as climate.py's AC
wind-strength fix, issue #155) instead of adding a second hardcoded fan
class, and added WIND_STRENGTH_FAN reusing the same 'air_purifier_fan'
translation catalog -- both board generations land on the identical
smart/max/windfree/sleep vocabulary already labelled there.

/mode/convenient/vs/0 is empty on this dump and added to COVERAGE alongside
the existing plumbing hrefs this board also shares with the TP1X_DA-AC-AIR
family.
2026-07-28 13:58:08 +00:00
Marc Billow a3d9cce164 Extend AirDresser support to DA_DF_TP2_20_COMMON (#157)
A different board generation from issue #162's DA_DF_A51_20_COMMON, also
carrying the '_DF_' modelNum token and so already routed into the
air_dresser registry -- but reporting two resources #162's board doesn't:

  /st/airdressercourse/vs/0 -- the course table id (Table_00), read the
    same way washer/dryer read /st/washercourse|dryercourse/vs/0. Wired up
    as AIR_DRESSER_COURSE's table_href and added to the global ignore list,
    mirroring that existing pair exactly.
  /airdresseroption/sanitize/vs/0 -- a genuine on/off setting (not covered
    by any existing capability), added as AIR_DRESSER_SANITIZE.

Introducing table_href means the course select's translation_key is now
always the table-lookup callable, so the bare 'air_dresser_cycle' catalog
entry added for #162 (only ever used when no table_href was passed) is
unreachable in every case and is removed -- both boards fall back to the
shared 'cycle' entry until their course tables get named, same as
washer/dryer's own precedent for an unrecognized table.
2026-07-28 13:50:59 +00:00
Marc Billow defeffd58d Merge pull request #164 from mbillow/pr-129-ac-additive-entities
Add beep, tropical night mode, filter hours/threshold, and air-quality entities for AC
2026-07-28 08:46:06 -05:00
Marc Billow 053e15bba6 Add device support for Samsung AirDresser DA_DF_A51_20_COMMON (#162)
This board reports no oneUiVersion and no modelNum token any existing
family routed on, so it fell back to the global unknown-device CAPABILITIES
set -- exposing only power/child-lock/start-stop-pause/delay/energy/machine
state, with /course/vs/0, /diagnosis/vs/0, and /washer/vs/0 all unbound and
no course/mode select at all (the actual reported gap).

Every one of those resources turns out to already be handled by the shared
laundry machinery: /diagnosis/vs/0 reuses dishwasher.DIAGNOSIS, and
/course/vs/0's cycle select works unmodified through laundry.cycle_options'
existing supportedOptions fallback (this board has no /wm/editcourse/vs/0
at all, so editCourseList never populates). /washer/vs/0 gets a new minimal
AIR_DRESSER_SETTINGS capability (wrinkle_prevent only) rather than reusing
dryer.DRYER_SETTINGS wholesale, since this device never reports
dryLevel/dryTime/dryerType at all and binding them would ship three
permanently-unavailable sensors.

Course codes aren't identified yet (no code->name mapping was reported), so
they render as their raw codes until named in translations, same as
dryer.py's precedent for unidentified codes.
2026-07-28 13:45:49 +00:00
Marc Billow aa9cdd83b7 Read AC fan speeds from the device's own modesName, not just 0-4 (#155)
TP1X_DA-AC-RAC-01001_0000 (model AR07C9150HZN) reports /wind/strength/vs/0
supportedModes as "0"/"31"-"35" instead of the "0"-"4" scale climate.py's
_DEVICE_TO_FAN was built from. Only "0" matched, so fan_mode/fan_modes
silently dropped every speed but Auto -- exactly the reported symptom.

Rather than hardcoding a second numeric scale, codes _DEVICE_TO_FAN doesn't
cover now fall back to the device's own modesName label (parallel-indexed
with supportedModes), mirroring how preset_mode already resolves dynamically
off a device's own supportedModes instead of a per-model table. Boards using
the standard 0-4 scale are unaffected -- _DEVICE_TO_FAN is still tried
first, so existing auto/low/medium/high/turbo labels don't change.
2026-07-28 13:38:42 +00:00
Marc Billow 57e06c5ccb De-duplicate the legacy ARTIK051 AC board-generation test (#161)
capabilities/airconditioner.py's is_legacy_board() (renamed from the
private _is_legacy_board -- it's now a cross-module helper) and
climate.py's _legacy_airflow() implemented the same "does this board have
/airflow/vs/0 but no /wind/strength/vs/0" test independently, one via
literal href strings and the other via coordinator.resource() truthiness.
is_legacy_board() now uses the module's own HREF_AIRFLOW/HREF_WIND_STRENGTH
constants, and _legacy_airflow() delegates to it via a minimal two-key
presence dict (cheaper than a full last_resources snapshot copy) instead of
re-implementing the check, so the token entities and the climate card's
legacy read/write paths can't drift apart on which board generation is in
play.
2026-07-28 13:31:37 +00:00
Marc Billow 5c962801b4 Fix _tropical_night_value, which had the same stale _option_token assumption
Same issue as the beep fix in the previous commit: this also assumed
_option_token returned the full 'Sleep_<N>' token and tried to split
off the prefix itself. With the canonical value-half _option_token,
that always returned None. Read the value directly instead.
2026-07-28 13:29:49 +00:00
Marc Billow c8597532b0 Stop collapsing a genuine fivepercentHumidity=0 reading to unknown (#160)
#146's zero-as-"not measuring" carve-out was meant for ARTIK051 boards'
plain x.com.samsung.da.humidity field, which only populates while Air
monitoring is briefly on and zeroes out afterward. It was accidentally
applied to fivepercentHumidity too, which every other AC board relies on
and which has never been documented getting stuck at zero -- so a real 0%
reading on those boards silently became "unknown". Only the humidity
fallback field now collapses 0; fivepercentHumidity passes 0 through as a
real reading.
2026-07-28 13:28:46 +00:00
Marc Billow 00c1d78373 Merge main into ac-additive-entities, resolve conflicts with #146
Both PRs independently modeled the same /mode/vs/0 Volume_*/Sleep_*
option tokens: #129 as beep/tropical_night_mode, #146 (already merged)
as buzzer_volume/good_sleep gated to the legacy ARTIK051 board
generation. They also each defined a helper named _option_token with
different return semantics (full token vs. value half) in
non-overlapping parts of the file, so git didn't flag it as a
conflict even though the second definition silently shadowed the
first.

Keep a single _option_token (value-half, the one already used by
buzzer_volume/good_sleep/spi/etc.), adjust beep's read/write to that
convention, and gate beep/tropical_night_mode off the legacy board so
they don't duplicate buzzer_volume/good_sleep on ARTIK051_KRAC-class
devices. Added a regression test locking in the gate.
2026-07-28 13:28:20 +00:00
Marc Billow 1cdad7f84c Read oven cook modes live from the device instead of a hardcoded list
Follow-up to the issue #138 fix: rather than hand-adding
ConvectionRoast/KeepWarm/BreadProof/AirFryer/Dehydrate/SelfClean/SteamClean
to oven._OVEN_MODES, read them from the device's own /mode/vs/0
supportedModes when it reports one, falling back to the static
NV7000BS-era guess only when it doesn't. Matches the adding-device-support
skill's preference for device-reported option lists over hardcoded ones,
and the SelectDesc's write validation now checks the same live list it
displays instead of a separate static tuple.
2026-07-28 13:26:41 +00:00
Marc Billow 1fb27c30ae Skill: call out preferring dynamic select options over hardcoded lists
Prompted by issue #138's fix, which extended oven._OVEN_MODES with newly
confirmed modes instead of reading them from the device's own
supportedModes field via options_field -- the pattern laundry.py already
uses for buzzer/finish sound. Document that preference so future
device-support work reaches for options_field/a callable first and treats
a static tuple as a last resort, not the default.
2026-07-28 13:18:46 +00:00
Marc Billow 123455a873 Add missing oven cook modes for NE63A6511SS/AA range (issue #138)
The range/oven-combo device in issue #138 (NE63A6511SS/AA, no
/information/vs/0) already resolves cleanly to the range registry via the
issue #74 for_device_by_resources fallback, with zero unbound hrefs -- the
reporter was just on an older release (0.11.1) predating that fix.

However its /mode/vs/0 supportedModes advertises ConvectionRoast, KeepWarm,
BreadProof, AirFryer, Dehydrate, SelfClean, and SteamClean, none of which
were in oven._OVEN_MODES. Since range.py reuses oven.OVEN_MODE's SelectDesc
wholesale, those modes were silently rejected by the mode select's write
validation and missing from its options. Extend the confirmed mode list and
lock in a scrubbed fixture, golden, and test for this dump.
2026-07-28 13:12:40 +00:00
Marc Billow f5be651430 Merge pull request #146 from perseus177/artik051-krac-legacy-ac
Support ARTIK051_KRAC_18K air conditioners (issue #136)
2026-07-28 08:00:48 -05:00
blka 1bbecfa5c3 Drop /information/vs/0 version entities per review
mbillow's follow-up review: exposing read-only Software/Firmware (and
Outdoor/Touch IC) version strings is "data for the sake of exposing it" --
no user control, just clutter, and every other registry leaves
/information/vs/0 in the global ignore as identity plumbing. Conforming to
that stance rather than expanding the entity surface for no user story.

- by_type/airconditioner.py: revert to *ignored.IGNORED (no _IGNORED_LESS_INFO
  filter); drop airconditioner.INFO from the registry.
- capabilities/airconditioner.py: remove the INFO capability, the _info_version
  /_info_items_of_type /_has_info_version helpers, and HREF_INFORMATION.
- translations/{en,nl}.json: drop software_version, firmware_version,
  firmware_version_2/3, outdoor_unit_version, touch_ic_version.
- tests: drop the six INFO tests; golden regenerated for 8 AC + dehumidifier.
625 tests pass.
2026-07-28 10:07:39 +02:00
Marc Billow 6b28272647 Enhance README with GitHub badges
Added badges for GitHub stars, watchers, releases, and validations.
2026-07-27 23:26:01 -05:00
Marc Billow cc570533a0 Merge pull request #149 from mbillow/claude/ticket-127-device-coverage-xsb0m4
Distinguish not-yet-fetched stub reps from confirmed-empty ones (issue #127)
2026-07-27 22:25:38 -05:00
Marc Billow 6239706065 Keep entity._is_included's default gate permissive on confirmed-empty reps
Opus review of #149 caught that swapping is_stub_rep(rep) in for the
default field-presence gate (not just the 9 hand-audited exists_fn call
sites) was too broad: it silently excludes entities on ANY resource whose
normal, valid state includes reporting {} -- /alarms/vs/0's {} is
fridge.py's documented no-alarm state, not an absence signal, and it's not
the only one (job_beginning_status, diagnosis_status, sabbath_mode,
defrost_delay, ice_maker_enabled all lost entities on real fixtures under
the broader change). That's the opposite of #127's fix: a real fridge
would have dropped its alarm sensor on first-poll timing, not just its
phantom energy sensors.

Restored the default gate to include on either a stub or a genuinely-empty
rep -- verified byte-identical to the pre-#149 baseline across all 40
fixtures, apart from the 9 deliberately-audited exists_fn sites (energy
meter, self-check error, cooktop burner, range-hood auto-op), which are
unaffected and still fix #127. Added tests/test_entity.py exercising
_is_included directly (previously untested) and fixed two now-stale
"not rep" doc references the review also flagged.
2026-07-28 03:18:23 +00:00
Marc Billow 33786ad584 Distinguish not-yet-fetched stub reps from confirmed-empty ones (issue #127)
parse_device0_batch used to collapse /device/0's {"href": "..."} "no data
yet" marker into a plain {}, indistinguishable from a resource the device
had actually polled and confirmed empty. Every exists_fn using the "not
rep or ..." stub carve-out (and entity._is_included's default field-gate)
then treated both the same way, creating phantom always-"unknown" entities
for any resource a model simply doesn't support (e.g. GSzabados's fridge's
/energy/consumption/vs/0).

is_stub_rep() now recognizes only the literal {"href": ...} marker as a
stub; a genuine {} is treated as the device's real (if empty) answer and
gates the entity off like any other missing field. Updated the energy
meter, self-check error, cooktop burner, and range-hood auto-operation
exists_fn call sites, plus three golden fixtures that had baked the
phantom-entity behavior in as "expected".
2026-07-28 02:57:30 +00:00
Marc Billow e60fdf26d2 Merge pull request #148 from mbillow/claude/triage-issues-144-147-yv80ab
Fix water-purifier hot-water lock mislabel, add range-hood after-run support
2026-07-27 21:31:31 -05:00
Marc Billow 9011f84787 Model after_run_progress as a percentage, fix Dutch after-run-progress name
runningProgress's own field name states its domain, so restore unit='%' and
state_class='measurement' rather than leaving it an opaque passthrough --
that hedge made sense for activationState (no supported-values list, no
write contract to invent) but not here, where the name itself is the
evidence.

"Nadraaien voortgang" also wasn't idiomatic Dutch (nouns don't stack that
way); "Voortgang nadraaien" matches how the rest of the catalog compounds
these names.
2026-07-28 02:29:01 +00:00
Marc Billow 0640ac3477 Fix hotwater_lock key-collision hazard, address Opus review of triage fixes
An Opus review of the previous commit found that giving the switchHotwater
fallback and LOCK.hotwater_lock the same key introduced a real bug:
adapter.flatten() (the source of coordinator.data, which every switch's
is_on reads) only ever honours exists_fn, never entity.py's implicit
own-field-presence default that gates plain registration. With only one
side of the pair gated, both descriptors still wrote the same key into the
flattened state dict, and whichever was processed last -- decided by
device-reported href order, not correctness -- silently won. Reproduced
with the existing coffee fixture: reversing resource order flipped
hotwater_lock from correct (False) to a stuck True.

Fixed by gating both sides symmetrically via a shared tri-state helper that
also treats an unfetched /status/lock/vs/0 stub as "outcome pending" rather
than "confirmed absent" -- otherwise the stub window let both descriptors
pass exists_fn at once, which would have registered two switch entities
with the same unique_id. The fallback also re-asserts its own field's
presence, a check it used to get for free before it shared LOCK's key.

Also addresses two smaller findings from the same review, both in the
range-hood after-run capability (#147): runningProgress's unit='%' was a
guess from a single "0" sample with no supported-values/range field to
confirm the domain -- inconsistent with treating activationState as
read-only for the same "don't guess" reason -- so it's now a bare
passthrough sensor; and entity_category='diagnostic' was dropped from the
two read entities since after-run is a feature the user actively watches
and cancels via the (correctly uncategorized) button, not passive
diagnostics.
2026-07-28 02:25:42 +00:00
Marc Billow b47dabeb31 Merge pull request #143 from mbillow/claude/microwave-fanspeed-coverage-nmvc86
Microwave vent fan and kimchi-refrigerator compartment coverage (#137, #142, #26)
2026-07-27 21:13:03 -05:00
Marc Billow cc3ce12aa4 Fix range hood fan power targeting and kimchi mode write validation
- _speed_zero_is_off now keys off the hood resource's own
  settableMinFanSpeed/supportedFanSpeed fields instead of asking whether
  the device has any power resource at all, so a combi appliance's cavity
  /power/0 can no longer be toggled off by turning off just the vent fan.
- async_turn_on() no longer resets an already-running fan to its lowest
  speed when called without a percentage.
- _has_separate_power() reads through the O(1) resource cache instead of
  copying the full resource snapshot on every property access.
- _kimchi_mode_write rejects values the compartment didn't advertise in
  supportMode instead of writing them blind.
- kimchi_ripening_status no longer lowercases its value, since it has no
  enum catalog entry to translate the lowercased token back through.
- Documented why KIMCHI_DOOR_GENERIC isn't deduped against the /doors/vs/0
  aggregate fallback on the one fixture that reports both.

Adds regression tests for the combi-appliance power targeting, the
already-on turn_on no-op, kimchi mode write validation, and a kimchi
select display/write casing round-trip; a translation-coverage guard for
kimchi_zone_mode codes mirroring the existing AC preset one.
2026-07-28 02:10:01 +00:00
Marc Billow 5055d6bb72 Fix water-purifier hot-water lock mislabel, add range-hood after-run support
Water purifier (#144, #145): /favorite/hotwater/vs/0's switchHotwater field
is a Locked/Unlocked hot-water lock, not a "favorite enabled" flag. It's the
same lock as LOCK.hotwater_lock, just surfaced through this href on boards
that don't populate /status/lock/vs/0's hotwaterLock -- the two now share
the hotwater_lock key/translation, gated so only one is ever active.

Range hood (#147): binds /afterrun/vs/0 (after-run activation state,
progress, and a cancel button), clearing the last unbound href for
AHD-WW-TP1-22-COMMON.
2026-07-28 02:00:57 +00:00
perseus177 55c7b88a8f fix(airconditioner): label the 2Step preset and test presets by their HA value
The legacy Comode codes resolve through the same dynamic resolver as a real
convenient resource, so Nano lands on the existing 'nano' preset (already
labelled WindFree) rather than on a 'windfree' value of its own -- the new
tests asserted the label instead of the value. 2Step had no catalog entry in
either language and would have surfaced as the raw code.

Also updates the existing five-percent-humidity test, which reached into the
descriptor's field/value_fn directly, to the rep_fn the fallback needs, and
covers the fallback itself.
2026-07-28 02:38:28 +02:00
Marc Billow 265d94eded Add kimchi-refrigerator compartment coverage (issue #26)
TP2X_REF_20K-class 3-compartment kimchi refrigerators report each
compartment's storage mode and ripening status/timer on
/status/kimchi/<slot>/vs/0, plus a top-compartment door sensor on
/kimchidoors/top/vs/0 -- all previously unbound. Bind them as pattern
capabilities (fridge.KIMCHI_ZONE, fridge.KIMCHI_DOOR_GENERIC), deriving
the per-compartment entity key and display name from the href's
top/middle/bottom segment, the same way DOOR_GENERIC/TEMP_CURRENT_GENERIC
already do.

Storage-mode option labels were translated directly from the reporter's
own SmartThings app screenshots rather than guessed from the raw device
codes or their English paraphrase, confirming the on-screen option order
matches supportMode's array order (including the freezer triplet's
-19/-21/-17°C -> Standard/Strong/Weak mapping).

Also tighten FLEX_ZONE's exists_fn: this device's /mode/vs/0 also
populates modes/supportedOptions, but with a token shape that never
overlaps (a "_[n]:[n]" suffix supportedOptions carries that modes never
repeats), so the existing "supportedOptions is nonempty" check let the
entity bind anyway and get stuck permanently on "unknown". Requiring an
actual resolvable value keeps it working for the RF9000/Bespoke-class
fridges it was built for while leaving it absent here.
2026-07-28 00:35:21 +00:00
perseus177 3032b0c032 test(airconditioner): lock in the ARTIK051_KRAC_18K surface
Fixture is a scrubbed diagnostics dump from the unit the writes and
calibrations were verified on; the issue #136 unit is the same model with a
slightly different token set (no Spi, FilterTime_5460, OutdoorTemp_81), which
the presence gating handles the same way.

Covers the pieces the golden's state_keys can't: that the token entities stay
off newer boards, that an absent token yields no entity, that humidity's zero
reads as unknown, that fan/swing/preset read and write through /airflow/vs/0
and the Comode token, and that a board with /wind/* and /mode/convenient/vs/0
still takes the resource paths.

Refs #136
2026-07-28 02:28:59 +02:00
perseus177 5b30099c42 feat(airconditioner): fan, swing, presets and option-token settings on ARTIK051 boards
This board generation predates every AC dump the registry was built from and
differs in three ways, all handled here behind presence checks so no other
family's behaviour changes:

* No /wind/* resources at all. Fan speed and vane direction share a single
  /airflow/vs/0 resource, whose speedLevel uses the same 0-4 scale as
  _DEVICE_TO_FAN and whose direction uses the same codes as _DEVICE_TO_SWING,
  so the existing maps are reused rather than duplicated. The resource reports
  no supportedModes, so the full scale is offered.
* No /mode/convenient/vs/0. The convenient-mode preset is a Comode_* token in
  /mode/vs/0's options, synthesised into a convenient-shaped rep so the
  existing dynamic preset resolver keeps working unchanged. Codes were learned
  by driving one unit through its cloud integration and reading the token back
  each time: Nano is what the app calls WindFree, plus Quiet/Comfort/2Step/
  Speed (Fast Turbo) and Off.
* Several settings that newer boards expose as dedicated resources are options
  tokens here: SPI, auto clean, air monitoring, beep volume, Good Sleep,
  outdoor temperature and filter time. Writes reuse option_write's single-token
  merge, the same mechanism the display light already uses on this href.

Newer families carry some of the same tokens *alongside* dedicated resources
for those settings, so the token entities are gated on this generation's
resource shape (/airflow/vs/0 present, /wind/strength/vs/0 absent -- the same
test the climate entity's fan/swing fallback uses, so the two can never
disagree). Without that gate they duplicated auto clean on TP1X/TP2X boards
and applied a calibration from this board to theirs.

Two calibrations, both from hardware rather than from the token names:
OutdoorTemp is offset by 55 (token 75 against a 20.3 C outdoor thermometer in
the same install, token 74 against a 19.4 C forecast; Fahrenheit fits far
worse), and FilterTime is tenths of an hour (token 1710 while the official
Samsung app displayed "171 hours 0 minutes" for the same unit's filter).
Whether filter time counts up or down is deliberately not claimed: it was seen
rising while the unit ran, which contradicts the app's "remaining" wording.

Humidity now falls back to the plain x.com.samsung.da.humidity field where
fivepercentHumidity is absent, still as one entity rather than two, and 0 reads
as "not measuring" rather than 0% -- on this board the field only carries a
reading (51%, matching the same unit's cloud integration) while Air monitoring
is on, which the unit switches back off by itself after about a minute.

Fan, swing, preset, SPI and beep-volume writes were confirmed by read-back on
hardware. Good Sleep's upper bound is a guess (only 0 has been observed), and
/airflow/0 -- the OCF-standard mirror of the vendor resource -- is ignored
rather than modelled, since air_purifier.py found the opposite reliability
ordering between these two hrefs on its own family.

Refs #136
2026-07-28 02:28:33 +02:00
perseus177 75f2be7aaf fix(registry): resolve ARTIK051_KRAC_18K to the airconditioner registry
Room air conditioners on the ARTIK051 board (ARTIK051_KRAC_18K, issue #136)
report no oneUiVersion and carry a '_KRAC_' token in modelNum. The existing
'_RAC_' check can't see it -- the 'K' sits between the underscore and 'RAC' --
and the consumer-prefix fallback only covers washers/dryers/dishwashers, so
these units fell back to 'unknown': 8 of their 19 resources ended up unbound
and the device exposed nothing but a power switch.

Same ARTIK051 board family as the '_TVTL_' air purifier handled just below.
2026-07-28 02:28:13 +02:00
Marc Billow e9281aaead Bind microwave built-in vent fan's /hood/fanspeed/vs/0 (issues #137, #142)
Combi microwave units report their vent fan on the same resource shape a
standalone range hood uses, so reuse range_hood.HOOD_FAN directly in the
microwave registry. Unlike a standalone hood, this board has no sibling
/power/0 or /power/vs/0 resource, so LocalThingsRangeHoodFan now falls
back to treating fan speed 0 as the off state when no separate power
resource is present. Also gate HOOD_FAN's automatic_operation sensor on
field presence, since this board doesn't report it.
2026-07-28 00:18:38 +00:00
Marc Billow c19800ac00 Merge pull request #135 from QuiteYellow/fix/stale-dtls-session-fixed-source-port
Bind a fixed DTLS source port per device to evict stale sessions
2026-07-27 18:40:36 -05:00
Marc Billow ed5e8e57c8 Merge pull request #140 from mbillow/claude/v0-13-0-issue-triage-9zfjbj
Split microwaves into their own device type instead of the oven registry
2026-07-27 17:10:10 -05:00
Marc Billow f063666291 Merge pull request #139 from mbillow/claude/air-purifier-fan-controls-ananzq
Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)
2026-07-27 17:06:59 -05:00
Marc Billow 5af9d951c6 Simplify README microwave row label 2026-07-27 22:05:54 +00:00
Marc Billow a1f14cd633 Split microwaves into their own device type instead of the oven registry
Microwaves (combi and plain) were routed onto the oven registry (issue
#121), which meant entities carried oven-flavored keys (oven_state,
oven_mode, oven_setpoint) and inherited oven-specific behavior that's
wrong for this family: a 30-270C setpoint range instead of this family's
actual 40-200C, a cooking-mode list missing MicroWave/MicroWaveGrill/
MicroWaveConvection/KeepWarm entirely, and a lamp switch that read/wrote
the oven's 'UpperLamp' option token instead of this family's 'Lamp' token.

Adds a microwave device type (by_type/microwave.py,
capabilities/microwave.py) that reuses the oven board family's shared
operational-state/door/connected/recipe-cook capabilities but defines its
own cooking-mode, setpoint, and cavity capabilities with the corrected
bounds/vocabulary, plus a new power_level sensor for the cavity's Watt
setting that was previously unexposed.
2026-07-27 22:05:54 +00:00
Marc Billow 2be742489b Fix airflow fan power-href preference and unique_id collision risk
Opus review of the previous commit caught two real bugs. The airflow fan's
power writes preferred /power/vs/0, copied from the TP1X fan class -- but
that order is only harmless there because TP1X never reports /power/0 at
all. This family's dumps carry both hrefs, and the power_switch entity is
unconditionally bound to /power/0 when present, so the fan was writing to
a different resource than power_switch reads/writes, leaving the two
entities disagreeing until the next poll. Flipped to prefer /power/0,
matching the range hood's fan and common.POWER_GENERIC.

Also renamed the new FanDesc's key from 'fan' to 'airflow_fan': BoundEntity
unique_ids are derived from key alone, not href, so it collided with
air_purifier.FAN's own 'fan' key on the (currently unobserved, but
unenforced) possibility of a board reporting both.

Added a platform-level test file covering the power-href preference and
percentage<->speed-code mapping, mirroring test_range_hood_fan.py's harness.
2026-07-27 21:48:23 +00:00
Marc Billow d4583b3240 Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)
/airflow/0's speed was left read-only because the first round of diagnostics
wasn't conclusive (0 for both Auto and High, 3 for Low/Medium and Sleep) --
likely because all five dumps were captured within about a minute of each
other, faster than this integration's own poll cycle could settle each
change. A second round, captured 60-90s apart per setting on two independent
units, confirmed a clean monotonic 0-4 mapping across Auto/Sleep/Low/Medium/
High instead.

Builds an ordered-speed fan off that confirmed range, the same SET_SPEED
shape as the range hood's fan -- this board never self-reports a
supportedModes-style label list, so there's no named-preset table to
preserve, just percentage steps over the raw code. /airflow/vs/0's vendor
speedLevel stays a read-only fallback since it was unreliable in that same
second round.
2026-07-27 21:32:44 +00:00
blka b18500dec3 Merge upstream/main into ac-additive-entities
Conflicts resolved:
- capabilities/airconditioner.py: keep my NumberDesc/SelectDesc imports +
  upstream's hoist of _filter_usage_percent -> common.filter_usage_percent
  (local def removed by upstream's auto-merge; AIR_FILTER.air_filter_usage
  now references the common helper). Upstream's ANOMALY_LOAD, HREF_WIND_OSCILLATION
  and oscillation climate-write kind kept; my beep/tropical/INFO/AIR_QUALITY/
  threshold-Select/filter-hours kept. Both change sets coexist.
- translations/{en,nl}.json: switch section -- keep both my 'beep' and
  upstream's display/pet_filter_activation/auto_empty/dustbin_auto_close/
  uvc_intensive_mode entries.

Regenerated the 8 AC + dehumidifier goldens (+ the 2 new upstream AC fixtures
ara_ww_tp1_22, windfree_oscillation) against the merged code. 631 tests pass.
2026-07-27 22:36:06 +02:00
blka 51fa1c5ea8 Address review: per-item versions, writable threshold, unit_fn, gating
Per mbillow's review on PR #129 (CHANGES_REQUESTED). Items 1-7 + smaller.

1. INFO: expose each /information/vs/0 version item per (type, ordinal) instead
   of collapsing to a single first-Firmware value. Boards carry 1-3 Firmware
   items (separate MCUs) plus an Outdoor unit and (window AC) a Touch IC item;
   each is a distinct version string. _info_version(items, type_, ordinal)
   + _has_info_version exists_fn gate, so an item with no number (tp2x_rac_20k's
   second Firmware) suppresses the entity rather than binding unknown.

2. air_filter_threshold is locally writable, not cloud-only -- confirmed live
   on ARTIK051_PRAC: POST filterDesiredUsage=700 to /filter/airdustfilter/vs/0
   -> 2.04, read-back 700, persists; restored to 500. Converted from a
   read-only sensor to a SelectDesc keyed to the device's
   supportedFilterDesiredUsage enum (options_field), with a write_fn that
   POSTs the scalar field. Only binds where the enum is advertised; boards
   without it leave this writable field unexposed rather than guess the valid
   set (don't-guess).

3. air_filter_usage_hours uses unit_fn reading filterCapacityUnit ('Hour'->'h')
   instead of a hardcoded unit, so a board advertising a different unit doesn't
   mislabel a duration statistic.

4. air_filter_usage_hours state_class is total_increasing, not measurement --
   filterUsage is a lifetime hour counter that resets on filter replacement.

5. INFO and air_filter_threshold now carry exists_fn (AIR_QUALITY already did),
   so they don't bind a permanently-unknown entity when their item/field is
   absent. Also fixes the caww_tp2 golden nuance (filterDesiredUsage absent
   -> no threshold key, matching what HA would actually create).

6. AIR_QUALITY: CleanLevel is corroborated as numeric by a top-level
   x.com.samsung.da.cleanLevel scalar (tp1x_da_ac_rac_01011 reports both as
   '1'), so clean_level is now an int measurement; odor/dust/fine_dust stay
   string diagnostics. Reinstated the 2-element-array ambiguity note (Dust/
   FineDust/SuperFineDust report ['0','0']; v[1] meaning unconfirmed, v[0]
   taken as the reading). SuperFineDust is now modeled for consistency with
   Dust/FineDust (same shape), rather than skipped without reason.

7. _beep_write restores the last non-Mute Volume level on 'On' instead of
   forcing Volume_100, so an intermediate setting (e.g. Volume_50 set via
   the cloud) survives an off/on cycle; falls back to 100 when no prior level.

Smaller: test_air_quality now asserts the tp1x_da_ac_rac_01011 clean_level==1
non-zero reading (the one value_fn-regression catch in the corpus); renamed
by_type's _AC_IGNORED -> _IGNORED_LESS_INFO to resolve the two-meaning
collision with the capabilities module's _AC_IGNORED (href strings); golden
regenerated for the 8 AC fixtures + dehumidifier.

612 tests pass.
2026-07-27 22:22:56 +02:00
Jack Nagy 0ebcfb00ff fix: bind a fixed DTLS source port per device to evict stale sessions
When HA restarts without a clean DTLS close_notify (crash, host reboot),
the appliance keeps an orphaned DTLS association keyed to the client's
(IP, source port). Reconnecting from a fresh ephemeral port looks like a
new peer, so the device holds the orphan until its own timer reaps it,
which is 5 to 15 min on always-on appliances (fridges), during which the
new session's first reads hang. This is the root cause behind the repeated
"DTLS handshake timeout" reconnect storms on always-on devices (#119).

Bind a deterministic source port per device so every reconnect re-handshakes
over the same 5-tuple, which the device must treat as a rebooted peer and
evict the old association for (RFC 6347 §4.2.8). Recovery drops from a
device-timer wait to a single handshake.

The port must be stable across restarts and unique per device on the HA host
(the library socket is unconnected, so a shared source port would cross-
deliver datagrams). _local_source_port() uses the host's last IPv4 octet as
the offset from DTLS_LOCAL_PORT_BASE (unique on a /24), with a CRC32 fallback
for non-IPv4 hosts.

Requires smartthings-local >= 0.1.1, which adds DtlsCoapSession(local_port=).
The fix is backwards compatible upstream: local_port defaults to None
(previous ephemeral-port behaviour).

Root-caused and verified upstream in QuiteYellow/SmartThings-Local#14
(bench-verified on oven + dryer, field-verified on an always-on fridge
across repeated restarts).
2026-07-27 19:17:39 +01:00
Marc Billow 7c68d478af Bump version to 0.13.0 2026-07-27 14:54:26 +00:00
Marc Billow 3c15ca810b Merge pull request #132 from mbillow/claude/triage-issues-111-127-on5l50
Triage issues #111-#131: AC/oven/air-purifier detection fixes, new vacuum-station type, reconnect log noise
2026-07-27 09:46:11 -05:00
Marc Billow e9eb38740d Deduplicate ISO-timestamp parsing and document the new device type (review follow-up, issue #131)
- vacuum_station._parse_iso_utc was a verbatim copy of
  water_purifier._parse_iso_utc; promoted to common.parse_iso_utc and
  pointed both families at it. Also made it tzinfo-aware rather than
  unconditionally overwriting with UTC -- harmless today since every
  dump seen is a bare or Z-suffixed UTC timestamp, but a board that
  ever emits a real offset would otherwise have it silently clobbered.
- Added the new vacuum_station type to the README's supported-appliance
  table, and noted that combi microwaves route through the oven
  registry.
2026-07-27 14:43:02 +00:00
Marc Billow f37c9ec4ef Fix air-purifier fan power write and silent preset-mode rejection (review follow-up, issue #130)
- The fan's power write hardcoded /power/vs/0 while is_on already read
  /power/0 as a fallback -- a board reporting only the OCF resource
  would show correct state but silently no-op on every turn-on/off.
  Mirrors LocalThingsRangeHoodFan's existing _power_payload pattern:
  target whichever power href the board actually reports.
- async_set_preset_mode fell off the loop silently on an unmatched
  mode with no log and no error, unlike the rest of this codebase's
  write-rejection handling. Logs a warning now.
- Deduplicated HEPA_FILTER's usage-percent calculation, which was an
  inline reimplementation of airconditioner._filter_usage_percent;
  promoted the shared logic to common.filter_usage_percent and pointed
  both families at it.
- Gave air_purifier.SOUND_MODE its own translation_key instead of
  defaulting to the same catalog entry laundry.SOUND_MODE uses. That
  entry's state table is {voice, tone, mute}; this board's is
  {mute, buzzer} -- sharing it left 'buzzer' with no label.
2026-07-27 14:42:34 +00:00
Marc Billow d26e7b957b Fix unreachable reconnect-warning threshold (review follow-up, issue #119)
The 60s/5-reconnect window from the original fix could never actually
fire: consecutive reconnect attempts are never closer together than one
summary poll interval (30s) plus the 5s reconnect pause, so at most ~2
timestamps can ever land inside a 60s window regardless of how unhealthy
the connection is. That silently downgraded every reconnect to INFO
permanently, including the persistently-broken case the change was
supposed to still surface at WARNING.

Widen to a 300s window with a threshold of 3, which is reachable under
sustained failures and still a reasonable proxy for the README's
"actually broken" case.
2026-07-27 14:41:43 +00:00
Marc Billow b31f4f0c40 Merge pull request #128 from pedroperosin/fix/climate-set-temperature-hvac-mode
Honour hvac_mode in the AC climate set_temperature
2026-07-27 09:30:19 -05:00
Marc Billow 8b44fd5710 Add device support for the stick-vacuum clean/auto-empty station (issue #131)
A-VSKR-TP1-22-VS9500AL connects successfully but its dump shows no
vacuum-body state at all -- no suction level, no battery, no cleaning
mode -- only the clean/auto-empty station's own dustbag, dustbin
auto-empty settings, and UV-C sanitizing-cycle status. This strongly
suggests the WiFi/DTLS module lives in the station, not the handheld
stick, so the station is the only "device" this integration's local
API can reach at all.

New vacuum_station device type (these hrefs share nothing with any
existing family, so there's no shared-href ambiguity to resolve
against another type) routed via a new '-VSKR-' modelNum fallback.
Binds with zero unbound hrefs: dust-bag full/usage sensors, auto-empty
and dustbin auto-close switches, a discharging-time select, and
clean-station status including UV-C intensive mode, operation time,
and finished/emitted timestamps. A couple of fields with unconfirmed
exact semantics (stick_status, dustbag_usage's unit) are exposed as
plain diagnostic values rather than an asserted binary/percentage
meaning.
2026-07-27 14:11:06 +00:00
Marc Billow 4e1eb7d03d Add fan-mode control for TP1X_DA-AC-AIR air purifiers (issue #130)
This newer board family reports fan modes (Smart/Max/Mid/WindFree/Sleep)
directly on /mode/vs/0's top-level modes/supportedModes fields, unlike
the older ARTIK051_TVTL family this registry already supported, which
packs everything into an options[] array with no usable fan-speed
selector at all (see the module docstring's Comode_Off finding). Both
board generations share the /mode/vs/0 href, so the existing MODE
capability and a new FAN capability are discriminated by a match_fn
checking for the top-level supportedModes field, rather than adding a
new device type.

The fan entity only exposes PRESET_MODE, not an ordered percentage --
WindFree/Smart/Sleep are named behaviors, not "faster/slower" positions
relative to Max/Mid, matching how the AC family's own named convenient
modes are modeled as a preset rather than a speed number.

Also picked up the rest of this board's previously-unbound hrefs while
in there (display, HEPA filter, panel status, pet-filter mode, sound
settings), reusing airconditioner.DISPLAY_LIGHT and
airconditioner.MUTE_ONCE for the two hrefs identical to the shared
DA-AC- board family, since the "incomplete capability coverage" repair
was firing on more than just the fan gap the issue described.
2026-07-27 14:08:32 +00:00
Marc Billow e44fef7085 Route combi microwaves onto the existing oven registry (issue #121)
TP1X_DA-KS-MICROWAVE-01041 (MW7300B) reports no oneUiVersion and an
unrecognized consumer token, so it fell back to 'unknown' and only got
common capabilities. It shares the same '/oven/vs/0' cavity resource
and '/mode/vs/0' cook-mode shape (Convection/AirFryer/Grill/MicroWave*)
as the wall oven already supported, so this reuses that registry via a
new '-MICROWAVE-' modelNum fallback rather than adding a new device
type. The only href it didn't already cover was /recipe/cook/vs/0, an
empty quick-recipe-display blob bound with no entity per the 'don't
guess' rule.
2026-07-27 13:41:36 +00:00
Marc Billow 6f10a3b796 Support 2-axis wind oscillation and overload-protection status on newer WindFree boards (issue #126)
Newer TP1X_DA-AC-RAC-01011_0000 firmware (Bespoke AI WindFree Deluxe,
AR60H10D1JWNME) drops /wind/direction/vs/0 entirely and reports swing
via a separate vertical/horizontal Swing|Fix pair on
/wind/oscillation/vs/0 instead, which left swing_mode/swing_modes
silently empty and the href unbound. climate.py now falls back to the
oscillation resource when /wind/direction/vs/0 is absent, mapping the
same off/vertical/horizontal/both vocabulary the existing swing control
already uses.

Also binds the board's /anomalyload/vs/0 overload-response resource as
read-only diagnostic sensors (operation state + mode) -- the same
"don't guess" precedent as the existing CURRENT_LIMIT capability, since
nothing in the dump confirms the exact behavioral difference between
its 'Alarm' and 'PowerSaving' modes or whether toggling it is safe on
live HVAC hardware.

Most of the other gaps this issue reported (Fan-only mode, WindFree
preset labels, target-temperature channel selection, power on/off via
the vendor resource) turned out to already be fixed by the just-merged
cool-only global RAC work.
2026-07-27 13:41:04 +00:00
Marc Billow 2c8a765036 Downgrade a lone poll-failure reconnect to info (issue #119)
Samsung's firmware occasionally drops the DTLS session briefly --
normal appliance-side behavior per the README's "Known device
behavior" section -- so the coordinator recovering from that on its
own doesn't need a WARNING. Only escalate once reconnects pile up
within a trailing 60s window (5+), matching the README's own "more
than a handful per minute" definition of an actually broken
connection.
2026-07-27 13:40:32 +00:00
Marc Billow f62b4aeec8 Detect ARA-WW-TP1-22-COMMON wall-mount RACs as airconditioner (issues #115, #116, #117, #120)
AR10/13/18BYEAAWKNME report no oneUiVersion and no '_RAC_'/'-RAC-'
token at all, so for_device_by_model() fell through to 'unknown' and
every href went uncovered. The board carries the same TP1X-class
resource surface as every other room AC already supported (mode/
convenient/wind/temperature/power/filter/humidity), so this reuses the
existing airconditioner registry via a new 'ARA-WW-' modelNum fallback
rather than adding a new device type -- confirmed against all four
reporters' dumps binding cleanly with zero unbound hrefs.
2026-07-27 13:40:12 +00:00
Marc Billow 46dd91ce32 Add regression coverage for NE8300D range (issue #112)
TP1X_DA-KS-RANGE-0102X already resolves via the '-RANGE-' modelNum
fallback and /cooktopmonitoring/vs/0 already binds through
range.COOKTOP_MONITORING, so this model binds with zero unbound hrefs
today -- add a fixture to lock that in.
2026-07-27 13:39:51 +00:00
Marc Billow 085e80c92c Add regression coverage for WA55A7700AV washer (issue #111)
The DA_WM_TP1_21_COMMON board family already routes through the 'WA'
consumer-model-prefix fallback and binds cleanly against the washer
registry with zero unbound hrefs, but no fixture locked that in for
this specific board generation -- add one.
2026-07-27 13:39:30 +00:00
Pedro a9f21982e7 Honour hvac_mode in the AC climate set_temperature
HA's set_temperature service forwards an optional hvac_mode to the entity, and
the entity is expected to apply it. The AC climate entity ignored it and only
wrote the setpoint, so a set_temperature call carrying hvac_mode (e.g. a
dashboard "turn on to Auto 24" button) set the temperature but never changed the
mode or powered the unit on. Apply the mode first -- which powers the unit on
when it was off -- then the setpoint.
2026-07-27 09:57:31 -03:00
blka 3da01f80d0 feat(airconditioner): add beep, tropical night, filter hours/threshold, air-quality, sw/fw version
Layer the ARTIK051_PRAC additive entities onto the upstream registry on a
fresh branch (additive-only; the round-1 display-light/mute-once/WindFree
work was independently shipped upstream and is not redone here).

New entities, all driven by single-token option_write or item reads:
- beep (switch): Volume_Mute/Volume_100 option token; single-token merge --
  a full options RMW reverts on ARTIK051_PRAC. Cloud counterpart:
  samsungce.airConditionerAudioFeedback (on/off only; level is cloud-only).
- tropical_night_mode (number 0-16): Sleep_<N> option token. Cloud:
  custom.airConditionerTropicalNightMode.
- air_filter_usage_hours / air_filter_threshold (duration sensors, h):
  raw filterUsage count and filterDesiredUsage alarm threshold. Threshold
  SET is cloud-only (samsungce.dustFilterAlarm); local read-only.
- clean_level / odor / dust / fine_dust (diagnostic sensors): /sensors/vs/0
  items[]. No unit advertised on the resource, so no device_class until a
  populated reading + unit is observed (don't-guess rule). SuperFineDust
  intentionally not modeled.
- software_version / firmware_version (diagnostic sensors):
  /information/vs/0 items[]. The href is globally ignored as identity
  plumbing; the AC registry drops that ignore so INFO is the sole cap on it.

Translations: en.json + nl.json (every-language-mirrors-english invariant).
Golden regression: regenerated the 8 AC fixtures + dehumidifier (reuses
AIR_FILTER) for the new state keys.

608 tests pass.
2026-07-27 14:43:07 +02:00
Marc Billow ef23f5ec32 Merge pull request #114 from mbillow/claude/pr91-finish
Add cool-only global RAC support: WindFree, Auto mode, and display light
2026-07-27 00:35:48 -05:00
Marc Billow 5547c401ed Address independent review findings on the RAC finish-up branch
- Pin the FAN_ONLY reverse-write fallback to 'Wind' (the original single
  spelling) instead of letting it silently flip to 'Fan' just because
  'Fan' was added second to the dict -- _device_code_for_hvac() resolves
  the code from a unit's own supportedModes first, so this dict is only
  a fallback for a unit reporting none at all, and that fallback
  shouldn't change behavior as an unintended side effect of insertion
  order.
- Add direct tests for _preset_to_ha() (pure function, previously
  untested) and the FAN_ONLY fallback pin.
- Cross-reference the AC family's inverted Light_On/Light_Off polarity
  against air_purifier.py's plain-polarity use of the same token name on
  the same resource name, so a future refactor doesn't assume they're
  the same thing.
- Fix a one-column continuation-line misalignment and a stale PR-number
  reference in a comment.
2026-07-27 05:11:58 +00:00
Marc Billow fa8f1b8675 Add cool-only global RAC support: WindFree, Auto mode, display light
Finishes PR #91's contribution (pedroperosin) with the requested review
changes applied, on our own branch:

- Preset resolution is now fully dynamic, read from each unit's own
  /mode/convenient/vs/0 supportedModes instead of a static per-model
  table -- any board's convenient modes (including WindFree's Nano/
  NanoSleep) surface without code changes. Unlabelled codes across
  existing fixtures (longwind, motionindirect, motiondirect, drycomfort)
  plus the two new WindFree ones are added to en.json/nl.json.
- 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are
  single-setpoint "device decides" units, not two-setpoint heat+cool
  ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling;
  a new _device_code_for_hvac() picks the code from the unit's own
  supportedModes since the flat map can't disambiguate two device codes
  mapping to one HA value.
- Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the
  existing '_RAC_') for cool-only global RAC variants whose
  /otninformation/vs/0 ships no swVersionInfo block.
- Adds a display_light switch sourced from /mode/vs/0's opaque options
  blob (inverted Light_On/Light_Off token) for boards with no dedicated
  /light/vs/0 switch.

Write-path behavioural change (touches the path iterated on across
#9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of
the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on
several known AC boards, so the previous OCF-first read/write pair could
report and act on stale state -- consistent with #53's "can turn on but
not off". Target temperature now picks its channel (OCF pair vs. vendor
items[]) based on which the unit actually reports, reading and writing
the same one.

The vendor temperature write and the new display-light write both carry
only the changed field(s), not the whole resource -- confirmed sufficient
on the wire, the device merges the rest itself. That requires the
coordinator's optimistic cache to do the same merge on the read side so a
setpoint change doesn't blank out current/min/max/unit for the settle
window: common.py gains merge_items_field() next to the existing
merge_options_field(), and async_send_command wires it in for any write
touching x.com.samsung.da.items.

New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC-
01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens
for boards that gain the new options-based switch. Regenerated against
current main rather than copied from the original PR, since those
goldens had already shifted (current_temperature_c/humidity from issue
#75).
2026-07-27 05:00:06 +00:00
Marc Billow af00c2b938 Merge pull request #110 from mbillow/claude/device-support-issue-107-coffee
Add coffee-maker capabilities to the water purifier registry (issue #107)
2026-07-26 23:40:03 -05:00
Marc Billow 1177f0ed64 Merge pull request #109 from mbillow/claude/device-support-issue-106-wa-washer
Add WA (top-load washer) consumer-model prefix (issue #106)
2026-07-26 23:38:19 -05:00
Marc Billow 35775c3d4a Add coffee-maker capabilities to the water purifier registry (issue #107)
Some TP2X_WATERPURIFIER_20K units are coffee-capable and expose five
resources issue #90's original dump never had:
/favorite/coffee/vs/0, /favorite/hotwater/vs/0,
/brand/recipe/info/vs/0, /coffee/custom/recipe/vs/0,
/recipe/coffee/vs/0, and /recipe/coffee/deletion/vs/0.

Adds FAVORITE_HOTWATER (a switch + select pair on
/favorite/hotwater/vs/0, mirroring the existing FAVORITE_CAPACITY
pattern) and COFFEE (a switch + status sensor on
/favorite/coffee/vs/0). The remaining four hrefs are static
capability-advertisement blobs or empty on every dump seen so far --
no live "current recipe" or "current custom slot" field to expose --
so they're added to the ignored coverage list per the 'don't guess'
rule rather than modeled speculatively.

Confirmed against the issue #107 diagnostics dump with zero unbound
hrefs.
2026-07-27 04:19:19 +00:00
Marc Billow 8ac1d11d17 Add WA (top-load washer) consumer-model prefix (issue #106)
WA8000T reports no oneUiVersion and used the 'WA' consumer-model
prefix, unmapped in _CONSUMER_PREFIX_TO_KEY (only WW/WD/WF/WV were
covered), so it fell into the unknown-device-type fallback.

Adding a bare 'WA' entry collided with the unrelated '_WAC_' (Window
Air Conditioner, issue #87) board-family token: some devices report
description == modelNum, so 'WAC' shows up as its own description
segment and 'WAC'[:2] == 'WA' matched the new washer prefix before the
more specific '_WAC_' modelNum check ever ran. Fixed by reordering
for_device_by_model() to check board-family modelNum tokens first and
the fuzzier 2-letter consumer-model-prefix scan only as a fallback,
rather than patching the prefix matching itself (an earlier attempt --
requiring a digit immediately after the prefix -- broke issue #79's
real DVE50A8800 case, which has no digit there either). Added a
regression test pinning the WAC/WA disambiguation directly.

Confirmed against the issue #106 diagnostics dump with zero unbound
hrefs.
2026-07-27 04:15:08 +00:00
Marc Billow b3a9192088 Merge pull request #98 from mbillow/claude/device-support-issue-86-cooktop
Add standalone induction-cooktop support (issue #86)
2026-07-26 23:04:51 -05:00
Marc Billow 634f367e96 Merge remote-tracking branch 'origin/main' into claude/device-support-issue-86-cooktop
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
2026-07-27 04:04:19 +00:00
Marc Billow 482e238a7a Merge pull request #102 from mbillow/claude/device-support-issue-77-freezer
Device support issue #77: freezer
2026-07-26 23:03:59 -05:00
Marc Billow f31cee206b Merge remote-tracking branch 'origin/main' into claude/device-support-issue-77-freezer
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
#	tests/test_by_type.py
2026-07-27 04:03:38 +00:00
Marc Billow 14b5a7cb68 Merge pull request #96 from mbillow/claude/device-support-issue-88-dehumidifier
Add device support for Samsung dehumidifiers (issue #88)
2026-07-26 23:00:33 -05:00
Marc Billow 8628ae6864 Merge remote-tracking branch 'origin/main' into claude/device-support-issue-86-cooktop
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
#	custom_components/localthings/translations/en.json
#	custom_components/localthings/translations/nl.json
2026-07-27 04:00:15 +00:00
Marc Billow 38263eaa72 Merge remote-tracking branch 'origin/main' into claude/device-support-issue-88-dehumidifier
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
#	tests/test_by_type.py
#	tests/test_golden_regression.py
2026-07-27 03:58:53 +00:00
Marc Billow ff6e1ecff4 Rename gas cooktop registry's display name to avoid induction_cooktop confusion
Renames DeviceRegistry.name from 'cooktop' to 'gas_cooktop' for the
NA9300K-class gas-cooktop registry (PR #23), so diagnostics/device-info
labels no longer collide with the unrelated induction_cooktop family
(issue #86) -- two different OCF surfaces that happen to share the
English word "cooktop".

Safe rename: _REGISTRY_BY_KEY's 'cooktop' lookup key is unchanged, so
all three existing detection paths (oneUiVersion "Cooktop" exact
match, the legacy ARTIK051 modelNum rule, and the resource-signature
fallback) keep routing real devices exactly as before. Entity
unique_ids are built from device serial + entity key, not registry
name, so existing entities are unaffected. Only the DeviceInfo.name
and diagnostics device_type strings change, both cosmetic.
2026-07-27 03:56:32 +00:00
Marc Billow 9ccaa3f01d Merge pull request #95 from mbillow/claude/device-support-issue-90-water-purifier
Add device support for Samsung water purifiers (issue #90)
2026-07-26 22:53:40 -05:00
Marc Billow 78f1bb0f92 Fix unclosed PROBE_STATUS capability from a bad merge conflict resolution
The merge of main into this branch dropped PROBE_STATUS's closing
),\n) and glued issue #74's COOKTOP_MONITORING addition directly onto
its entities tuple, leaving an unclosed paren (SyntaxError on import,
breaking Pytest and Hassfest CI). Restores the closing parens; no
functional change.
2026-07-27 03:46:55 +00:00
Marc Billow 5e60f9b953 Fix stale Window AC golden fixture (current_temperature_c, humidity)
PR #75 (WindFree AC) added CURRENT_TEMPERATURE/HUMIDITY capabilities
to the shared airconditioner registry, which every AC device picks up
-- including the Window AC from PR #87. Both branches built their
golden fixtures independently against their own base commit before
either landed, so neither saw the other's addition; once both merged,
the Window AC's fixture went stale. The two extra keys are real,
working sensors from #75's work, not a regression.
2026-07-27 03:45:32 +00:00
Marc Billow 3b0f4f8b66 Merge branch 'main' into claude/device-support-issue-90-water-purifier 2026-07-26 22:06:20 -05:00
Marc Billow 2aaaad71a8 Merge branch 'main' into claude/device-support-issue-88-dehumidifier 2026-07-26 22:05:24 -05:00
Marc Billow 4719e3aa80 Merge pull request #97 from mbillow/claude/device-support-issue-87-window-ac
Add device support for Bespoke Window AC (issue #87)
2026-07-26 22:03:36 -05:00
Marc Billow 84d73105cf Merge branch 'main' into claude/device-support-issue-86-cooktop 2026-07-26 21:58:21 -05:00
Marc Billow d0e03b026c Merge pull request #99 from mbillow/claude/device-support-issue-83-fridge-detection
Catch the 'Nothing(SVC)' placeholder serial in both fallback sites (i…
2026-07-26 21:55:33 -05:00
Marc Billow d2f0a5c976 Merge pull request #100 from mbillow/claude/device-support-issue-80-cycle-labels
Add confirmed washer/dryer cycle code labels (issue #80)
2026-07-26 21:53:21 -05:00
Marc Billow 48b34c9e31 Delete test_issue_80_cycle_codes_are_labelled
Removed test for issue 80 regarding cycle codes.
2026-07-26 21:53:06 -05:00
Marc Billow 0b6eda0cdc Merge branch 'main' into claude/device-support-issue-80-cycle-labels 2026-07-26 21:51:23 -05:00
Marc Billow 285d2de397 Merge pull request #101 from mbillow/claude/device-support-issue-79-dryer
Fix dryer detection when description pairs two model numbers (issue #79)
2026-07-26 21:45:12 -05:00
Marc Billow 8b45d8cbf6 Merge branch 'main' into claude/device-support-issue-77-freezer 2026-07-26 21:40:51 -05:00
Marc Billow f3b0ef4733 Merge pull request #103 from mbillow/claude/device-support-issue-75-windfree-ac
Add humidity/temperature sensors and horizontal swing for AC (issue #75)
2026-07-26 21:37:59 -05:00
Marc Billow d20d4e2158 Merge pull request #104 from mbillow/claude/device-support-issue-74-range
Add range/oven detection for boards missing /information/vs/0 (issue …
2026-07-26 21:33:25 -05:00
Marc Billow d321fe72cd Merge pull request #94 from mbillow/claude/device-support-issue-93-ac-modes
Device support issue 93: ac modes
2026-07-26 21:30:46 -05:00
Marc Billow 9b09f1aee3 Merge pull request #70 from vmvarga/feat/wd7000b-fridge-fixes
feat: laundry firmware-flag gating, fridge vendor temp writes, course…
2026-07-26 21:25:26 -05:00
Marc Billow 45931332d4 Rework AIComfort as an HVACMode.AUTO + preset overlay, add unmapped-mode warning (issue #93)
AIComfort isn't a distinct thermodynamic operation like Cool/Dry/Heat --
it's an AI-driven overlay on top of the device's own 'Auto' behavior,
confirmed by A-CAWW-TP2-20-COMMON reporting both 'Auto' and 'AIComfort'
as separate, mutually-exclusive entries in /mode/vs/0's supportedModes.
Modeled the idiomatic HA way instead of a flat _DEVICE_TO_HVAC entry:
hvac_mode reports AUTO and a new 'ai_comfort' preset carries the
distinction. Entered/left only via the preset (writes the primary mode
resource, not the convenient one) -- there's no dedicated HVACMode
value for it, so it's not offered in the hvac_mode dropdown directly.

Also adds a once-per-(href, code) warning log when a device-reported
mode has no entry in the relevant map, so a future gap like this one
surfaces in the log instead of silently vanishing -- the exact failure
mode issue #93 called out ("this class of gap is invisible without
diffing against supportedModes").
2026-07-27 02:01:51 +00:00
Marc Billow 8c3250b163 Map AC's AIComfort mode to HVACMode.AUTO (issue #93)
A-CAWW-TP2-20-COMMON (and likely other CAWW/TP2X-class boards) reports
'AIComfort' as a distinct entry in /mode/vs/0's supportedModes,
alongside 'Auto' (already mapped to HEAT_COOL). _read_modes() silently
drops any code missing from _DEVICE_TO_HVAC, so AIComfort was
unreachable -- one of HA's five other AC hvac_modes, unused by this
device family until now.

The other two gaps in issue #93 are already addressed elsewhere and
not duplicated here:
- Fan-only via the 'Fan' device code, and the WindFree/LongWind/
  NanoSleep preset codes, are covered by the still-open PR #91, which
  replaces the static preset table with a fully dynamic resolver over
  the device's own supportedModes.
- The 'Left_And_Right' -> horizontal swing mapping is already on the
  still-open claude/device-support-issue-75-windfree-ac branch.
2026-07-27 01:43:22 +00:00
Marc Billow d53459d047 Add device support for Samsung water purifiers (issue #90)
The TP2X_WATERPURIFIER_20K water purifier reports no oneUiVersion and
its modelNum/description don't match any consumer-prefix or existing
board-family token, so it fell into the unknown-device-type fallback
with only common capabilities. Add a new water_purifier registry,
routed via a 'WATERPURIFIER' modelNum/description fallback rule.

Models dispense settings (type/temperature/capacity/pouring status),
sterilize and filter status, favorite-capacity presets, and the three
water/buzzer locks. Per the adding-device-support skill's "never
hard-code the one dump's values" rule: dispense-capacity bounds and
step come live from the device's own desiredCapacityRange/
capacityResolution fields (range_field/step_fn), not a hardcoded
constant, and the hot-water-temperature control is a select over the
live supportedHotTemperatures list rather than a number with invented
bounds, since only a few discrete temperatures are selectable.

/mode/vs/0 and /automation/waterpurifier/vs/0 are left unmodeled: the
former carries an opaque wizard-workflow token with no coherent
current-value contract, the latter is a static support-flags blob with
no live setting to expose.

Confirmed against the issue #90 diagnostics dump with zero unbound
hrefs. Updates the README's supported-appliance-types table for the
new device type.
2026-07-27 01:40:05 +00:00
Marc Billow 89429039fb Add device support for Samsung dehumidifiers (issue #88)
The AY18CG7500GED dehumidifier (modelNum TP1X_DA_AC_DHM_01001_0000)
shares the DA_AC_ board family with the room-AC models but carries the
'_DHM_' token instead of '_RAC_'/'_PRAC_'/'_WAC_', so it fell into the
unknown-device-type fallback. Add a new dehumidifier registry, routed
via a '_DHM_' modelNum fallback rule, distinct from airconditioner
since target humidity (not temperature) is the primary control and
there's no climate composite.

Reuses airconditioner.py's AUTO_CLEAN/AIR_FILTER/MUTE_ONCE capabilities
directly (identical resource shapes on the shared board family). Adds
a new humidity sensor + target-humidity number pair and an
operating-mode select. Per the adding-device-support skill's
"never hard-code the one dump's values" rule, the target-humidity
number has no hardcoded min/max (falls back to HA's own 0-100 default
for a percentage field) and reads its step live from the device's own
`increment` field rather than a spec-sheet-derived constant. The
operating-mode select's options come live from supportedModes.

/mode/convenient/vs/0 is left unmodeled: only supportedModes is present
on this dump, with no live current-value field to confirm a read/write
contract.

Confirmed against the issue #88 diagnostics dump with zero unbound
hrefs. Updates the README's supported-appliance-types table for the
new device type.
2026-07-27 01:29:25 +00:00
Marc Billow b47eeaf7bc Add device support for Bespoke Window AC (issue #87)
The AW06C7155EWAZ window air conditioner (modelNum
TP1X_DA_AC_WAC_01001_0000) reports no oneUiVersion and uses the '_WAC_'
(Window Air Conditioner) modelNum token instead of the '_RAC_'/'_PRAC_'
tokens already handled by for_device_by_model. Add a fallback rule for
that token, routing it to the existing airconditioner registry.

The device's resource surface (mode/convenient/wind/temperature/power/
filter/humidity) is already fully modeled by the airconditioner
capability set, so this is purely a detection-routing fix -- confirmed
against the issue #87 diagnostics dump with zero unbound hrefs.
2026-07-27 01:17:45 +00:00
Marc Billow a453dc9ece Add standalone induction-cooktop support (issue #86)
TP1X_DA-KS-COOKTOP-01011 (NV8500T-/KO4) is the same board family and
/cooktop/status/vs/0 resource shape as issue #44's range combo, minus
the oven -- but its modelNum uses the hyphenated '-COOKTOP-' token,
which for_device_by_model's existing '_COOKTOP' check (underscore-
delimited, matching the unrelated NA9300K gas-cooktop family in
cooktop.py) doesn't match. The device fell back to 'unknown' with only
energy/alarms from the global fallback.

Add the hyphenated token check, routing to a new 'induction_cooktop'
registry (by_type/induction_cooktop.py) that reuses range.py's
COOKTOP_STATUS/COOKTOP_SPEC/COOKTOP_SAFETY/PROBE_STATUS and
cooktop.PAIRED_HOOD_STATUS wholesale rather than pulling in range.py's
oven capabilities, which this device has no hrefs for at all.

Along the way, three fields the reporter asked for turned out to be
gaps in the shared range.py capability itself, not just missing
routing -- also present (and previously unmodeled) on issue #44's
original combo-range dump:
- /cooktop/status/vs/0's own `power` and `childLock` fields (distinct
  from common.POWER's /power/0 or /power/vs/0, which a combo range
  additionally carries for the whole appliance) -- childLock gets a
  write_fn (a safe lock toggle, direct single-field PUT), power stays
  read-only (no live device to confirm a remote write wouldn't leave a
  burner active unattended).
- Each burner's `panDetection` field.

New: a Bluetooth meat-probe capability for /bluetooth/probe/status/vs/0
(read-only -- connection, battery, current/target temperature), and
/cooktop/recipe/status/vs/0 is ignored (every field empty on this idle
dump, same treatment as the microwave family's /recipe/cook/vs/0).

Regenerates the range golden fixture (gains cooktop_power/
cooktop_child_lock/burner_N_pan_detected) and adds a dedicated fixture
for the standalone cooktop.
2026-07-27 01:12:16 +00:00
Marc Billow 2c9fda3db1 Catch the 'Nothing(SVC)' placeholder serial in both fallback sites (issue #83)
The ARTIK051_DONGLE_REF firmware family reports the literal string
"Nothing(SVC)" as serialNum on every unit -- non-empty, so the existing
`if not serial` checks in config_flow.py's _probe_and_validate and
coordinator.py's _run_discovery don't catch it. Two such appliances on
one install (a fridge and a freezer, each its own dongle) then collide:
config_flow gives both the same unique_id and rejects the second as
"already configured" (bug 2), and even once that's worked around,
device_serial feeds every entity's unique_id too, so the second
appliance's entities get silently dropped with "does not generate
unique IDs" log lines (bug 4).

Add _is_placeholder_serial (duplicated in both modules rather than
imported, to avoid pulling config_flow into the runtime coordinator's
import graph or vice versa for a two-line check) and treat it the same
as an empty serial: fall back to host/port.

Type detection (bug 1) and the door sensor's field-name gap (bug 3),
also reported in this issue, are already fixed via the
claude/device-support-issue-77-freezer branch, which hit the same
ARTIK051_DONGLE_REF family from a different report -- not duplicated
here.
2026-07-27 01:00:05 +00:00
Marc Billow 5d7789eb4e Add confirmed washer/dryer cycle code labels (issue #80)
Five raw course codes were rendering unlabeled because no translation
entry existed for them, confirmed by the reporter selecting each cycle
on the physical appliance and reading back the raw code from the
entity's state:

- washer_cycle_table_02: '52' Eco Cold, '54' Towels, '60' Self Clean+
  (a WF50A8600AV/US). '54' shares a display name with the existing '24'
  Towels -- a different code on the same table legitimately landing on
  the same label, matching the existing '21'/'65' Colors and
  '27'/'5E' Rinse+Spin pairs, not a duplicate-in-error.
- dryer_cycle_table_03: '01' Normal, '06' Time dry (a DVE50A8600V/A3,
  the same model added in the previous commit's detection fix).

No code changes -- select.py already derives which raw values it
normalizes from the shipped catalog, so labelling a code is purely a
translations/en.json (mirrored to nl.json) addition.
2026-07-27 00:47:16 +00:00
Marc Billow bae1ac4337 Fix dryer detection when description pairs two model numbers (issue #79)
DVE50A8600V/A3 reports description
'DA_WM_TP1_21_COMMON_DVE50A8800_8600/DC92-02835A_0080' -- a paired
listing of two related model numbers (DVE50A8800 and DVE50A8600) joined
by an underscore, rather than the usual single trailing consumer-model
token. for_device_by_model only ever checked the literal last
underscore segment ('8600', which has no recognizable 2-letter prefix
on its own), so the real 'DV' token one segment earlier was never
reached and the device fell back to 'unknown' with only common
capabilities -- no dry level, cycle, or wrinkle-prevent entities.

Replace the single last-segment extraction with _consumer_model_key,
which scans segments from the end and returns the first one that
resolves. Behavior is unchanged for every existing single-token
description (the last segment still matches first); it just keeps
looking when that segment doesn't.
2026-07-27 00:44:23 +00:00
Marc Billow 643aac92f8 Lock in the same ARTIK051_DONGLE_REF fix for the fridge half (issue #78)
RR40M7165WW is the fridge half of the same household dongle setup as
issue #77's freezer -- identical pipe-delimited ARTIK051_DONGLE_REF
modelNum, so the previous commit's detection and door-sensor fixes
already cover it with no further code changes. Add its fixture as a
second, independent regression case: it exercises the 'cooler' instance
segment instead of 'freezer' for both the temperature pattern caps and
DOOR_GENERIC, and notably reports /door/onedoorfreezer/vs/0 despite
being a single-door fridge (shared firmware naming across the product
line, not an actual second compartment) -- worth having its own golden
so that stays working too.
2026-07-27 00:41:25 +00:00
Marc Billow 8194ea9e87 Fix ARTIK051_DONGLE_REF freezer type detection and door sensor (issue #77)
RZ32M713EWW/EE (an ARTIK051-dongle standalone freezer) reports no
oneUiVersion and a pipe-delimited modelNum
('ARTIK051_DONGLE_REF|<rest>') -- REF is the last underscore segment
before the pipe, not wrapped in underscores on both sides like the
'..._REF_...' shape for_device_by_model's substring check expected, so
the device fell through to 'unknown' with only common capabilities:
no door sensor, no temperature sensors, nothing fridge-specific.

Replace the substring check with a segment-based one
(_model_num_segments splits the pipe-delimited prefix on '_') that
catches both shapes. Same root cause, same fix, and same device family
independently reported and root-caused in issue #83 (which also covers
two further bugs -- config-flow/coordinator serial collisions on a
second symptom of this firmware, 'Nothing(SVC)' as a literal serial --
not needed here since this reporter has a single unit; left for #83).

Once routed to the refrigerator registry, fridge.py's existing pattern
capabilities pick up /temperature/current/freezer/0 and
/temperature/desired/freezer/0 for free -- they were never the actual
problem, just unreachable under the 'unknown' fallback (which never
tries pattern capabilities at all). The door sensor needed one more
fix: /door/onedoorfreezer/vs/0 reports the vendor-prefixed
x.com.samsung.da.openState, not the bare openState DOOR_GENERIC read,
so the entity existed but stayed permanently unavailable. Check both
field names via rep_fn.
2026-07-27 00:39:33 +00:00
Marc Billow 3afbe6c6c1 Add humidity/temperature sensors and horizontal swing for AC (issue #75)
Three gaps reported against an ARTIK051_PRAC_20K WindFree unit vs. the
SmartThings integration:

1. Missing WindFree/motion convenient-mode presets -- left alone here.
   PR #91 replaces climate.py's static _DEVICE_TO_PRESET table with a
   generic resolver that reads any preset code straight off the unit's
   own supportedModes, which already covers this (and more generically
   than a per-model dict would) -- adding one here would just conflict.

2. No horizontal oscillation: /wind/direction/vs/0's supportedModes
   includes Left_And_Right, which _DEVICE_TO_SWING had no mapping for.
   Add it to HA's standard 'horizontal' swing constant.

3. No standalone humidity/current-temperature sensors: the climate card
   already reads both internally, but nothing exposed them as entities
   for history/automations. Add CURRENT_TEMPERATURE (OCF
   /temperature/current/0) with a CURRENT_TEMPERATURE_VS vendor fallback
   (same match_fn-gated pair shape as common.py's POWER_GENERIC/
   POWER_VS_FALLBACK), and a HUMIDITY sensor reading /humidity/vs/0's
   fivepercentHumidity field -- the only one of the three
   humidity-shaped fields across /humidity/0 and /humidity/vs/0 that
   isn't permanently stuck at 0 on every dump seen.

Regenerates the five existing AC goldens (all pick up
current_temperature_c; most pick up humidity) and adds a dedicated
fixture from the issue's WindFree dump, whose /humidity/vs/0 actually
has live fivepercentHumidity data.
2026-07-27 00:33:35 +00:00
Marc Billow c72b5a988e Add range/oven detection for boards missing /information/vs/0 (issue #74)
NE63B8411SS reports no oneUiVersion and no /information/vs/0 resource at
all, so neither for_device nor for_device_by_model's modelNum tokens have
anything to key off -- it fell through to the unknown-device fallback,
which also mis-binds /temperatures/vs/0 against fridge.py's setpoint
capability (a collision the oven family's own capabilities are normally
excluded from the global registry specifically to avoid).

Add a resources-based signature to for_device_by_resources(): 'Bake' in
/mode/vs/0's supportedModes is oven/range-exclusive vocabulary, and paired
with the /oven/vs/0 cavity resource it reliably identifies this family
even with no model info at all. Route to 'range' when a cooktop-status
resource is also present, else plain 'oven'.

This board's cooktop half also doesn't expose the per-burner
/cooktop/status/vs/0 array range.py already models -- only the coarser
/cooktopmonitoring/vs/0 summary resource. Add a read-only
COOKTOP_MONITORING capability for it (cooktop running state, warming
center state) rather than leaving it unbound.
2026-07-27 00:23:04 +00:00
vmvarga 2fd8ff8260 merge temp_setpoint 2026-07-26 11:05:13 +02:00
vmvarga 00cf8d676d feat: laundry firmware-flag gating, fridge vendor temp writes, course names 2026-07-25 10:01:56 +02:00
Marc Billow aff7647460 Merge pull request #65 from Metal-Eagle/feature/add-completion-time
Feature/add completion time
2026-07-24 23:46:47 -05:00
Jeroen Hof 705da781f1 Merge branch 'main' into feature/add-completion-time 2026-07-25 06:41:17 +02:00
Jeroen Hof 6de1a4090e i18n: simplify completion time translation in English and Dutch 2026-07-25 06:02:45 +02:00
Jeroen Hof ef75db6697 i18n: update completion time translation in English and Dutch 2026-07-25 05:55:47 +02:00
Jeroen Hof 9e290f27ee refactor: update sensor descriptions for completion time and delay start 2026-07-25 05:24:10 +02:00
Jeroen Hof 37bfff152d refactor: remove unused strings.json file 2026-07-25 05:15:34 +02:00
Jeroen Hof 317b7d0c1b fix: add missing newline at end of en.json file 2026-07-25 05:09:55 +02:00
Jeroen Hof ba8e41d310 Implement code changes to enhance functionality and improve performance 2026-07-25 05:08:18 +02:00
Jeroen Hof 724686c42c i18n: add translations for AI Wash and Jeans 2026-07-25 05:01:40 +02:00
Jeroen Hof edccb6ae3f i18n: add new wash options for AI Wash and Jeans 2026-07-25 04:59:37 +02:00
Jeroen Hof 4a91f62a36 i18n: add new translations for AI Wash and Spijkerbroek 2026-07-25 04:49:40 +02:00
Jeroen Hof 1d4d38db14 Merge branch 'main' into feature/add-completion-time 2026-07-25 04:47:22 +02:00
Marc Billow 35e2c79b14 brand: use updated localthing logo 2026-07-24 20:23:48 -05:00
Marc Billow f185951a8a i18n: missed a quick wash translation 2026-07-24 15:42:24 -05:00
Marc Billow adcb8a0ecb chore: add additional translations provided in #1 dutch 2026-07-24 15:33:31 -05:00
Marc Billow dc86c7f0ef Merge pull request #72 from mbillow/claude/home-assistant-i18n-iwwyvr
feat (i18n): refactor and improve translation support
2026-07-24 15:23:39 -05:00
Marc Billow 30d38d855c Merge branch 'main' into claude/home-assistant-i18n-iwwyvr 2026-07-24 15:23:10 -05:00
Marc Billow ee77e3bda8 chore: add additional translations provided in #1 2026-07-24 15:20:19 -05:00
Marc Billow 10c850f2b9 refactor(i18n): drop the vestigial descriptor name field
Since entity.py started routing named descriptors through the catalog
under desc.key, SamsungEntityDescription.name has been read for its
value nowhere -- only twice as a flag, to decide whether an entity was
translated at all. That left 148 English names duplicated between Python
and translations/en.json with nothing keeping them honest: six had
already drifted, invisibly, because editing the Python side changes
nothing a user sees.

So the field is gone, and translation_key defaults to desc.key. A
descriptor now sets translation_key only to share one catalog entry
across descriptors or to point at a differently-named one, and the
catalog is the only place an entity name exists.

Every descriptor resolves to exactly the translation key, icon, entity
category, enabled-default and gating it did before -- with one
deliberate exception: the hood fan, previously the sole descriptor with
no key at all, now resolves to 'fan'. That is inert, because fan.py sets
_attr_name = None so the entity presents as the device itself.

The three helpers that forwarded a name into a descriptor
(laundry.bool_option_switch, washer._bool_option_switch, air_purifier's
sensor table) lose that parameter. test_translations.py now requires a
catalog entry for every descriptor rather than only translated ones.

Claude-Session: https://claude.ai/code/session_01GiibJZZLWVvyxq7mc7EDNp
2026-07-24 19:45:37 +00:00
Marc Billow 6281b40549 refactor(i18n): make the shipped catalog the single source of truth
PR #68 restated its own translation data in Python: a 60-line
TRANSLATED_SELECT_STATES table of frozensets duplicating every
entity.select.*.state key, a second _TRANSLATED_COURSE_TABLES table
naming which course tables have translations, and a strings.json that
was a 835-line byte-for-byte copy of translations/en.json save 43
[%key:...%] references. Each needed hand-syncing, and one was already
drifting.

Home Assistant loads exactly one file per language for a custom
integration -- translations/<lang>.json. It never reads strings.json and
never resolves [%key:...%]; both belong to Core's build tooling, which
custom integrations don't run through (hassfest skips a missing
strings.json and validates translations/en.json instead). So en.json is
the source, and the new catalog.py reads the keys and states back out of
it for the two decisions Python genuinely has to make:

  - select._display() normalizes a raw Samsung option to a lowercase
    state key only when the catalog knows it, else leaves the vendor's
    casing alone. Derived sets are identical to the removed literals.
  - laundry.cycle_select() keys off a device-reported course table only
    when that table has an entry, else falls back to the name-only
    'cycle' key. Translating Table_00 is now a translations-only change.

Also fixes six names that had already drifted between the Python
descriptors and the catalog, restoring HA's sentence case for two
generic ones (Auto release dry, Bubble soak) and taking the catalog's
wording for the rest, and adds a test so the vestigial descriptor names
can't silently disagree with the UI again.

Claude-Session: https://claude.ai/code/session_01GiibJZZLWVvyxq7mc7EDNp
2026-07-24 19:32:09 +00:00
Marc Billow 0b6cc6aa9f Merge branch 'pr68' into claude/home-assistant-i18n-iwwyvr 2026-07-24 19:24:59 +00:00
Hmmbob 5d86dbe7e8 Resolve runtime translation references 2026-07-24 21:13:07 +02:00
Hmmbob 82acc05d38 Limit changes to translation support 2026-07-24 18:40:44 +02:00
Hmmbob da49825e2e Harden unknown vendor value fallbacks 2026-07-24 18:12:01 +02:00
Hmmbob b85af10ae1 Test translation coverage and dynamic fallbacks 2026-07-24 18:08:29 +02:00
Hmmbob f9ebc8e286 Make LocalThings UI fully translatable 2026-07-24 18:08:29 +02:00
Hmmbob d0cfaeebc1 Add Dutch translations 2026-07-24 17:29:50 +02:00
Jeroen Hof 365a1c4722 feat: enhance operational capabilities by adding completion_minutes and updating related logic; remove completion_time references 2026-07-24 15:35:17 +02:00
Jeroen Hof 7be91b56e8 Merge remote-tracking branch 'upstream/main' into feature/add-completion-time 2026-07-24 08:23:42 +02:00
Jeroen Hof 2c283218b0 feat: add completion_minutes and completion_time to state_keys in JSON fixtures 2026-07-24 08:10:17 +02:00
Jeroen Hof ab874797fc Merge branch 'main' into feature/add-completion-time 2026-07-24 07:48:57 +02:00
Jeroen Hof f5d4e2219a fix: remove redundant course codes from parse_edit_course_list test case 2026-07-24 07:47:53 +02:00
Jeroen Hof 86f07abf30 fix: correct expected output for parse_edit_course_list test case 2026-07-24 06:29:53 +02:00
Jeroen Hof b00390c093 fix: correct key for Jeans cycle in strings and translations 2026-07-24 06:27:28 +02:00
Jeroen Hof e913a3c2c0 feat: add new washer cycle options for AI Wash and Jeans 2026-07-24 06:26:24 +02:00
Jeroen Hof b2db4bf357 feat: add completion time and minutes sensors with parsing logic 2026-07-24 06:23:53 +02:00
186 changed files with 23021 additions and 1346 deletions
+170 -17
View File
@@ -5,7 +5,10 @@ description: >-
/device/0 diagnostics dump. Use when a device-support issue lands, a device
raises the "incomplete capability coverage" repair, a diagnostics JSON needs
triaging, or you're mapping OCF resources to HA entities. Covers reading dumps,
routing an unrecognized board family to a registry (modelNum board tokens,
resource signatures),
OCF-standard vs vendor hrefs, the diagnostic/config/normal entity taxonomy,
preferring dynamic (device-reported) select options over hardcoded lists,
ensuring every href is bound or ignored, and locking it in with a fixture +
golden + test.
---
@@ -46,9 +49,7 @@ discovery = importlib.import_module('custom_components.localthings.registry.disc
adapter = importlib.import_module('custom_components.localthings.registry.adapter')
resources = json.load(open('dump.json'))['data']['resources']
info = resources['/information/vs/0']
reg = by_type.for_device_by_model(info['x.com.samsung.da.modelNum'], info['x.com.samsung.da.description'])
# or: by_type.for_device(one_ui_version) when /otninformation has swVersionInfo.oneUiVersion
reg = by_type.resolve(resources) # the same entry point the coordinator uses
unbound = []
bound = discovery.discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
state = adapter.flatten(bound, resources) # {entity_key: value}
@@ -60,7 +61,95 @@ print('state_keys:', sorted(state))
`exists_fn` and produces the final entity values. Use the same routine to
regenerate a golden.
## 3. OCF-standard vs vendor hrefs (`/x/0` vs `/x/vs/0`)
## 3. Route the device to a registry — add a row, never a branch
If detection returns `None`, the device falls back to common capabilities and
loses roughly **half** its entities (measured across the fixture corpus: 843 of
1510 bound entities survive). So routing is the first thing to fix, and
`registry/by_type/__init__.py` is deliberately kept boring.
`resolve(resources)` is the only entry point — the coordinator, the config
flow's probe and the golden-regression harness all call it, so the order can't
drift between what ships and what the tests assert. Two stages:
1. **`for_device_by_model(model_num, description)`** — the primary path. Both
fields come from `/information/vs/0`. Board-family tokens are matched
against `modelNum` first, then `description`, then the fuzzy two-letter
consumer-model prefix.
2. **`for_device_by_resources(resources)`** — for boards that report no
`/information/vs/0` at all. Needs a *distinctive* signature.
**`oneUiVersion` is not consulted.** It looks like the obvious signal — the
device naming its own type, `'7.0 Dishwasher'` — and it used to be stage one.
But only a minority of hardware reports it, every device that does is already
typed by its modelNum board token (`TestOneUiVersionIsNotConsulted` checks that
against the whole corpus), and no device-support issue was ever fixed by adding
a mapping for it. Don't reintroduce it as a detection stage; it stays in
diagnostics as a firmware-generation marker (`'7.0 Air conditioner'` means
Tizen Lite), which is useful when triaging.
### Adding a board family
Almost always a one-line addition to `_BOARD_TOKEN_TO_KEY`:
```python
'VSKR': 'vacuum_station', # issue #131 -- stick-vacuum clean station
```
Matching is on **whole tokens** of the model string, split on any run of
non-alphanumerics and upper-cased. That is what keeps this a table, and it
carries rules:
- **Never add a delimiter spelling.** `'_RAC_'` and `'-RAC-'` are the same
entry, `RAC`. If you find yourself adding a second row for punctuation, the
tokenizer already handled it.
- **Name the specific type, never the board family.** `DA-AC-` prefixes
RAC/WAC/DHM/AIR alike — a bare `'AC'` row would swallow the dehumidifier
and the air purifier. Same for `DA`, `KS`, `WM`, `TP1X`, `ARTIK051`.
`TestBoardTokenTable` asserts these stay out.
- **Never add a token that can co-occur with another.** `_board_family_key`
returns the first hit, which is only safe while no real model string
contains two tokens naming different types.
`TestBoardTokenAmbiguity` checks that invariant against every fixture, so a
new dump exercises it automatically — if it fails, the answer is a narrower
token, not a reordering.
- **Two-letter tokens are a last resort.** `'CT'` (legacy gas cooktop) is the
only one, and it is loose enough to collide by accident.
Reach past the table only when the evidence isn't a board token:
- **Consumer-model prefix** (`_CONSUMER_PREFIX_TO_KEY`) — for washers, dryers
and dishwashers, whose `modelNum` is the shared `DA_WM_` laundry board and
whose real type is only in `description`'s trailing model code
(`..._WA8000T`). Deliberately split on `_` only: widening it to `-` would
read the dishwasher's `ADW-WW-RTL-24-AILITE` board segment as a `WW`
washer. Consulted last because a two-letter prefix is the weakest evidence
here — `WAC` (window AC) starts with `WA` (top-load washer).
- **Resource signature** (`for_device_by_resources`) — only when
`/information/vs/0` is absent entirely. Require **two** independent shapes
(e.g. `/oven/vs/0` present *and* a `MicroWave*` entry in `supportedModes`),
never one, or an unrelated family's `/mode/vs/0` will match.
### If the model string identifies nothing
Check the diagnostics `identity` block before inventing a rule: it carries
`/oic/p` and `/oic/d`, which sit outside the `/device/0` dump.
`identity.device_types` is `/oic/d`'s `rt` — OCF's own device-type
declaration (`oic.d.airconditioner`). Nothing routes on it yet because no
captured dump has ever included it; if real hardware turns out to populate it,
it beats parsing board part numbers and this whole section shrinks. Note in
the issue when a dump has it.
### Sharing a registry vs adding one
Route a new family to an **existing** registry when its resource surface
matches (most AC board families do — verify by checking the dump binds with
zero unbound hrefs). Add a **new** registry only when the resources genuinely
differ: `vacuum_station` earned one because it shares no hrefs with anything
modelled; `microwave` split from `oven` over a distinct mode vocabulary,
setpoint bounds, and a `powerLevel` field.
## 4. OCF-standard vs vendor hrefs (`/x/0` vs `/x/vs/0`)
Samsung appliances run RT-OCF and often expose the **same state twice**:
- `/x/vs/0` — **vendor** resource, `x.com.samsung.da.*` fields.
@@ -82,7 +171,7 @@ resource from the populated dump:
Course/cycle is **not** an OCF question — there's no standard course resource, so
`/course/vs/0` (and the `/st/*course/vs/0` re-encoding) are both vendor.
## 4. Entity taxonomy — the judgement call
## 5. Entity taxonomy — the judgement call
For each field worth exposing, decide the entity kind and category
(`entity_category` on the descriptor):
@@ -103,18 +192,76 @@ sub-polled between summary polls. Pick descriptor types from `entities.py`
as a gap for a human, or ignore it with a documented reason — never invent an
entity on a hunch (`ignored.py`'s rule).
## 5. Enum selects need translation support
## 6. Select options: read them from the device, don't hardcode
Any select whose options are raw device codes (course/cycle, and code-valued
settings) must render through translations, not Python:
- Set `translation_key='<family>_cycle'` (or similar) on the `SelectDesc`;
`options`/`options_field` supply the **raw** codes.
- Add the labels to **both** `strings.json` and `translations/en.json` under
`entity.select.<translation_key>.state.<code>`, with the code **lowercased**
(e.g. `"16": "Cotton"`). Codes with no entry render as the raw code — that's
the cue to identify and name them.
A `SelectDesc`'s `options` should come from the device's own advertised list
whenever the resource carries one, not from a Python tuple typed in from a
single dump. Two dynamic forms already exist in the repo and should be
reached for first:
- `options_field='x.com.samsung.da.supportedModes'` (or whatever the
resource's own supported-values field is called) — reads the live rep on
the capability's own href. See `laundry.py`'s `buzzer_sound`/
`finish_sound` (`options_field='supportedBuzzerSound'`/
`'supportedFinishSound'`).
- `options=<callable>` — for option lists that live on a **different**
resource than the select's own href (e.g. a course table keyed off a
sibling href). See `laundry.cycle_select`'s `options=cycle_options`.
## 6. Coverage discipline: bound or ignored
A static `options=(...)` tuple is a coverage gap waiting to happen: the next
dump from a different board generation will report modes/values the tuple
doesn't have, and both the HA options list *and* `write_fn`'s validation (if
it checks the same tuple) will silently reject values the device itself
advertises as supported. That's exactly what happened with `oven._OVEN_MODES`
in issue #138 — a hardcoded list rejected `AirFryer`/`Dehydrate`/
`SelfClean`/etc. even though the device's own `supportedModes` field listed
them. Reach for a static tuple only when the dump genuinely has no
supported-values field to read (e.g. the NV7000BS-class oven dump
`_OVEN_MODES` was inferred before any live oven dump existed — see that
module's docstring), and treat it as an interim best-guess rather than a
permanent design choice: migrate it to `options_field`/a callable the moment
a dump with a real supported-values list surfaces, instead of just adding
the new values to the static tuple.
## 7. Names and enum labels live in translations, never in Python
Descriptors have **no `name` field**. Every entity is named from the shipped
catalog, keyed by `translation_key` — which defaults to the descriptor's own
`key`. So adding `SensorDesc(key='filter_status', ...)` obliges you to add:
```json
"entity": { "sensor": { "filter_status": { "name": "Filter status" } } }
```
to `translations/en.json`. Skip it and the entity ships nameless;
`tests/test_translations.py` fails the build instead.
- **Sentence case** ("Filter status", not "Filter Status"), per HA's style
guide — capitalize only proper nouns and Samsung feature names ("AI Energy
Mode", "Storm Wash+").
- Set `translation_key` explicitly only to **share** one catalog entry across
descriptors, or to point at a differently-named one. Two descriptors on the
same platform with the same `key` already share an entry — intended for
`common.py`'s OCF/vendor fallback pairs, a silent mislabel otherwise.
- Prefer HA's own vocabulary where it fits: a `device_class` gives you
translated states for free (`binary_sensor` door/running, `sensor`
timestamp/enum), so don't restate them.
Selects whose options are raw device codes (course/cycle, code-valued
settings) additionally need those codes labelled:
- `options`/`options_field` supply the **raw** codes; the catalog maps them.
- Add labels under `entity.select.<translation_key>.state.<code>`, code
**lowercased** (e.g. `"16": "Cotton"`). `select.py` derives which values it
normalizes from the catalog itself, so there is no Python list to keep in
sync — a code with no entry simply renders as the raw code, which is the cue
to identify and name it.
`translations/en.json` is the only place any of this lives: there is no
`strings.json` (Home Assistant doesn't read one from a custom integration) and
no `[%key:...%]` resolution (that's Core build tooling). Every other language
must mirror `en.json` key for key — also enforced by
`tests/test_translations.py`.
## 8. Coverage discipline: bound or ignored
Every href in the dump must resolve, or the repair fires. If a resource isn't
worth an entity, add it to `capabilities/ignored.py` (a no-entity `Capability`)
@@ -128,7 +275,7 @@ friendlier href**.
ignored because washers bind it. When only one family should ignore an href
that another binds, scope the ignore to that family's registry.
## 7. Reuse before writing new code
## 9. Reuse before writing new code
Check `common.py` (generic OCF: power, energy, alarms, water) and `laundry.py`
(shared washer/dryer/dishwasher: buzzer, job status, `cycle_select` + course
@@ -137,7 +284,7 @@ registry uses `fridge.FIRMWARE_UPDATE`; all three laundry families share
`laundry.cycle_select`. If two families hand-roll the same helper, hoist it to a
shared module rather than copying.
## 8. Lock it in
## 10. Lock it in
1. Add a **scrubbed** fixture `tests/fixtures/<type>_device.json`
(`{"device0": [ {devcol rep}, {href, rep}, ... ]}`) — replace serials, MACs,
@@ -150,6 +297,12 @@ shared module rather than copying.
4. Run `pytest tests/ -q` — and re-run the golden tests for **other** device
types after any change to `common.py`/`laundry.py`, since they share those.
The new fixture is picked up automatically by the corpus-wide checks (the
`all_device_fixtures` conftest fixture), including
`TestBoardTokenAmbiguity` — so a model string that collides with an existing
board token fails the build rather than silently mistyping someone's
appliance.
## Key files
- `registry/discovery.py` — `discover()`, unbound reporting, pattern caps.
- `registry/capability.py`, `registry/entities.py` — the `Capability` and
+35 -6
View File
@@ -1,3 +1,21 @@
<!-- dark mode -->
<img src="custom_components/localthings/brand/dark_logo@2x.png#gh-dark-mode-only" alt="LocalThings Logo"/>
<!-- light mode -->
<img src="custom_components/localthings/brand/logo@2x.png#gh-light-mode-only" alt="LocalThings Logo"/>
<p align="center">
<img alt="GitHub Repo stars" src="https://img.shields.io/github/stars/mbillow/localthings" />
<img alt="GitHub watchers" src="https://img.shields.io/github/watchers/mbillow/localthings" />
</p>
<p align="center">
<img alt="GitHub Release" src="https://img.shields.io/github/v/release/mbillow/localthings" />
<img alt="hacs validation" src="https://img.shields.io/github/check-runs/mbillow/localthings/main?nameFilter=HACS%20validation&label=hacs%20validation" />
<img alt="hassfest" src="https://img.shields.io/github/check-runs/mbillow/localthings/main?nameFilter=Hassfest%20validation&label=hassfest" />
<img alt="tests" src="https://img.shields.io/github/check-runs/mbillow/localthings/main?nameFilter=Pytest&label=tests" />
</p>
# LocalThings
**A native Home Assistant custom integration for local control of newer-generation Samsung connected appliances.** No cloud round-trip. Add a device through HA's normal *Settings > Devices & Services* flow and it talks CoAP-over-DTLS straight to the appliance on your LAN.
@@ -18,14 +36,19 @@ Your state stays on your LAN: HA talks to the appliance over a direct DTLS sessi
|---|---|
| Air conditioner | `by_type/airconditioner.py` |
| Air purifier | `by_type/air_purifier.py` |
| Dehumidifier | `by_type/dehumidifier.py` |
| Dryer | `by_type/dryer.py` |
| Oven | `by_type/oven.py` |
| Cooktop (read-only burner status) | `by_type/cooktop.py` |
| Microwave | `by_type/microwave.py` |
| Gas cooktop (read-only burner status) | `by_type/cooktop.py` |
| Range hood | `by_type/range_hood.py` |
| Range | `by_type/range.py` |
| Dishwasher | `by_type/dishwasher.py` |
| Refrigerator | `by_type/refrigerator.py` |
| Washer | `by_type/washer.py` |
| Water purifier | `by_type/water_purifier.py` |
| Vacuum clean/auto-empty station | `by_type/vacuum_station.py` |
| Air dresser | `by_type/air_dresser.py` |
Each registry composes shared and family-specific `Capability` objects from `registry/capabilities/`; those modules document the individual resources/entities in more depth than a README table can stay current with.
@@ -82,12 +105,13 @@ The `Dockerfile` builds on the official `home-assistant/home-assistant:stable` i
### Tests
```sh
python3 -m venv .venv
python3.13 -m venv .venv # 3.13 or newer; see below
.venv/bin/pip install -r requirements-dev.txt
.venv/bin/pip install pytest-homeassistant-custom-component homeassistant
.venv/bin/pytest tests/ -q
```
`requirements-dev.txt` already pulls in Home Assistant and pytest at matching versions, so there's nothing to install alongside it. Use Python 3.13 or newer: pip resolves the newest `pytest-homeassistant-custom-component` your interpreter supports, and on 3.12 or older nothing resolves and the install fails outright. CI runs 3.14.
A large suite covering registry composition, discovery, entity descriptors, and golden-file regression against captured device dumps. `requirements-dev.txt` pins `smartthings-local` the same way `manifest.json` does, so tests exercise the real published protocol layer rather than a vendored copy.
---
@@ -106,14 +130,17 @@ custom_components/localthings/
entity.py Base entity wiring capability registry -> HA entity
sensor.py / binary_sensor.py / switch.py / number.py / select.py / button.py / time.py / fan.py / climate.py
One module per HA platform
strings.json / translations/ Config-flow copy + entity state translations
catalog.py Reads the shipped translation catalog (which keys/states exist)
translations/ Config-flow copy + entity name/state translations, one file per
language; en.json is the source of truth (no strings.json —
Home Assistant never reads one from a custom integration)
registry/
registry.py Builds the global capability registry, validates href collisions
capability.py Capability dataclass (href, entities, transforms)
entities.py Per-platform entity descriptor dataclasses
discovery.py Binds a device's live resources to registered capabilities
adapter.py Flattens bound entities into HA-ready state
identity.py Reads device identity for type detection
identity.py Reads /oic/p + /oic/d (manufacturer, model, OCF device type)
redact.py Strips account/identity data before diagnostics leave HA
capabilities/ Shared + per-family Capability definitions (common, airconditioner,
cooktop, range_hood, dryer, oven, dishwasher, fridge, washer,
@@ -143,7 +170,9 @@ support for hardware the maintainers don't have.
1. Get a capture of the appliance's `/device/0` response. The easiest way: add the device to HA (type detection failing is fine) and pull its Diagnostics download from Settings > Devices & Services > the device > the menu > Download diagnostics — it already contains a redacted dump of the device's resources.
2. Reuse existing `Capability` objects from `registry/capabilities/` wherever the resource matches one already declared. Most `common.py` capabilities (power, kids lock, remote control, alarms, energy/water meters) are shared verbatim across families; add new ones only for resources unique to the new type.
3. Create `registry/by_type/<name>.py` with a `DeviceRegistry(name=..., capabilities=_build([...]))`. Use `pattern_capabilities` instead of `capabilities` for any resource whose `href` isn't fixed (for example per-compartment fridge resources); see `refrigerator.py` for the pattern.
4. Register it in `_REGISTRY_BY_KEY` in `registry/by_type/__init__.py`, keyed on the lowercased, space/hyphen-to-underscore-converted suffix of the device's `oneUiVersion` string (see `_type_key()` in that file for the exact transform). If the device never reports `oneUiVersion`, add its consumer-model prefix to `_CONSUMER_PREFIX_TO_KEY` so `for_device_by_model()` can route it. If it also omits `/information/vs/0` (as the verified NA9300K cooktop does), add a distinctive, conservative resource-signature rule to `for_device_by_resources()`.
4. Register it in `_REGISTRY_BY_KEY` in `registry/by_type/__init__.py`, then route devices to it by adding the board-family token from their `modelNum` to `_BOARD_TOKEN_TO_KEY` — a single row, e.g. `'VSKR': 'vacuum_station'`. Tokens are matched whole (the model string is upper-cased and split on any run of non-alphanumerics), so one entry covers every delimiter spelling Samsung uses: `TP1X_DA-AC-RAC-01001` and `TP2X_RAC_20K` both resolve on `RAC`. Name the specific type, never the board family that contains it — `DA-AC-` prefixes RAC/WAC/DHM/AIR alike, so a bare `AC` row would swallow the dehumidifier and the air purifier. If the board is shared across types (washers and dryers both report `DA_WM_`), add the consumer-model prefix from `description` to `_CONSUMER_PREFIX_TO_KEY` instead. If the device omits `/information/vs/0` entirely (as the verified NA9300K cooktop does), add a distinctive, conservative resource-signature rule to `for_device_by_resources()`.
`oneUiVersion` is deliberately not consulted — see `resolve()` in that file for why.
5. Add golden-file coverage in `tests/` against a captured `/device/0` dump for the new type.
No config-flow changes are needed. Device-type detection and entity wiring are fully driven by the registry.
Binary file not shown.

Before

Width:  |  Height:  |  Size: 5.2 KiB

After

Width:  |  Height:  |  Size: 32 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 10 KiB

After

Width:  |  Height:  |  Size: 90 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 25 KiB

After

Width:  |  Height:  |  Size: 52 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 47 KiB

After

Width:  |  Height:  |  Size: 139 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 5.3 KiB

After

Width:  |  Height:  |  Size: 32 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 10 KiB

After

Width:  |  Height:  |  Size: 90 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 30 KiB

After

Width:  |  Height:  |  Size: 54 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 62 KiB

After

Width:  |  Height:  |  Size: 146 KiB

+49
View File
@@ -0,0 +1,49 @@
"""The integration's own shipped translation catalog, as data.
Home Assistant loads exactly one file per language for a custom integration:
``translations/<lang>.json``. It does not read ``strings.json`` and it does
not resolve ``[%key:...%]`` references -- both of those belong to Core's
build tooling (``script/translations``), which custom integrations never run
through. So ``translations/en.json`` is not a generated artifact here, it is
the source of truth, and English is the one catalog required to be complete
(hassfest validates it for custom integrations).
That makes the English catalog the authority on *which* translation keys and
states exist, which is something the Python side genuinely needs to know:
* ``select`` has to decide whether to normalize a raw Samsung option into
a lowercase state key (so Home Assistant can look it up) or leave the
vendor's own casing alone as a readable fallback.
* ``laundry.cycle_select`` has to decide whether a device-reported course
table has translations at all before keying off it.
Reading it from the catalog instead of restating it in Python means adding a
state or a course table is a one-file change, and the two can't drift.
"""
from __future__ import annotations
import json
from pathlib import Path
# Read at import, not lazily: custom integrations are imported in an executor
# thread, so this stays off the event loop no matter who asks first.
_ENTITY_CATALOG: dict[str, dict[str, dict]] = json.loads(
(Path(__file__).parent / 'translations' / 'en.json').read_text(encoding='utf-8')
).get('entity', {})
def has_entity_translation(platform: str, translation_key: str) -> bool:
"""Whether `platform`.`translation_key` has an entry in the catalog."""
return translation_key in _ENTITY_CATALOG.get(platform, {})
def translated_states(platform: str, translation_key: str) -> frozenset[str]:
"""The state keys translated for `platform`.`translation_key`.
Empty when the entity has no translation at all, and also when it has a
translated *name* but deliberately no state table (a course list whose
codes we can't map, for instance) -- callers treat both the same way:
leave the device's value untouched.
"""
entry = _ENTITY_CATALOG.get(platform, {}).get(translation_key)
return frozenset(entry.get('state', ())) if entry else frozenset()
+319 -36
View File
@@ -20,10 +20,13 @@ back for, power, mode, temperature and wind resources alike.
"""
from __future__ import annotations
import logging
from homeassistant.components.climate import (
ClimateEntity,
ClimateEntityFeature,
HVACMode,
PRESET_NONE,
)
from homeassistant.config_entries import ConfigEntry
from homeassistant.const import UnitOfTemperature
@@ -45,7 +48,10 @@ from .registry.capabilities.airconditioner import (
HREF_TEMPS_VS as TEMPS_VS_HREF,
HREF_WIND_STRENGTH as WIND_STRENGTH_HREF,
HREF_WIND_DIRECTION as WIND_DIRECTION_HREF,
HREF_WIND_OSCILLATION as WIND_OSCILLATION_HREF,
HREF_CONVENIENT as CONVENIENT_HREF,
HREF_AIRFLOW as AIRFLOW_HREF,
is_legacy_board,
)
from .registry.capabilities.common import normalize_temp_unit
@@ -53,6 +59,8 @@ from .const import DOMAIN
from .coordinator import LocalThingsCoordinator
from .entity import LocalThingsEntity, _is_included
_LOGGER = logging.getLogger(__name__)
_MODES_FIELD = 'x.com.samsung.da.modes'
_SUPPORTED_FIELD = 'x.com.samsung.da.supportedModes'
@@ -62,12 +70,39 @@ _SUPPORTED_FIELD = 'x.com.samsung.da.supportedModes'
_DEVICE_TO_HVAC: dict[str, HVACMode] = {
'Cool': HVACMode.COOL,
'Dry': HVACMode.DRY,
# Fan-only is spelled 'Wind' on some boards (e.g. TP1X_DA-AC-RAC-01001) and
# 'Fan' on others (e.g. TP1X_DA-AC-RAC-01011); both map to FAN_ONLY. The
# reverse write can't rely on this map alone (two codes, one HA value) --
# _device_code_for_hvac() resolves the code from the unit's own
# supportedModes, so this is only a fallback for a unit reporting no
# supportedModes at all. 'Fan' is listed first so the {v: k} reverse
# comprehension below has 'Wind' win that fallback (last-key-wins),
# preserving the original single-spelling behavior rather than silently
# flipping it when 'Fan' was added.
'Fan': HVACMode.FAN_ONLY,
'Wind': HVACMode.FAN_ONLY,
'Auto': HVACMode.HEAT_COOL,
# The device's 'Auto' is a single-setpoint "device decides" mode -> HA
# HVACMode.AUTO (renders "Auto"). Not HEAT_COOL: that renders "Heat/cool"
# and implies a two-setpoint heat+cool range these single-setpoint units
# (including cool-only models) don't have.
'Auto': HVACMode.AUTO,
'Heat': HVACMode.HEAT,
}
_HVAC_TO_DEVICE = {v: k for k, v in _DEVICE_TO_HVAC.items()}
# AI-driven auto-comfort mode (issue #93, A-CAWW-TP2-20-COMMON). Not a flat
# _DEVICE_TO_HVAC entry: 'AIComfort' isn't a distinct thermodynamic operation
# like Cool/Dry/Heat, it's an AI overlay on top of the device's own 'Auto'
# behavior -- confirmed by this unit reporting both 'Auto' and 'AIComfort' as
# separate, mutually-exclusive entries in /mode/vs/0's supportedModes. Modeled
# the idiomatic HA way instead: hvac_mode reports AUTO (same as the plain
# 'Auto' code maps to) and a dedicated 'ai_comfort' preset carries the
# distinction a bare hvac_mode can't. Not reachable via async_set_hvac_mode --
# entered/left only through the preset, since there's no dedicated HVACMode
# value for it to write back to.
_AI_COMFORT_MODE = 'AIComfort'
PRESET_AI_COMFORT = 'ai_comfort'
# Fan (wind strength): device codes "0".."4" -> HA standard fan constants where
# a clean match exists so they auto-localize; "turbo" is custom (translated).
_DEVICE_TO_FAN: dict[str, str] = {
@@ -84,19 +119,58 @@ _DEVICE_TO_SWING: dict[str, str] = {
'Fix': 'off',
'All': 'both',
'Up_And_Low': 'vertical',
'Left_And_Right': 'horizontal', # issue #75
}
_SWING_TO_DEVICE = {v: k for k, v in _DEVICE_TO_SWING.items()}
# Preset (convenient mode): Off/Sleep map onto HA standard presets; Quiet/Smart/
# Speed are custom (translated).
_DEVICE_TO_PRESET: dict[str, str] = {
'Off': 'none',
'Sleep': 'sleep',
'Quiet': 'quiet',
'Smart': 'smart',
'Speed': 'speed',
}
_PRESET_TO_DEVICE = {v: k for k, v in _DEVICE_TO_PRESET.items()}
# Swing fallback via /wind/oscillation/vs/0 (issue #126) -- boards without
# WIND_DIRECTION_HREF at all report two independent Swing|Fix toggles
# instead of one combined code. Same HA vocabulary as _DEVICE_TO_SWING
# above (off/vertical/horizontal/both), just read from/written to a pair
# of fields rather than a single one.
def _oscillation_swing(rep: dict) -> str | None:
vertical = rep.get('vertical')
horizontal = rep.get('horizontal')
if vertical is None and horizontal is None:
return None
v = vertical == 'Swing'
h = horizontal == 'Swing'
if v and h:
return 'both'
if v:
return 'vertical'
if h:
return 'horizontal'
return 'off'
def _wind_strength_label(code, rep: dict) -> str:
"""Human label for a /wind/strength/vs/0 code from the device's own
modesName array (parallel-indexed with supportedModes), lowercased for
HA -- used only for codes _DEVICE_TO_FAN doesn't already cover (issue
#155, TP1X_DA-AC-RAC-01001_0000: codes "0"/"31"-"35" instead of the
"0"-"4" scale _DEVICE_TO_FAN was built from, with modesName giving
"Auto"/"1"/"2"/"3"/"4"/"MAX"). No per-model numeric map -- mirrors
preset_mode's dynamic code->str resolution. Falls back to the raw code
lowercased when modesName is absent or misaligned."""
supported = rep.get('x.com.samsung.da.supportedModes') or []
names = rep.get('x.com.samsung.da.modesName') or []
if code in supported and len(names) == len(supported):
return str(names[supported.index(code)]).lower()
return str(code).lower()
# Preset (convenient mode): resolved dynamically from the device's own
# /mode/convenient/vs/0 supportedModes -- no per-model table. The device 'Off'
# code maps to HA's PRESET_NONE ("no preset active"); every other code is
# exposed as its lowercased self and labelled in translations
# (entity.climate.airconditioner.state_attributes.preset_mode.state.<code>),
# so any board's convenient modes surface without code changes, and an
# unlabelled code just renders as its raw value until a label is added.
# (Samsung's WindFree still-air cooling shows up here as the 'Nano'/
# 'NanoSleep' codes on cool-only global RAC boards -- that's just a
# translation label, not a hard-coded mode.)
def _preset_to_ha(code) -> str:
return PRESET_NONE if code == 'Off' else str(code).lower()
async def async_setup_entry(
@@ -164,32 +238,120 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
| ClimateEntityFeature.TURN_ON
| ClimateEntityFeature.TURN_OFF
)
# (href, raw device code) pairs already logged by _warn_unmapped --
# these properties are read on every coordinator refresh, so an
# un-deduped warning would spam the log for any device with a
# genuinely unrecognized code.
self._warned_unmapped: set[tuple[str, str]] = set()
# -- resource helpers ---------------------------------------------------
# Preset codes on legacy ARTIK051 boards, learned by driving the same unit
# through its cloud integration and reading the local token back each time:
# Nano=windFree, Quiet, Comfort, 2Step, Speed=Fast Turbo, Off=none.
_LEGACY_PRESET_CODES = ('Off', 'Nano', 'Quiet', 'Comfort', '2Step', 'Speed')
def _legacy_convenient(self) -> dict:
"""A /mode/convenient/vs/0-shaped rep built from the Comode_* token in
/mode/vs/0's options, for boards that have no convenient resource."""
options = (self.coordinator.resource(MODE_HREF) or {}).get(
'x.com.samsung.da.options') or []
for option in options:
if isinstance(option, str) and option.startswith('Comode_'):
return {_MODES_FIELD: [option.split('_', 1)[1]],
_SUPPORTED_FIELD: list(self._LEGACY_PRESET_CODES)}
return {}
def _legacy_airflow(self) -> dict:
"""The /airflow/vs/0 rep, but only when it is the fan/swing channel to
use -- i.e. this board has no /wind/strength/vs/0.
Delegates the board-generation test to is_legacy_board (the same
test capabilities/airconditioner.py's token entities are gated on)
instead of re-implementing it. Uses last_resources rather than a
two-key presence dict built from coordinator.resource()'s truthiness
-- resource() collapses "href absent" and "href present with an
empty {} rep" to the same falsy value, while is_legacy_board (and
discover()'s own binding) test key membership, not truthiness. A
presence dict built from truthiness alone would disagree with the
token entities on a board reporting a genuinely empty /airflow/vs/0,
silently reintroducing the drift this delegation exists to prevent.
"""
if not is_legacy_board(self.coordinator.last_resources):
return {}
return self.coordinator.resource(AIRFLOW_HREF) or {}
def _legacy_preset(self) -> bool:
"""Whether presets come from the Comode_* token rather than a resource.
Gated on the same board test as _legacy_airflow, not on the convenient
rep being empty alone: newer boards carry Comode tokens too, so a
momentarily empty /mode/convenient/vs/0 there must not silently switch
the preset read (and write) over to the token path.
"""
return (not self.coordinator.resource(CONVENIENT_HREF)
and bool(self._legacy_airflow()))
def _rep(self, href: str) -> dict:
return self.coordinator.resource(href) or {}
rep = self.coordinator.resource(href) or {}
if not rep and href == CONVENIENT_HREF and self._legacy_airflow():
return self._legacy_convenient()
return rep
def _is_on(self) -> bool:
rep = self._rep(POWER_HREF)
if 'value' in rep:
return bool(rep.get('value'))
vs = self._rep(POWER_VS_HREF)
return str(vs.get('x.com.samsung.da.power', '')).lower() == 'on'
# Prefer the vendor /power/vs/0 (present on every observed board and
# the resource writes target -- see airconditioner._climate_write).
# The OCF /power/0 is absent on many boards and a stale mirror on
# some, so reading it first showed pre-write state after a power
# toggle (issue #53: "can turn on but not off").
power = self._rep(POWER_VS_HREF).get('x.com.samsung.da.power')
if power is not None:
return str(power).lower() == 'on'
return bool(self._rep(POWER_HREF).get('value'))
def _supported(self, href: str) -> list[str]:
return list(self._rep(href).get(_SUPPORTED_FIELD) or [])
def _warn_unmapped(self, href: str, code: str) -> None:
"""Log once per (href, code) when a device-reported mode has no
entry in the relevant device<->HA map, so a real device gap surfaces
in the log instead of silently vanishing (issue #93)."""
key = (href, code)
if key in self._warned_unmapped:
return
self._warned_unmapped.add(key)
_LOGGER.warning(
"%s: device mode %r on %s has no HA mapping and was dropped; "
"please file an issue with your diagnostics dump",
self.entity_id, code, href,
)
def _read_mode(self, href: str, mapping: dict):
"""Current mode of a wind/convenient resource, mapped to its HA value."""
return mapping.get(_first(self._rep(href).get(_MODES_FIELD)))
raw = _first(self._rep(href).get(_MODES_FIELD))
if raw is not None and raw not in mapping:
self._warn_unmapped(href, raw)
return mapping.get(raw)
def _read_modes(self, href: str, mapping: dict) -> list[str]:
"""Supported modes of a resource, mapped to HA values (unknowns dropped)."""
return [mapping[c] for c in self._supported(href) if c in mapping]
supported = self._supported(href)
for c in supported:
if c not in mapping:
self._warn_unmapped(href, c)
return [mapping[c] for c in supported if c in mapping]
# -- temperature --------------------------------------------------------
def _ocf_temp_authoritative(self) -> bool:
"""True when the OCF /temperature/{current,desired}/0 pair is the
authoritative temperature channel -- signalled by
/temperature/current/0 being present. Those boards honour reads/
writes on /temperature/desired/0 and ignore the vendor
/temperatures/vs/0; boards without the pair (only a desired stub, or
nothing) are the reverse. Confirmed on live units of both kinds."""
return bool(self._rep(TEMP_CURRENT_HREF))
def _temps_vs(self) -> dict:
"""Vendor `/temperatures/vs/0` items[0] (empty {} when absent)."""
return _temps_vs_item(self._rep(TEMPS_VS_HREF))
@@ -212,10 +374,14 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
@property
def target_temperature(self):
v = _num(self._rep(TEMP_DESIRED_HREF).get('temperature'))
if v is None:
v = _num(self._temps_vs().get('x.com.samsung.da.desired'))
return v
# Read from the same channel writes go to (see async_set_temperature):
# OCF /temperature/desired/0 on boards with the full OCF pair, vendor
# /temperatures/vs/0 otherwise -- with the other as fallback.
ocf = _num(self._rep(TEMP_DESIRED_HREF).get('temperature'))
vs = _num(self._temps_vs().get('x.com.samsung.da.desired'))
if self._ocf_temp_authoritative():
return ocf if ocf is not None else vs
return vs if vs is not None else ocf
def _range(self) -> list | None:
r = self._rep(TEMP_DESIRED_HREF).get('range')
@@ -250,14 +416,23 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
if not self._is_on():
return HVACMode.OFF
device = _first(self._rep(MODE_HREF).get(_MODES_FIELD))
if device == _AI_COMFORT_MODE:
return HVACMode.AUTO
if device is not None and device not in _DEVICE_TO_HVAC:
self._warn_unmapped(MODE_HREF, device)
return _DEVICE_TO_HVAC.get(device, HVACMode.AUTO)
@property
def hvac_modes(self) -> list[HVACMode]:
modes = [HVACMode.OFF]
for m in self._supported(MODE_HREF):
if m == _AI_COMFORT_MODE:
continue
mapped = _DEVICE_TO_HVAC.get(m)
if mapped is not None and mapped not in modes:
if mapped is None:
self._warn_unmapped(MODE_HREF, m)
continue
if mapped not in modes:
modes.append(mapped)
return modes
@@ -265,40 +440,103 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
@property
def fan_mode(self):
return self._read_mode(WIND_STRENGTH_HREF, _DEVICE_TO_FAN)
airflow = self._legacy_airflow()
if airflow:
return _DEVICE_TO_FAN.get(str(airflow.get('x.com.samsung.da.speedLevel')))
rep = self._rep(WIND_STRENGTH_HREF)
code = _first(rep.get(_MODES_FIELD))
if code is None:
return None
return _DEVICE_TO_FAN.get(code) or _wind_strength_label(code, rep)
@property
def fan_modes(self) -> list[str]:
return self._read_modes(WIND_STRENGTH_HREF, _DEVICE_TO_FAN)
if self._legacy_airflow():
# This resource carries no supportedModes, so the full scale is offered.
return list(_DEVICE_TO_FAN.values())
rep = self._rep(WIND_STRENGTH_HREF)
modes = []
for code in self._supported(WIND_STRENGTH_HREF):
mode = _DEVICE_TO_FAN.get(code) or _wind_strength_label(code, rep)
if mode not in modes:
modes.append(mode)
return modes
def _swing_via_direction(self) -> bool:
"""True when WIND_DIRECTION_HREF is the swing channel to use --
signalled by its presence. Boards without it (issue #126) report
the 2-axis oscillation resource instead; see _oscillation_swing."""
return bool(self._rep(WIND_DIRECTION_HREF))
@property
def swing_mode(self):
return self._read_mode(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
airflow = self._legacy_airflow()
if airflow:
return _DEVICE_TO_SWING.get(airflow.get('x.com.samsung.da.direction'))
if self._swing_via_direction():
return self._read_mode(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
return _oscillation_swing(self._rep(WIND_OSCILLATION_HREF))
@property
def swing_modes(self) -> list[str]:
return self._read_modes(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
if self._legacy_airflow():
return list(_SWING_TO_DEVICE.keys())
if self._swing_via_direction():
return self._read_modes(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
if self._rep(WIND_OSCILLATION_HREF):
return list(_SWING_TO_DEVICE.keys())
return []
@property
def preset_mode(self):
return self._read_mode(CONVENIENT_HREF, _DEVICE_TO_PRESET)
if _first(self._rep(MODE_HREF).get(_MODES_FIELD)) == _AI_COMFORT_MODE:
return PRESET_AI_COMFORT
code = _first(self._rep(CONVENIENT_HREF).get(_MODES_FIELD))
return _preset_to_ha(code) if code is not None else None
@property
def preset_modes(self) -> list[str]:
return self._read_modes(CONVENIENT_HREF, _DEVICE_TO_PRESET)
modes = [_preset_to_ha(c) for c in self._supported(CONVENIENT_HREF)]
if _AI_COMFORT_MODE in self._supported(MODE_HREF):
modes.append(PRESET_AI_COMFORT)
return modes
# -- writes -------------------------------------------------------------
def _device_code_for_hvac(self, hvac_mode: HVACMode):
"""Device mode code for an HA hvac_mode, chosen from this unit's own
supportedModes -- fan-only is 'Wind' on some boards and 'Fan' on
others, so the reverse map alone can't pick the code this unit
accepts."""
for code in self._supported(MODE_HREF):
if _DEVICE_TO_HVAC.get(code) == hvac_mode:
return code
return _HVAC_TO_DEVICE.get(hvac_mode)
async def async_set_temperature(self, **kwargs) -> None:
# HA's set_temperature service forwards an optional hvac_mode here; honour
# it (set the mode first -- that also powers the unit on when it was off),
# matching the climate contract other integrations follow. Without this a
# set_temperature call carrying hvac_mode (e.g. a dashboard "turn on to
# Auto 24" button) set the setpoint but never changed mode or powered on.
hvac_mode = kwargs.get('hvac_mode')
if hvac_mode is not None:
await self.async_set_hvac_mode(hvac_mode)
if hvac_mode == HVACMode.OFF:
return
temp = kwargs.get('temperature')
if temp is not None:
await self.coordinator.async_send_command(self._bound, ('temperature', temp))
if temp is None:
return
# OCF-pair boards write /temperature/desired/0; vendor boards write
# /temperatures/vs/0 (see airconditioner._climate_write).
kind = 'temperature_ocf' if self._ocf_temp_authoritative() else 'temperature'
await self.coordinator.async_send_command(self._bound, (kind, temp))
async def async_set_hvac_mode(self, hvac_mode: HVACMode) -> None:
if hvac_mode == HVACMode.OFF:
await self.coordinator.async_send_command(self._bound, ('power', False))
return
device = _HVAC_TO_DEVICE.get(hvac_mode)
device = self._device_code_for_hvac(hvac_mode)
if device is None:
return
if not self._is_on():
@@ -318,10 +556,55 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
await self.coordinator.async_send_command(self._bound, (kind, device))
async def async_set_fan_mode(self, fan_mode: str) -> None:
await self._set_mapped('fan', _FAN_TO_DEVICE, fan_mode)
if self._legacy_airflow():
level = _FAN_TO_DEVICE.get(fan_mode)
if level is not None:
await self.coordinator.async_send_command(
self._bound, ('fan_legacy', level))
return
supported = self._supported(WIND_STRENGTH_HREF)
device = _FAN_TO_DEVICE.get(fan_mode)
# A static hit is only trustworthy if this unit's own supportedModes
# actually includes that code -- a board can use non-standard codes
# (issue #155's "31"-"35") while still spelling a standard label
# ("Low"/"High") in modesName, in which case _FAN_TO_DEVICE.get would
# return a plausible-looking code ('1'/'3') the device never
# advertised at all. Fall through to the live scan whenever the
# static guess isn't actually one of this unit's own codes.
if device is None or (supported and device not in supported):
rep = self._rep(WIND_STRENGTH_HREF)
for code in supported:
if _wind_strength_label(code, rep) == fan_mode:
device = code
break
if device is not None:
await self.coordinator.async_send_command(self._bound, ('fan', device))
async def async_set_swing_mode(self, swing_mode: str) -> None:
await self._set_mapped('swing', _SWING_TO_DEVICE, swing_mode)
if self._legacy_airflow():
code = _SWING_TO_DEVICE.get(swing_mode)
if code is not None:
await self.coordinator.async_send_command(
self._bound, ('swing_legacy', code))
return
if self._swing_via_direction():
await self._set_mapped('swing', _SWING_TO_DEVICE, swing_mode)
return
if self._rep(WIND_OSCILLATION_HREF):
await self.coordinator.async_send_command(
self._bound, ('oscillation', swing_mode))
async def async_set_preset_mode(self, preset_mode: str) -> None:
await self._set_mapped('preset', _PRESET_TO_DEVICE, preset_mode)
if preset_mode == PRESET_AI_COMFORT:
# Writes the primary mode resource, not the convenient one --
# 'AIComfort' lives in /mode/vs/0 alongside Cool/Dry/Auto, not in
# /mode/convenient/vs/0 with Quiet/Smart/Speed/Sleep.
await self.coordinator.async_send_command(self._bound, ('mode', _AI_COMFORT_MODE))
return
# Reverse-resolve against the unit's own supportedModes (codes aren't
# a fixed transform of the HA value -- e.g. 'NanoSleep' -> 'nanosleep').
for code in self._supported(CONVENIENT_HREF):
if _preset_to_ha(code) == preset_mode:
kind = 'preset_legacy' if self._legacy_preset() else 'preset'
await self.coordinator.async_send_command(self._bound, (kind, code))
return
+26 -28
View File
@@ -197,14 +197,24 @@ def _find_live_ports(host: str, ports: list[int], timeout: float) -> list[int]:
return _order_candidates(live)
def _is_placeholder_serial(serial: str) -> bool:
"""True for a non-empty serialNum that isn't actually a real identity.
The ARTIK051_DONGLE_REF firmware family reports the literal string
'Nothing(SVC)' for every unit -- non-empty, so the plain `if not
serial` check here (and the equivalent one in coordinator.py's
`_run_discovery`) doesn't catch it, and two such units get the same
config-entry unique_id / entity unique_ids and collide (issue #83).
"""
return serial.strip().lower().startswith('nothing')
def _probe_and_validate(host: str, ca_cert_pem: str, ca_key_pem: str) -> dict:
"""Fetch UUID, mint leaf cert, probe each port. Returns config entry data dict."""
import cbor2
from smartthings_local.protocol.dtls_session import DtlsCoapSession
from .registry.batch import parse_device0_batch
from .registry.by_type import (
for_device, for_device_by_model, for_device_by_resources,
)
from .registry.by_type import resolve as resolve_registry
_LOGGER.debug("Fetching Samsung cloud UUID from %s", _SAMSUNG_CLOUD_HOST)
try:
@@ -261,27 +271,14 @@ def _probe_and_validate(host: str, ca_cert_pem: str, ca_key_pem: str) -> dict:
.get('/information/vs/0', {})
.get('x.com.samsung.da.serialNum', '')
)
if not serial:
if not serial or _is_placeholder_serial(serial):
serial = f"{host}:{port}"
one_ui_version = (
resources
.get('/otninformation/vs/0', {})
.get('swVersionInfo', {})
.get('oneUiVersion', '')
)
info_resource = resources.get('/information/vs/0', {})
recognized_registry = (
for_device(one_ui_version) if one_ui_version else None
) or for_device_by_model(
info_resource.get('x.com.samsung.da.modelNum', ''),
info_resource.get('x.com.samsung.da.description', ''),
) or for_device_by_resources(resources)
recognized_registry = resolve_registry(resources)
return {
"port": port,
"serial": serial,
"leaf_cert_pem": fullchain_pem,
"leaf_key_pem": leaf_key_pem,
"one_ui_version": one_ui_version,
"device_type_recognized": recognized_registry is not None,
}
except CannotConnect:
@@ -368,35 +365,36 @@ class LocalThingsConfigFlow(config_entries.ConfigFlow, domain=DOMAIN):
if has_creds:
schema = vol.Schema({vol.Required(CONF_HOST): _TEXT})
reuse_note = "CA credentials will be reused from the existing device."
step_id = "user_reuse"
else:
schema = vol.Schema({
vol.Required(CONF_HOST): _TEXT,
vol.Required(CONF_CA_CERT_PEM): _MULTILINE,
vol.Required(CONF_CA_KEY_PEM): _MULTILINE,
})
reuse_note = ""
step_id = "user"
return self.async_show_form(
step_id="user",
step_id=step_id,
data_schema=schema,
errors=errors,
description_placeholders={"reuse_note": reuse_note},
)
async def async_step_user_reuse(
self, user_input: dict[str, Any] | None = None
) -> FlowResult:
"""Handle the localized host-only form for additional appliances."""
return await self.async_step_user(user_input)
async def async_step_confirm_unknown_type(
self, user_input: dict[str, Any] | None = None
) -> FlowResult:
"""Shown only when the probe already knows the device type is unrecognized."""
if user_input is not None:
return self._create_entry(self._pending_info)
return self.async_show_form(
step_id="confirm_unknown_type",
data_schema=vol.Schema({}),
description_placeholders={
"one_ui_version": self._pending_info["one_ui_version"] or "(none reported)",
},
)
@@ -487,7 +485,7 @@ class LocalThingsOptionsFlow(config_entries.OptionsFlow):
"href": href,
"current_value": (
json.dumps(current, indent=2, ensure_ascii=False)
if current else "(no cached value)"
if current else "{}"
),
},
)
@@ -531,7 +529,7 @@ class LocalThingsOptionsFlow(config_entries.OptionsFlow):
"code": f"{code >> 5}.{code & 0x1f:02d} ({code:#04x})",
"new_value": (
json.dumps(new_rep, indent=2, ensure_ascii=False)
if new_rep else "(no value returned)"
if new_rep else "{}"
),
},
)
+7
View File
@@ -42,6 +42,13 @@ LIVENESS_PROBE_TIMEOUT_S = 1.5
# without stalling setup; it matches the per-resource read timeout elsewhere.
PROBE_GET_TIMEOUT_S = 10.0
# Base for the local (client-side) DTLS source port, distinct from the
# destination probe ports above. See coordinator._local_source_port for why a
# fixed per-device source port matters and how the per-device offset is
# derived. Base mirrors the upstream smartthings-local reference bridge.
# Requires smartthings-local >= 0.1.1.
DTLS_LOCAL_PORT_BASE = 49700
SUMMARY_INTERVAL_S = 30.0
DEVICE_SUPPORT_ISSUE_URL = (
+168 -53
View File
@@ -2,9 +2,11 @@
from __future__ import annotations
import asyncio
import ipaddress
import logging
import threading
import time
import zlib
from datetime import timedelta
from typing import Any
@@ -21,8 +23,13 @@ from smartthings_local.protocol.dtls_session import DtlsCoapSession
from smartthings_local.ocf.state_cache import StateCache
from .registry.batch import parse_device0_batch
from .registry.by_type import for_device, for_device_by_model, for_device_by_resources
from .registry.capabilities.common import merge_options_field, remote_control_enabled
from .registry.by_type import resolve as resolve_registry
from .registry.capabilities.common import (
merge_items_field,
merge_options_field,
remote_control_enabled,
remote_control_required_for_write,
)
from .registry.discovery import discover, BoundEntity
from .registry import CAPABILITIES
from .registry.adapter import flatten
@@ -32,19 +39,13 @@ from .observe import ObserveManager, MODE_OBSERVE, MODE_POLL, GRACE_PERIOD_S
from .const import (
DOMAIN, CONF_HOST, CONF_PORT, CONF_LEAF_CERT_PEM, CONF_LEAF_KEY_PEM,
CONF_BYPASS_REMOTE_CONTROL, DEVICE_SUPPORT_ISSUE_URL, SUMMARY_INTERVAL_S,
DTLS_LOCAL_PORT_BASE,
)
_LOGGER = logging.getLogger(__name__)
_SEED_PATH = ['device', '0']
_REMOTE_CONTROL_DISABLED_MESSAGE = (
"Remote control is turned off on this device. Check your appliance's "
"manual for how to enable remote control before Home Assistant can "
"control it."
)
class _NoOpDescriptor:
"""StateCache requires a descriptor with an on_observation hook. This
integration doesn't use per-capability observation hooks, so this is a
@@ -56,6 +57,45 @@ class _NoOpDescriptor:
_RECOVERY_RETRY_S = 600.0 # re-attempt observe mode this often while polling
def _local_source_port(host: str) -> int:
"""Deterministic UDP source port for this device's DTLS socket.
Binding the same source port on every (re)connect keeps the client on one
5-tuple, so the appliance evicts an orphaned session left by a previous run
(unclean shutdown -> no DTLS close_notify) at handshake time per RFC 6347
§4.2.8, instead of holding it for 5-15 min while the new session's reads
hang. See DTLS_LOCAL_PORT_BASE in const.py. Requires smartthings-local
>= 0.1.1 (the version that added DtlsCoapSession(local_port=...)).
The port must be stable across restarts and unique per device on this HA
host: the library's socket is unconnected (recvfrom), so two devices
sharing a source port would mis-demux each other's datagrams. For the usual
dotted-IPv4 host we use the last octet as the offset (unique on a /24);
anything else folds a stable CRC32 into the same 256-wide window.
"""
try:
offset = int(ipaddress.IPv4Address(host)) & 0xFF
except (ipaddress.AddressValueError, ValueError):
offset = zlib.crc32(host.encode()) & 0xFF
return DTLS_LOCAL_PORT_BASE + offset
def _is_placeholder_serial(serial: str) -> bool:
"""True for a non-empty serialNum that isn't actually a real identity.
The ARTIK051_DONGLE_REF firmware family reports the literal string
'Nothing(SVC)' for every unit -- non-empty, so the plain `if not
serial` check below doesn't catch it, and `device_serial` feeds both
the HA device-registry identifier and every entity's unique_id
(entity.py), so two such units on the same install silently collide
and the second one's entities get dropped (issue #83). Mirrors the
identical helper in config_flow.py's `_probe_and_validate` -- kept
separate rather than imported to avoid pulling the config-flow module
into the runtime coordinator's import graph for a two-line check.
"""
return serial.strip().lower().startswith('nothing')
class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
"""Manages one Samsung appliance: session, discovery, polling."""
@@ -71,6 +111,24 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
_OBSERVE_GRACE_PERIOD_S: float = GRACE_PERIOD_S
_RECONNECT_PAUSE_S: float = 5.0
# A single reconnect is normal appliance-side behavior (see the
# README's "Known device behavior" section) -- Samsung's firmware
# drops the DTLS session briefly every now and then, and the
# coordinator recovering from that on its own isn't something a user
# needs to see at WARNING. Only escalate once reconnects pile up
# within a trailing window (issue #119).
#
# The window can't be a literal 60s: consecutive reconnect attempts are
# never closer together than one summary poll interval (SUMMARY_INTERVAL_S,
# 30s) plus _RECONNECT_PAUSE_S, so at most ~2 can ever land inside a 60s
# window regardless of how unhealthy the connection is -- a threshold of
# 5 there could never fire, silently downgrading every reconnect
# (including a persistently broken one) to INFO forever. 300s/3 instead:
# reachable under normal polling, and 3 reconnects inside 5 minutes is
# still a reasonable proxy for the README's "actually broken" case.
_RECONNECT_WARN_WINDOW_S: float = 300.0
_RECONNECT_WARN_THRESHOLD: int = 3
# A block-level ACK timeout on the summary GET doesn't prove the
# session is dead (see _poll_once) — require this many in a row
# before treating it as one. A single slow transfer on an otherwise
@@ -122,6 +180,7 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
self.one_ui_version: str = ''
self._consecutive_poll_timeouts = 0
self._unbound_hrefs: list[str] = []
self._reconnect_times: list[float] = []
# ------------------------------------------------------------------
# Session management (all blocking — must run in executor)
@@ -149,7 +208,8 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
key_pem = self._entry.data[CONF_LEAF_KEY_PEM]
sess = DtlsCoapSession(host, port, cert_pem=cert_pem, key_pem=key_pem,
on_notification=self._observe.on_notification)
on_notification=self._observe.on_notification,
local_port=_local_source_port(host))
sess.connect()
sess.start_reader()
self._session = sess
@@ -292,40 +352,51 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
# ------------------------------------------------------------------
def _run_discovery(self, resources: dict[str, dict]) -> None:
one_ui = (resources.get('/otninformation/vs/0', {})
.get('swVersionInfo', {})
.get('oneUiVersion', ''))
self.one_ui_version = one_ui
# Reported for diagnostics only -- it names the firmware generation
# ('7.0 Air conditioner' is Tizen Lite), which is useful when triaging
# an issue. It does not route: only a minority of hardware reports it
# at all, and every device that does is already typed by its modelNum.
self.one_ui_version = (resources.get('/otninformation/vs/0', {})
.get('swVersionInfo', {})
.get('oneUiVersion', ''))
info = resources.get('/information/vs/0', {})
reg = for_device(one_ui) if one_ui else None
if reg is None:
reg = for_device_by_model(
info.get('x.com.samsung.da.modelNum', ''),
info.get('x.com.samsung.da.description', ''),
)
if reg is None:
reg = for_device_by_resources(resources)
reg = resolve_registry(resources)
unbound: list[str] = []
hot, warm = set(), set()
def _tier_log(href: str, tier: str) -> None:
if tier == 'hot':
hot.add(href)
elif tier == 'warm':
warm.add(href)
model_num = info.get('x.com.samsung.da.modelNum', '')
description = info.get('x.com.samsung.da.description', '')
if reg is not None:
self._log.debug("device type: %s (oneUiVersion=%r)", reg.name, one_ui)
self._log.debug("device type: %s (modelNum=%r)", reg.name, model_num)
bound = discover(resources, reg.capabilities, reg.pattern_capabilities,
log=unbound.append)
log=unbound.append, tier_log=_tier_log)
self.device_type_name = reg.name
else:
self._log.warning("unknown device type oneUiVersion=%r; using common caps", one_ui)
bound = discover(resources, CAPABILITIES, log=unbound.append)
# Both fields: detection reads each of them (board token, then
# consumer-model code), and this line is what a user pastes into
# an issue -- modelNum alone doesn't identify a washer or dryer.
self._log.warning(
"unknown device type modelNum=%r description=%r; using common caps",
model_num, description,
)
bound = discover(resources, CAPABILITIES, log=unbound.append, tier_log=_tier_log)
self.device_type_name = None
self.bound = bound
self._unbound_hrefs = unbound
serial = info.get('x.com.samsung.da.serialNum', '')
if not serial:
if not serial or _is_placeholder_serial(serial):
serial = self._entry.data[CONF_HOST]
self.device_serial = serial
ident = self._identity
device_type = reg.name.replace('_', ' ').title() if reg else 'Appliance'
model_num = info.get('x.com.samsung.da.modelNum', '')
model = model_num.split('|', 1)[0] if model_num else (ident.model if ident else '')
name = f"Samsung {device_type} ({model})" if model else f"Samsung {device_type}"
mfr = (ident.manufacturer if ident else '') or 'Samsung'
@@ -338,13 +409,6 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
)
self._update_coverage_gap_issue(reg is None, unbound, name)
hot, warm = set(), set()
for be in bound:
tier = be.capability.poll_tier
if tier == 'hot':
hot.add(be.href)
elif tier == 'warm':
warm.add(be.href)
self._hot_hrefs = sorted(hot)
self._warm_hrefs = sorted(warm)
@@ -430,6 +494,17 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
self._consecutive_poll_timeouts += 1
return self._consecutive_poll_timeouts < self._POLL_TIMEOUT_LIMIT
def _reconnect_is_frequent(self) -> bool:
"""True once this cycle's reconnect is the Nth within the trailing
warn window -- see _RECONNECT_WARN_WINDOW_S/_RECONNECT_WARN_THRESHOLD."""
now = time.monotonic()
self._reconnect_times = [
t for t in self._reconnect_times
if now - t < self._RECONNECT_WARN_WINDOW_S
]
self._reconnect_times.append(now)
return len(self._reconnect_times) >= self._RECONNECT_WARN_THRESHOLD
# ------------------------------------------------------------------
# DataUpdateCoordinator hook
# ------------------------------------------------------------------
@@ -456,7 +531,13 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
self._consecutive_poll_timeouts = 0
# One reconnect attempt — pause briefly so the device can
# clean up its DTLS session state before we knock again.
self._log.warning("poll failed, reconnecting: %s", e)
# A lone reconnect is routine (see the README's "Known
# device behavior" section); only warn once they're piling
# up within the trailing window.
if self._reconnect_is_frequent():
self._log.warning("poll failed, reconnecting: %s", e)
else:
self._log.info("poll failed, reconnecting: %s", e)
await self.hass.async_add_executor_job(self._close_session)
await asyncio.sleep(self._RECONNECT_PAUSE_S)
try:
@@ -538,7 +619,10 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
opted this device out of it via CONF_BYPASS_REMOTE_CONTROL (issue
#54: some devices accept certain writes, e.g. a washer's default
dosing levels, even while reporting remote control off, so the
block's assumption doesn't hold for every model)."""
block's assumption doesn't hold for every model), or the laundry
firmware flag isModelSettingWithoutSC declares settings writable
without Smart Control (cycle start/pause/stop on /operational/state
still require it)."""
desc = bound_entity.desc
write_fn = getattr(desc, 'write_fn', None)
if write_fn is None:
@@ -547,14 +631,27 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
rep = self._cache.get(href or '') or {}
resources = self._cache.snapshot()
bypass_remote_control = self._entry.options.get(CONF_BYPASS_REMOTE_CONTROL, False)
if not bypass_remote_control and not remote_control_enabled(resources):
raise ServiceValidationError(_REMOTE_CONTROL_DISABLED_MESSAGE)
if (
not bypass_remote_control
and remote_control_required_for_write(resources, href or '')
and not remote_control_enabled(resources)
):
raise ServiceValidationError(
translation_domain=DOMAIN,
translation_key="remote_control_disabled",
)
validate_fn = getattr(desc, 'validate_fn', None)
if validate_fn is not None:
error = validate_fn(payload, rep, resources)
if error:
raise ServiceValidationError(error)
result = write_fn(payload, rep, href)
raise ServiceValidationError(
translation_domain=DOMAIN,
translation_key=error,
)
try:
result = write_fn(payload, rep, href, resources)
except TypeError:
result = write_fn(payload, rep, href)
if result is None:
self._log.warning("write_fn rejected payload %r for %s", payload, href)
return
@@ -612,23 +709,35 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
# introduced its own races around overlapping writes to the same
# href. Simpler and safer to just hold the guard for the full,
# generously-sized window and let it expire on its own.
# write_fn bodies that touch x.com.samsung.da.options carry only the
# changed token(s) now (issue #54: confirmed sufficient on the wire --
# the device merges by prefix itself), not the whole packed array.
# observe.apply()'s field-level {**cached, **rep} merge doesn't know
# that -- handed the bare token list, it would replace the cached
# field outright and wipe every sibling option for the rest of the
# settle window. Pre-merge it here the same way the device does, so
# the optimistic cache entry stays complete; the minimal `body` below
# is still exactly what goes out over the wire.
# write_fn bodies that touch x.com.samsung.da.options or
# x.com.samsung.da.items carry only the changed token(s)/item now
# (issue #54 for options; the AC vendor temperature write for items --
# confirmed sufficient on the wire, the device merges the rest itself),
# not the whole packed array. observe.apply()'s field-level
# {**cached, **rep} merge doesn't know that -- handed the bare
# partial value, it would replace the cached field outright and wipe
# every sibling option/item for the rest of the settle window.
# Pre-merge it here the same way the device does, so the optimistic
# cache entry stays complete; the minimal `body` below is still
# exactly what goes out over the wire.
optimistic_body = body
new_options = body.get('x.com.samsung.da.options')
if isinstance(new_options, list):
cached_options = (self._cache.get(write_href) or {}).get('x.com.samsung.da.options')
optimistic_body = {
**body,
**optimistic_body,
'x.com.samsung.da.options': merge_options_field(cached_options, new_options),
}
# Same fact, items[] shape (e.g. airconditioner._climate_write's vendor
# temperature write, which now carries only {id, desired} -- see that
# module for the write-side half of this).
new_items = body.get('x.com.samsung.da.items')
if isinstance(new_items, list):
cached_items = (self._cache.get(write_href) or {}).get('x.com.samsung.da.items')
optimistic_body = {
**optimistic_body,
'x.com.samsung.da.items': merge_items_field(cached_items, new_items),
}
self._observe.apply(write_href, optimistic_body, source='optimistic')
self._observe.mark_write_pending(
write_href, settle_s=self._POST_TIMEOUT_S + self._POLL_TIMEOUT_S
@@ -689,10 +798,16 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
help users pin down device-specific write behavior without a new
release."""
if not isinstance(body, dict) or not body:
raise ServiceValidationError("Debug write payload must be a non-empty object.")
raise ServiceValidationError(
translation_domain=DOMAIN,
translation_key="debug_payload_empty",
)
path_segs = [s for s in href.strip('/').split('/') if s]
if not path_segs:
raise ServiceValidationError("A resource href is required.")
raise ServiceValidationError(
translation_domain=DOMAIN,
translation_key="resource_href_required",
)
norm_href = '/' + '/'.join(path_segs)
async with self._session_lock:
code, new_rep = await self.hass.async_add_executor_job(
@@ -31,9 +31,19 @@ async def async_get_config_entry_diagnostics(
# detector when called inline here. Offload it to the executor.
stl_version = await hass.async_add_executor_job(pkg_version, "smartthings-local")
# /oic/p and /oic/d sit outside the /device/0 batch captured below, so
# they'd otherwise never reach an issue report. /oic/d's `rt` is OCF's
# standard device-type declaration -- see registry/identity.py.
identity = coordinator._identity
return {
"device_type": coordinator.device_type_name or "unknown",
"one_ui_version": coordinator.one_ui_version,
"identity": {
"manufacturer": identity.manufacturer,
"model": identity.model,
"device_types": list(identity.device_types),
"resources": redact_resources(identity.raw),
} if identity is not None else None,
"unbound_hrefs": sorted(coordinator._unbound_hrefs),
"resources": redact_resources(coordinator.last_resources),
"integration_version": integration.version,
+55 -20
View File
@@ -8,6 +8,7 @@ from homeassistant.helpers.device_registry import DeviceInfo
from homeassistant.const import EntityCategory
from .registry.adapter import _key
from .registry.batch import is_stub_rep
from .registry.discovery import BoundEntity, _snake_to_title
from .const import DOMAIN
@@ -21,9 +22,17 @@ def _is_included(bound: BoundEntity, coordinator: 'LocalThingsCoordinator') -> b
require that field to be present in the resource rep so that optional
fields on shared resources don't create phantom entities.
An empty rep ({}) means /device/0 returned a stub for this resource —
the resource exists on the device but data hasn't been fetched yet.
In that case we include the entity so it can be populated by sub-polls.
A stub rep (is_stub_rep — /device/0's "resource exists, no data fetched
yet" marker) is included anyway so it can be populated by sub-polls. A
genuinely empty {} rep is included too by this default gate -- whether
empty means "not populated yet" or "permanently unsupported" needs
per-field domain knowledge this generic gate doesn't have: /alarms/vs/0's
{} is fridge.py's documented *normal* no-alarm state (see
_active_alarm_codes), not an absence signal, and it's far from the only
resource like that. Only a capability whose author has actually verified
a field is genuinely never populated on unsupported hardware opts into
stricter gating with its own is_stub_rep-based exists_fn (see
common.ENERGY_METER, issue #127) -- this default stays permissive.
"""
rep = coordinator.last_resources.get(bound.href)
if rep is None:
@@ -31,22 +40,39 @@ def _is_included(bound: BoundEntity, coordinator: 'LocalThingsCoordinator') -> b
if bound.desc.exists_fn is not None:
return bound.desc.exists_fn(rep, coordinator.last_resources)
if bound.desc.field:
if not rep: # stub — resource known to exist, data not yet fetched
if not rep or is_stub_rep(rep):
return True
return bound.desc.field in rep
return True # rep_fn or no-field entities (ButtonDesc) are always included
def _derive_name(state_key: str) -> str:
"""Turn a snake_case state key into a title-cased display name.
"""Turn a snake_case state key into a title-cased label.
Strips a trailing instance number of 0 (singleton), promotes any other
instance number with a space: "door_cooler_open1" → "Door Cooler Open 1".
Entity names themselves come from the translation catalog; this only
builds the {instance_name} placeholder those translations interpolate,
for a device that named its own compartments/ice makers.
"""
name = re.sub(r'(\d+)$', lambda m: f' {m.group()}' if int(m.group()) > 0 else '', state_key)
return _snake_to_title(name).strip()
def _instance_display_name(bound: BoundEntity, state_key: str) -> str:
"""Return the stable vendor/href instance label used in a name placeholder."""
if bound.instance_name:
return bound.instance_name
source = bound.key_override or state_key
suffix = f"_{bound.desc.key}"
if source.endswith(suffix):
source = source[:-len(suffix)]
elif bound.instance and source.endswith(bound.instance):
source = source[:-len(bound.instance)] + bound.instance.replace("_", " ")
return _derive_name(source)
class LocalThingsEntity(CoordinatorEntity[LocalThingsCoordinator]):
"""Base class for all Local Things entities."""
@@ -57,15 +83,21 @@ class LocalThingsEntity(CoordinatorEntity[LocalThingsCoordinator]):
self._bound = bound
self._state_key = _key(bound)
self._attr_unique_id = f"{DOMAIN}_{coordinator.device_serial}_{self._state_key}"
if bound.desc.name is not None:
self._attr_name = bound.desc.name
elif bound.instance_name:
# A device-given instance name (e.g. an ice maker's "Cubed
# Ice") takes the place of the href-derived instance label,
# keeping the same entity-specific suffix (issue #27).
self._attr_name = f"{bound.instance_name} {_derive_name(bound.desc.key)}".strip()
else:
self._attr_name = _derive_name(self._state_key)
if bound.desc.translation_placeholders is not None:
self._attr_translation_placeholders = dict(
bound.desc.translation_placeholders
)
elif bound.desc.use_instance_name:
self._attr_translation_placeholders = {
"instance_name": _instance_display_name(bound, self._state_key)
}
# _attr_name is deliberately left unset: Home Assistant gives an
# explicitly-set name precedence over the translation catalog, so
# setting it here would make every entity untranslatable. Every
# descriptor resolves to a catalog entry (see translation_key below);
# a platform that wants the bare device name instead sets
# _attr_name = None itself, as fan.py does for the hood's main entity.
self._attr_icon = bound.desc.icon
raw_cat = bound.desc.entity_category
self._attr_entity_category = EntityCategory(raw_cat) if raw_cat else None
@@ -73,11 +105,12 @@ class LocalThingsEntity(CoordinatorEntity[LocalThingsCoordinator]):
@property
def translation_key(self) -> str | None:
"""Override Entity.translation_key (a property upstream, not a
plain attribute) so a callable descriptor -- e.g.
laundry.cycle_select's table-id-gated resolver -- is re-evaluated
against live coordinator data on every access, not resolved once
at construction time.
"""The descriptor's catalog key, defaulting to its own `key`.
Overrides Entity.translation_key (a property upstream, not a plain
attribute) so a callable descriptor -- e.g. laundry.cycle_select's
table-id-gated resolver -- is re-evaluated against live coordinator
data on every access, not resolved once at construction time.
Discovery runs on the first /device/0 poll, which the entity
registry already documents can hand a sibling resource an empty
@@ -88,7 +121,9 @@ class LocalThingsEntity(CoordinatorEntity[LocalThingsCoordinator]):
value arrives on a later poll.
"""
tk = self._bound.desc.translation_key
return tk(self.coordinator.last_resources) if callable(tk) else tk
if callable(tk):
return tk(self.coordinator.last_resources)
return tk if tk is not None else self._bound.desc.key
@property
def device_info(self) -> DeviceInfo:
+279 -12
View File
@@ -1,7 +1,23 @@
"""Fan platform for Samsung range hoods."""
"""Fan platform for Samsung range hoods and air purifiers.
Four FanDesc-bound hrefs exist, dispatched by href in async_setup_entry
below since each needs different HA fan semantics: the range hood's fan
speed and the older ARTIK051_TVTL air-purifier family's Auto/Sleep/Low/
Medium/High (issue #56) are both an ordered set of numeric levels
(SET_SPEED) -- the latter confirmed monotonic in capabilities/
air_purifier.py's module docstring, with no named-mode list to preserve
since this board never self-reports one. The TP1X air-purifier family's
modes (Smart/Max/Mid/WindFree/Sleep, issue #130) and the A-VTWW-TP2-21
family's /wind/strength/vs/0 modes (issue #151) are both named behaviors
with no linear order (PRESET_MODE) -- LocalThingsAirPurifierFan handles
both hrefs, the only difference being whether the label comes straight
from supportedModes or from a parallel modesName array (see
_label_for_code)."""
from __future__ import annotations
import logging
from homeassistant.components.fan import FanEntity, FanEntityFeature
from homeassistant.config_entries import ConfigEntry
from homeassistant.core import HomeAssistant
@@ -14,13 +30,23 @@ from homeassistant.util.percentage import (
from .const import DOMAIN
from .coordinator import LocalThingsCoordinator
from .entity import LocalThingsEntity, _is_included
from .registry.capabilities.air_purifier import HREF_AIRFLOW
from .registry.capabilities.air_purifier import HREF_MODE as AIR_PURIFIER_FAN_HREF
from .registry.capabilities.air_purifier import HREF_WIND_STRENGTH as AIR_PURIFIER_WIND_STRENGTH_HREF
from .registry.entities import FanDesc
_LOGGER = logging.getLogger(__name__)
POWER_HREF = '/power/0'
POWER_VS_HREF = '/power/vs/0'
_FAN_SPEED_FIELD = 'x.com.samsung.da.hood.fanSpeed'
_SUPPORTED_FAN_SPEED_FIELD = 'x.com.samsung.da.hood.supportedFanSpeed'
_MIN_FAN_SPEED_FIELD = 'x.com.samsung.da.hood.settableMinFanSpeed'
_OFF_SPEED_CODE = '0'
_MODES_FIELD = 'x.com.samsung.da.modes'
_SUPPORTED_MODES_FIELD = 'x.com.samsung.da.supportedModes'
_MODES_NAME_FIELD = 'x.com.samsung.da.modesName'
async def async_setup_entry(
@@ -29,15 +55,38 @@ async def async_setup_entry(
async_add_entities: AddEntitiesCallback,
) -> None:
coordinator: LocalThingsCoordinator = hass.data[DOMAIN][entry.entry_id]
async_add_entities(
LocalThingsRangeHoodFan(coordinator, bound)
for bound in coordinator.bound
if isinstance(bound.desc, FanDesc) and _is_included(bound, coordinator)
)
entities = []
for bound in coordinator.bound:
if not (isinstance(bound.desc, FanDesc) and _is_included(bound, coordinator)):
continue
if bound.href in (AIR_PURIFIER_FAN_HREF, AIR_PURIFIER_WIND_STRENGTH_HREF):
entities.append(LocalThingsAirPurifierFan(coordinator, bound))
elif bound.href == HREF_AIRFLOW:
entities.append(LocalThingsAirflowFan(coordinator, bound))
else:
entities.append(LocalThingsRangeHoodFan(coordinator, bound))
async_add_entities(entities)
class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
"""A hood fan combining sibling power and fan-speed resources."""
"""A hood fan combining sibling power and fan-speed resources.
Some boards that reuse this capability (built-in microwave vent fans,
issues #137/#142) report no sibling `/power/0` or `/power/vs/0`
resource at all -- fan speed 0 is itself the off state there, with no
separate power toggle to write. `_speed_zero_is_off` detects that
shape from the hood resource's own settableMinFanSpeed/
supportedFanSpeed fields and switches every method below to drive
off/on purely through the fanSpeed field, including '0' in the
ordered speed codes as the off step instead of assuming every
advertised code is an active speed.
This is deliberately not the same question as `_has_separate_power`,
which only proves *some* power resource exists on the device -- on a
combi appliance (e.g. an over-the-range microwave) that resource can
belong to the cavity, not the vent fan, and toggling it from here
would turn off the whole appliance instead of just the fan.
"""
_enable_turn_on_off_backwards_compatibility = False
_attr_supported_features = (
@@ -53,15 +102,35 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
def _rep(self, href: str) -> dict:
return self.coordinator.resource(href) or {}
def _has_separate_power(self) -> bool:
return bool(self._rep(POWER_HREF)) or bool(self._rep(POWER_VS_HREF))
def _speed_zero_is_off(self) -> bool:
"""Whether fan speed '0' is itself this hood's off step, with no
separate power resource to toggle. The board says so directly:
settableMinFanSpeed '0', or '0' inside supportedFanSpeed. The
standalone hood's codes start at 14 and it carries a real /power
resource instead, so this is False there."""
rep = self._rep(self._bound.href)
return (
str(rep.get(_MIN_FAN_SPEED_FIELD, '')) == _OFF_SPEED_CODE
or _OFF_SPEED_CODE in self._all_speed_codes()
)
def _all_speed_codes(self) -> list[str]:
rep = self._rep(self._bound.href)
return [str(value) for value in rep.get(_SUPPORTED_FAN_SPEED_FIELD, ())]
def _active_speed_codes(self) -> list[str]:
# Power is carried by the separate /power resource. fanSpeed retains
# the selected setting while power is off (as the lamp's `current`
# field does), so every advertised code is an active ordered speed.
return self._all_speed_codes()
codes = self._all_speed_codes()
if self._speed_zero_is_off():
# No separate power resource: '0' is the off step, not a speed.
return [code for code in codes if code != _OFF_SPEED_CODE]
# Power is carried by the separate /power resource. fanSpeed
# retains the selected setting while power is off (as the
# lamp's `current` field does), so every advertised code is an
# active ordered speed.
return codes
def _power_payload(self, enabled: bool) -> tuple[str, bool, str]:
"""Target whichever power resource this hood actually exposes."""
@@ -71,6 +140,9 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
@property
def is_on(self) -> bool:
if self._speed_zero_is_off():
current = str(self._rep(self._bound.href).get(_FAN_SPEED_FIELD, '0'))
return current not in ('', _OFF_SPEED_CODE)
rep = self._rep(POWER_HREF)
if 'value' in rep:
return bool(rep.get('value'))
@@ -96,6 +168,18 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
self, percentage: int | None = None, preset_mode: str | None = None,
**kwargs,
) -> None:
if self._speed_zero_is_off():
if percentage is not None:
await self.async_set_percentage(percentage)
return
if self.is_on:
# Already running: no percentage given means "just turn on",
# not "reset to the lowest speed".
return
codes = self._active_speed_codes()
if codes:
await self.coordinator.async_send_command(self._bound, ('speed', codes[0]))
return
await self.coordinator.async_send_command(
self._bound, self._power_payload(True),
)
@@ -103,6 +187,9 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
await self.async_set_percentage(percentage)
async def async_turn_off(self, **kwargs) -> None:
if self._speed_zero_is_off():
await self.coordinator.async_send_command(self._bound, ('speed', _OFF_SPEED_CODE))
return
await self.coordinator.async_send_command(
self._bound, self._power_payload(False),
)
@@ -114,9 +201,189 @@ class LocalThingsRangeHoodFan(LocalThingsEntity, FanEntity):
codes = self._active_speed_codes()
if not codes:
return
if not self.is_on:
if not self._speed_zero_is_off() and not self.is_on:
await self.coordinator.async_send_command(
self._bound, self._power_payload(True),
)
code = percentage_to_ordered_list_item(codes, percentage)
await self.coordinator.async_send_command(self._bound, ('speed', code))
class LocalThingsAirPurifierFan(LocalThingsEntity, FanEntity):
"""Air-purifier fan: named preset modes, not an ordered percentage --
see air_purifier.FAN's comment for why (Smart/WindFree/Sleep aren't
"faster/slower" than Max/Mid)."""
_enable_turn_on_off_backwards_compatibility = False
_attr_supported_features = (
FanEntityFeature.PRESET_MODE
| FanEntityFeature.TURN_ON
| FanEntityFeature.TURN_OFF
)
def __init__(self, coordinator: LocalThingsCoordinator, bound) -> None:
super().__init__(coordinator, bound)
self._attr_name = None
def _rep(self, href: str) -> dict:
return self.coordinator.resource(href) or {}
def _mode_rep(self) -> dict:
return self._rep(self._bound.href)
def _power_payload(self, enabled: bool) -> tuple[str, bool, str]:
"""Target whichever power resource this unit actually exposes --
same pattern as LocalThingsRangeHoodFan._power_payload above.
Writing a hardcoded href here would silently no-op on a board that
only reports the other one, even though is_on already falls back
correctly."""
resources = self.coordinator.last_resources
target = POWER_VS_HREF if POWER_VS_HREF in resources else POWER_HREF
return 'power', enabled, target
@property
def is_on(self) -> bool:
power = self._rep(POWER_VS_HREF).get('x.com.samsung.da.power')
if power is not None:
return str(power).lower() == 'on'
return bool(self._rep(POWER_HREF).get('value'))
def _label_for_code(self, code) -> str:
"""Lowercased HA preset label for a device mode code.
The TP1X_DA-AC-AIR board (issue #130) reports its named modes
directly as supportedModes ('Smart'/'Max'/...), so the code IS the
label. The A-VTWW-TP2-21 board (issue #151) instead reports numeric
wind-strength codes ('87'/'89'/...) with a separate modesName array
(parallel-indexed with supportedModes) giving the actual names --
same shape as climate.py's _wind_strength_label, and coincidentally
the same word set (Smart/Max/WindFree/Sleep), so both board
generations land on identical HA preset values without needing
their own translation catalog entry."""
rep = self._mode_rep()
supported = list(rep.get(_SUPPORTED_MODES_FIELD, ()))
names = rep.get(_MODES_NAME_FIELD)
if names and code in supported and len(names) == len(supported):
return str(names[supported.index(code)]).lower()
return str(code).lower()
@property
def preset_modes(self) -> list[str]:
return [
self._label_for_code(code)
for code in self._mode_rep().get(_SUPPORTED_MODES_FIELD, ())
]
@property
def preset_mode(self) -> str | None:
modes = self._mode_rep().get(_MODES_FIELD)
code = modes[0] if isinstance(modes, (list, tuple)) and modes else modes
return self._label_for_code(code) if code is not None else None
async def async_turn_on(
self, percentage: int | None = None, preset_mode: str | None = None,
**kwargs,
) -> None:
await self.coordinator.async_send_command(self._bound, self._power_payload(True))
if preset_mode is not None:
await self.async_set_preset_mode(preset_mode)
async def async_turn_off(self, **kwargs) -> None:
await self.coordinator.async_send_command(self._bound, self._power_payload(False))
async def async_set_preset_mode(self, preset_mode: str) -> None:
# Reverse-resolve against the unit's own supportedModes -- the
# write needs the raw device code (e.g. 'WindFree', or '90' on the
# modesName-labelled board), not the lowercased HA value.
for code in self._mode_rep().get(_SUPPORTED_MODES_FIELD, ()):
if self._label_for_code(code) == preset_mode:
await self.coordinator.async_send_command(self._bound, ('mode', code))
return
_LOGGER.warning(
"%s: %r is not a valid preset mode (supported: %s)",
self.entity_id, preset_mode, self.preset_modes,
)
_AIRFLOW_SPEED_FIELD = 'speed'
# Raw `speed` codes, low-to-high -- confirmed monotonic (Auto=0, Sleep=1,
# Low=2, Medium=3, High=4) via air_purifier.py's module docstring. Ordered
# as plain strings, same as _all_speed_codes above, so
# ordered_list_item_to_percentage/percentage_to_ordered_list_item can treat
# it exactly like the range hood's numeric levels -- no named-preset table
# needed since this board never reports mode names to hang one off of.
_AIRFLOW_SPEED_CODES = ('0', '1', '2', '3', '4')
class LocalThingsAirflowFan(LocalThingsEntity, FanEntity):
"""ARTIK051_TVTL-class air purifier fan (issue #56): an ordered numeric
speed range, same SET_SPEED shape as LocalThingsRangeHoodFan above."""
_enable_turn_on_off_backwards_compatibility = False
_attr_supported_features = (
FanEntityFeature.SET_SPEED
| FanEntityFeature.TURN_ON
| FanEntityFeature.TURN_OFF
)
def __init__(self, coordinator: LocalThingsCoordinator, bound) -> None:
super().__init__(coordinator, bound)
self._attr_name = None
def _rep(self, href: str) -> dict:
return self.coordinator.resource(href) or {}
def _power_payload(self, enabled: bool) -> tuple[str, bool, str]:
"""Prefer /power/0 like LocalThingsRangeHoodFan above, NOT
LocalThingsAirPurifierFan's vs/0-first order -- that order is only
harmless for the TP1X board because it never reports /power/0 at
all. This family's dumps carry both hrefs, and common.POWER_GENERIC
(the power_switch entity) is unconditionally bound to /power/0
whenever it's present, so writing here to /power/vs/0 first would
leave power_switch and this fan reading/writing two different
resources -- disagreeing until the next poll refreshes the other
one (the same optimistic-apply lag coordinator.py's own comments
warn about)."""
resources = self.coordinator.last_resources
target = POWER_HREF if POWER_HREF in resources else POWER_VS_HREF
return 'power', enabled, target
@property
def is_on(self) -> bool:
power = self._rep(POWER_HREF)
if 'value' in power:
return bool(power.get('value'))
return str(self._rep(POWER_VS_HREF).get('x.com.samsung.da.power', '')).lower() == 'on'
@property
def speed_count(self) -> int:
return len(_AIRFLOW_SPEED_CODES)
@property
def percentage(self) -> int | None:
if not self.is_on:
return 0
current = str(self._rep(self._bound.href).get(_AIRFLOW_SPEED_FIELD, ''))
if current not in _AIRFLOW_SPEED_CODES:
return None
return ordered_list_item_to_percentage(_AIRFLOW_SPEED_CODES, current)
async def async_turn_on(
self, percentage: int | None = None, preset_mode: str | None = None,
**kwargs,
) -> None:
await self.coordinator.async_send_command(self._bound, self._power_payload(True))
if percentage is not None:
await self.async_set_percentage(percentage)
async def async_turn_off(self, **kwargs) -> None:
await self.coordinator.async_send_command(self._bound, self._power_payload(False))
async def async_set_percentage(self, percentage: int) -> None:
if percentage <= 0:
await self.async_turn_off()
return
if not self.is_on:
await self.coordinator.async_send_command(self._bound, self._power_payload(True))
code = percentage_to_ordered_list_item(_AIRFLOW_SPEED_CODES, percentage)
await self.coordinator.async_send_command(self._bound, ('speed', int(code)))
+66
View File
@@ -0,0 +1,66 @@
{
"entity": {
"climate": {
"airconditioner": {
"state_attributes": {
"fan_mode": {
"state": {
"1": "mdi:fan-speed-1",
"2": "mdi:fan-speed-1",
"3": "mdi:fan-speed-2",
"4": "mdi:fan-speed-3",
"5": "mdi:fan-speed-3",
"turbo": "mdi:fan-speed-3",
"max": "mdi:fan-speed-3"
}
},
"preset_mode": {
"state": {
"ai_comfort": "mdi:creation",
"quiet": "mdi:volume-off",
"smart": "mdi:brain",
"speed": "mdi:speedometer",
"nano": "mdi:weather-dust",
"nanosleep": "mdi:sleep",
"longwind": "mdi:weather-windy",
"motiondirect": "mdi:account-arrow-left",
"motionindirect": "mdi:account-arrow-right",
"drycomfort": "mdi:water-percent",
"2step": "mdi:stairs"
}
}
}
}
},
"fan": {
"air_purifier_fan": {
"state_attributes": {
"preset_mode": {
"state": {
"smart": "mdi:brain",
"max": "mdi:fan-speed-3",
"mid": "mdi:fan-speed-2",
"windfree": "mdi:weather-dust",
"sleep": "mdi:sleep"
}
}
}
}
},
"sensor": {
"machine_state": {
"state": {
"idle": "mdi:power-standby",
"active": "mdi:play",
"pause": "mdi:pause"
}
},
"connection_mode": {
"state": {
"observe": "mdi:broadcast",
"poll": "mdi:sync"
}
}
}
}
}
+2 -2
View File
@@ -10,7 +10,7 @@
"requirements": [
"cbor2>=5.4.6",
"pyOpenSSL>=23.0",
"smartthings-local>=0.1.0"
"smartthings-local>=0.1.1"
],
"version": "0.11.1"
"version": "0.15.0"
}
@@ -2,8 +2,25 @@
from __future__ import annotations
def is_stub_rep(rep: dict) -> bool:
"""True for the device's "resource exists, no data fetched yet" marker --
an echoed {"href": "..."} with no other fields.
Distinct from a genuinely empty {} rep, which is the device's confirmed
(if empty) answer -- e.g. an unsupported resource on this model that will
never populate. Conflating the two used to make every field-gated entity
on a permanently-empty resource look like a not-yet-fetched stub forever,
creating phantom always-"unknown" entities (issue #127)."""
return isinstance(rep, dict) and set(rep.keys()) == {'href'}
def parse_device0_batch(device0: list) -> dict[str, dict]:
"""Extract {href: rep} from a /device/0 CBOR list response."""
"""Extract {href: rep} from a /device/0 CBOR list response.
A stub rep is passed through unchanged rather than collapsed to {} --
downstream code (entity._is_included, capability exists_fns) uses
is_stub_rep to tell "not fetched yet" apart from a confirmed-empty {}.
"""
out = {}
for entry in device0[1:]: # skip [0] (device-level rep)
if not isinstance(entry, dict):
@@ -12,8 +29,6 @@ def parse_device0_batch(device0: list) -> dict[str, dict]:
rep = entry.get('rep')
if not href:
continue
# rep == {"href": "..."} is a stub (resource present, no current data).
# Include it as {} so capabilities still bind and the entity exists.
if isinstance(rep, dict):
out[href] = {} if set(rep.keys()) == {'href'} else rep
out[href] = rep
return out
@@ -1,77 +1,42 @@
"""Per-device-type registries."""
import re
from typing import Optional
from ._base import DeviceRegistry
from . import (
air_purifier, airconditioner, cooktop, dishwasher, dryer, oven,
range as _range, range_hood, refrigerator, washer,
air_dresser, air_purifier, airconditioner, cooktop, dehumidifier,
dishwasher, dryer, induction_cooktop, microwave, oven, range as _range,
range_hood, refrigerator, vacuum_station, washer, water_purifier,
)
__all__ = [
'DeviceRegistry', '_type_key', 'for_device', 'for_device_by_model',
'for_device_by_resources',
'DeviceRegistry', 'resolve', 'for_device_by_model',
'for_device_by_resources', '_board_tokens',
]
# One entry per registry, no aliases: every key here is reachable from
# `_BOARD_TOKEN_TO_KEY`, `_CONSUMER_PREFIX_TO_KEY`, or `for_device_by_resources`.
_REGISTRY_BY_KEY: dict[str, DeviceRegistry] = {
'air_dresser': air_dresser.REGISTRY,
'air_purifier': air_purifier.REGISTRY,
'airpurifier': air_purifier.REGISTRY,
'airconditioner': airconditioner.REGISTRY,
'air_conditioner': airconditioner.REGISTRY,
'cooktop': cooktop.REGISTRY,
'dehumidifier': dehumidifier.REGISTRY,
'dishwasher': dishwasher.REGISTRY,
'dryer': dryer.REGISTRY,
'induction_cooktop': induction_cooktop.REGISTRY,
'microwave': microwave.REGISTRY,
'oven': oven.REGISTRY,
'hood': range_hood.REGISTRY,
'range': _range.REGISTRY,
'range_hood': range_hood.REGISTRY,
'refrigerator': refrigerator.REGISTRY,
'vacuum_station': vacuum_station.REGISTRY,
'washer': washer.REGISTRY,
'water_purifier': water_purifier.REGISTRY,
}
def _type_key(one_ui_version: str) -> str:
"""Convert oneUiVersion string to registry key.
Args:
one_ui_version: String like '7.0 Dishwasher' or 'Oven'.
Returns:
Lowercase key with version prefix stripped and spaces/hyphens converted to underscores.
Examples:
'7.0 Dishwasher' -> 'dishwasher'
'7.0 French Door Refrigerator' -> 'french_door_refrigerator'
'Oven' -> 'oven'
"""
if ' ' in one_ui_version:
# Strip version prefix: everything before and including the first space
suffix = one_ui_version.split(' ', 1)[-1]
else:
suffix = one_ui_version
return suffix.lower().replace(' ', '_').replace('-', '_')
def for_device(one_ui_version: str) -> Optional[DeviceRegistry]:
"""Return the DeviceRegistry for the given oneUiVersion string, or None if unknown.
Args:
one_ui_version: Device's oneUiVersion string (e.g., '7.0 Dishwasher').
Returns:
DeviceRegistry if a matching registry exists, None otherwise.
"""
key = _type_key(one_ui_version)
if key in _REGISTRY_BY_KEY:
return _REGISTRY_BY_KEY[key]
# Suffix fallback: e.g. "french_door_refrigerator" ends with "_refrigerator"
for rkey, reg in _REGISTRY_BY_KEY.items():
if key.endswith(f'_{rkey}'):
return reg
return None
# Consumer-model prefix (first two letters of the '_'-delimited token in
# `description` right before any '/board-info' suffix) -> registry key.
# NOT derived from `modelNum` -- washer and dryer share the same 'DA_WM_'
@@ -82,76 +47,176 @@ _CONSUMER_PREFIX_TO_KEY: dict[str, str] = {
'WD': 'washer',
'WF': 'washer',
'WV': 'washer', # FlexWash twin units (e.g. WV55M9600AW) -- issue #19
'WA': 'washer', # Top-load washers (e.g. WA8000T) -- issue #106
'DV': 'dryer',
'DW': 'dishwasher',
}
# Board-family token -> registry key, matched against whole tokens of
# `modelNum`/`description` (see `_board_tokens`).
#
# Tokenizing instead of substring-matching is what keeps this a table rather
# than a ladder of hand-written rules. Samsung spells the same board family
# with either delimiter -- 'TP1X_DA-AC-RAC-01001' and 'TP2X_RAC_20K' are the
# same RAC family -- so a substring rule has to be written once per spelling
# ('_RAC_' *and* '-RAC-'), and a token that lands at the end of the
# pipe-prefix with no trailing delimiter ('ARTIK051_DONGLE_REF', issues #77
# and #83) matches no '_TOKEN_' spelling at all. Whole-token matching sees
# every one of those as a single entry.
#
# Entries must name the *specific* device type, never the board family that
# contains it: 'DA-AC-' prefixes RAC/WAC/DHM/AIR alike, so a bare 'AC' entry
# would swallow the dehumidifier and the air purifier. Where two families
# genuinely share a resource surface they share a registry (all the
# air-conditioner spellings below), which is a statement about the hardware,
# not a shortcut.
_BOARD_TOKEN_TO_KEY: dict[str, str] = {
'REF': 'refrigerator',
# Air conditioners. Every one of these is a distinct board family with
# the same resource surface: room (issues #37, #91), package, Korean
# (#136), window (#87), 2-in-1 floor+wall (#150, #153), system/commercial
# (#52), and ARA-WW wall-mount (#115, #116, #117, #120).
'RAC': 'airconditioner',
'PRAC': 'airconditioner',
'KRAC': 'airconditioner',
'WAC': 'airconditioner',
'FAC': 'airconditioner',
'CAWW': 'airconditioner',
'ARA': 'airconditioner',
'DHM': 'dehumidifier', # issue #88 -- target humidity, no climate
'TVTL': 'air_purifier', # issue #56 (ARTIK051)
'VTWW': 'air_purifier', # issue #151 (BESPOKE Cube Air)
'AIR': 'air_purifier', # issue #130 (TP1X_DA-AC-AIR)
'WATERPURIFIER': 'water_purifier', # issue #90
'ADW': 'dishwasher',
'AHD': 'range_hood',
'RANGE': 'range', # issue #44 -- cooktop+oven combo
'OVEN': 'oven', # issue #55 -- wall oven, no burners
'MICROWAVE': 'microwave', # issues #66, #121
'COOKTOP': 'induction_cooktop', # issue #86 -- standalone, no oven
# Legacy ARTIK051 gas cooktops ('ARTIK051_GB_CT_001'), whose burner state
# lives in /mode/vs/0's options array. Deliberately a bare two-letter
# token, and so the loosest entry in this table -- it is only ever
# reached by a device that matched nothing more specific, and its
# `description` ('ARTIK051_GLOBAL_COOKTOP') would otherwise read as an
# induction cooktop via the COOKTOP entry above. See `for_device_by_model`
# for the field ordering that makes that resolve correctly.
'CT': 'cooktop',
'VSKR': 'vacuum_station', # issue #131 -- stick-vacuum clean station
'DF': 'air_dresser', # issue #162
}
_TOKEN_SPLIT_RE = re.compile(r'[^A-Z0-9]+')
def _board_tokens(value: str, cut_at: str) -> list[str]:
"""Whole, upper-cased tokens of `value` up to the first `cut_at`.
`cut_at` drops the trailing junk each field carries -- everything after
modelNum's first '|' (a board revision and a capability bitmap, which can
contain anything) and after description's first '/' (a '/DC92-...' board
part number).
"""
head = (value or '').split(cut_at, 1)[0].upper()
return [t for t in _TOKEN_SPLIT_RE.split(head) if t]
def _board_family_key(value: str, cut_at: str) -> Optional[str]:
"""First `_BOARD_TOKEN_TO_KEY` hit among `value`'s tokens, or None.
No known modelNum or description yields two *conflicting* board keys, so
which token is found first doesn't matter within one field -- the table is
a flat lookup, not a priority list. Adding an entry that could co-occur
with another (a family token, or one short enough to collide by accident)
would break that property; see this table's comment.
"""
for token in _board_tokens(value, cut_at):
key = _BOARD_TOKEN_TO_KEY.get(token)
if key is not None:
return key
return None
def _consumer_model_key(description: str) -> Optional[str]:
"""Registry key from the consumer-model token in `description`, or None.
Usually that token is the last '_'-delimited segment before any
'/board-info' suffix (e.g. '..._WW90DG6U25LEU4' -> 'WW90DG6U25LEU4').
But issue #79's dryer pairs two model numbers in one description --
'..._DVE50A8800_8600/DC92-...' -- so the true consumer token
('DVE50A8800') sits one segment *before* the actual last segment
('8600', a bare second model number with no recognizable prefix). Scan
segments from the end and take the first one that resolves, rather
than assuming the last segment is always it.
Splits on '_' only, unlike `_board_tokens` above: these are two-letter
prefixes matched against the *start* of a segment, so widening the split
to '-' as well would start reading board-family segments as consumer
models -- the dishwasher's 'ADW-WW-RTL-24-AILITE' would offer up a bare
'WW' segment and route to washer.
Only a 2-letter *prefix* match -- e.g. 'WAC' (the Window Air Conditioner
board-family token, issue #87) also starts with 'WA' (the top-load-washer
prefix, issue #106) at this granularity. for_device_by_model() consults
the board-family table first and this function only as a fallback, so
that ambiguity resolves correctly without this function needing to know
about unrelated device families.
"""
segments = (description or '').split('/', 1)[0].split('_')
for segment in reversed(segments):
key = _CONSUMER_PREFIX_TO_KEY.get(segment[:2].upper())
if key is not None:
return key
return None
def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegistry]:
"""Fallback device-type detection for hardware that never reports
oneUiVersion (confirmed for washers -- their /otninformation/vs/0 has
no swVersionInfo key at all).
"""Device-type detection from /information/vs/0's model strings.
The primary path: the board named in `modelNum` determines the resource
surface, which is what a registry describes.
Three passes, narrowest evidence first:
1. Board-family tokens in `modelNum`. The most reliable signal -- it names
the board, which determines the resource surface.
2. The same tokens in `description`. Some units carry the board token only
there (a scrubbed or placeholder modelNum, e.g. description
'TP1X_REF_21K'). This runs second so that a device whose two fields
disagree is typed by its modelNum: the legacy gas cooktop reports
'ARTIK051_GB_CT_001' (CT -> gas cooktop) alongside
'ARTIK051_GLOBAL_COOKTOP' (COOKTOP -> induction cooktop), and the
board is right.
3. The consumer-model prefix in `description` (washer/dryer/dishwasher).
Last, because a bare two-letter prefix is the fuzziest evidence here
and would otherwise shadow the specific board tokens above.
Args:
model_num: x.com.samsung.da.modelNum from /information/vs/0.
description: x.com.samsung.da.description from /information/vs/0.
Returns:
DeviceRegistry if the consumer-model code or modelNum resolves to a
DeviceRegistry if the modelNum or consumer-model code resolves to a
known type, None otherwise.
"""
token = (description or '').split('/', 1)[0].rsplit('_', 1)[-1]
key = _CONSUMER_PREFIX_TO_KEY.get(token[:2].upper())
if key is None and '_REF_' in (model_num or ''):
key = 'refrigerator'
# Room air conditioners (e.g. ARTIK051_PRAC_20K) report no oneUiVersion and
# a modelNum carrying the '_PRAC_' (Package Room Air Conditioner) token.
if key is None and '_PRAC_' in (model_num or ''):
key = 'airconditioner'
# Older/simpler RAC boards (e.g. TP2X_RAC_20K, issue #37) use the plain
# '_RAC_' token instead -- distinct from '_PRAC_' above (no overlap: the
# 'P' sits between the underscore and 'RAC' in that token).
if key is None and '_RAC_' in (model_num or ''):
key = 'airconditioner'
# System air conditioners (multi-indoor-unit commercial installs, e.g.
# A-CAWW-TP2-20-COMMON, issue #52) report no oneUiVersion either and
# carry the '-CAWW-' board-family token instead of '_RAC_'/'_PRAC_'.
# Same TP1X/TP2X-class resource surface as the room-AC models above
# (confirmed by the issue #52 dump binding cleanly against the existing
# airconditioner registry once routed here), plus one new SAC-specific
# resource (see airconditioner.py's _AC_IGNORED).
if key is None and '-CAWW-' in (model_num or '').upper():
key = 'airconditioner'
# Air purifiers (e.g. ARTIK051_TVTL_18K, issue #56) report no
# oneUiVersion either, and carry the '_TVTL_' board-family token.
if key is None and '_TVTL_' in (model_num or ''):
key = 'air_purifier'
model_identity = f'{model_num} {description}'.upper()
if key is None and ('_COOKTOP' in model_identity or '_GB_CT_' in model_identity):
key = 'cooktop'
if key is None and model_identity.startswith('AHD-'):
key = 'range_hood'
# Range/cooktop-oven combos (e.g. TP1X_DA-KS-RANGE-0102X, issue #44) --
# like the RAC/PRAC air conditioners above, these report no oneUiVersion
# and don't match the washer/dryer/dishwasher consumer-prefix map either.
if key is None and '-RANGE-' in (model_num or '').upper():
key = 'range'
# Wall ovens (e.g. TP1X_DA-KS-OVEN-0107X, issue #55) -- same board-family
# naming as the range combo above, minus the burners; also reports no
# oneUiVersion and doesn't match the washer/dryer/dishwasher prefix map.
if key is None and '-OVEN-' in (model_num or '').upper():
key = 'oven'
key = (
_board_family_key(model_num, '|')
or _board_family_key(description, '/')
or _consumer_model_key(description)
)
return _REGISTRY_BY_KEY.get(key) if key else None
def for_device_by_resources(resources: dict[str, dict]) -> Optional[DeviceRegistry]:
"""Detect a device family from a distinctive local-resource signature.
Some newer cooktops omit both ``oneUiVersion`` and
``/information/vs/0``. Their mode resource still identifies them: it
contains a DeviceType option and multiple per-burner OperationState
options. Require both shapes so an oven's unrelated ``/mode/vs/0`` is
not misclassified.
For boards that ship no ``/information/vs/0`` at all, leaving
`for_device_by_model` nothing to read. Some newer cooktops are the
original case: their mode resource still identifies them, carrying a
DeviceType option and multiple per-burner OperationState options.
Require two independent shapes for every signature here, never one, so
an unrelated family's ``/mode/vs/0`` isn't misclassified.
"""
mode = resources.get('/mode/vs/0', {})
options = mode.get('x.com.samsung.da.options') or ()
@@ -170,4 +235,45 @@ def for_device_by_resources(resources: dict[str, dict]) -> Optional[DeviceRegist
and '/hood/lamp/vs/0' in resources
):
return _REGISTRY_BY_KEY['range_hood']
# Oven/range/microwave boards that report no /information/vs/0 at all
# (issue #74's NE63B8411SS, issue #172's ME8000T -- the resource is simply
# absent from the dump, not just empty) can't be matched via
# for_device_by_model's modelNum tokens either. Mode vocabulary alongside
# the oven cavity resource (/oven/vs/0) is a safe signature.
supported_modes = mode.get('x.com.samsung.da.supportedModes') or ()
if '/oven/vs/0' in resources:
if any(
m in supported_modes
for m in ('MicroWave', 'MicroWaveGrill', 'MicroWaveConvection')
):
return _REGISTRY_BY_KEY['microwave']
if 'Bake' in supported_modes:
if '/cooktopmonitoring/vs/0' in resources or '/cooktop/status/vs/0' in resources:
return _REGISTRY_BY_KEY['range']
return _REGISTRY_BY_KEY['oven']
return None
def resolve(resources: dict[str, dict]) -> Optional[DeviceRegistry]:
"""Device type for a parsed /device/0 dump, or None if unrecognized.
The single entry point for detection -- the coordinator, the config
flow's probe and the golden-regression harness all call this, so the
order can't drift between what ships and what the tests assert.
Model strings first (`for_device_by_model`), then a distinctive resource
signature (`for_device_by_resources`) for boards that report no
/information/vs/0 at all.
`/otninformation/vs/0`'s oneUiVersion is deliberately not consulted. It
reads like the obvious signal -- the device naming its own type, e.g.
'7.0 Dishwasher' -- but only a minority of hardware populates it, every
device that does is already typed by its modelNum board token, and no
device-support issue has ever been fixed by adding a mapping for it. It
is still reported in diagnostics as a firmware-generation marker.
"""
info = resources.get('/information/vs/0', {})
return for_device_by_model(
info.get('x.com.samsung.da.modelNum', ''),
info.get('x.com.samsung.da.description', ''),
) or for_device_by_resources(resources)
@@ -0,0 +1,24 @@
"""AirDresser device registry (issue #162).
Reuses washer/dryer/dishwasher's shared laundry surface -- job-beginning
status, operational state, and diagnosis. air_dresser.py holds the two
pieces specific to this device type: a minimal wrinkle-prevent-only
/washer/vs/0 capability, and the course select's own translation key.
"""
from ..capabilities import air_dresser, common, dishwasher, ignored, laundry, operational
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='air_dresser',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*common.POWER,
air_dresser.AIR_DRESSER_SETTINGS,
air_dresser.AIR_DRESSER_COURSE,
air_dresser.AIR_DRESSER_SANITIZE,
laundry.JOB_BEGINNING_STATUS,
operational.OPERATIONAL_STATE,
dishwasher.DIAGNOSIS,
]),
)
@@ -1,10 +1,26 @@
"""Air-purifier device registry (Samsung ARTIK051_TVTL-class, issue #56).
"""Air-purifier device registry.
Reports no oneUiVersion; resolved via for_device_by_model's '_TVTL_' modelNum
token (see registry.py). Reuses dishwasher.DIAGNOSIS for /diagnosis/vs/0
(identical field/write contract).
Spans three board generations sharing this one registry (see
capabilities/air_purifier.py's module docstring for the per-href
match_fn discriminators that keep them from colliding):
- ARTIK051_TVTL-class (issue #56). Resolved via the 'TVTL' modelNum board
token (see by_type/__init__.py).
- TP1X_DA-AC-AIR-class (issue #130). Resolved via the 'AIR' board token.
Adds real fan-mode control plus
display/HEPA-filter/pet-filter/sound resources the older family never
reported; reuses airconditioner.DISPLAY_LIGHT and airconditioner.MUTE_ONCE
for /light/vs/0 and /option/muteonce/vs/0, which are identical shapes on
the shared DA-AC- board family.
- A-VTWW-TP2-21-COMMON-class (issue #151). Resolved via the 'VTWW' board
token, added for it. Its fan
is WIND_STRENGTH_FAN on /wind/strength/vs/0 rather than FAN on
/mode/vs/0 -- see that capability's comment.
Reuses dishwasher.DIAGNOSIS for /diagnosis/vs/0 (identical field/write
contract).
"""
from ..capabilities import air_purifier, common, dishwasher, ignored
from ..capabilities import air_purifier, airconditioner, common, dishwasher, ignored
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
@@ -20,6 +36,17 @@ REGISTRY = DeviceRegistry(
air_purifier.AIRFLOW_GENERIC,
air_purifier.AIRFLOW_VS_FALLBACK,
air_purifier.MODE,
air_purifier.FAN,
air_purifier.WIND_STRENGTH_FAN,
air_purifier.DISPLAY,
air_purifier.HEPA_FILTER,
air_purifier.PANEL_STATUS,
air_purifier.PET_FILTER_ACTIVATION,
air_purifier.SOUND_MODE,
air_purifier.SOUND_OUTPUT,
air_purifier.SOUND_VOLUME,
airconditioner.DISPLAY_LIGHT,
airconditioner.MUTE_ONCE,
*air_purifier.COVERAGE,
]),
)
@@ -22,9 +22,16 @@ REGISTRY = DeviceRegistry(
airconditioner.AIR_PURIFY,
airconditioner.AUTO_CLEAN,
airconditioner.AIR_FILTER,
airconditioner.AIR_QUALITY,
airconditioner.DISPLAY_LIGHT,
airconditioner.MUTE_ONCE,
airconditioner.CURRENT_LIMIT,
airconditioner.ANOMALY_LOAD,
airconditioner.ABSENCE_POWER_SAVING,
airconditioner.MOTION_DETECT_WIND,
airconditioner.CURRENT_TEMPERATURE,
airconditioner.CURRENT_TEMPERATURE_VS,
airconditioner.HUMIDITY,
*airconditioner.COVERAGE,
]),
)
@@ -1,11 +1,20 @@
"""Cooktop device registry."""
"""Gas cooktop device registry (NA9300K-class, PR #23).
Named 'gas_cooktop' (not 'cooktop') so its diagnostics/device-info label
doesn't collide with the unrelated induction_cooktop family (issue #86,
by_type/induction_cooktop.py) -- two different OCF surfaces that happen to
share the English word "cooktop". The `_REGISTRY_BY_KEY['cooktop']` lookup
key is unchanged: it's relied on by the legacy ARTIK051 'CT' modelNum token
(for_device_by_model) and the resource-signature fallback
(for_device_by_resources) alike.
"""
from ..capabilities import common, cooktop, ignored
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='cooktop',
name='gas_cooktop',
capabilities=_build([
*ignored.IGNORED,
cooktop.COOKTOP_POWER,
@@ -0,0 +1,23 @@
"""Dehumidifier device registry (Samsung TP1X_DA_AC_DHM-class, issue #88).
Shares the DA_AC_ board family with airconditioner.py (power, air filter,
auto-clean, mute-once all use the identical resource shapes), so those three
Capability objects are reused directly rather than duplicated.
"""
from ..capabilities import airconditioner, common, dehumidifier, ignored
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='dehumidifier',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*common.POWER,
dehumidifier.MODE,
dehumidifier.HUMIDITY,
airconditioner.AUTO_CLEAN,
airconditioner.AIR_FILTER,
airconditioner.MUTE_ONCE,
*dehumidifier.COVERAGE,
]),
)
@@ -0,0 +1,30 @@
"""Standalone induction-cooktop device registry (Samsung
TP1X_DA-KS-COOKTOP-class, issue #86) -- the cooktop half of the
range/oven board family (see capabilities/range.py), but with no oven
attached at all.
Reuses range.py's COOKTOP_STATUS/COOKTOP_SPEC/COOKTOP_SAFETY/PROBE_STATUS
wholesale (identical resource shapes to the range combo's cooktop half)
and cooktop.PAIRED_HOOD_STATUS for the Bluetooth-paired range hood some
units pair with. Distinct registry key from cooktop.REGISTRY ('cooktop')
-- that family is the unrelated NA9300K-class gas cooktop (burner state
embedded in /mode/vs/0's options array, a completely different OCF
surface that happens to share the English word "cooktop").
"""
from ..capabilities import common, cooktop as cooktop_caps, ignored
from ..capabilities import range as range_caps
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='induction_cooktop',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*common.POWER,
range_caps.COOKTOP_STATUS,
range_caps.COOKTOP_SPEC,
range_caps.COOKTOP_SAFETY,
range_caps.PROBE_STATUS,
cooktop_caps.PAIRED_HOOD_STATUS,
]),
)
@@ -0,0 +1,37 @@
"""Microwave device registry (combi and plain microwaves, issues #66/#121).
Shares the oven board family's cavity/cook-cycle resource shape, so the
operational-state, door, cloud-connected, and quick-recipe-display
Capability objects are reused directly from oven.py rather than duplicated.
Cooking mode, setpoint, cavity power level, and lamp are genuinely
different for this family (different mode vocabulary, different setpoint
bounds, an extra powerLevel field, a differently-named lamp option) and are
defined fresh in capabilities/microwave.py -- see that module's docstring.
Some combi units (built-in over-the-range microwaves, issues #137/#142)
also carry the vent fan's `/hood/fanspeed/vs/0` resource, in the exact same
shape a standalone range hood reports it in -- reused directly from
range_hood.py rather than duplicated. Unlike a standalone hood, this dump
has no sibling `/power/0` or `/power/vs/0` resource; fan.py's
LocalThingsRangeHoodFan falls back to treating fan speed 0 as off in that
case (see its `_speed_zero_is_off` check).
"""
from ..capabilities import common, ignored, microwave, oven, range_hood
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='microwave',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*common.POWER,
microwave.MICROWAVE_CAVITY,
microwave.MICROWAVE_SETPOINT,
microwave.MICROWAVE_MODE,
oven.OVEN_OPERATIONAL_STATE,
oven.OVEN_DOOR,
oven.OVEN_CONNECTED,
oven.OVEN_RECIPE_COOK,
range_hood.HOOD_FAN,
]),
)
@@ -15,5 +15,6 @@ REGISTRY = DeviceRegistry(
oven.OVEN_DOOR,
oven.OVEN_CONNECTED,
oven.OVEN_SPEC,
oven.OVEN_RECIPE_COOK,
]),
)
@@ -25,5 +25,6 @@ REGISTRY = DeviceRegistry(
range_caps.COOKTOP_STATUS,
range_caps.COOKTOP_SPEC,
range_caps.COOKTOP_SAFETY,
range_caps.COOKTOP_MONITORING,
]),
)
@@ -11,6 +11,7 @@ REGISTRY = DeviceRegistry(
range_hood.HOOD_ALARMS,
common.ENERGY_METER,
common.FIRMWARE_UPDATE,
range_hood.AFTER_RUN,
range_hood.HOOD_FAN,
range_hood.HOOD_LAMP,
range_hood.HOOD_FILTER,
@@ -33,8 +33,10 @@ REGISTRY = DeviceRegistry(
]),
pattern_capabilities=[
fridge.TEMP_CURRENT_GENERIC,
fridge.TEMP_SETPOINT_GENERIC,
fridge.TEMP_SETPOINT,
fridge.ICEMAKER_GENERIC,
fridge.DOOR_GENERIC,
fridge.KIMCHI_ZONE,
fridge.KIMCHI_DOOR_GENERIC,
],
)
@@ -0,0 +1,22 @@
"""Stick-vacuum clean/auto-empty station device registry (issue #131).
See capabilities/vacuum_station.py's module docstring for why this only
covers the station's own dustbag/dustbin/UV-sanitize state and not any
vacuum-body control (suction, battery, cleaning mode) -- the diagnostics
dump this was built from reports none of that.
"""
from ..capabilities import common, ignored, vacuum_station
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='vacuum_station',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*common.POWER,
vacuum_station.DUSTBAG,
vacuum_station.DUSTBAG_USAGE,
vacuum_station.DUSTBIN_SETTING,
vacuum_station.CLEANSTATION_STATUS,
]),
)
@@ -0,0 +1,20 @@
"""Water-purifier device registry (Samsung TP2X_WATERPURIFIER-class, issue #90).
"""
from ..capabilities import common, ignored, water_purifier
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='water_purifier',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
common.WATER_FILTER,
water_purifier.DISPENSE,
water_purifier.STATUS,
water_purifier.FAVORITE_CAPACITY,
water_purifier.FAVORITE_HOTWATER,
water_purifier.COFFEE,
water_purifier.LOCK,
*water_purifier.COVERAGE,
]),
)
@@ -0,0 +1,80 @@
"""Capabilities specific to the AirDresser family (Samsung DA_DF-class,
issues #162/#157).
This board family carried no /information/vs/0 token any existing family
routed on, so it gets its own device type (the 'DF' board token) -- but most
of the resources it exposes are already handled by the shared laundry
machinery:
/washer/vs/0 -> AIR_DRESSER_SETTINGS (wrinkle_prevent only -- a
dedicated capability rather than reusing
dryer.DRYER_SETTINGS wholesale: this board never
populates dryLevel/dryTime/dryerType at all, and
those are permanently-empty-not-just-absent
dryer-only fields on an AirDresser, not merely unset
ones, so binding them here would ship three sensors
that can never read anything on this device type)
/course/vs/0 -> AIR_DRESSER_COURSE (cycle select), table id from
/st/airdressercourse/vs/0 (issue #157's
DA_DF_TP2_20_COMMON reports "Table_00"; issue #162's
DA_DF_A51_20_COMMON has no table resource at all and
falls back to the name-only 'cycle' key, same as an
unrecognized table on washer/dryer). Options come
from laundry.cycle_options -- #157's board populates
/wm/editcourse/vs/0's editCourseList directly; #162's
has no editcourse resource at all and falls through
to cycle_options' supportedOptions decode instead.
Course names aren't identified yet for either table
(no code->name mapping was reported), so they render
as their raw codes until named in translations, same
as dryer.py's unidentified codes.
/diagnosis/vs/0 -> reuses dishwasher.DIAGNOSIS
/airdresseroption/sanitize/vs/0 -> AIR_DRESSER_SANITIZE (issue #157 only;
#162's board doesn't report this resource at all)
"""
from ..capability import Capability
from ..entities import SwitchDesc
from .laundry import cycle_select
def _wrinkle_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
return ['washer', 'vs', '0'], {'x.com.samsung.da.wrinklePrevent': p}
def _sanitize_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
return ['airdresseroption', 'sanitize', 'vs', '0'], {'x.com.samsung.da.sanitize': p}
AIR_DRESSER_SETTINGS = Capability(
href='/washer/vs/0',
poll_tier='warm',
entities=(
SwitchDesc(key='wrinkle_prevent', field='x.com.samsung.da.wrinklePrevent',
icon='mdi:iron',
value_fn=lambda v: v == 'On',
write_fn=_wrinkle_write),
),
)
AIR_DRESSER_COURSE = Capability(
href='/course/vs/0',
entities=(
cycle_select(translation_key='air_dresser_cycle', icon='mdi:tshirt-crew',
table_href='/st/airdressercourse/vs/0'),
),
)
AIR_DRESSER_SANITIZE = Capability(
href='/airdresseroption/sanitize/vs/0',
poll_tier='warm',
entities=(
SwitchDesc(key='sanitize', field='x.com.samsung.da.sanitize',
icon='mdi:weather-sunny',
value_fn=lambda v: v == 'On',
write_fn=_sanitize_write),
),
)
@@ -15,6 +15,13 @@ issue #56's follow-up (five diagnostics dumps captured with the physical unit
set to Auto/Sleep/Low/Medium/High):
Light_On / Light_Off -- a plain on/off flag; MODE below models it as a
real switch, RMW-replacing just that one entry.
NOT the same polarity as the AC family's own
Light_On/Light_Off token on its own /mode/vs/0
(airconditioner._display_light_on) -- that one is
confirmed inverted (Light_Off means the panel is
lit) on live hardware. Same token name, same
resource name, different device type and
opposite meaning -- don't unify them.
Comode_Off -- read 'Off' on *every* one of the five dumps,
including High/Low/Medium/Auto -- confirms this
is NOT the fan-speed selector (ruling out the
@@ -32,35 +39,62 @@ set to Auto/Sleep/Low/Medium/High):
automatic side effect of sleep mode, e.g. a
display-dimming level, but that's still a guess).
/airflow/0 and /airflow/vs/0's `speed` still isn't modeled as a real
fan-speed control: across the same five dumps it read 0 for both Auto *and*
High, and 3 for Low/Medium *and* Sleep -- not a monotonic mapping to any
selectable level, and the dumps were all captured within about three minutes
of each other (only one poll cycle apart at this integration's 30s summary
interval), so the values may not have settled after each change before the
diagnostics snapshot was taken. Exposed read-only pending a confirmed,
stable capture -- see the issue #56 discussion for what's needed.
/airflow/0's `speed` is now a real fan-speed control (issue #56 follow-up).
The first round of five dumps above wasn't conclusive -- it read 0 for both
Auto *and* High, and 3 for Low/Medium *and* Sleep, likely because all five
were captured within about a minute of each other, faster than this
integration's own ~30s poll cycle could settle each change. A second round,
captured 60-90s apart per setting on two independent units, confirmed a
clean monotonic mapping instead: Auto=0, Sleep=1, Low=2, Medium=3, High=4.
AIRFLOW_GENERIC below builds an ordered-speed fan off that confirmed 0-4
range -- same SET_SPEED shape as range_hood.py's fan, mapping HA's
percentage steps straight onto the raw code, no named-preset table needed
(unlike the TP1X family's FAN, which exposes real named modes because its
board actually reports a supportedModes list to hang names off of).
/airflow/vs/0's vendor `speedLevel` is NOT used for the same purpose -- it
was unreliable on both units in that second round (Low/Medium collided on
one unit, stuck at 0 throughout on the other), so AIRFLOW_VS_FALLBACK below
stays a plain read-only diagnostic even after this change.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, SensorDesc, SwitchDesc
from .common import int_or_none, sensor_item_value
from ..entities import (
BinarySensorDesc, FanDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc,
)
from .common import filter_usage_percent, int_or_none, sensor_item_value
from .laundry import bool_option_exists, bool_option_value, option_value, option_write
# Newer TP1X_DA-AC-AIR-class boards (e.g. TP1X_DA-AC-AIR-01031_0000, issue
# #130) report fan modes directly on /mode/vs/0's top-level `modes`/
# `supportedModes` fields (Smart/Max/Mid/WindFree/Sleep) instead of packing
# everything into the options[] array the way the older ARTIK051_TVTL
# family above does -- that older family's /mode/vs/0 has no top-level
# supportedModes at all (see the module docstring's Comode_Off finding).
# Both board generations share the /mode/vs/0 href, so FAN and MODE below
# are mutually exclusive via this presence check rather than colliding.
HREF_MODE = '/mode/vs/0'
HREF_AIRFLOW = '/airflow/0'
HREF_WIND_STRENGTH = '/wind/strength/vs/0'
def _has_top_level_modes(rep, resources):
return isinstance(rep.get('x.com.samsung.da.supportedModes'), (list, tuple))
_AIR_QUALITY_SENSORS = (
('dust', 'Dust', 'mdi:blur', 'Dust'),
('fine_dust', 'Fine dust', 'mdi:blur', 'FineDust'),
('super_fine_dust', 'Super fine dust', 'mdi:blur', 'SuperFineDust'),
('odor', 'Odor', 'mdi:scent', 'Odor'),
('clean_level', 'Clean level', 'mdi:air-filter', 'CleanLevel'),
('dust', 'mdi:blur', 'Dust'),
('fine_dust', 'mdi:blur', 'FineDust'),
('super_fine_dust', 'mdi:blur', 'SuperFineDust'),
('odor', 'mdi:scent', 'Odor'),
('clean_level', 'mdi:air-filter', 'CleanLevel'),
)
AIR_QUALITY = Capability(
href='/sensors/vs/0',
poll_tier='warm',
entities=tuple(
SensorDesc(key=key, field='x.com.samsung.da.items', name=name, icon=icon,
SensorDesc(key=key, field='x.com.samsung.da.items', icon=icon,
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t))
for key, name, icon, sensor_type in _AIR_QUALITY_SENSORS
for key, icon, sensor_type in _AIR_QUALITY_SENSORS
),
)
@@ -85,7 +119,7 @@ FILTER = Capability(
poll_tier='cold',
entities=(
SensorDesc(key='filter_progress', field='x.com.samsung.da.items',
name='Filter progress', unit='%', state_class='measurement',
unit='%', state_class='measurement',
icon='mdi:air-filter', entity_category='diagnostic',
value_fn=lambda items: int_or_none(
_consumable_state(items, 'FilterProgress'))),
@@ -97,38 +131,77 @@ DEVICE_ACTIVE = Capability(
poll_tier='cold',
entities=(
BinarySensorDesc(key='device_active', field='x.com.samsung.da.deviceActive',
name='Device active', icon='mdi:check-network-outline',
icon='mdi:check-network-outline',
entity_category='diagnostic',
value_fn=lambda v: bool(v)),
),
)
# OCF-native / vendor pair for fan speed+direction -- see module docstring for
# why these are read-only for now.
def _power_write(power_href, value):
"""Shared 'power' payload handling for this family's three FanDesc write
functions -- targets whichever power href fan.py's _power_payload picked
(the board may only report /power/0); a hardcoded vendor href here would
silently no-op on such a board even though the entity's own is_on
already falls back to reading it correctly."""
if power_href == '/power/0':
return ['power', '0'], {'value': bool(value)}
return (['power', 'vs', '0'],
{'x.com.samsung.da.power': 'On' if value else 'Off'})
def _airflow_fan_write(payload, rep, href=None):
kind, value, *args = payload
if kind == 'power':
return _power_write(args[0] if args else '/power/vs/0', value)
if kind == 'speed':
return ['airflow', '0'], {'speed': int(value)}
return None
# Confirmed via issue #56's second, properly-spaced round of diagnostics
# (two independent units, 60-90s apart per setting): /airflow/0's `speed` is
# a clean, monotonic 0-4 code across Auto/Sleep/Low/Medium/High, so it now
# backs a real ordered-speed fan (fan.py's LocalThingsAirflowFan, same
# SET_SPEED shape as the range hood's) instead of a read-only sensor --
# no named-preset table needed, since HA's percentage steps map onto the
# raw 0-4 code directly, the same way the range hood's numeric levels do.
# `direction` stays a plain diagnostic: every dump seen (both rounds, both
# units) reads 'Off' for it regardless of fan setting, so there's nothing
# confirmed to control there yet.
#
# Keyed 'airflow_fan', not 'fan' -- FAN below (bound to the shared
# /mode/vs/0 href) also uses 'fan', and BoundEntity's unique_id is built
# from key alone (entity.py's _key), not href. FAN and AIRFLOW_GENERIC are
# only *empirically* mutually exclusive (every dump seen has one board
# generation's shape or the other, never both), not architecturally
# enforced the way same-href caps are by _build()'s match_fn check -- a
# same key would collide if a future board ever reported both.
AIRFLOW_GENERIC = Capability(
href='/airflow/0',
href=HREF_AIRFLOW,
poll_tier='warm',
entities=(
SensorDesc(key='fan_speed_level', field='speed',
name='Fan speed level', icon='mdi:fan',
state_class='measurement', entity_category='diagnostic'),
FanDesc(key='airflow_fan', field='speed', write_fn=_airflow_fan_write),
SensorDesc(key='fan_direction', field='direction',
name='Fan direction', icon='mdi:rotate-3d-variant',
icon='mdi:rotate-3d-variant',
entity_category='diagnostic'),
),
)
# Left exactly as a read-only fallback -- speedLevel is NOT the same
# confirmed-reliable field as /airflow/0's speed above (see module
# docstring): it collided Low/Medium on one unit and stuck at 0 throughout
# on the other in the same properly-spaced round.
AIRFLOW_VS_FALLBACK = Capability(
href='/airflow/vs/0',
match_fn=lambda rep, resources: '/airflow/0' not in resources,
poll_tier='warm',
entities=(
SensorDesc(key='fan_speed_level', field='x.com.samsung.da.speedLevel',
name='Fan speed level', icon='mdi:fan',
icon='mdi:fan',
state_class='measurement', entity_category='diagnostic',
value_fn=int_or_none),
SensorDesc(key='fan_direction', field='x.com.samsung.da.direction',
name='Fan direction', icon='mdi:rotate-3d-variant',
icon='mdi:rotate-3d-variant',
entity_category='diagnostic'),
),
)
@@ -149,26 +222,244 @@ def _light_write(payload, rep, href=None):
MODE = Capability(
href='/mode/vs/0',
poll_tier='warm',
match_fn=lambda rep, resources: not _has_top_level_modes(rep, resources),
entities=(
SwitchDesc(key='display_light', name='Display light', icon='mdi:led-on',
SwitchDesc(key='display_light', icon='mdi:led-on',
entity_category='config',
rep_fn=bool_option_value('Light'),
exists_fn=bool_option_exists('Light'),
write_fn=_light_write),
# Read-only -- confirmed NOT the fan-speed selector (see module
# docstring), actual purpose still unconfirmed.
SensorDesc(key='operating_mode', name='Operating mode', icon='mdi:fan',
SensorDesc(key='operating_mode', icon='mdi:fan',
entity_category='diagnostic',
rep_fn=lambda rep: option_value(rep.get('x.com.samsung.da.options'), 'Comode'),
exists_fn=bool_option_exists('Comode')),
),
)
def _fan_write(payload, rep, href=None):
kind, value, *args = payload
if kind == 'power':
return _power_write(args[0] if args else '/power/vs/0', value)
if kind == 'mode':
return ['mode', 'vs', '0'], {'x.com.samsung.da.modes': [value]}
return None
def _first_fan_mode(rep):
"""Representative scalar for the fan entity in the flattened state
(golden/regression), mirroring airconditioner.py's own _first_mode --
the real entity computes its state from live coordinator reads."""
modes = rep.get('x.com.samsung.da.modes')
if isinstance(modes, (list, tuple)):
return modes[0] if modes else None
return modes
# Named preset modes (Smart/Max/Mid/WindFree/Sleep), not an ordered
# percentage -- WindFree/Smart/Sleep are named behaviors, not
# "faster/slower" positions relative to Max/Mid, so fan.py's entity for
# this only exposes PRESET_MODE, matching how the AC family's own named
# convenient modes are modeled as a preset rather than a speed number.
FAN = Capability(
href=HREF_MODE,
poll_tier='warm',
match_fn=_has_top_level_modes,
entities=(
FanDesc(key='fan', translation_key='air_purifier_fan',
rep_fn=_first_fan_mode, write_fn=_fan_write),
),
)
def _wind_strength_fan_write(payload, rep, href=None):
kind, value, *args = payload
if kind == 'power':
return _power_write(args[0] if args else '/power/vs/0', value)
if kind == 'mode':
return ['wind', 'strength', 'vs', '0'], {'x.com.samsung.da.modes': value}
return None
# A-VTWW-TP2-21-COMMON (issue #151): named preset modes like FAN above, but
# on a distinct href with numeric codes ("87"/"89"/"90"/"91") instead of
# self-describing supportedModes -- x.com.samsung.da.modesName gives the
# actual names (SMART/MAX/WINDFREE/Sleep), read live by fan.py's
# LocalThingsAirPurifierFan._label_for_code rather than a hardcoded
# per-model map. modes here is a bare string ('87'), not a single-element
# list like HREF_MODE's -- _wind_strength_fan_write writes it back as-is.
#
# key is 'wind_strength_fan', NOT 'fan' -- FAN above shares this registry
# and also uses a FanDesc; BoundEntity's unique_id is built from key alone
# (entity.py's _key), not href, so two same-key FanDescs in one registry
# would collide if a board ever bound both (see AIRFLOW_GENERIC's own
# comment on this exact hazard -- missed here in the initial cut).
WIND_STRENGTH_FAN = Capability(
href=HREF_WIND_STRENGTH,
poll_tier='warm',
entities=(
FanDesc(key='wind_strength_fan', translation_key='air_purifier_fan',
field='x.com.samsung.da.modes', write_fn=_wind_strength_fan_write),
),
)
# ---------------------------------------------------------------------------
# TP1X_DA-AC-AIR-class additions (issue #130). This board reports several
# resources the older ARTIK051_TVTL family never did.
# ---------------------------------------------------------------------------
# Screen/indicator-panel on/off -- distinct from LIGHT below (ambient mood
# light): both report the same {mode, supportedModes: [On, Off]} shape on
# separate hrefs on this dump, so they're two independent physical controls,
# not a duplicate encoding of one.
DISPLAY = Capability(
href='/display/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='display', field='mode',
icon='mdi:monitor',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['display', 'vs', '0'],
{'mode': 'On' if p == 'On' else 'Off'})),
),
)
# Same filterUsage/filterCapacity/filterStatus shape as the AC family's own
# AIR_FILTER (airconditioner.py) -- confirmed normal/wash/replace values not
# seen on this one dump, so the option list there is reused as-is rather
# than re-deriving it from a single sample.
HEPA_FILTER = Capability(
href='/filter/hepafilter/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='hepa_filter_usage', rep_fn=filter_usage_percent,
unit='%', state_class='measurement',
icon='mdi:air-filter', entity_category='diagnostic'),
SensorDesc(key='hepa_filter_status', field='x.com.samsung.da.filterStatus',
device_class='enum',
options=('normal', 'wash', 'replace'),
translation_key='filter_status',
icon='mdi:air-filter', entity_category='diagnostic',
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
),
)
# Physical panel/cover status -- meaning of the one value seen ('Close') is
# plausible (the HEPA-filter access cover) but unconfirmed, and no
# supportedStatus list is present to check against -- exposed as a plain
# diagnostic sensor rather than an asserted binary_sensor polarity.
PANEL_STATUS = Capability(
href='/panel/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='panel_status', field='status',
icon='mdi:archive-outline', entity_category='diagnostic'),
),
)
# Pet-care filter mode -- a plain On/Off field with no vendor prefix, same
# convention as airconditioner.MUTE_ONCE.
PET_FILTER_ACTIVATION = Capability(
href='/petfilteractivation/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='pet_filter_activation', field='status',
icon='mdi:paw',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['petfilteractivation', 'vs', '0'],
{'status': 'On' if p == 'On' else 'Off'})),
),
)
# Sound mode/volume shapes look like laundry.py's SOUND_MODE/SOUND_VOLUME at
# a glance, but this board's actual values differ (supportedModes here is
# ['mute', 'buzzer'], not laundry's hardcoded voice/tone/mute; volume range
# is 0-3, not laundry's fixed 0-15) -- reusing those would either reject a
# valid write ('buzzer') or expose the wrong number range, so these are
# separate descriptors reading the live supported values instead of a
# hardcoded table.
SOUND_MODE = Capability(
href='/settings/sound/mode/vs/0',
poll_tier='cold',
entities=(
# Distinct translation_key from laundry.SOUND_MODE's shared
# 'sound_mode' catalog entry -- that one's state table is
# {voice, tone, mute}, but this board's supportedModes is
# {mute, buzzer}. Sharing the key would leave 'buzzer' unlabelled
# (falls through to the raw code) since the catalogs don't overlap.
SelectDesc(key='sound_mode', translation_key='air_purifier_sound_mode',
field='mode',
icon='mdi:volume-high',
entity_category='config',
options_field='supportedModes',
write_fn=lambda p, rep, href=None: (
['settings', 'sound', 'mode', 'vs', '0'], {'mode': p})),
),
)
# Read-only descriptor of which sound output the unit has -- only one value
# seen, no alternatives to select between.
SOUND_OUTPUT = Capability(
href='/settings/sound/output/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='sound_output', field='deviceType',
icon='mdi:volume-high', entity_category='diagnostic'),
),
)
SOUND_VOLUME = Capability(
href='/settings/sound/volume/vs/0',
poll_tier='cold',
entities=(
NumberDesc(key='sound_volume', field='level',
icon='mdi:volume-medium',
entity_category='config',
native_min_fn=lambda rep: int_or_none(rep.get('minLevel')) or 0,
native_max_fn=lambda rep: int_or_none(rep.get('maxLevel')) or 0,
step_fn=lambda rep: int_or_none(rep.get('resolution')) or 1,
value_fn=int_or_none,
write_fn=lambda p, rep, href=None: (
['settings', 'sound', 'volume', 'vs', '0'],
{'level': str(int(p))})),
),
)
# /humidity/0 and /humidity/vs/0 are empty {} on both dumps this family has
# been verified against -- covered here (not globally, per ignored.py's
# module docstring) since those hrefs collide with fridge/AC schemas
# elsewhere. Same two hrefs and reasoning as airconditioner.py's _AC_IGNORED.
#
# The next six hrefs (issue #130, TP1X_DA-AC-AIR board) are the exact same
# resources, same shapes, same reasoning as airconditioner.py's
# _AC_IGNORED on the shared DA-AC- board family -- duplicated here rather
# than promoted to the global ignored.py list, since that would require
# also removing them from _AC_IGNORED in the same change (a global entry
# colliding with a family-local bare Capability on the same href raises in
# _build()); left as a possible follow-up DRY cleanup.
COVERAGE = [
Capability(href='/humidity/0'),
Capability(href='/humidity/vs/0'),
Capability(href='/airlevelcheck/vs/0'), # periodic air-quality sensing scheduler plumbing
Capability(href='/availablecontrolsets/vs/0'), # opaque hex-encoded control-set bitmap
Capability(href='/da/softreset/vs/0'), # soft-reset trigger plumbing
Capability(href='/keepnormalstate/vs/0'), # internal keep-normal flag
Capability(href='/personality/presence/vs/0'), # presence-personalization plumbing (empty here)
Capability(href='/reserverulesets/vs/0'), # opaque hex-encoded schedule reservation blob
# Do-not-disturb/auto-sleep schedule (visible/startTime/endTime/
# useTimeSetting/functionState) -- every field reads its inert default
# on the only dump seen (times both '00:00:00', useTimeSetting/
# functionState both 'false'). Same "needs a multi-field schedule
# editor" treatment as fridge.py's /defrost/reservation/vs/0.
Capability(href='/dnd/autosleep/vs/0'),
# Empty ({}) on the A-VTWW-TP2-21 dump (issue #151) -- this board's
# convenient-mode-equivalent behavior lives entirely in WIND_STRENGTH_FAN
# above instead.
Capability(href='/mode/convenient/vs/0'),
]
@@ -15,7 +15,141 @@ different schema (see capabilities/__init__.py). They live only in the AC
by_type registry.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
from ..entities import (
BinarySensorDesc, ClimateDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc,
)
from .common import filter_usage_percent, normalize_temp_unit
from .laundry import option_write
def _int(v):
try:
return int(v)
except (TypeError, ValueError):
return None
def _beep_on(rep):
"""Beep on/off from the `Volume_*` option token: Volume_Mute = off,
Volume_100 (and any non-Mute) = on. None when no Volume_ slot.
_option_token (defined further below, alongside the legacy-board token
helpers) returns the token's *value* half (e.g. 'Mute', '100'), not the
full 'Volume_100' token -- shared with _option_token_num/_option_token_on,
which this module's other options[] readers already rely on.
"""
tok = _option_token(rep, 'Volume')
if tok is None:
return None
return tok != 'Mute'
def _beep_write(payload, rep, href=None):
"""Toggle beep via a single-token /mode/vs/0 options write (option_write's
one-token merge -- a full options RMW reverts on ARTIK051_PRAC). 'On'
restores the last non-Mute level rather than forcing Volume_100, so a
user's intermediate setting (e.g. Volume_50 set via the cloud) survives an
off/on cycle; falls back to 100 when no prior level is known."""
if payload not in ('On', 'Off'):
return None
if payload == 'Off':
token = 'Mute'
else:
prev = _option_token(rep, 'Volume')
token = prev if (prev and prev != 'Mute') else '100'
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': option_write('Volume', token),
}
def _tropical_night_value(rep):
"""Tropical night mode level (0-16) from the `Sleep_<N>` option token.
_option_token returns the token's value half already (e.g. '16' for
'Sleep_16'), same convention as _beep_on above.
"""
tok = _option_token(rep, 'Sleep')
if tok is None:
return None
return _int(tok)
def _tropical_night_write(value, rep, href=None):
"""Set tropical night level via a single-token `Sleep_<N>` options write.
Samsung cloud counterpart: custom.airConditionerTropicalNightMode (0-16)."""
try:
level = int(round(float(value)))
except (TypeError, ValueError):
return None
if not 0 <= level <= 16:
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': option_write('Sleep', str(level)),
}
def _filter_unit(rep):
"""Unit of the filter-usage fields, normalised from filterCapacityUnit
('Hour' -> 'h'). Wired through unit_fn so a board advertising a different
unit doesn't silently mislabel a duration statistic."""
u = rep.get('x.com.samsung.da.filterCapacityUnit')
return {'Hour': 'h', 'Minute': 'min', 'Second': 's'}.get(u, u or 'h')
def _threshold_write(payload, rep, href=None):
"""filterDesiredUsage is locally writable: a plain scalar POST of the
field to /filter/airdustfilter/vs/0 is 2.04-accepted and persists
(confirmed live on ARTIK051_PRAC: POST 700 -> 2.04, read-back 700). The
Select only surfaces where the device advertises
supportedFilterDesiredUsage, so the valid options are known rather than
guessed; boards without that enum leave this writable field unexposed."""
return ['filter', 'airdustfilter', 'vs', '0'], {
'x.com.samsung.da.filterDesiredUsage': payload,
}
def _sensor_item_value(items, type_):
"""First value of the /sensors/vs/0 item with the given
x.com.samsung.da.type. The resource exposes no unit, so no device_class is
set until a populated reading + unit is observed (the 'don't guess' rule).
Dust/FineDust/SuperFineDust report a 2-element array (['0','0']) while
CleanLevel/Odor report a single element -- the second element's meaning is
unconfirmed, so v[0] is taken as the reading and v[1] is dropped; left as
a string rather than coerced numeric because only CleanLevel has
corroborating evidence (a top-level x.com.samsung.da.cleanLevel scalar)."""
for it in (items or []):
if isinstance(it, dict) and it.get('x.com.samsung.da.type') == type_:
v = it.get('x.com.samsung.da.value')
if isinstance(v, list) and v:
return str(v[0])
return None
return None
def _has_sensor_type(type_):
"""True when the /sensors/vs/0 items[] array lists an item of this type.
This proves the type is *listed*, not that the reading is real: issue
#166 (ARxxTXFCAWKNEU, board ARTIK051_PRAC_20K) lists all five item types
with permanent zero values on both its units, and the reporter confirmed
none of these sensors are physically present. A top-level
x.com.samsung.da.cleanLevel scalar (separate from the CleanLevel item)
looked like a corroborating "this reading is real" signal at first --
present alongside genuinely populated readings on tp1x_da_ac_rac_01011
and the tp1x_da_ac_air air purifier fixture, absent on every all-zero
ARTIK051_PRAC_20K dump including both #166 units -- but it doesn't hold
up as a general rule: air_purifier_device.json (ARTIK051_TVTL_18K),
air_purifier_vtww_device.json, and range_hood_device.json all carry
genuinely populated, non-AC-family Dust/FineDust/SuperFineDust readings
with no such scalar. So this stays item-type presence only -- the
entities are disabled by default instead (see AIR_QUALITY below) rather
than existence-gated on a signal that would silently drop real readings
on hardware this repo hasn't seen yet."""
def fn(rep, resources):
return any(isinstance(i, dict) and i.get('x.com.samsung.da.type') == type_
for i in (rep.get('x.com.samsung.da.items') or []))
return fn
# ---------------------------------------------------------------------------
# Canonical AC resource hrefs. The climate entity (climate.py) binds the
@@ -33,13 +167,26 @@ HREF_TEMP_DESIRED = '/temperature/desired/0' # target_temperature (write ta
HREF_TEMP_CONTROL = '/temperature/control/vs/0' # target_temperature_step
HREF_WIND_STRENGTH = '/wind/strength/vs/0' # fan_mode
HREF_WIND_DIRECTION = '/wind/direction/vs/0' # swing_mode
# Newer boards (issue #126, TP1X_DA-AC-RAC-01011 WindFree variant) report no
# HREF_WIND_DIRECTION at all and instead carry a 2-axis oscillation resource
# (separate vertical/horizontal Swing|Fix toggles, each with its own angle).
# climate.py falls back to this when HREF_WIND_DIRECTION is absent, the same
# duality pattern as the OCF/vendor temperature channel below.
HREF_WIND_OSCILLATION = '/wind/oscillation/vs/0' # swing_mode fallback
HREF_CONVENIENT = '/mode/convenient/vs/0' # preset_mode
HREF_TEMPS_VS = '/temperatures/vs/0' # vendor temp fallback (items[] array)
# Legacy ARTIK051 boards (ARTIK051_KRAC_18K, issue #136) carry no /wind/* resources
# at all: fan speed and vane direction sit together in this one resource, as
# x.com.samsung.da.speedLevel (the same 0-4 scale as _DEVICE_TO_FAN) and
# x.com.samsung.da.direction (the same codes as _DEVICE_TO_SWING). Their
# convenient-mode preset is a Comode_* token in /mode/vs/0's options instead of a
# resource of its own -- see climate.py's _legacy_airflow/_legacy_convenient.
HREF_AIRFLOW = '/airflow/vs/0' # legacy fan_mode + swing_mode
CLIMATE_CONSUMED_HREFS = [
HREF_POWER, HREF_POWER_VS, HREF_TEMP_CURRENT, HREF_TEMP_DESIRED,
HREF_TEMP_CONTROL, HREF_TEMPS_VS, HREF_WIND_STRENGTH, HREF_WIND_DIRECTION,
HREF_CONVENIENT,
HREF_WIND_OSCILLATION, HREF_CONVENIENT, HREF_AIRFLOW,
]
@@ -50,16 +197,23 @@ def _num(v):
return None
def _filter_usage_percent(rep):
"""Filter usage as a percentage of rated capacity. The device reports
`filterUsage` as a raw count in `filterCapacityUnit` (Hours here, e.g.
100 of a 500 capacity), so a plain value with a '%' unit would be wrong --
normalize to used/capacity. Returns None when capacity is missing/zero."""
used = _num(rep.get('x.com.samsung.da.filterUsage'))
cap = _num(rep.get('x.com.samsung.da.filterCapacity'))
if used is None or not cap:
return None
return round(used / cap * 100)
def _temps_vs_item(rep):
"""First item of the vendor `/temperatures/vs/0` items[] array -- the
Tizen Lite board's only current-temperature source (see climate.py's
identical helper; duplicated rather than imported to avoid a
capabilities<->platform import cycle)."""
items = rep.get('x.com.samsung.da.items')
if isinstance(items, (list, tuple)) and items and isinstance(items[0], dict):
return items[0]
return {}
def _temps_vs_current(rep):
return _num(_temps_vs_item(rep).get('x.com.samsung.da.current'))
def _temps_vs_unit(rep):
return normalize_temp_unit(_temps_vs_item(rep).get('x.com.samsung.da.unit'), '°C')
def _first_mode(rep):
@@ -71,25 +225,200 @@ def _first_mode(rep):
return modes
def _mode_options(rep):
opts = rep.get('x.com.samsung.da.options')
return opts if isinstance(opts, (list, tuple)) else ()
def _has_display_light_option(rep, resources):
"""True when the panel light state is carried inside /mode/vs/0's options
blob (a `Light_On`/`Light_Off` token) rather than a dedicated /light/vs/0
switch. The two encodings are mutually exclusive across observed boards:
models exposing the /light/vs/0 switch (bound by DISPLAY_LIGHT below)
carry no Light_* option, so this entity only materialises on the boards
that would otherwise have no display-light entity at all."""
return any(isinstance(o, str) and o.startswith('Light_')
for o in _mode_options(rep))
def _display_light_on(rep):
"""Panel display light state from /mode/vs/0's options blob. The token is
INVERTED relative to its name -- confirmed by a live toggle test: with the
panel lit the option reads `Light_Off`, and with it dark it reads
`Light_On` (the flag really encodes "night/display-off mode active"). So
`Light_Off` -> light on, `Light_On` -> light off. Read-only from here; the
write below uses the device's own single-token merge (see option_write)."""
for o in _mode_options(rep):
if isinstance(o, str) and o.startswith('Light_'):
return o == 'Light_Off'
return None
def _display_light_write(payload, rep, href=None):
"""Toggle the panel light via a single-token /mode/vs/0 options write
('SingleCommand_1' is advertised in this family's /configuration/vs/0
airconOptionList; option_write's one-token merge is the same mechanism
air_purifier.py uses for its own Light switch). Polarity is inverted (see
_display_light_on): switching the lamp ON writes 'Light_Off', OFF writes
'Light_On'."""
token = 'Off' if payload == 'On' else 'On'
return (['mode', 'vs', '0'],
{'x.com.samsung.da.options': option_write('Light', token)})
# ---------------------------------------------------------------------------
# Legacy ARTIK051 boards keep several settings that newer boards expose as their
# own resources (/option/*, /electriccurrent/vs/0, ...) as `<Prefix>_<value>`
# tokens inside /mode/vs/0's options blob instead. Reads pull the token apart;
# writes reuse option_write's single-token merge, exactly like the display light.
# ---------------------------------------------------------------------------
def _option_token(rep, prefix):
"""Value part of a `<prefix>_<value>` token in /mode/vs/0's options."""
for option in _mode_options(rep):
if isinstance(option, str) and option.startswith(prefix + '_'):
return option.split('_', 1)[1]
return None
def is_legacy_board(resources):
"""True for the board generation whose airflow lives in /airflow/vs/0.
Newer families carry several of the same option tokens (Volume, Sleep,
OutdoorTemp, Autoclean) *alongside* dedicated resources for those settings,
so an ungated token entity would either duplicate an existing one or apply a
scale calibrated elsewhere. Every AC dump on record has one shape or the
other: /airflow/vs/0 with no /wind/* at all, or /wind/strength/vs/0 with no
/airflow/vs/0. Same test as climate.py's _legacy_airflow(), so the entities
below and the climate entity can never disagree about the generation.
"""
return HREF_AIRFLOW in resources and HREF_WIND_STRENGTH not in resources
def _has_option_token(prefix):
return lambda rep, resources: (
is_legacy_board(resources) and _option_token(rep, prefix) is not None)
def _option_token_on(prefix):
return lambda rep: _option_token(rep, prefix) == 'On'
def _option_token_num(prefix, offset=0, divisor=1):
def read(rep):
raw = _option_token(rep, prefix)
try:
return (float(raw) - offset) / divisor
except (TypeError, ValueError):
return None
return read
def _option_switch_write(prefix):
def write(payload, rep, href=None):
return (['mode', 'vs', '0'],
{'x.com.samsung.da.options': option_write(prefix, payload)})
return write
def _option_number_write(prefix):
def write(payload, rep, href=None):
return (['mode', 'vs', '0'],
{'x.com.samsung.da.options':
option_write(prefix, str(int(round(float(payload)))))})
return write
def _humidity(rep):
"""Relative humidity, preferring the 5%-rounded field where it exists.
ARTIK051 boards have no fivepercentHumidity field at all and report the
plain x.com.samsung.da.humidity instead -- and only populate it while the
Air monitoring option is on: the unit measures for roughly half a minute
(51% observed, matching what the same unit's cloud integration reported at
that moment), then zeroes the field and switches Air monitoring back off by
itself. So 0 reads as "not measuring" and is reported as unknown rather than
as 0% humidity, which would poison long-term history.
That zero-as-"not measuring" carve-out is specific to the ARTIK051
fallback field's hardware quirk -- every other board's fivepercentHumidity
has never been documented getting stuck at zero, and collapsing a
genuine 0% reading there to unknown is a regression, not a safeguard
(issue #160). So fivepercentHumidity passes 0 through unchanged; only the
humidity fallback applies the zero-collapse.
"""
if 'x.com.samsung.da.fivepercentHumidity' in rep:
return _num(rep['x.com.samsung.da.fivepercentHumidity'])
if 'x.com.samsung.da.humidity' in rep:
value = _num(rep['x.com.samsung.da.humidity'])
return value if value else None
return None
def _climate_write(payload, rep, href=None):
"""Map a (kind, value) command from the climate platform to the
(path_segs, body) for that one sub-write. `value` is already the raw device
code (the platform maps HA<->device). async_send_command POSTs to path_segs,
so a single desc drives writes across power/mode/temperature/wind resources.
Read-modify-write safe: each write sends only its own field, leaving the
resource's other fields (e.g. /mode/vs/0's opaque `options` blob) untouched.
so a single desc drives writes across the power/mode/temperature/wind
resources.
Power goes to the vendor `/power/vs/0` (the OCF `/power/0` is absent on
most boards and a non-authoritative mirror where present -- vendor works
on every board). Temperature is board-dependent, so the platform picks the
channel and sends `temperature_ocf` (-> OCF `/temperature/desired/0`,
boards with the full OCF current+desired pair) or `temperature` (-> vendor
`/temperatures/vs/0`, boards without it). Mode/fan/swing/preset are always
the vendor `/x/vs/0` resources.
Each write sends only its own field(s), leaving the resource's other
fields (e.g. /mode/vs/0's opaque `options` blob, or the vendor temperature
item's current/minimum/maximum/unit) untouched -- the device merges the
rest itself, same contract as the options[] array (see
common.merge_items_field / merge_options_field, which keep the
coordinator's optimistic cache complete for the settle window instead of
this write echoing those fields back).
"""
kind, value = payload
if kind == 'power':
return (['power', '0'], {'value': bool(value)})
return (['power', 'vs', '0'],
{'x.com.samsung.da.power': 'On' if value else 'Off'})
if kind == 'mode':
return (['mode', 'vs', '0'], {'x.com.samsung.da.modes': [value]})
if kind == 'temperature_ocf':
return (['temperature', 'desired', '0'],
{'temperature': int(round(float(value)))})
if kind == 'temperature':
return (['temperature', 'desired', '0'], {'temperature': int(round(float(value)))})
# Vendor items[] array; only one item observed on every AC dump, id
# '0'. See the docstring above for why this doesn't echo current/
# minimum/maximum/unit back at the unit.
return (['temperatures', 'vs', '0'],
{'x.com.samsung.da.items': [
{'x.com.samsung.da.id': '0',
'x.com.samsung.da.desired': str(int(round(float(value))))}]})
if kind == 'fan':
return (['wind', 'strength', 'vs', '0'], {'x.com.samsung.da.modes': value})
if kind == 'swing':
return (['wind', 'direction', 'vs', '0'], {'x.com.samsung.da.modes': value})
if kind == 'oscillation':
# value is the HA swing_mode string ('off'/'vertical'/'horizontal'/
# 'both'); both axes are independent Swing|Fix toggles on this
# resource, so one HA value maps to a pair of fields written
# together (see climate.py's oscillation fallback).
return (['wind', 'oscillation', 'vs', '0'], {
'vertical': 'Swing' if value in ('vertical', 'both') else 'Fix',
'horizontal': 'Swing' if value in ('horizontal', 'both') else 'Fix',
})
if kind == 'fan_legacy':
return (['airflow', 'vs', '0'],
{'x.com.samsung.da.speedLevel': str(value)})
if kind == 'swing_legacy':
return (['airflow', 'vs', '0'],
{'x.com.samsung.da.direction': value})
if kind == 'preset_legacy':
# Single-token options merge, same mechanism as _display_light_write.
return (['mode', 'vs', '0'],
{'x.com.samsung.da.options': option_write('Comode', value)})
if kind == 'preset':
return (['mode', 'convenient', 'vs', '0'], {'x.com.samsung.da.modes': value})
return None
@@ -101,6 +430,108 @@ CLIMATE = Capability(
entities=(
ClimateDesc(key='climate', translation_key='airconditioner',
rep_fn=_first_mode, write_fn=_climate_write),
# Display (panel) light switch, only on boards that encode it in
# /mode/vs/0's options instead of a /light/vs/0 switch (see
# _has_display_light_option). Shares the /mode/vs/0 href with the
# climate entity above -- same Capability, so no multi-cap
# discriminator is needed. /mode/vs/0 is OBSERVE-subscribed, so state
# updates on push; writes go through the single-token merge in
# _display_light_write. Shares the switch.display_light translation
# with DISPLAY_LIGHT (the /light/vs/0 switch on other boards) --
# mutually exclusive per href, so only one ever binds for a given unit.
SwitchDesc(key='display_light', rep_fn=_display_light_on,
exists_fn=_has_display_light_option,
write_fn=_display_light_write,
icon='mdi:led-on', entity_category='config'),
# Beep on/off from the `Volume_*` option token (Volume_Mute/Volume_100).
# Single-token option_write; a full options RMW reverts on ARTIK051_PRAC.
# Gated off the legacy ARTIK051 board generation (see is_legacy_board):
# that generation's own Volume_ token is already modeled as the
# buzzer_volume Number below, and both reading the same options[] slot
# into two entities would be redundant.
SwitchDesc(key='beep', rep_fn=_beep_on,
exists_fn=lambda rep, resources: (
not is_legacy_board(resources)
and _option_token(rep, 'Volume') is not None),
write_fn=_beep_write,
icon='mdi:volume-high', entity_category='config'),
# Tropical night mode level (0-16) from the `Sleep_<N>` option token.
# Single-token option_write. Cloud: custom.airConditionerTropicalNightMode.
# Gated off the legacy board for the same reason as beep above -- its
# Sleep_ token is already the good_sleep Number below.
#
# exists_fn only proves the Sleep_ token slot is present, not that
# tropical night mode is a real feature of the unit: issue #166
# (ARxxTXFCAWKNEU) reports Sleep_0 in every dump -- the exact same
# always-there-at-zero shape as the issue #17 dump #164 was verified
# against -- yet the reporter confirmed their remote/app has no
# tropical night mode control at all. Samsung's OCF options[] blob
# carries this scaffolding token regardless of physical capability,
# so there's no reliable signal here to gate on (same 'don't guess'
# rule as elsewhere in this file, just with no signal to guess from).
# Registered but disabled by default, same precedent as
# fridge.rack_count / cooktop.paired_hood_* -- units that do have the
# feature can enable it themselves.
NumberDesc(key='tropical_night_mode', rep_fn=_tropical_night_value,
exists_fn=lambda rep, resources: (
not is_legacy_board(resources)
and _option_token(rep, 'Sleep') is not None),
write_fn=_tropical_night_write,
native_min=0, native_max=16, step=1,
enabled_default=False,
icon='mdi:weather-night', entity_category='config'),
# Settings that this board generation keeps as options[] tokens.
SwitchDesc(key='spi', rep_fn=_option_token_on('Spi'),
exists_fn=_has_option_token('Spi'),
write_fn=_option_switch_write('Spi'),
icon='mdi:air-purifier', entity_category='config'),
# Shares AUTO_CLEAN's catalog entry rather than duplicating it: same
# feature, different board generation (that one is a /option/autoclean/
# vs/0 field, absent here). Distinct key, so nothing collides if some
# future board ever reported both.
SwitchDesc(key='auto_clean_legacy', translation_key='auto_clean',
rep_fn=_option_token_on('Autoclean'),
exists_fn=_has_option_token('Autoclean'),
write_fn=_option_switch_write('Autoclean'),
icon='mdi:fan-auto', entity_category='config'),
SwitchDesc(key='air_monitoring', rep_fn=_option_token_on('AirMonitoring'),
exists_fn=_has_option_token('AirMonitoring'),
write_fn=_option_switch_write('AirMonitoring'),
icon='mdi:air-filter', entity_category='config'),
NumberDesc(key='buzzer_volume', rep_fn=_option_token_num('Volume'),
exists_fn=_has_option_token('Volume'),
write_fn=_option_number_write('Volume'),
native_min=0, native_max=100, step=10,
icon='mdi:volume-high', entity_category='config'),
# "Good Sleep" timer. 0 = off; the upper bound is a guess (the token
# carries no range hint and only 0 has been observed on hardware), so a
# write above 0 is unverified.
NumberDesc(key='good_sleep', rep_fn=_option_token_num('Sleep'),
exists_fn=_has_option_token('Sleep'),
write_fn=_option_number_write('Sleep'),
native_min=0, native_max=12, step=1, unit='h',
icon='mdi:sleep', entity_category='config'),
# Outdoor temperature, offset by 55. Two calibration points on one unit:
# token 75 while an independent outdoor thermometer in the same install
# read 20.3 C, and token 74 against a 19.4 C forecast. Fahrenheit fits far
# worse (74 F = 23.3 C); the issue #136 unit's 81 gives 26 C in a warmer
# climate, which is also plausible.
SensorDesc(key='outdoor_temperature',
rep_fn=_option_token_num('OutdoorTemp', offset=55),
exists_fn=_has_option_token('OutdoorTemp'),
device_class='temperature', state_class='measurement',
unit='°C', icon='mdi:home-thermometer-outline'),
# Filter time in tenths of an hour: the token read 1710 while the official
# Samsung app displayed "171 hours 0 minutes" for the filter on the same
# unit, and the .0 matching the app's "0 minutes" pins the scale. Whether
# it counts up or down is NOT established -- it was seen rising (171.0 ->
# 171.5) while the unit ran, which contradicts the app's "remaining"
# wording, so the entity is deliberately named neutrally.
SensorDesc(key='filter_time',
rep_fn=_option_token_num('FilterTime', divisor=10),
exists_fn=_has_option_token('FilterTime'),
device_class='duration', unit='h',
state_class='measurement', icon='mdi:air-filter'),
),
)
@@ -109,7 +540,7 @@ AIR_PURIFY = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='air_purify', field='x.com.samsung.da.modes',
name='Air purification', icon='mdi:air-purifier',
icon='mdi:air-purifier',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
@@ -123,7 +554,7 @@ AUTO_CLEAN = Capability(
poll_tier='cold',
entities=(
SwitchDesc(key='auto_clean', field='x.com.samsung.da.settingStatus',
name='Auto clean', icon='mdi:spray-bottle',
icon='mdi:spray-bottle',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
@@ -136,13 +567,35 @@ AIR_FILTER = Capability(
href='/filter/airdustfilter/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='air_filter_usage', rep_fn=_filter_usage_percent,
name='Filter usage', unit='%', state_class='measurement',
SensorDesc(key='air_filter_usage', rep_fn=filter_usage_percent,
unit='%', state_class='measurement',
icon='mdi:air-filter', entity_category='diagnostic'),
# filterUsage is a lifetime hour counter that only resets on filter
# replacement -- total_increasing so HA's long-term statistics handle
# the reset rather than treating it as a bounded measurement.
SensorDesc(key='air_filter_usage_hours',
field='x.com.samsung.da.filterUsage',
device_class='duration',
state_class='total_increasing',
unit_fn=_filter_unit,
icon='mdi:air-filter', entity_category='diagnostic',
value_fn=_int),
# The alarm threshold (filterDesiredUsage) is a locally writable option:
# see _threshold_write. Surfaces as a Select only where the device
# advertises supportedFilterDesiredUsage; boards without that enum
# leave it unexposed rather than guess the valid set.
SelectDesc(key='air_filter_threshold',
field='x.com.samsung.da.filterDesiredUsage',
options_field='x.com.samsung.da.supportedFilterDesiredUsage',
exists_fn=lambda rep, res: bool(
rep.get('x.com.samsung.da.supportedFilterDesiredUsage')),
icon='mdi:alarm', entity_category='config',
write_fn=_threshold_write,
value_fn=lambda v: str(v) if v is not None else None),
SensorDesc(key='air_filter_status', field='x.com.samsung.da.filterStatus',
name='Filter status', device_class='enum',
device_class='enum',
options=('normal', 'wash', 'replace'),
translation_key='air_filter_status',
translation_key='filter_status',
icon='mdi:air-filter', entity_category='diagnostic',
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
),
@@ -153,7 +606,7 @@ DISPLAY_LIGHT = Capability(
poll_tier='cold',
entities=(
SwitchDesc(key='display_light', field='mode',
name='Display light', icon='mdi:led-on',
icon='mdi:led-on',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
@@ -170,7 +623,7 @@ MUTE_ONCE = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='mute_once', field='muteonce',
name='Mute once', icon='mdi:volume-mute',
icon='mdi:volume-mute',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
@@ -190,15 +643,196 @@ CURRENT_LIMIT = Capability(
poll_tier='cold',
entities=(
BinarySensorDesc(key='current_limit_enabled', field='operation',
name='Current limit enabled', icon='mdi:current-ac',
icon='mdi:current-ac',
entity_category='diagnostic',
value_fn=lambda v: v == 'On'),
SensorDesc(key='current_limit_level', field='modes',
name='Current limit level', icon='mdi:current-ac',
icon='mdi:current-ac',
entity_category='diagnostic'),
),
)
# Overload-response setting (issue #126, TP1X_DA-AC-RAC-01011 WindFree
# variant): `operation` toggles the feature and `mode` picks 'Alarm' vs
# 'PowerSaving' out of `supportedModes`, with a `savingTime` duration
# ('20'/'40'/'60' minutes) alongside. Plausible shape (compressor-overload
# alarm vs. automatic power throttling), but nothing in the dump confirms
# the exact behavioral difference between the two modes or whether writing
# 'operation' is safe on live HVAC hardware -- exposed read-only per the
# 'don't guess' rule, same precedent as CURRENT_LIMIT above.
ANOMALY_LOAD = Capability(
href='/anomalyload/vs/0',
poll_tier='cold',
entities=(
BinarySensorDesc(key='overload_protection_active', field='operation',
icon='mdi:flash-alert',
entity_category='diagnostic',
value_fn=lambda v: v == 'On'),
SensorDesc(key='overload_protection_mode', field='mode',
device_class='enum',
options=('alarm', 'powersaving'),
translation_key='overload_protection_mode',
icon='mdi:flash-alert', entity_category='diagnostic',
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
),
)
# Absence-detection power-saving (issue #173, TP1X_LNX-AC-RAC-01001 --
# Lennox-branded heat pump on the RAC board family): `status` is a bare
# On/Off boolean with no vendor prefix, the same shape already shipped
# writable elsewhere in this file (MUTE_ONCE, AUTO_CLEAN, AIR_PURIFY,
# DISPLAY_LIGHT) despite none of those having a live-confirmed write either
# -- worst case a wrong token no-ops, same risk profile as that family, so
# it's a switch rather than a sensor. `switchPowerSaveMode` picks the save
# intensity out of its own supportedSwitchPowerSaveMode list, but *what*
# writing it actually does to a running compressor isn't knowable from the
# dump -- same 'don't guess' read-only treatment as CURRENT_LIMIT/
# ANOMALY_LOAD's mode fields. A third field, `motionState`, also carries a
# supportedMotionState list but its role (a live sensor readout vs. a
# sensitivity setting) isn't distinguishable from the dump, so it's left
# unmodeled entirely.
ABSENCE_POWER_SAVING = Capability(
href='/mds/absencepowersaving/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='absence_power_saving_active', field='status',
icon='mdi:human-greeting-proximity',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['mds', 'absencepowersaving', 'vs', '0'],
{'status': 'On' if p == 'On' else 'Off'})),
SensorDesc(key='absence_power_saving_mode', field='switchPowerSaveMode',
device_class='enum',
options=('eco', 'normal', 'comfort'),
translation_key='absence_power_saving_mode',
icon='mdi:leaf', entity_category='diagnostic',
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
),
)
# Avoid-direct-wind-on-motion, a sibling AI feature to ABSENCE_POWER_SAVING
# above on the same dump: `status` is the same bare On/Off shape, promoted to
# a switch for the same reason. `modes` (Direct/Indirect airflow out of
# `supportedModes`) stays read-only -- same reasoning as
# absence_power_saving_mode above.
MOTION_DETECT_WIND = Capability(
href='/option/motiondetectwind/stateful/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='motion_detect_wind_active', field='status',
icon='mdi:motion-sensor',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['option', 'motiondetectwind', 'stateful', 'vs', '0'],
{'status': 'On' if p == 'On' else 'Off'})),
SensorDesc(key='motion_detect_wind_mode', field='modes',
device_class='enum',
options=('direct', 'indirect'),
translation_key='motion_detect_wind_mode',
icon='mdi:weather-windy', entity_category='diagnostic',
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
),
)
# The climate entity already surfaces current_temperature as a card
# attribute, but that's not enough for history graphs/automations/
# statistics -- issue #75 asked for a standalone sensor. Same OCF-standard-
# with-vendor-fallback shape as common.py's POWER_GENERIC/POWER_VS_FALLBACK
# pair: both share key='current_temperature_c' so only one ever binds
# (match_fn gates the vendor one off when the OCF resource is present).
CURRENT_TEMPERATURE = Capability(
href=HREF_TEMP_CURRENT,
poll_tier='warm',
entities=(
SensorDesc(key='current_temperature_c', field='temperature',
device_class='temperature', state_class='measurement',
unit_fn=lambda rep: normalize_temp_unit(rep.get('units'), '°C')),
),
)
CURRENT_TEMPERATURE_VS = Capability(
href=HREF_TEMPS_VS,
poll_tier='warm',
match_fn=lambda rep, resources: HREF_TEMP_CURRENT not in resources,
entities=(
SensorDesc(key='current_temperature_c', rep_fn=_temps_vs_current,
device_class='temperature', state_class='measurement',
unit_fn=_temps_vs_unit),
),
)
# Only the vendor resource's `fivepercentHumidity` (current reading, rounded
# to the nearest 5%) has live data on the issue #75 dump -- its `humidity`
# field, and the OCF-standard /humidity/0 resource entirely, both read a
# stuck "0" there, so /humidity/0 stays ignored per the 'don't guess' rule
# (see _AC_IGNORED below).
#
# ARTIK051 boards (issue #136) have no fivepercentHumidity field at all, and
# there the plain `humidity` field is not stuck: it carries a real reading
# (51%, matching the same unit's cloud integration at that moment) for as long
# as the Air monitoring option is on, which the unit itself switches back off
# after roughly a minute -- so most dumps catch it at 0. Hence _humidity's
# fallback, and hence 0 reading as "not measuring" rather than 0%: on both
# board generations a zero here means no measurement, never dry air.
# /humidity/0 stayed 0 throughout that same observation too.
HUMIDITY = Capability(
href='/humidity/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='humidity', rep_fn=_humidity,
device_class='humidity', state_class='measurement', unit='%'),
),
)
# /sensors/vs/0 items[] carry live air-quality readings. Removed from
# _AC_IGNORED below so AIR_QUALITY is the sole cap on the href. CleanLevel is
# corroborated as numeric by a top-level x.com.samsung.da.cleanLevel scalar
# (tp1x_da_ac_rac_01011 reports both as '1'), so it's a measurement; the others
# are 1- or 2-element arrays with no corroborating scalar, so they stay string
# diagnostics (see _sensor_item_value for the 2-element ambiguity and why only
# v[0] is taken). No unit is advertised on the resource, so no device_class.
#
# exists_fn (_has_sensor_type) only proves the item *type* is listed, not
# that the unit actually carries that sensor: issue #166 (ARxxTXFCAWKNEU,
# board ARTIK051_PRAC_20K) reports all five item types on both its units,
# values permanently '0'/['0','0'] -- yet the reporter confirmed none apply
# to their model. A tighter existence gate was tried (requiring the
# corroborating cleanLevel scalar above) but doesn't hold up as a general
# rule -- see _has_sensor_type's docstring -- and risks silently dropping
# real readings on hardware that reports them without that scalar. So these
# stay bound whenever the type is listed, same as before #166, and disabled
# by default instead (same precedent as fridge.rack_count /
# cooktop.paired_hood_model / this file's own tropical_night_mode): units
# that do have the sensor can enable it themselves.
AIR_QUALITY = Capability(
href='/sensors/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='clean_level', field='x.com.samsung.da.items',
icon='mdi:broom', entity_category='diagnostic',
state_class='measurement',
exists_fn=_has_sensor_type('CleanLevel'),
enabled_default=False,
value_fn=lambda items: _int(_sensor_item_value(items, 'CleanLevel'))),
*tuple(
SensorDesc(key=key, field='x.com.samsung.da.items',
icon=icon, entity_category='diagnostic',
exists_fn=_has_sensor_type(type_),
enabled_default=False,
value_fn=lambda items, t=type_: _sensor_item_value(items, t))
for key, icon, type_ in (
('odor', 'mdi:weather-windy', 'Odor'),
('dust', 'mdi:cloud', 'Dust'),
('fine_dust', 'mdi:cloud-outline', 'FineDust'),
('super_fine_dust', 'mdi:weather-fog', 'SuperFineDust'),
)
),
),
)
# ---------------------------------------------------------------------------
# AC-scoped coverage: the CLIMATE_CONSUMED_HREFS above (read by the climate
# entity) plus vendor duplicates / all-zero-ambiguous / plumbing resources.
@@ -218,13 +852,18 @@ CURRENT_LIMIT = Capability(
# of waiting on the summary sweep.
# ---------------------------------------------------------------------------
_AC_IGNORED = [
# All-zero and ambiguously encoded on this model (2-value arrays); the
# 'don't guess' rule -- leave unmodeled rather than invent entities.
'/sensors/vs/0',
# Stuck at "0" on every dump seen -- HUMIDITY above reads the vendor
# resource's usable fivepercentHumidity field instead; this OCF-standard
# one has no corresponding live value confirmed yet.
'/humidity/0',
'/humidity/vs/0',
# Presence-personalization plumbing (empty item list here).
'/personality/presence/vs/0',
# OCF-standard mirror of /airflow/vs/0 ({speed, direction} vs
# {speedLevel, direction}, identical values). The climate entity reads and
# writes the vendor form, which is the one confirmed on hardware here --
# note that air_purifier.py found the opposite ordering on its family, so
# neither form is reliable sight-unseen and this one stays unmodeled.
'/airflow/0',
# --- TP1X/TP2X-class housekeeping / opaque blobs. These carry no
# user-actionable state or no documented write contract, so per the
# 'don't guess' rule they are ignored rather than modeled.
@@ -240,7 +879,14 @@ _AC_IGNORED = [
'/mds/absencemonitoring/vs/0', # motion-detection sensor plumbing (empty here)
'/mds/absencestate/vs/0', # motion-detection state (empty here)
'/remotedatacontrol/vs/0', # remote data-control session status
'/remotedeviceinfo/vs/0', # remote paired-device id list (empty didList here)
'/remotetemperature/vs/0', # external temp-sensor feed (unset on this unit)
# Manual airflow-step position (supportedModes Off/80/60/40/Power).
# Overlaps the /wind/direction swing control already on the climate card,
# and the meaning of the numeric steps vs. 'Power' isn't documented in the
# dump -- ignored per the 'don't guess' rule rather than modeled as a
# select whose write could confuse live HVAC hardware.
'/stepcontrol/vs/0',
'/reserverulesets/vs/0', # opaque hex-encoded schedule reservation blob
'/welcome/temperature/vs/0', # welcome-cooling plumbing
# System-AC-only (multi-indoor-unit commercial installs, e.g.
@@ -248,11 +894,27 @@ _AC_IGNORED = [
# topology -- indoor/outdoor unit pairing, per-unit serials, MCU info.
# Commissioning-time plumbing, not user-actionable appliance state.
'/sac/installationinfo/vs/0',
# Wind-Free 2-in-1 systems (one outdoor unit driving a floor-standing
# *and* a wall-mounted indoor unit over one shared local IP, e.g.
# TP2X_FAC_BORA_21K, issues #150/#153): an opaque paired-subdevice id
# list, same "remote device ids, not user-actionable locally" role as
# /remotedeviceinfo/vs/0 above. This integration talks to whichever
# single local endpoint the config entry was set up against; the
# second indoor unit isn't independently reachable through this
# resource (or any other in the dump) -- it would need its own local
# DTLS session/IP, which SmartThings pairing doesn't expose here.
'/subdevices/vs/0',
# Undocumented single int (runningMode: 0 on every dump seen), no
# supported-values list to interpret it against -- 'don't guess'.
'/runn/vs/0',
]
# Built as bare no-entity caps; folded into the AC registry (not global).
# HREF_TEMP_CURRENT and HREF_TEMPS_VS are excluded here -- CURRENT_TEMPERATURE
# / CURRENT_TEMPERATURE_VS above already cover those two with real entities.
COVERAGE = [
Capability(href=h, poll_tier='warm') for h in CLIMATE_CONSUMED_HREFS
if h not in (HREF_TEMP_CURRENT, HREF_TEMPS_VS)
] + [
Capability(href=h) for h in _AC_IGNORED
]
@@ -10,6 +10,9 @@ against live device dumps:
/water/consumption/vs/0 -> x.com.samsung.da.cumulativeWater
/filter/waterfilter/vs/0 -> x.com.samsung.da.filterUsage / filterStatus
"""
from datetime import datetime, timezone
from ..batch import is_stub_rep
from ..capability import Capability
from ..entities import (
BinarySensorDesc, ButtonDesc, SelectDesc, SensorDesc, SwitchDesc,
@@ -40,6 +43,35 @@ def wh_to_kwh(v):
return round(n / 1000.0, 2) if n is not None else None
def parse_iso_utc(raw):
"""ISO datetime defaulting to UTC when the string carries no timezone
of its own (this integration's convention for other bare ISO datetime
fields -- see washer.py's drum-clean-log comment). A few boards do
ship a 'Z'/offset suffix (fromisoformat parses that natively since
Python 3.11) -- only fill in UTC when parsing left the result naive,
rather than unconditionally overwriting whatever offset was parsed."""
if not raw:
return None
try:
dt = datetime.fromisoformat(raw)
except ValueError:
return None
return dt if dt.tzinfo is not None else dt.replace(tzinfo=timezone.utc)
def filter_usage_percent(rep):
"""Filter usage as a percentage of rated capacity. Several families
(AC, air purifier) report `filterUsage` as a raw count in
`filterCapacityUnit` (Hours, e.g. 100 of a 500 capacity), so a plain
value with a '%' unit would be wrong -- normalize to used/capacity.
Returns None when capacity is missing/zero."""
used = _num(rep.get('x.com.samsung.da.filterUsage'))
cap = _num(rep.get('x.com.samsung.da.filterCapacity'))
if used is None or not cap:
return None
return round(used / cap * 100)
def normalize_temp_unit(raw, default='°F'):
"""'C'/'Celsius' -> '°C', 'F'/'Fahrenheit' -> '°F'. Falls back to
`default` for any other/missing value. Shared by fridge.py and oven.py,
@@ -59,9 +91,35 @@ def _ml_to_l(v):
def _active_alarm_codes(items):
"""Join active alarm codes; skip retained rows Samsung leaves as Deleted,
and any code ending in '_OFF'.
Laundry boards keep a Deleted ErrorCode row in /alarms/vs/0 after the
condition clears (see WD7000B diagnostics). Surface only live alarms so
HA doesn't stick on a stale ErrorCode.
Samsung pre-populates this array with one row per alarm *type* the board
supports, each carrying its own '<Name>_OFF' placeholder code when that
alarm isn't firing -- confirmed across independent device families
(ErrorCode_OFF, FilterAlarm_OFF, OV_E_OFF, CT_E_OFF, WaterTankFull_OFF,
AC_V_0002_OFF all appear in fixtures with no corresponding active
condition). An alarm that's actually firing instead reports a plain,
unsuffixed code (FilterAlarm, DoorA_Opened, SNSF_Reached) -- issue #166's
AC dump has both a FilterAlarm_OFF placeholder and shows what a live
filter alert looks like: code 'FilterAlarm' (no suffix), state
'Created'. Range-hood previously special-cased only the literal
'ErrorCode_OFF' string in its own stricter helper; this generalizes
the same rule to the whole '_OFF' suffix convention.
"""
if not items or not isinstance(items, list):
return 'none'
codes = [i.get('x.com.samsung.da.code') for i in items if i.get('x.com.samsung.da.code')]
codes = [
i.get('x.com.samsung.da.code')
for i in items
if i.get('x.com.samsung.da.code')
and str(i.get('x.com.samsung.da.state', '')).lower() != 'deleted'
and not str(i.get('x.com.samsung.da.code', '')).lower().endswith('_off')
]
return ', '.join(codes) if codes else 'none'
@@ -92,6 +150,80 @@ def merge_options_field(cached, new_tokens):
return merged
def merge_items_field(cached, new_items):
"""Merge a partial x.com.samsung.da.items[]-style write (matched by
x.com.samsung.da.id) into a cached items array -- the read-side
counterpart of merge_options_field above, for the items[] shape instead
of the packed options[] shape.
Confirmed on hardware that a write only needs to carry the array item
with the changed id plus the field(s) being changed; the device merges
the rest itself (same fact as the options[] case, different array --
see airconditioner._climate_write's vendor temperature write). Fields
within the matched item are merged, not replaced outright, so a
setpoint-only write doesn't wipe current/minimum/maximum/unit from the
optimistic cache entry for the settle window. An id with no match in
`cached` is appended."""
merged = [dict(i) if isinstance(i, dict) else i for i in (cached or [])]
for new_item in new_items or ():
if not isinstance(new_item, dict):
continue
item_id = new_item.get('x.com.samsung.da.id')
for i, existing in enumerate(merged):
if isinstance(existing, dict) and existing.get('x.com.samsung.da.id') == item_id:
merged[i] = {**existing, **new_item}
break
else:
merged.append(new_item)
return merged
# /wm/setinfo/vs/0 -- laundry-family firmware capability flags. Present on
# washers, dryers, and dishwashers; absent on fridge/oven/AC. Static for the
# life of a given board, so reading them from the /device/0 seed (no dedicated
# poll_tier) is enough.
_SETINFO_HREF = '/wm/setinfo/vs/0'
_POWER_ON_OFF_FIELD = 'x.com.samsung.da.isModelSettingPowerOnOff'
_WITHOUT_SC_FIELD = 'x.com.samsung.da.isModelSettingWithoutSC'
def model_allows_power_on_off(resources: dict) -> bool:
"""True unless firmware explicitly declares remote power on/off unsupported.
`/wm/setinfo/vs/0`.`isModelSettingPowerOnOff` is `"false"` on many laundry
boards (washers/dryers): `/power/0` and `/power/vs/0` still report state,
but CoAP writes are ignored. Absent setinfo (non-laundry families) keeps
the writable switch -- current behavior.
"""
setinfo = resources.get(_SETINFO_HREF)
if setinfo is None:
return True
flag = setinfo.get(_POWER_ON_OFF_FIELD)
if flag is None:
return True
return str(flag).lower() != 'false'
def model_setting_without_sc(resources: dict) -> bool:
"""True when firmware declares settings writable without Smart Control.
`/wm/setinfo/vs/0`.`isModelSettingWithoutSC` is `"true"` on washers/dryers
that accept temperature/spin/cycle-option writes while remote control is
off. Cycle start/pause/stop still need Smart Control on those boards --
the flag name is settings-specific, not a blanket remote-control bypass.
"""
setinfo = resources.get(_SETINFO_HREF) or {}
return str(setinfo.get(_WITHOUT_SC_FIELD, '')).lower() == 'true'
def _power_switch_exists(rep, resources):
return model_allows_power_on_off(resources)
def _power_sensor_exists(rep, resources):
return not model_allows_power_on_off(resources)
def sensor_item_value(items, sensor_type, index=0):
"""Pull one reading out of a `/sensors/vs/0`-style items[] list -- each
item is `{type, value: [...]}`; `index` picks which slot of a possibly
@@ -128,11 +260,17 @@ def sensor_item_value(items, sensor_type, index=0):
POWER_GENERIC = Capability(
href='/power/0',
entities=(
# Writable when firmware allows remote power; otherwise a read-only
# binary_sensor with the same key keeps HA state without a dead switch.
SwitchDesc(key='power_switch', field='value',
name='Power',
value_fn=lambda v: bool(v),
exists_fn=_power_switch_exists,
write_fn=lambda p, rep, href=None: (
['power', '0'], {'value': p == 'On'})),
BinarySensorDesc(key='power_switch', field='value',
device_class='power',
value_fn=lambda v: bool(v),
exists_fn=_power_sensor_exists),
),
)
@@ -141,11 +279,15 @@ POWER_VS_FALLBACK = Capability(
match_fn=lambda rep, resources: '/power/0' not in resources,
entities=(
SwitchDesc(key='power_switch', field='x.com.samsung.da.power',
name='Power',
value_fn=lambda v: v == 'On',
exists_fn=_power_switch_exists,
write_fn=lambda p, rep, href=None: (
['power', 'vs', '0'],
{'x.com.samsung.da.power': 'On' if p == 'On' else 'Off'})),
BinarySensorDesc(key='power_switch', field='x.com.samsung.da.power',
device_class='power',
value_fn=lambda v: v == 'On',
exists_fn=_power_sensor_exists),
),
)
@@ -153,7 +295,7 @@ KIDS_LOCK_GENERIC = Capability(
href='/kidslock/0',
entities=(
SwitchDesc(key='child_lock', field='value',
name='Child lock', device_class='lock',
device_class='lock',
value_fn=lambda v: bool(v),
write_fn=lambda p, rep, href=None: (
['kidslock', '0'], {'value': p == 'On'})),
@@ -165,7 +307,7 @@ KIDS_LOCK_VS_FALLBACK = Capability(
match_fn=lambda rep, resources: '/kidslock/0' not in resources,
entities=(
SwitchDesc(key='child_lock', field='x.com.samsung.da.kidsLock',
name='Child lock', device_class='lock',
device_class='lock',
value_fn=lambda v: v != 'Ready',
write_fn=lambda p, rep, href=None: (
['kidslock', 'vs', '0'],
@@ -194,12 +336,26 @@ def remote_control_enabled(resources: dict) -> bool:
return True
def remote_control_required_for_write(resources: dict, bound_href: str) -> bool:
"""Whether a write to bound_href should be gated on Smart Control.
When isModelSettingWithoutSC is true, laundry firmware accepts settings
writes (wash temp, spin, course options, buzzer, ...) with remote
control off, but cycle start/pause/stop on /operational/state still
need Smart Control. Absent that flag, keep the historical blanket gate.
"""
if not model_setting_without_sc(resources):
return True
href = bound_href or ''
return href.startswith('/operational/state')
REMOTE_CONTROL_GENERIC = Capability(
href='/remotectrl/0',
poll_tier='warm',
entities=(
BinarySensorDesc(key='remote_control', field='value',
name='Smart Control', device_class='connectivity',
device_class='connectivity',
value_fn=lambda v: bool(v)),
),
)
@@ -211,7 +367,7 @@ REMOTE_CONTROL_VS_FALLBACK = Capability(
entities=(
BinarySensorDesc(key='remote_control',
field='x.com.samsung.da.remoteControlEnabled',
name='Smart Control', device_class='connectivity',
device_class='connectivity',
value_fn=lambda v: str(v).lower() == 'true'),
),
)
@@ -221,7 +377,7 @@ ALARMS = Capability(
poll_tier='hot',
entities=(
SensorDesc(key='alarm_code', field='x.com.samsung.da.items',
name='Alarm code', icon='mdi:alert',
icon='mdi:alert',
entity_category='diagnostic', value_fn=_active_alarm_codes),
),
)
@@ -239,53 +395,56 @@ _DEAD_INSTANTANEOUS_POWER = '-500'
ENERGY_METER = Capability(
href='/energy/consumption/vs/0',
entities=(
# `not rep` keeps the empty-{} stub carve-out (see entity._is_included):
# `is_stub_rep(rep)` keeps the stub carve-out (see entity._is_included):
# an explicit exists_fn otherwise bypasses it, which would drop the
# entity when /device/0 returns a not-yet-fetched stub. On a populated
# rep, hide power only for the dead sentinel or an absent field.
# entity when /device/0 returns a not-yet-fetched stub. A genuinely
# empty {} rep is NOT a stub -- it's the device's confirmed (if empty)
# answer, so it falls through to the normal field/sentinel checks like
# any populated rep. On a populated rep, hide power only for the dead
# sentinel or an absent field.
SensorDesc(key='power_watts', field='x.com.samsung.da.instantaneousPower',
name='Power', device_class='power', state_class='measurement',
device_class='power', state_class='measurement',
unit='W', value_fn=clamp_power,
exists_fn=lambda rep, resources: not rep or (
exists_fn=lambda rep, resources: is_stub_rep(rep) or (
rep.get('x.com.samsung.da.instantaneousPower')
not in (None, _DEAD_INSTANTANEOUS_POWER))),
SensorDesc(key='energy_kwh', field='x.com.samsung.da.cumulativePower',
name='Energy', device_class='energy',
device_class='energy',
state_class='total_increasing', unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.cumulativePower' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.cumulativePower' in rep)),
# cumulativeConsumption is a second, independently-varying running
# total alongside cumulativePower -- some fridges (issue #26) report
# both. Self-gates off where only cumulativePower is present. `not
# rep or` keeps the same empty-{} stub carve-out as power_watts/
# both. Self-gates off where only cumulativePower is present. The
# `is_stub_rep(rep) or` keeps the same stub carve-out as power_watts/
# energy_kwh above -- without it, an exists_fn permanently drops the
# entity if setup happens to land on a not-yet-fetched stub.
SensorDesc(key='power_energy_kwh', field='x.com.samsung.da.cumulativeConsumption',
name='Power energy', device_class='energy',
device_class='energy',
state_class='total_increasing', unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.cumulativeConsumption' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.cumulativeConsumption' in rep)),
# AI Energy Mode's lifetime savings estimate vs. an unoptimized
# baseline -- present on some models (e.g. TP1X_REF_21K, issue #21/
# #27) and absent on others (issue #20/#26), unlike cumulativePower.
SensorDesc(key='energy_saved_kwh', field='x.com.samsung.da.cumulativeSavedPower',
name='Energy saved', device_class='energy',
device_class='energy',
state_class='total_increasing', unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.cumulativeSavedPower' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.cumulativeSavedPower' in rep)),
# Monthly billing-cycle totals -- the completed prior month and the
# in-progress current month. Not ever-increasing (each resets at
# month boundary), so no state_class.
SensorDesc(key='energy_last_month_kwh', field='x.com.samsung.da.monthlyConsumption',
name='Energy (last month)', device_class='energy',
device_class='energy',
unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.monthlyConsumption' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.monthlyConsumption' in rep)),
SensorDesc(key='energy_this_month_kwh', field='x.com.samsung.da.thismonthlyConsumption',
name='Energy (this month)', device_class='energy',
device_class='energy',
unit='kWh', value_fn=wh_to_kwh,
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.thismonthlyConsumption' in rep)),
is_stub_rep(rep) or 'x.com.samsung.da.thismonthlyConsumption' in rep)),
),
)
@@ -293,7 +452,7 @@ WATER_METER = Capability(
href='/water/consumption/vs/0',
entities=(
SensorDesc(key='water_liters', field='x.com.samsung.da.cumulativeWater',
name='Water consumption', device_class='water',
device_class='water',
state_class='total_increasing', unit='L', icon='mdi:water',
value_fn=_ml_to_l),
),
@@ -304,10 +463,14 @@ WATER_FILTER = Capability(
match_fn=lambda rep, _: rep.get('x.com.samsung.da.filterStatus', '').lower() != 'notused',
entities=(
SensorDesc(key='filter_usage', field='x.com.samsung.da.filterUsage',
name='Filter usage', unit='%', state_class='measurement',
unit='%', state_class='measurement',
icon='mdi:filter'),
SensorDesc(key='filter_status', field='x.com.samsung.da.filterStatus',
name='Filter status', icon='mdi:filter-check'),
icon='mdi:filter-check',
device_class='enum', options=('normal', 'wash', 'replace'),
value_fn=lambda value: (
value.lower() if isinstance(value, str) else value
)),
),
)
@@ -324,7 +487,7 @@ WATER_FILTER = Capability(
#
# No translation_key: aiLevel's values are plain digit strings, and
# select.py's _display() already renders an untranslated numeric string
# as-is -- there's nothing a strings.json entry adds that's worth maintaining
# as-is -- there's nothing a catalog entry adds that's worth maintaining
# against an unknown, growing number of future levels.
@@ -354,7 +517,7 @@ AI_ENERGY_LEVEL = Capability(
href='/energy/ailevel/vs/0',
poll_tier='cold',
entities=(
# No `not rep` stub carve-out on either side, unlike most exists_fn
# No is_stub_rep carve-out on either side, unlike most exists_fn
# gates in this file -- entity creation only ever runs once, against
# whichever snapshot happens to be current the moment platforms are
# set up (see entity._is_included / __init__.py's
@@ -371,14 +534,14 @@ AI_ENERGY_LEVEL = Capability(
# cold-tier href, the same reload already required to fix which
# platform got picked in that case.
SwitchDesc(key='ai_energy_level', field='aiLevel',
name='AI energy level', icon='mdi:leaf',
icon='mdi:leaf',
entity_category='config',
value_fn=lambda v: v != '0',
exists_fn=lambda rep, resources: (
len(_ai_energy_supported_levels(rep)) == 1),
write_fn=_ai_energy_level_switch_write),
SelectDesc(key='ai_energy_level', field='aiLevel',
name='AI energy level', icon='mdi:leaf',
icon='mdi:leaf',
entity_category='config',
options=_ai_energy_level_options,
exists_fn=lambda rep, resources: (
@@ -394,7 +557,6 @@ FIRMWARE_UPDATE = Capability(
BinarySensorDesc(
key='firmware_update',
field='x.com.samsung.da.newVersionAvailable',
name='Firmware update available',
device_class='update',
entity_category='diagnostic',
value_fn=lambda v: str(v).lower() == 'true' if v is not None else None,
@@ -407,21 +569,21 @@ SELF_CHECK = Capability(
poll_tier='cold',
entities=(
SensorDesc(key='selfcheck_status', field='x.com.samsung.da.status',
name='Self-check status', icon='mdi:stethoscope',
icon='mdi:stethoscope',
entity_category='diagnostic'),
SensorDesc(key='selfcheck_result', field='x.com.samsung.da.result',
name='Self-check result', icon='mdi:clipboard-check-outline',
icon='mdi:clipboard-check-outline',
entity_category='diagnostic'),
# List of error codes from the last self-check; joined for display.
# Not every fridge reports the field, hence the exists_fn.
SensorDesc(key='selfcheck_error', field='x.com.samsung.da.error',
name='Self-check error', icon='mdi:alert-circle-outline',
icon='mdi:alert-circle-outline',
entity_category='diagnostic',
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.error' in rep),
is_stub_rep(rep) or 'x.com.samsung.da.error' in rep),
value_fn=lambda v: (', '.join(v) if v else None) if isinstance(v, list) else v),
ButtonDesc(key='selfcheck_start', field='', name='Start self-check',
payload='Start', icon='mdi:play-circle-outline',
ButtonDesc(key='selfcheck_start', field='', payload='Start',
icon='mdi:play-circle-outline',
entity_category='diagnostic',
write_fn=lambda p, rep, href=None: (
['selfcheck', 'vs', '0'], {'x.com.samsung.da.status': p})),
@@ -9,6 +9,7 @@ cooktop must not be remotely ignited by an automation.
import re
from ..batch import is_stub_rep
from ..capability import Capability
from ..entities import BinarySensorDesc, SensorDesc
@@ -61,7 +62,6 @@ COOKTOP_POWER = Capability(
BinarySensorDesc(
key='power_state',
field='x.com.samsung.da.power',
name='Power state',
device_class='power',
icon='mdi:stove',
value_fn=lambda value: str(value).lower() == 'on',
@@ -83,7 +83,6 @@ COOKTOP_MODE = Capability(
BinarySensorDesc(
key='any_burner_active',
field='x.com.samsung.da.options',
name='Any burner active',
device_class='running',
icon='mdi:fire',
value_fn=_any_burner_active,
@@ -92,13 +91,14 @@ COOKTOP_MODE = Capability(
SensorDesc(
key=f'burner_{slot}_state',
field='x.com.samsung.da.options',
name=f'Burner {slot} state',
translation_key='burner_state',
translation_placeholders={'number': str(slot)},
icon='mdi:gas-burner',
value_fn=lambda options, slot=slot: _option_value(
options, f'OperationState{slot}'
),
exists_fn=lambda rep, resources, slot=slot: (
not rep or _option_value(
is_stub_rep(rep) or _option_value(
rep.get('x.com.samsung.da.options'),
f'OperationState{slot}',
) is not None
@@ -109,14 +109,12 @@ COOKTOP_MODE = Capability(
SensorDesc(
key='main_timer_state',
field='x.com.samsung.da.options',
name='Timer state',
icon='mdi:timer-outline',
value_fn=lambda options: _option_value(options, 'MainTimerState'),
),
SensorDesc(
key='main_timer_current',
field='x.com.samsung.da.options',
name='Timer current value',
icon='mdi:timer-sand',
enabled_default=False,
value_fn=lambda options: _int_or_none(
@@ -134,7 +132,6 @@ COOKTOP_CONNECTED = Capability(
BinarySensorDesc(
key='cloud_connected',
field='x.com.samsung.da.connected',
name='Cloud connected',
device_class='connectivity',
entity_category='diagnostic',
value_fn=lambda value: str(value).lower() == 'on',
@@ -150,35 +147,30 @@ PAIRED_HOOD_STATUS = Capability(
BinarySensorDesc(
key='paired_hood_connected',
field='connectionState',
name='Paired hood connected',
device_class='connectivity',
value_fn=lambda value: str(value).lower() == 'connected',
),
BinarySensorDesc(
key='paired_hood_power',
field='power',
name='Paired hood power',
device_class='running',
value_fn=lambda value: str(value).lower() == 'on',
),
SensorDesc(
key='paired_hood_fan_speed',
field='fanSpeed',
name='Paired hood fan speed',
icon='mdi:fan',
value_fn=_int_or_none,
),
BinarySensorDesc(
key='paired_hood_light',
field='lampState',
name='Paired hood light',
device_class='light',
value_fn=lambda value: str(value).lower() == 'on',
),
SensorDesc(
key='paired_hood_model',
field='micomModelId',
name='Paired hood model',
icon='mdi:information-outline',
entity_category='diagnostic',
enabled_default=False,
@@ -186,7 +178,6 @@ PAIRED_HOOD_STATUS = Capability(
SensorDesc(
key='paired_hood_firmware',
field='firmwareVersion',
name='Paired hood firmware',
icon='mdi:chip',
entity_category='diagnostic',
enabled_default=False,
@@ -0,0 +1,85 @@
"""Capabilities for the Samsung dehumidifier family (TP1X_DA_AC_DHM-class,
issue #88, model AY18CG7500GED).
Same DA_AC_ board family as the room-AC models in airconditioner.py (shared
power/energy/filter/auto-clean/mute-once resource shapes), but target
humidity -- not temperature -- is this device's primary control, and there
is no climate composite: power, mode, and humidity are exposed as separate
entities rather than folded into one card.
"""
from ..capability import Capability
from ..entities import NumberDesc, SelectDesc, SensorDesc
from .common import int_or_none
def _first_mode(rep):
"""Representative scalar for the operating-mode select. `modes` is a
single-element list on every dump seen so far, mirroring
airconditioner._first_mode's handling of the same field shape."""
modes = rep.get('x.com.samsung.da.modes')
if isinstance(modes, (list, tuple)):
return modes[0] if modes else None
return modes
MODE = Capability(
href='/mode/vs/0',
poll_tier='warm',
entities=(
SelectDesc(key='operating_mode', rep_fn=_first_mode,
icon='mdi:tune-variant',
options_field='x.com.samsung.da.supportedModes',
write_fn=lambda p, rep, href=None: (
['mode', 'vs', '0'], {'x.com.samsung.da.modes': [p]})),
),
)
# Target humidity is this device's primary control (the issue-#88 dump's
# equivalent of a thermostat setpoint). No min/max range field is present in
# any dump seen so far -- native_min/native_max are deliberately left unset
# so the number entity falls back to HA's own 0-100 default, the natural
# bound for a percentage field, rather than a bound guessed from one unit's
# spec sheet (see the adding-device-support skill's "never hard-code the one
# dump's values" section). Step comes live from the device's own `increment`
# field.
HUMIDITY = Capability(
href='/humidity/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='humidity', field='x.com.samsung.da.humidity',
device_class='humidity', unit='%', state_class='measurement',
value_fn=int_or_none),
NumberDesc(key='target_humidity', field='x.com.samsung.da.desiredHumidity',
device_class='humidity', unit='%',
icon='mdi:water-percent',
entity_category='config',
value_fn=int_or_none,
step_fn=lambda rep: int_or_none(rep.get('increment')) or 1,
write_fn=lambda p, rep, href=None: (
['humidity', 'vs', '0'],
{'x.com.samsung.da.desiredHumidity': str(int(round(float(p))))})),
),
)
# ---------------------------------------------------------------------------
# Dehumidifier-scoped coverage: vendor plumbing with no user-actionable state
# or no documented write contract, following the same 'don't guess' rule as
# airconditioner._AC_IGNORED (this is the same DA_AC_ board family). Not in
# the global ignored.IGNORED since some of these hrefs collide with other
# families' schemas.
# ---------------------------------------------------------------------------
_DHM_IGNORED = [
'/availablecontrolsets/vs/0', # opaque hex-encoded control-set bitmap (id: DHM)
'/da/softreset/vs/0', # soft-reset trigger plumbing
'/keepnormalstate/vs/0', # internal keep-normal flag
'/personality/presence/vs/0', # presence-personalization plumbing (empty item value)
'/reserverulesets/vs/0', # opaque hex-encoded schedule reservation blob
'/sensors/vs/0', # empty {} on this dump
'/welcome/humidity/vs/0', # welcome-mode plumbing (requestId/operatingStatus, inert)
# Only supportedModes ([Off, Sleep]) is present -- no live "current
# value" field on this dump to confirm the read/write contract, so per
# the 'don't guess' rule this is left unmodeled rather than assumed.
'/mode/convenient/vs/0',
]
COVERAGE = [Capability(href=h) for h in _DHM_IGNORED]
@@ -18,13 +18,13 @@ DISHWASHER_SETTINGS = Capability(
href='/dishwasher/vs/0',
entities=(
SwitchDesc(key='sanitize', field='x.com.samsung.da.sanitize',
name='Sanitize', icon='mdi:bacteria',
icon='mdi:bacteria',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['dishwasher', 'vs', '0'],
{'x.com.samsung.da.sanitize': 'On' if p == 'On' else 'Off'})),
SelectDesc(key='heated_dry', field='x.com.samsung.da.heatedDry',
name='Smart Dry', icon='mdi:heat-wave',
icon='mdi:heat-wave',
options_field='x.com.samsung.da.supportedHeatedDry',
write_fn=lambda p, rep, href=None: (
['dishwasher', 'vs', '0'],
@@ -45,9 +45,9 @@ CYCLE_OPTIONS = Capability(
href='/course/vs/0',
entities=(
cycle_select(translation_key='dishwasher_cycle', icon='mdi:dishwasher'),
bool_option_switch('storm_wash', 'Storm Wash+', 'mdi:weather-lightning-rainy',
bool_option_switch('storm_wash', 'mdi:weather-lightning-rainy',
'StormWashZone'),
bool_option_switch('auto_release_dry', 'Auto release dry', 'mdi:door-open',
bool_option_switch('auto_release_dry', 'mdi:door-open',
'AutoDoorRelease', gate_on_presence=True),
),
)
@@ -61,10 +61,10 @@ DIAGNOSIS = Capability(
poll_tier='cold',
entities=(
SensorDesc(key='diagnosis_status', field='x.com.samsung.da.diagnosisStart',
name='Diagnosis status', icon='mdi:stethoscope',
icon='mdi:stethoscope',
entity_category='diagnostic'),
ButtonDesc(key='diagnosis_start', field='', name='Start diagnosis',
payload='Start', icon='mdi:play-circle-outline',
ButtonDesc(key='diagnosis_start', field='', payload='Start',
icon='mdi:play-circle-outline',
entity_category='diagnostic',
write_fn=lambda p, rep, href=None: (
['diagnosis', 'vs', '0'], {'x.com.samsung.da.diagnosisStart': p})),
@@ -76,7 +76,7 @@ OPERATION_ORIGIN = Capability(
poll_tier='cold',
entities=(
SensorDesc(key='operation_origin', field='origin',
name='Last operation source', icon='mdi:remote',
icon='mdi:remote',
entity_category='diagnostic'),
),
)
@@ -24,13 +24,13 @@ DRYER_SETTINGS = Capability(
poll_tier='warm',
entities=(
SensorDesc(key='dry_level', field='x.com.samsung.da.dryLevel',
name='Dry level', icon='mdi:water-percent'),
icon='mdi:water-percent'),
SensorDesc(key='dry_time', field='x.com.samsung.da.dryTime',
name='Dry time', icon='mdi:timer'),
icon='mdi:timer'),
SensorDesc(key='dryer_type', field='x.com.samsung.da.dryerType',
name='Dryer type', icon='mdi:tumble-dryer'),
icon='mdi:tumble-dryer'),
SwitchDesc(key='wrinkle_prevent', field='x.com.samsung.da.wrinklePrevent',
name='Wrinkle prevent', icon='mdi:iron',
icon='mdi:iron',
value_fn=lambda v: v == 'On',
write_fn=_wrinkle_write),
),
@@ -42,7 +42,10 @@ DRYER_SETTINGS = Capability(
# under entity.select.dryer_cycle (Table_03, DV5000-class, captured
# 2026-05-29). Codes 0x21 and 0x4C appear in the issue #14 DV90BB5245AES1
# editCourseList but aren't identified yet -- they render as the raw code
# until named. The /st/dryercourse/vs/0 resource re-encodes the same selected
# until named. Codes '01' Normal and '06' Time dry were confirmed on a
# DVE50A8600V/A3 (also Table_03) by selecting each cycle on the physical
# appliance and reading back the raw code from the entity's state (issue
# #80). The /st/dryercourse/vs/0 resource re-encodes the same selected
# course and is ignored (ignored.py) -- the mirror of how /st/washercourse/vs/0
# is ignored for washers.
DRYER_COURSE = Capability(
@@ -58,6 +61,6 @@ DRYER_DIAGNOSIS = Capability(
poll_tier='warm',
entities=(
SensorDesc(key='diagnosis', field='x.com.samsung.da.diagnosisStart',
name='Diagnosis', entity_category='diagnostic'),
entity_category='diagnostic'),
),
)
@@ -25,7 +25,7 @@ from ..entities import (
from .common import normalize_temp_unit
# Display names for the beverage zone, flex zone, ice type, and
# ice-making-status enums below live in strings.json / translations/en.json,
# ice-making-status enums below live in translations/en.json,
# keyed by the lowercased raw device value — select.py and SensorDesc.options
# normalize to lowercase for HA's translation lookup and map back to this
# original casing before writing to the device.
@@ -55,26 +55,56 @@ TEMP_CURRENT_GENERIC = Capability(
poll_tier='warm',
entities=(
SensorDesc(key='temperature', field='temperature',
name=None, icon='mdi:thermometer',
translation_key='instance_temperature',
use_instance_name=True, icon='mdi:thermometer',
device_class='temperature', unit_fn=_temp_unit,
state_class='measurement'),
),
)
TEMP_SETPOINT_GENERIC = Capability(
def _temp_setpoint_write(p, rep, href=None, resources=None):
"""Write temperature — prefer vendor /temperatures/vs/0 when available,
fall back to direct OCF /temperature/desired/ write otherwise.
Samsung fridges expose both OCF-standard /temperature/desired/* and vendor
/temperatures/vs/0. On some models only the vendor path commits the change;
on others both work. Using the vendor path when present is always correct.
Item IDs follow the Samsung convention: "0" = Freezer, "1" = Fridge/Cooler.
"""
if not href:
return None
if resources and '/temperatures/vs/0' in resources:
if '/cooler/' in href:
item_id = '1'
elif '/freezer/' in href:
item_id = '0'
else:
return None
return (
['temperatures', 'vs', '0'],
{'x.com.samsung.da.items': [
{'x.com.samsung.da.id': item_id,
'x.com.samsung.da.desired': str(int(round(float(p))))}
]}
)
return (
[s for s in href.strip('/').split('/') if s],
{'temperature': int(round(float(p)))}
)
TEMP_SETPOINT = Capability(
href=None,
href_prefix='/temperature/desired/',
strip_prefix_in_key=True,
poll_tier='warm',
entities=(
NumberDesc(key='setpoint', field='temperature',
name=None, device_class='temperature', unit_fn=_temp_unit,
translation_key='instance_setpoint',
use_instance_name=True, device_class='temperature', unit_fn=_temp_unit,
native_min=-20.0, native_max=50.0,
range_field='range', entity_category='config',
write_fn=lambda p, rep, href=None: (
[s for s in href.strip('/').split('/') if s],
{'temperature': int(round(float(p)))}
) if href else None),
write_fn=_temp_setpoint_write),
),
)
@@ -87,7 +117,7 @@ ICEMAKER_NIGHTTIME = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='ice_night_mode', field='ice.night.status',
name='Nighttime ice quiet mode', icon='mdi:weather-night',
icon='mdi:weather-night',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
@@ -101,8 +131,9 @@ ICEMAKER_NIGHTTIME = Capability(
# /icemaker/status/vs/0 is kept as exact-href cap and binds first.
# /icemaker/nighttime/vs/0 is excluded by match_fn (lacks iceMaker.state).
#
# Entity names are derived from x.com.samsung.da.iceMaker.name ("CUBED_ICE",
# "ICE_BITES") via name_field, not the href's "one"/"two" segment -- these two
# Entity names interpolate x.com.samsung.da.iceMaker.name ("CUBED_ICE",
# "ICE_BITES") -- read via name_field, reaching the translated name as the
# {instance_name} placeholder -- not the href's "one"/"two" segment. These two
# ice makers are independent on/off toggles that can both be enabled at once
# (issue #27), so they stay separate entities rather than a single ice-type
# select, but users still want them labeled with the device's own names.
@@ -123,17 +154,18 @@ ICEMAKER_GENERIC = Capability(
entities=(
SensorDesc(key='making_status',
field='x.com.samsung.da.iceMaker.iceMakingStatus',
name=None, icon='mdi:cube-outline',
use_instance_name=True, icon='mdi:cube-outline',
device_class='enum',
options=('icestatus_stop', 'icestatus_run'),
translation_key='ice_making_status',
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
SwitchDesc(key='enabled', field='x.com.samsung.da.iceMaker.state',
name=None, icon='mdi:cube-outline',
translation_key='instance_enabled',
use_instance_name=True, icon='mdi:cube-outline',
value_fn=lambda v: v == 'On',
write_fn=_icemaker_write('x.com.samsung.da.iceMaker.state')),
SelectDesc(key='type', field='x.com.samsung.da.iceType.desired',
name=None, icon='mdi:cube-outline',
use_instance_name=True, icon='mdi:cube-outline',
translation_key='ice_type',
entity_category='config',
options_field='x.com.samsung.da.iceType.supported',
@@ -151,7 +183,7 @@ DOOR_ALERT = Capability(
poll_tier='warm',
entities=(
SelectDesc(key='door_alert', field='alert.door',
name='Door alarm', icon='mdi:bell-alert',
icon='mdi:bell-alert',
translation_key='door_alert',
entity_category='config',
options_field='supportedAlert.door',
@@ -177,12 +209,12 @@ STATUS_LOCK = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='auto_door_opener', field='x.com.samsung.da.ado.devicecontrol',
name='Auto door opener', icon='mdi:door-open',
icon='mdi:door-open',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=_status_lock_write('x.com.samsung.da.ado.devicecontrol')),
SwitchDesc(key='fridge_sound', field='x.com.samsung.da.device.sound',
name='Sound', icon='mdi:volume-high',
icon='mdi:volume-high',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=_status_lock_write('x.com.samsung.da.device.sound')),
@@ -207,7 +239,7 @@ DEFROST_DELAY = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='defrost_delay', field='x.com.samsung.da.delayDefrost',
name='Defrost delay', icon='mdi:snowflake-off',
icon='mdi:snowflake-off',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
@@ -229,7 +261,7 @@ DEFROST_BLOCK_STATUS = Capability(
poll_tier='warm',
entities=(
BinarySensorDesc(key='defrost_active', field='x.com.samsung.da.modes',
name='Defrost active', icon='mdi:snowflake-melt',
icon='mdi:snowflake-melt',
entity_category='diagnostic',
value_fn=lambda modes: bool(modes) and modes[0] == 'DEFROST_BLOCK_ON'),
),
@@ -252,12 +284,12 @@ REFRIGERATION = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='rapid_fridge', field='x.com.samsung.da.rapidFridge',
name='Rapid fridge', icon='mdi:fridge-industrial',
icon='mdi:fridge-industrial',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=_refrigeration_write('x.com.samsung.da.rapidFridge')),
SwitchDesc(key='rapid_freezing', field='x.com.samsung.da.rapidFreezing',
name='Rapid freezing', icon='mdi:snowflake',
icon='mdi:snowflake',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=_refrigeration_write('x.com.samsung.da.rapidFreezing')),
@@ -279,7 +311,7 @@ AUTOFILL = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='autofill', field='x.com.samsung.da.autofill',
name='Autofill pitcher', icon='mdi:cup-water',
icon='mdi:cup-water',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=_autofill_write),
@@ -295,7 +327,7 @@ WELCOME_LIGHTING = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='welcome_lighting', field='status',
name='Welcome lighting', icon='mdi:motion-sensor',
icon='mdi:motion-sensor',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
@@ -386,15 +418,15 @@ CABINET_LIGHT_ENHANCED = Capability(
poll_tier='warm',
entities=(
SelectDesc(key='day_brightness', field='level.brightness.daytime',
name='Cabinet brightness', icon='mdi:brightness-5',
translation_key='brightness_level',
icon='mdi:brightness-5',
translation_key='day_brightness',
entity_category='config',
options=_NIGHT_BRIGHTNESS_OPTIONS,
write_fn=lambda p, rep, href=None: (
['cabinet', 'light', 'enhanced', 'vs', '0'],
{'level.brightness.daytime': p})),
SelectDesc(key='brightness_level', field='level.brightness.nighttime',
name='Night brightness', icon='mdi:brightness-4',
icon='mdi:brightness-4',
translation_key='brightness_level',
entity_category='config',
options=_NIGHT_BRIGHTNESS_OPTIONS,
@@ -402,12 +434,12 @@ CABINET_LIGHT_ENHANCED = Capability(
['cabinet', 'light', 'enhanced', 'vs', '0'],
{'level.brightness.nighttime': p})),
TimeDesc(key='night_start', field='',
name='Night light start', icon='mdi:clock-start',
icon='mdi:clock-start',
entity_category='config',
rep_fn=_night_start_value,
write_fn=_night_start_write),
TimeDesc(key='night_end', field='',
name='Night light end', icon='mdi:clock-end',
icon='mdi:clock-end',
entity_category='config',
rep_fn=_night_end_value,
write_fn=_night_end_write),
@@ -431,11 +463,11 @@ CABINET_LIGHT = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='cabinet_light_switch', field='x.com.samsung.da.lightControl',
name='Cabinet light', icon='mdi:fridge-outline',
icon='mdi:fridge-outline',
value_fn=lambda v: v == 'On',
write_fn=_cabinet_light_write),
SwitchDesc(key='cabinet_light_dim', field='light.dimming.status',
name='Brighten gradually', icon='mdi:brightness-auto',
icon='mdi:brightness-auto',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
@@ -459,7 +491,7 @@ SABBATH = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='sabbath_mode', field='x.com.samsung.da.sabbathMode',
name='Sabbath mode', icon='mdi:hands-pray',
icon='mdi:hands-pray',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=_sabbath_write),
@@ -479,7 +511,7 @@ BEVERAGE_ZONE = Capability(
poll_tier='warm',
entities=(
SelectDesc(key='beverage_zone_mode', field='roomDesiredMode',
name='Beverage zone mode', icon='mdi:glass-wine',
icon='mdi:glass-wine',
translation_key='beverage_zone_mode',
entity_category='config',
options_field='roomSupportedModes',
@@ -507,7 +539,7 @@ PANTRY_ZONE = Capability(
poll_tier='warm',
entities=(
SelectDesc(key='pantry_zone_mode', field='x.com.samsung.da.mode',
name='Pantry zone mode', icon='mdi:glass-wine',
icon='mdi:glass-wine',
translation_key='pantry_zone_mode',
entity_category='config',
options_field='x.com.samsung.da.supportedOptions',
@@ -554,12 +586,21 @@ FLEX_ZONE = Capability(
poll_tier='warm',
entities=(
SelectDesc(key='flex_zone_mode',
name='Flex zone mode', icon='mdi:thermostat',
icon='mdi:thermostat',
translation_key='flex_zone_mode',
entity_category='config',
options_field='x.com.samsung.da.supportedOptions',
exists_fn=lambda rep, resources: bool(
rep.get('x.com.samsung.da.supportedOptions')),
# A nonempty supportedOptions alone isn't sufficient: the
# kimchi-refrigerator family (issue #26) also populates
# /mode/vs/0's modes/supportedOptions with real data, but
# its tokens carry a "_[n]:[n]" parameter suffix on
# supportedOptions that modes never repeats, so no item
# ever overlaps -- the RF9000/Bespoke-class overlap this
# capability was built for never happens there. Require an
# actual resolvable value instead of just a populated
# list, so this stays absent on that family rather than
# showing a select permanently stuck on "unknown".
exists_fn=lambda rep, resources: _flex_zone_current(rep) is not None,
rep_fn=_flex_zone_current,
write_fn=_flex_zone_write),
),
@@ -569,14 +610,126 @@ FLEX_ZONE = Capability(
# Generic door pattern capability (href=None — use as pattern_cap only)
# ---------------------------------------------------------------------------
def _door_open_state(rep):
"""Most /door/* resources report bare `openState`, but the
ARTIK051_DONGLE_REF family's /door/onedoorfreezer/vs/0 (issues #77, #83)
reports the vendor-prefixed `x.com.samsung.da.openState` instead. This
capability still binds either way (href_prefix match doesn't care about
field names), but a plain `field=` lookup against the wrong key means
the entity exists and is permanently unavailable -- check both."""
v = rep.get('openState')
if v is None:
v = rep.get('x.com.samsung.da.openState')
return v == 'Open'
DOOR_GENERIC = Capability(
href=None,
href_prefix='/door/',
poll_tier='hot',
entities=(
BinarySensorDesc(key='open', field='openState',
name=None, device_class='door',
value_fn=lambda v: v == 'Open'),
BinarySensorDesc(key='open', rep_fn=_door_open_state,
translation_key='instance_open',
use_instance_name=True, device_class='door'),
),
)
# ---------------------------------------------------------------------------
# Kimchi refrigerator compartments (TP2X_REF_20K-class 3-compartment kimchi
# units, issue #26) -- top/middle/bottom each report their own storage mode
# plus a ripening status/timer on /status/kimchi/<slot>/vs/0, all three in
# an identical shape; modeled as a pattern capability the same way
# DOOR_GENERIC/TEMP_CURRENT_GENERIC above are, deriving the per-compartment
# key and {instance_name} from the href's top/middle/bottom segment. Only
# the top compartment's door has been seen reported separately (kimchidoors);
# middle/bottom apparently have no contact switch of their own, so that's
# its own narrower pattern cap rather than assumed universal.
#
# The same state is also mirrored -- packed into single tokens like
# "KIMCHIT_KIMCHI_STORAGE_NORMAL" (T/M/B prefix per compartment) with
# bracketed parameters -- on /mode/vs/0, the same resource FLEX_ZONE reads
# for RF9000-class fridges. /status/kimchi/<slot>/vs/0's plain currentMode/
# supportMode fields are unpacked and self-describing, so that's what this
# binds to instead.
#
# Write path is unconfirmed (no live write against a real unit) -- same
# "write the same field back to the entity's own href" convention as
# PANTRY_ZONE/BEVERAGE_ZONE above, first real-world write is also the test.
#
# translations/en.json's kimchi_zone_mode state labels were translated
# directly from the reporter's own (Korean-language) SmartThings app
# screenshots, not guessed from the codes or from their English paraphrase.
# Cross-checking the screenshots against supportMode confirms the on-screen
# option order matches the array order everywhere it's verifiable: the top
# compartment's freezer triplet (표준/강냉/약냉 = Standard/Strong/Weak, at
# -19/-21/-17°C) lines up 1:1 with STORAGE_FREEZER_NORMAL/COLD/WARM, and the
# middle/bottom compartments' full 8-entry kimchi-storage list, 2-entry
# ripening list, and 4-entry custom-storage list each line up 1:1 with their
# supportMode order too -- so COLD/WARM consistently means Strong/Weak (a
# colder or warmer preset around the NORMAL setpoint) everywhere that suffix
# appears, including on STORAGE_FRIDGE_* and the low-salt kimchi variants,
# which weren't directly screenshotted but share the same NORMAL/COLD/WARM
# vocabulary as the two confirmed triplets. CRUNFCH (아삭, "crisp/crunchy")
# and BUY (구입, "purchased") are also confirmed exact matches, not
# abbreviation guesses.
# ---------------------------------------------------------------------------
def _kimchi_mode_write(p, rep, href=None):
if not href or p not in (rep.get('x.com.samsung.da.supportMode') or ()):
return None
return [s for s in href.strip('/').split('/') if s], {
'x.com.samsung.da.currentMode': p,
}
KIMCHI_ZONE = Capability(
href=None,
href_prefix='/status/kimchi/',
strip_prefix_in_key=True,
poll_tier='warm',
entities=(
SelectDesc(key='mode', field='x.com.samsung.da.currentMode',
use_instance_name=True, icon='mdi:fridge-outline',
translation_key='kimchi_zone_mode',
entity_category='config',
options_field='x.com.samsung.da.supportMode',
write_fn=_kimchi_mode_write),
SensorDesc(key='ripening_status', field='x.com.samsung.da.ripeStatus',
use_instance_name=True, icon='mdi:progress-clock',
translation_key='kimchi_ripening_status',
entity_category='diagnostic'),
SensorDesc(key='ripening_remaining', field='x.com.samsung.da.ripeRemaintime',
use_instance_name=True, icon='mdi:timer-sand',
translation_key='kimchi_ripening_remaining',
entity_category='diagnostic',
# No dump has this nonzero (ripeStatus is always "Off" so
# far) -- device-reported unit unconfirmed, so this stays
# a bare number rather than asserting minutes or hours.
value_fn=_int),
SensorDesc(key='rack_count', field='x.com.samsung.da.rackCount',
use_instance_name=True, icon='mdi:tray-full',
translation_key='kimchi_rack_count',
entity_category='diagnostic', enabled_default=False,
value_fn=_int),
),
)
KIMCHI_DOOR_GENERIC = Capability(
href=None,
href_prefix='/kimchidoors/',
strip_prefix_in_key=True,
poll_tier='hot',
entities=(
# Not deduped against DOORS_FALLBACK below: on the one reporter
# (refrigerator_tp2x_ref_20k_kimchi) this binds alongside, the
# /doors/vs/0 aggregate carries a single generic item (id "4", no
# /door/<instance> siblings for DOORS_FALLBACK's match_fn to see)
# that doesn't share this compartment's "top" instance numbering --
# a distinct main-cabinet door, not this kimchi drawer's own contact
# switch reported twice.
BinarySensorDesc(key='open', rep_fn=_door_open_state,
translation_key='instance_open',
use_instance_name=True, device_class='door'),
),
)
@@ -604,7 +757,7 @@ DOORS_FALLBACK = Capability(
poll_tier='hot',
entities=(
BinarySensorDesc(key='door_open', field='x.com.samsung.da.items',
name='Door', device_class='door',
device_class='door',
value_fn=lambda items: any(
i.get('x.com.samsung.da.openState') == 'Open'
for i in (items or []))),
@@ -636,13 +789,13 @@ TEMPERATURES_FALLBACK = Capability(
poll_tier='warm',
entities=(
SensorDesc(key='freezer_temperature', field='x.com.samsung.da.items',
name='Freezer temperature', icon='mdi:thermometer',
icon='mdi:thermometer',
device_class='temperature', state_class='measurement',
unit_fn=lambda rep: _temp_item_unit(
rep.get('x.com.samsung.da.items'), 'Freezer'),
value_fn=lambda items: _temp_item_value(items, 'Freezer')),
SensorDesc(key='fridge_temperature', field='x.com.samsung.da.items',
name='Fridge temperature', icon='mdi:thermometer',
icon='mdi:thermometer',
device_class='temperature', state_class='measurement',
unit_fn=lambda rep: _temp_item_unit(
rep.get('x.com.samsung.da.items'), 'Fridge'),
@@ -665,7 +818,7 @@ ICEMAKER_STATUS_FALLBACK = Capability(
poll_tier='warm',
entities=(
SwitchDesc(key='ice_maker_enabled', field='x.com.samsung.da.iceMaker',
name='Ice maker', icon='mdi:cube-outline',
icon='mdi:cube-outline',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['icemaker', 'status', 'vs', '0'],
@@ -695,17 +848,17 @@ REFRIGERATION_FALLBACK = Capability(
poll_tier='warm',
entities=(
BinarySensorDesc(key='defrost_active', field='defrost',
name='Defrost active', icon='mdi:snowflake-melt',
icon='mdi:snowflake-melt',
entity_category='diagnostic',
value_fn=lambda v: bool(v),
exists_fn=lambda rep, resources: '/defrost/block/vs/0' not in resources),
BinarySensorDesc(key='rapid_fridge', field='rapidCool',
name='Rapid fridge', icon='mdi:fridge-industrial',
icon='mdi:fridge-industrial',
entity_category='config',
value_fn=lambda v: bool(v),
exists_fn=lambda rep, resources: '/refrigeration/vs/0' not in resources),
BinarySensorDesc(key='rapid_freezing', field='rapidFreeze',
name='Rapid freezing', icon='mdi:snowflake',
icon='mdi:snowflake',
entity_category='config',
value_fn=lambda v: bool(v),
exists_fn=lambda rep, resources: '/refrigeration/vs/0' not in resources),
@@ -53,6 +53,10 @@ IGNORED: list[Capability] = [
Capability(href='/setting/vs/0'), # supported/selected UI language
Capability(href='/timezone/vs/0'), # redundant with HA's own timezone
Capability(href='/wm/setinfo/vs/0'), # model/manufacturing metadata
# Resource-monitoring poll-interval config (a bare minPeriod in
# milliseconds, issue #165's TP1X_REF_21K fridge) -- internal transport
# plumbing, not appliance state.
Capability(href='/rm/control/vs/0'),
# Demand Response Load Control — utility-company grid signals; requires
# cloud registration with a utility program we don't support locally.
@@ -107,6 +111,11 @@ IGNORED: list[Capability] = [
# exposed by dryer.DRYER_COURSE at /course/vs/0
# (x.com.samsung.da.st.dryerMode is "Table_03_Course_<same hex code>").
Capability(href='/st/dryercourse/vs/0'),
# AirDresser counterpart of the above (issue #157): read only for its
# courseTable id (air_dresser.AIR_DRESSER_COURSE's table_href), no
# entity of its own -- same "no entity, just the table id" role as
# /st/washercourse/vs/0 and /st/dryercourse/vs/0.
Capability(href='/st/airdressercourse/vs/0'),
# Empty on every washer dump seen so far.
Capability(href='/wm/welcomemsg/vs/0'),
# User-saved custom course slots (F1-FA). No controllable/observable
@@ -131,4 +140,12 @@ IGNORED: list[Capability] = [
# parallel write-capable capability around an unverified generic OCF
# write contract.
Capability(href='/operational/state/0'),
# Cooktop guided-cooking/recipe status (issue #86, TP1X_DA-KS-COOKTOP
# family): sequenceNumber, operationBurnerNumber, a stageInfo block, and
# a textData.menu string -- every field empty/zero on the only dump
# seen so far (device idle, no guided-cooking program active). Same
# "don't guess" treatment as the microwave family's /recipe/cook/vs/0.
# Revisit if a dump with an active recipe surfaces.
Capability(href='/cooktop/recipe/status/vs/0'),
]
@@ -21,6 +21,7 @@ Door-LED keys use NO `x.com.samsung.da.` prefix -- `setBrightness` /
"""
from datetime import time as dt_time
from ...catalog import has_entity_translation
from ..capability import Capability
from ..entities import NumberDesc, SelectDesc, SensorDesc, SwitchDesc, TimeDesc
@@ -60,30 +61,30 @@ DOOR_LED = Capability(
href='/doorled/light/vs/0',
entities=(
SelectDesc(key='led_brightness', field='setBrightness',
name='Door LED brightness', icon='mdi:brightness-6',
icon='mdi:brightness-6',
entity_category='config',
options=_LED_LEVELS, write_fn=_led_brightness_write),
SwitchDesc(key='led_night_light', field='setNightLight',
name='Door LED night light', icon='mdi:weather-night',
icon='mdi:weather-night',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=_led_night_write),
SelectDesc(key='led_night_brightness', field='setNightLightBrightness',
name='Door LED night brightness', icon='mdi:brightness-4',
icon='mdi:brightness-4',
entity_category='config',
options=_LED_LEVELS,
write_fn=lambda p, rep, href=None: (
['doorled', 'light', 'vs', '0'],
{'setNightLightBrightness': p})),
TimeDesc(key='led_night_start', field='setNightLightTimeStart',
name='Door LED night start', icon='mdi:clock-start',
icon='mdi:clock-start',
entity_category='config',
value_fn=_parse_hm,
write_fn=lambda p, rep, href=None: (
['doorled', 'light', 'vs', '0'],
{'setNightLightTimeStart': f'{p.hour:02d}:{p.minute:02d}'})),
TimeDesc(key='led_night_end', field='setNightLightTimeEnd',
name='Door LED night end', icon='mdi:clock-end',
icon='mdi:clock-end',
entity_category='config',
value_fn=_parse_hm,
write_fn=lambda p, rep, href=None: (
@@ -96,7 +97,7 @@ SOUND_MODE = Capability(
href='/settings/sound/mode/vs/0',
entities=(
SelectDesc(key='sound_mode', field='mode',
name='Sound mode', icon='mdi:volume-high',
icon='mdi:volume-high',
entity_category='config',
options=_SOUND_MODES, write_fn=_sound_mode_write),
),
@@ -106,7 +107,7 @@ SOUND_VOLUME = Capability(
href='/settings/sound/volume/vs/0',
entities=(
NumberDesc(key='sound_volume', field='level',
name='Sound volume', icon='mdi:volume-medium',
icon='mdi:volume-medium',
entity_category='config',
native_min=0, native_max=15, step=5,
value_fn=lambda v: int(v) if v is not None else None,
@@ -127,13 +128,13 @@ BUZZER_SOUND = Capability(
href='/buzzersound/vs/0',
entities=(
SelectDesc(key='buzzer_sound', field='setBuzzerSound',
name='Buzzer sound', icon='mdi:volume-high',
icon='mdi:volume-high',
entity_category='config',
options_field='supportedBuzzerSound',
write_fn=lambda p, rep, href=None: (
['buzzersound', 'vs', '0'], {'setBuzzerSound': p})),
SelectDesc(key='finish_sound', field='setFinishSound',
name='Finish sound', icon='mdi:bell-ring',
icon='mdi:bell-ring',
entity_category='config',
exists_fn=lambda rep, resources: 'supportedFinishSound' in rep,
options_field='supportedFinishSound',
@@ -291,23 +292,22 @@ def cycle_select(*, translation_key, icon, table_href=None):
suffixes translation_key with the device's own course-table id, read
from /st/washercourse/vs/0 or /st/dryercourse/vs/0's
x.com.samsung.da.st.courseTable (e.g. 'washer_cycle' + 'Table_02' ->
'washer_cycle_table_02'). No table id available at all -- the href
absent or empty -- gets no translation_key, i.e. the raw course code
displayed as-is.
'washer_cycle_table_02'). An absent or unrecognized table id gets the
name-only ``cycle`` translation key while the raw course code remains
visible and writable.
This matters because course codes are NOT guaranteed consistent across
board generations sharing the same /course/vs/0 contract: every code in
washer_cycle_table_02 was confirmed against Table_02-reporting devices
(DA_WM_TP1/TP2 boards); FlexWash's older DA_WM_A51 board reports
Table_00 instead, so the same hex code could mean a different course
there for all we've verified. Building the key from whatever table the
device actually reports, rather than gating a single hardcoded key on
an exact match, means a table we haven't built translations for yet
(like Table_00) just falls through Home Assistant's own missing-
translation handling to the same raw-code display -- exactly what
happens today for any individual code within a table's translations
that isn't populated yet -- and adding one later needs new strings.json
entries, not a code change here.
there for all we've verified. So a table-specific key is used only when
the shipped catalog actually has one; any other table (Table_00 today,
whatever ships next) falls back to the name-only ``cycle`` key, which
shows the raw course code rather than a label borrowed from another
board generation. Translating a new table is therefore a
translations-only change -- add the ``<family>_cycle_<table>`` entry and
this resolver picks it up.
Left at its default for dishwasher, which has no equivalent table-id
resource in any dump seen and no evidence its course codes vary by
@@ -318,10 +318,13 @@ def cycle_select(*, translation_key, icon, table_href=None):
if table_href is not None:
def key(resources):
table = _table_id(resources, table_href)
return f'{translation_key}_{table.lower()}' if table else None
if not isinstance(table, str) or not table:
return 'cycle'
candidate = f'{translation_key}_{table.lower()}'
return candidate if has_entity_translation('select', candidate) else 'cycle'
return SelectDesc(
key='cycle', name='Cycle', icon=icon, translation_key=key,
key='cycle', icon=icon, translation_key=key,
options=cycle_options,
exists_fn=lambda rep, resources: bool(cycle_options(resources)),
rep_fn=lambda rep: option_value(rep.get('x.com.samsung.da.options'), 'Course'),
@@ -360,8 +363,8 @@ def bool_option_exists(prefix):
rep.get('x.com.samsung.da.options'), prefix) is not None
def bool_option_switch(key, name, icon, prefix, *, entity_category=None,
gate_on_presence=False, validate_fn=None):
def bool_option_switch(key, icon, prefix, *, entity_category=None,
gate_on_presence=False, validate_fn=None):
"""A SwitchDesc over a '<prefix>_On'/'<prefix>_Off' options[] token.
gate_on_presence self-gates the entity off on models that never report
@@ -373,7 +376,7 @@ def bool_option_switch(key, name, icon, prefix, *, entity_category=None,
building one, if needed, is the caller's job.
"""
return SwitchDesc(
key=key, name=name, icon=icon, entity_category=entity_category,
key=key, icon=icon, entity_category=entity_category,
exists_fn=bool_option_exists(prefix) if gate_on_presence else None,
rep_fn=bool_option_value(prefix),
write_fn=bool_option_write(prefix),
@@ -396,7 +399,6 @@ JOB_BEGINNING_STATUS = Capability(
entities=(
SensorDesc(key='job_beginning_status',
field='x.com.samsung.da.currentStatus',
name='Job beginning status',
entity_category='diagnostic'),
),
)
@@ -0,0 +1,266 @@
"""Capabilities for the Samsung microwave family (TP1X_DA-KS-MICROWAVE-*
class boards, both combi units and plain microwaves).
Shares the oven board family's cavity/cook-cycle resource shape
(`/operational/state/vs/0`, `/doors/vs/0`, `/connected/vs/0`,
`/recipe/cook/vs/0`) -- those Capability objects are reused directly from
oven.py in by_type/microwave.py rather than duplicated. What's genuinely
different from an oven, and defined fresh here:
* Cooking-mode vocabulary: MicroWave/MicroWaveGrill/MicroWaveConvection/
KeepWarm never appear on an oven's /mode/vs/0, and this family spells
some shared-sounding modes differently than oven.py's own constants
(e.g. 'AirFryer', not oven.py's 'AirFry') -- a distinct SelectDesc and
mode list, not oven.OVEN_MODE.
* Setpoint bounds: this family's Convection/MicroWaveConvection modeSpec
(issue #121's MW7300B dump) reports 40-200 C / step 5, not oven.py's
30-270 C range (verified against a different, bake-oven-class board).
* Cavity: /oven/vs/0 here also carries a `powerLevel` field (100W-900W
on the MicroWave mode's powerListData) that plain ovens don't report --
exposed as its own sensor.
* Lamp: this family's option-array token is bare 'Lamp' (issue #137's
'Lamp_Off'), not oven.py's 'UpperLamp' -- and it's genuinely absent on
the combi dump (issue #121), so it's gated with exists_fn rather than
assumed universal like oven.py's lamp switch. Issue #137's dump only
ever showed 'Off', so 'On' was a guess at the paired value; issue #152's
ME7500D dump is the first to show a real non-Off value, and it's 'High'
(a brightness level, not literally 'On') -- the switch now treats any
non-Off/non-None value as "on" for reads, and writes back 'High'/'Off'
(the two confirmed tokens) rather than the never-confirmed 'On'.
* Filter reminder / end signal reminder: bare 'FilterRemind'/'RemindBeep'
option-array tokens (issue #181), both with On and Off observed live
(issue #152's ME7500D fixtures) -- gated with exists_fn like Lamp since
the MW7300B combi dump has neither.
Note: cooking-mode writes are unproven here, same caveat as oven.py's
OVEN_MODE -- exposed as a SelectDesc for fidelity, first real-world write
is also the test.
"""
from ..capability import Capability
from ..entities import NumberDesc, SelectDesc, SensorDesc, SwitchDesc
from .common import int_or_none, normalize_temp_unit
from .laundry import option_value, option_write
# ---------------------------------------------------------------------------
# Constants
# ---------------------------------------------------------------------------
# Union of every mode seen across the two known dumps: issue #121's combi
# MW7300B (NoOperation/Autocook/AutocookCustom/Convection/AirFryer/Grill/
# MicroWave/MicroWaveGrill/MicroWaveConvection/Deodorization) and issue #137's
# plain ME7500D (NoOperation/MicroWave/Autocook/KeepWarm). No dump has shown
# every mode below on one device -- the select surfaces whatever a given
# board's own /mode/vs/0 supportedModes reports; an entry here that a device
# never sends just never gets picked.
_MICROWAVE_MODES = (
'NoOperation',
'MicroWave',
'MicroWaveGrill',
'MicroWaveConvection',
'Convection',
'AirFryer',
'Grill',
'Autocook',
'AutocookCustom',
'Deodorization',
'KeepWarm',
)
# Convection/MicroWaveConvection modeSpec on issue #121's dump: tempMinC 40,
# tempMaxC 200, tempIntervalC 5. No Fahrenheit dump exists for this family;
# unlike oven.py's own SETPOINT_MIN_F/MAX_F/STEP_F (independently verified
# against issue #44's range dump), there's nothing to verify a microwave's
# Fahrenheit bounds against, so this module only exposes the setpoint
# control when the live unit is Celsius (see _microwave_temp_unit below).
SETPOINT_MIN_C = 40
SETPOINT_MAX_C = 200
SETPOINT_STEP_C = 5
def _microwave_temp_unit(rep):
"""Same shape as oven.py's _oven_temp_unit: /temperatures/vs/0 items[]
carries a per-item x.com.samsung.da.unit field. Both known dumps for
this family report 'Celsius'; kept live rather than hardcoded per the
fridge/oven convention (issue #7)."""
items = rep.get('x.com.samsung.da.items') or []
unit = items[0].get('x.com.samsung.da.unit') if items else None
return normalize_temp_unit(unit, default='°C')
def _setpoint_write(p, rep, href=None):
"""RMW write to /temperatures/vs/0 items array -- unproven for this
family (no live write confirmed against a real unit), same "exposed for
fidelity" caveat as the mode select."""
try:
temp = float(p)
except (TypeError, ValueError):
return None
temp_i = int(round(temp / SETPOINT_STEP_C) * SETPOINT_STEP_C)
if not (SETPOINT_MIN_C <= temp_i <= SETPOINT_MAX_C):
return None
items = rep.get('x.com.samsung.da.items')
if not items:
return None
items = [dict(it) for it in items]
items[0]['x.com.samsung.da.desired'] = str(temp_i)
return ['temperatures', 'vs', '0'], {'x.com.samsung.da.items': items}
def _power_level_watts(v):
"""'100W'..'900W' (issue #121) or a bare '0' (issue #137) -> int watts."""
if v is None:
return None
s = str(v).strip()
if s.upper().endswith('W'):
s = s[:-1]
return int_or_none(s)
def _cooking_mode_options(resources):
"""Live mode list from the device's own /mode/vs/0 supportedModes when
it reports one (both known dumps do); the union-of-all-dumps
_MICROWAVE_MODES guess otherwise. Same live-first, static-fallback
pattern as oven._oven_mode_options -- a fixed list here would offer
users modes their own unit doesn't have (issue #152's ME7500D reports
only 4 of _MICROWAVE_MODES' 11)."""
rep = resources.get('/mode/vs/0') or {}
live = rep.get('x.com.samsung.da.supportedModes')
return list(live) if live else list(_MICROWAVE_MODES)
def _mode_write(p, rep, href=None):
valid = rep.get('x.com.samsung.da.supportedModes') or _MICROWAVE_MODES
if p not in valid:
return None
return ['mode', 'vs', '0'], {'x.com.samsung.da.modes': [p]}
def _sound_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
if not rep.get('x.com.samsung.da.options'):
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': option_write('Sound', p),
}
def _lamp_exists(rep, resources):
return option_value(rep.get('x.com.samsung.da.options'), 'Lamp') is not None
def _filter_remind_exists(rep, resources):
return option_value(rep.get('x.com.samsung.da.options'), 'FilterRemind') is not None
def _remind_beep_exists(rep, resources):
return option_value(rep.get('x.com.samsung.da.options'), 'RemindBeep') is not None
def _lamp_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
if not rep.get('x.com.samsung.da.options'):
return None
# 'High' and 'Off' are the two tokens actually confirmed on live dumps
# (issues #137/#152) -- 'On' has never been observed and the device
# likely doesn't recognize it (see module docstring).
token = 'High' if p == 'On' else 'Off'
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': option_write('Lamp', token),
}
def _filter_remind_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
if not rep.get('x.com.samsung.da.options'):
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': option_write('FilterRemind', p),
}
def _remind_beep_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
if not rep.get('x.com.samsung.da.options'):
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': option_write('RemindBeep', p),
}
# ---------------------------------------------------------------------------
# Capabilities
# ---------------------------------------------------------------------------
MICROWAVE_CAVITY = Capability(
href='/oven/vs/0',
poll_tier='hot',
entities=(
SensorDesc(key='cavity_state', field='x.com.samsung.da.state'),
SensorDesc(key='power_level', field='x.com.samsung.da.powerLevel',
unit='W', value_fn=_power_level_watts),
),
)
MICROWAVE_SETPOINT = Capability(
href='/temperatures/vs/0',
poll_tier='hot',
entities=(
NumberDesc(key='setpoint', field='x.com.samsung.da.items',
device_class='temperature', unit_fn=_microwave_temp_unit,
native_min=float(SETPOINT_MIN_C), native_max=float(SETPOINT_MAX_C),
step=float(SETPOINT_STEP_C), icon='mdi:thermometer-chevron-up',
exists_fn=lambda rep, resources: _microwave_temp_unit(rep) == '°C',
value_fn=lambda items: int_or_none(
(items[0].get('x.com.samsung.da.desired') if items else None)),
write_fn=_setpoint_write),
SensorDesc(key='current_temp_c', field='x.com.samsung.da.items',
device_class='temperature',
state_class='measurement', unit_fn=_microwave_temp_unit,
value_fn=lambda items: int_or_none(
(items[0].get('x.com.samsung.da.current') if items else None))),
),
)
MICROWAVE_MODE = Capability(
href='/mode/vs/0',
poll_tier='warm',
entities=(
# SelectDesc first — test_microwave_mode_options_nonempty uses entities[0]
SelectDesc(key='cooking_mode', field='x.com.samsung.da.modes',
icon='mdi:tune',
options=_cooking_mode_options,
value_fn=lambda v: v[0] if v else None,
write_fn=_mode_write),
SwitchDesc(key='sound', field='x.com.samsung.da.options',
icon='mdi:volume-high',
entity_category='config',
value_fn=lambda opts: option_value(opts, 'Sound') == 'On',
write_fn=_sound_write),
SwitchDesc(key='lamp', field='x.com.samsung.da.options',
icon='mdi:track-light',
exists_fn=_lamp_exists,
value_fn=lambda opts: option_value(opts, 'Lamp') not in (None, 'Off'),
write_fn=_lamp_write),
# issue #181: Filter Reminder / End Signal Reminder toggles,
# confirmed present (both On and Off observed across dumps -- see
# issue #152's ME7500D fixtures) but only on boards that carry the
# FilterRemind_*/RemindBeep_* tokens; gated off elsewhere (e.g. the
# MW7300B combi dump has neither) rather than assumed universal.
SwitchDesc(key='filter_remind', field='x.com.samsung.da.options',
icon='mdi:air-filter',
entity_category='config',
exists_fn=_filter_remind_exists,
value_fn=lambda opts: option_value(opts, 'FilterRemind') == 'On',
write_fn=_filter_remind_write),
SwitchDesc(key='remind_beep', field='x.com.samsung.da.options',
icon='mdi:bell-ring',
entity_category='config',
exists_fn=_remind_beep_exists,
value_fn=lambda opts: option_value(opts, 'RemindBeep') == 'On',
write_fn=_remind_beep_write),
),
)
@@ -2,7 +2,8 @@
Shared by dryer/dishwasher/oven/washer families.
"""
from datetime import datetime, timezone, timedelta
import math
from datetime import datetime, timedelta, timezone
from ..capability import Capability
from ..entities import BinarySensorDesc, ButtonDesc, NumberDesc, SensorDesc
@@ -28,17 +29,41 @@ def _int(v):
return None
def _is_active(rep):
"""Check if appliance is actively running and cycle is not finished."""
return (
_SAMSUNG_STATE_TO_OCF.get(rep.get('x.com.samsung.da.state')) == 'active'
and rep.get('x.com.samsung.da.progress') != 'Finish'
)
def _remaining_seconds(raw):
"""'HH:MM:SS' (or 'MM:SS') -> total seconds, or None."""
if not isinstance(raw, str):
return None
try:
parts = [int(p) for p in raw.split(':')]
except (ValueError, TypeError):
return None
if len(parts) == 3:
h, m, s = parts
elif len(parts) == 2:
h, m, s = 0, *parts
else:
return None
return h * 3600 + m * 60 + s
def _delay_hours(v):
"""delayStartTime is a duration until the cycle starts, not a
wall-clock time -- "01:00" means "1 hour from when you press start",
not "1 AM"."""
if not v:
return 0.0
try:
h, m, s = v.split(':')
return int(h) + int(m) / 60 + int(s) / 3600
except Exception:
return None
total_seconds = _remaining_seconds(v)
if total_seconds is None:
return 0.0 if not v else None
return total_seconds / 3600.0
def _format_delay(hours):
@@ -53,27 +78,39 @@ def _delay_field(rep):
wall-clock time -- see _delay_hours). Write back whichever key the
device itself is using; default to delayStartTime for hardware that
reports neither yet (matches prior behavior)."""
return ('x.com.samsung.da.delayEndTime' if 'x.com.samsung.da.delayEndTime' in rep
else 'x.com.samsung.da.delayStartTime')
return (
'x.com.samsung.da.delayEndTime' if 'x.com.samsung.da.delayEndTime' in rep
else 'x.com.samsung.da.delayStartTime'
)
def _finish_time(remaining_str):
if not remaining_str:
def _finish_time(rep):
if not _is_active(rep):
return None
try:
h, m, s = remaining_str.split(':')
total_s = int(h) * 3600 + int(m) * 60 + int(s)
if total_s == 0:
return None
return datetime.now(timezone.utc) + timedelta(seconds=total_s)
except Exception:
total_s = _remaining_seconds(rep.get('x.com.samsung.da.remainingTime'))
if not total_s:
return None
return datetime.now(timezone.utc) + timedelta(seconds=total_s)
def _completion_minutes(rep):
"""Parse remaining time into minutes directly from device payload."""
raw = rep.get('x.com.samsung.da.remainingTime') or rep.get('remainingTime')
total_s = _remaining_seconds(raw)
if total_s is None:
return None
# Avoid the firmware bug where it freezes at 1 minute post-cycle
if rep.get('x.com.samsung.da.progress') == 'Finish':
return 0
return math.ceil(total_s / 60)
# Shared by dryer/dishwasher/oven/washer -- oven.py imports this directly
# rather than keeping its own copy, since both wrote the identical
# state='Ready' RMW.
STOP_BUTTON = ButtonDesc(key='stop', field='', name='Stop', payload='Ready',
STOP_BUTTON = ButtonDesc(key='stop', field='', payload='Ready',
icon='mdi:stop',
write_fn=lambda p, rep, href=None: (
['operational', 'state', 'vs', '0'],
@@ -84,46 +121,50 @@ OPERATIONAL_STATE = Capability(
poll_tier='hot',
entities=(
SensorDesc(key='machine_state', field='x.com.samsung.da.state',
name='Machine state', device_class='enum',
device_class='enum',
options=('idle', 'active', 'pause'),
translation_key='machine_state', value_fn=_to_ocf),
# cycle_active is a bool derived from machine_state; used by the
# adapter to gate oven writes (cycle_active_field='cycle_active').
# Harmless for non-oven appliances — just an extra bool in state.
# Samsung firmware keeps state='Run' after progress reaches 'Finish',
# so we also gate on progress to avoid a stuck 'Running' indication.
# Named 'Running' rather than 'Cycle active' -- this href (and the
# Named 'Running' in the catalog rather than 'Cycle active' -- this href (and the
# start/pause/stop buttons below) is shared across the dryer/
# dishwasher/oven/washer families, and 'cycle' is laundry-specific
# vocabulary that doesn't fit an oven's bake/roast/etc.
BinarySensorDesc(key='cycle_active', device_class='running',
name='Running',
rep_fn=lambda rep: (
_SAMSUNG_STATE_TO_OCF.get(rep.get('x.com.samsung.da.state')) == 'active'
and rep.get('x.com.samsung.da.progress') != 'Finish'
)),
SensorDesc(key='progress', name='Progress', icon='mdi:progress-wrench',
SensorDesc(key='progress', icon='mdi:progress-wrench',
rep_fn=lambda rep: (
'Idle' if _SAMSUNG_STATE_TO_OCF.get(rep.get('x.com.samsung.da.state')) != 'active'
else _progress(rep.get('x.com.samsung.da.progress'))
)),
SensorDesc(key='progress_percentage',
name='Progress percent', unit='%', state_class='measurement',
unit='%', state_class='measurement',
rep_fn=lambda rep: (
0 if _SAMSUNG_STATE_TO_OCF.get(rep.get('x.com.samsung.da.state')) != 'active'
else _int(rep.get('x.com.samsung.da.progressPercentage'))
)),
# Only show finish time when machine is actively running. Samsung
# firmware leaves a stale remainingTime after a cycle ends, and
# freezes it at '00:01:00' when progress reaches 'Finish'.
SensorDesc(key='finish_time', device_class='timestamp',
name='Estimated finish',
rep_fn=lambda rep: (
None if _SAMSUNG_STATE_TO_OCF.get(rep.get('x.com.samsung.da.state')) != 'active'
or rep.get('x.com.samsung.da.progress') == 'Finish'
else _finish_time(rep.get('x.com.samsung.da.remainingTime'))
)),
NumberDesc(key='delay_start_hours', name='Delay start', icon='mdi:timer-plus-outline',
rep_fn=_finish_time),
SensorDesc(key='completion_minutes',
icon='mdi:clock-outline', unit='min',
device_class='duration', state_class='measurement',
exists_fn=lambda rep, resources: _completion_minutes(rep) is not None,
rep_fn=_completion_minutes),
NumberDesc(key='delay_start_hours', icon='mdi:timer-plus-outline',
device_class='duration', unit='h',
native_min=0, native_max=24, step=1,
rep_fn=lambda rep: _delay_hours(
@@ -132,16 +173,17 @@ OPERATIONAL_STATE = Capability(
write_fn=lambda p, rep, href=None: (
['operational', 'state', 'vs', '0'],
{_delay_field(rep): _format_delay(p)})),
ButtonDesc(key='start', field='', name='Start', payload='Run',
ButtonDesc(key='start', field='', payload='Run',
icon='mdi:play',
write_fn=lambda p, rep, href=None: (
['operational', 'state', 'vs', '0'],
{'x.com.samsung.da.state': p})),
ButtonDesc(key='pause', field='', name='Pause', payload='Pause',
ButtonDesc(key='pause', field='', payload='Pause',
icon='mdi:pause',
write_fn=lambda p, rep, href=None: (
['operational', 'state', 'vs', '0'],
{'x.com.samsung.da.state': p})),
STOP_BUTTON,
),
)
@@ -51,6 +51,14 @@ SETPOINT_STEP_F = 5
# Mode options seen on NV7000BS-class. No dump exists so this list is inferred
# from Samsung documentation and firmware observations. The firmware will
# reject unknown modes; missing entries here are a coverage gap, not a bug.
#
# This is a fallback only, used when a device's own /mode/vs/0 doesn't report
# x.com.samsung.da.supportedModes at all -- see _oven_mode_options/
# _oven_mode_write below. issue #138's range dump (NE63A6511SS/AA) reports
# ConvectionRoast/KeepWarm/BreadProof/AirFryer/Dehydrate/SelfClean/SteamClean
# in its own supportedModes; those are read live rather than added here, per
# the adding-device-support skill's preference for device-reported option
# lists over hardcoded ones.
_OVEN_MODES = (
'NoOperation',
'Bake',
@@ -173,8 +181,20 @@ def _cook_time_write(p, rep, href=None):
}
def _oven_mode_options(resources):
"""Live mode list from the device's own /mode/vs/0 supportedModes when
it reports one; the NV7000BS-era _OVEN_MODES guess otherwise. Mirrors
laundry.py's options_field pattern (buzzer_sound/finish_sound), but
needs the callable form rather than options_field because a static
fallback has to kick in when the device's own field is absent."""
rep = resources.get('/mode/vs/0') or {}
live = rep.get('x.com.samsung.da.supportedModes')
return list(live) if live else list(_OVEN_MODES)
def _oven_mode_write(p, rep, href=None):
if p not in _OVEN_MODES:
valid = rep.get('x.com.samsung.da.supportedModes') or _OVEN_MODES
if p not in valid:
return None
return ['mode', 'vs', '0'], {'x.com.samsung.da.modes': [p]}
@@ -228,25 +248,25 @@ OVEN_OPERATIONAL_STATE = Capability(
poll_tier='hot',
entities=(
SensorDesc(key='machine_state', field='x.com.samsung.da.state',
name='Machine state', icon='mdi:stove',
icon='mdi:stove',
device_class='enum', options=('idle', 'active', 'pause'),
translation_key='machine_state', value_fn=_to_ocf),
BinarySensorDesc(key='cycle_active', field='x.com.samsung.da.state',
name='Running', device_class='running',
device_class='running',
value_fn=lambda v: _SAMSUNG_STATE_TO_OCF.get(v) == 'active'),
SensorDesc(key='progress_percentage',
field='x.com.samsung.da.progressPercentage',
name='Progress percent', unit='%', state_class='measurement',
unit='%', state_class='measurement',
value_fn=_int),
SensorDesc(key='operation_time_minutes',
field='x.com.samsung.da.operationTime',
name='Operation time (minutes)', unit='min',
unit='min',
state_class='measurement', value_fn=_op_minutes),
SensorDesc(key='finish_time', field='x.com.samsung.da.remainingTime',
name='Estimated finish', device_class='timestamp',
device_class='timestamp',
value_fn=_finish_time),
NumberDesc(key='cook_time', field='x.com.samsung.da.operationTime',
name='Cook time', unit='min', native_min=0, native_max=1439,
unit='min', native_min=0, native_max=1439,
step=1.0, icon='mdi:timer', value_fn=_op_minutes,
write_fn=_cook_time_write),
STOP_BUTTON,
@@ -258,7 +278,7 @@ OVEN_CAVITY = Capability(
poll_tier='hot',
entities=(
SensorDesc(key='oven_state', field='x.com.samsung.da.state',
name='Cavity state'),
),
),
)
@@ -291,7 +311,7 @@ OVEN_SETPOINT = Capability(
entities=(
# NumberDesc first — test_oven_setpoint_write_is_read_modify_write uses entities[0]
NumberDesc(key='oven_setpoint', field='x.com.samsung.da.items',
name='Setpoint', device_class='temperature', unit_fn=_oven_temp_unit,
device_class='temperature', unit_fn=_oven_temp_unit,
native_min=float(SETPOINT_MIN_C), native_max=float(SETPOINT_MAX_C),
step=float(SETPOINT_STEP_C), icon='mdi:thermometer-chevron-up',
native_min_fn=lambda rep: float(_setpoint_bounds(rep)[0]),
@@ -301,7 +321,7 @@ OVEN_SETPOINT = Capability(
(items[0].get('x.com.samsung.da.desired') if items else None)),
write_fn=_oven_setpoint_write),
SensorDesc(key='current_temp_c', field='x.com.samsung.da.items',
name='Temperature', device_class='temperature',
device_class='temperature',
state_class='measurement', unit_fn=_oven_temp_unit,
value_fn=lambda items: _int(
(items[0].get('x.com.samsung.da.current') if items else None))),
@@ -313,7 +333,7 @@ OVEN_DOOR = Capability(
poll_tier='hot',
entities=(
BinarySensorDesc(key='door_open', field='x.com.samsung.da.items',
name='Door', device_class='door',
device_class='door',
value_fn=lambda items: (
items[0].get('x.com.samsung.da.openState') == 'Open'
if items else None)),
@@ -325,7 +345,7 @@ OVEN_CONNECTED = Capability(
poll_tier='warm',
entities=(
BinarySensorDesc(key='cloud_connected', field='x.com.samsung.da.connected',
name='Cloud connected', device_class='connectivity',
device_class='connectivity',
entity_category='diagnostic',
value_fn=lambda v: v == 'On'),
),
@@ -338,31 +358,37 @@ OVEN_CONNECTED = Capability(
# fields worth exposing.
OVEN_SPEC = Capability(href='/oven/spec/vs/0')
# Quick-recipe display blob (combi microwave, issue #121) -- a JSON-encoded
# string (language/menu/servingSize/option) with every field blank on the
# only dump seen, and no documented write contract. No entity to bind per
# the 'don't guess' rule; a bare Capability still marks the href covered.
OVEN_RECIPE_COOK = Capability(href='/recipe/cook/vs/0')
OVEN_MODE = Capability(
href='/mode/vs/0',
poll_tier='warm',
entities=(
# SelectDesc first — test_oven_mode_options_nonempty uses entities[0]
SelectDesc(key='oven_mode', field='x.com.samsung.da.modes',
name='Cooking mode', icon='mdi:tune',
options=_OVEN_MODES,
icon='mdi:tune',
options=_oven_mode_options,
value_fn=lambda v: v[0] if v else None,
write_fn=_oven_mode_write),
SwitchDesc(key='lamp', field='x.com.samsung.da.options',
name='Lamp', icon='mdi:track-light',
icon='mdi:track-light',
value_fn=lambda opts: _option_value(opts, 'UpperLamp') == 'On',
write_fn=_lamp_write),
SwitchDesc(key='sound', field='x.com.samsung.da.options',
name='Sound', icon='mdi:volume-high',
icon='mdi:volume-high',
entity_category='config',
value_fn=lambda opts: _option_value(opts, 'Sound') == 'On',
write_fn=_sound_write),
SwitchDesc(key='fast_preheat', field='x.com.samsung.da.options',
name='Fast preheat', icon='mdi:fire',
icon='mdi:fire',
value_fn=lambda opts: _option_value(opts, 'fastpreheat') == 'On',
write_fn=_fastpreheat_write),
SwitchDesc(key='natural_steam', field='x.com.samsung.da.options',
name='Natural steam', icon='mdi:kettle-steam',
icon='mdi:kettle-steam',
value_fn=lambda opts: _option_value(opts, 'NaturalSteam') == 'On',
write_fn=_naturalsteam_write),
),
@@ -24,7 +24,8 @@ write pattern already proven safe elsewhere in this codebase (oven setpoint,
icemaker toggles).
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, SelectDesc, SensorDesc
from ..entities import BinarySensorDesc, SelectDesc, SensorDesc, SwitchDesc
from .common import normalize_temp_unit
# Observed as high as 4 (this issue's dump); user-reported hardware with 5
# burners exists. Kept a little above both since exists_fn gates unused
@@ -52,6 +53,10 @@ def _burner_hot_surface_fn(i):
return lambda burner_list: get_state(burner_list) not in (None, 'normal')
def _burner_pan_detection_fn(i):
return lambda burner_list: bool(_burner_field_fn(i, 'panDetection')(burner_list))
def _power_level_options(resources):
spec = resources.get('/cooktop/spec/vs/0') or {}
return list(spec.get('supportedPowerLevelList') or [])
@@ -81,28 +86,63 @@ def _burner_entities(i):
n = i + 1
return (
SelectDesc(key=f'burner_{i}_power_level', field='burnerList',
name=f'Burner {n} power level', icon='mdi:knob',
icon='mdi:knob',
translation_key='range_burner_power_level',
translation_placeholders={'number': str(n)},
options=_power_level_options,
exists_fn=exists,
value_fn=_burner_field_fn(i, 'powerLevel'),
write_fn=_burner_power_level_write(i)),
SensorDesc(key=f'burner_{i}_state', field='burnerList',
name=f'Burner {n} state', icon='mdi:stove',
icon='mdi:stove',
translation_key='burner_state',
translation_placeholders={'number': str(n)},
exists_fn=exists,
value_fn=_burner_field_fn(i, 'operationState')),
BinarySensorDesc(key=f'burner_{i}_hot_surface', field='burnerList',
name=f'Burner {n} hot surface', device_class='heat',
device_class='heat',
translation_key='burner_hot_surface',
translation_placeholders={'number': str(n)},
exists_fn=exists,
value_fn=_burner_hot_surface_fn(i)),
BinarySensorDesc(key=f'burner_{i}_pan_detected', field='burnerList',
icon='mdi:pot',
translation_key='burner_pan_detected',
translation_placeholders={'number': str(n)},
entity_category='diagnostic',
exists_fn=exists,
value_fn=_burner_pan_detection_fn(i)),
)
def _child_lock_write(p, rep, href=None):
if p not in ('On', 'Off'):
return None
return ['cooktop', 'status', 'vs', '0'], {'childLock': p.lower()}
COOKTOP_STATUS = Capability(
href='/cooktop/status/vs/0',
poll_tier='hot',
entities=(
SensorDesc(key='cooktop_state', field='operationState',
name='Cooktop state', icon='mdi:pot-steam'),
icon='mdi:pot-steam'),
# The cooktop section's own on/off (issue #86) -- distinct from
# common.POWER's /power/0 or /power/vs/0, which some boards in this
# family (the range combo) additionally carry for the whole
# appliance. Read-only: no live device to confirm remotely turning
# a cooktop on wouldn't leave a burner active unattended.
BinarySensorDesc(key='cooktop_power', field='power',
device_class='power', icon='mdi:pot-steam',
value_fn=lambda v: str(v).lower() == 'on'),
# Safe to write -- a lock toggle, not a heat control -- via a
# direct single-field PUT (no RMW needed; unlike burnerList this
# is a lone scalar, not an array of siblings to preserve).
SwitchDesc(key='cooktop_child_lock', field='childLock',
device_class='lock', entity_category='config',
icon='mdi:lock',
value_fn=lambda v: str(v).lower() == 'on',
write_fn=_child_lock_write),
*[e for i in range(MAX_BURNERS) for e in _burner_entities(i)],
),
)
@@ -123,8 +163,50 @@ COOKTOP_SAFETY = Capability(
poll_tier='warm',
entities=(
BinarySensorDesc(key='cooktop_safety_shutoff_enabled', field='safetyAlert',
name='Hot surface auto-shutoff enabled',
entity_category='config',
value_fn=lambda v: (v or {}).get('state') == 'on'),
),
)
# Bluetooth meat probe (issue #86). All-idle sentinel values when
# disconnected (operationBurnerNumber -1, temperatures 0) -- no special
# gating on those, matching cooktop.PAIRED_HOOD_STATUS's own precedent of
# showing a disconnected accessory's fields plainly rather than hiding the
# whole capability.
PROBE_STATUS = Capability(
href='/bluetooth/probe/status/vs/0',
poll_tier='warm',
entities=(
BinarySensorDesc(key='probe_connected', field='connectionState',
device_class='connectivity',
value_fn=lambda v: str(v).lower() == 'connected'),
SensorDesc(key='probe_battery', field='batteryPercentage',
device_class='battery', state_class='measurement',
unit='%', entity_category='diagnostic'),
SensorDesc(key='probe_temperature', field='currentTemperature',
device_class='temperature', state_class='measurement',
unit_fn=lambda rep: normalize_temp_unit(rep.get('temperatureUnit'), '°C')),
SensorDesc(key='probe_target_temperature', field='targetTemperature',
device_class='temperature', entity_category='diagnostic',
unit_fn=lambda rep: normalize_temp_unit(rep.get('temperatureUnit'), '°C')),
),
)
# Some range boards (issue #74's NE63B8411SS) report no /cooktop/status/vs/0
# burner array at all -- their local API only exposes this coarse
# monitoring resource for the cooktop half, with no per-burner detail.
# Meaning of `cooktopMonitoring` (a bare "0" on the only dump seen) and
# `warmingCenterState`'s full value set aren't confirmed, so both are
# exposed as plain sensors rather than guessed at as a switch/select --
# `supportedHoodLampStateList` has no corresponding live-state field on
# this resource, so nothing to bind it to yet.
COOKTOP_MONITORING = Capability(
href='/cooktopmonitoring/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='cooktop_running_state', field='x.com.samsung.da.cooktopRunningState',
icon='mdi:pot-steam-outline'),
SensorDesc(key='warming_center_state', field='x.com.samsung.da.warmingCenterState',
icon='mdi:heat-wave', entity_category='diagnostic'),
),
)
@@ -9,9 +9,11 @@ independent fields.
from datetime import datetime, timezone
from ..batch import is_stub_rep
from ..capability import Capability
from ..entities import (
BinarySensorDesc,
ButtonDesc,
FanDesc,
SelectDesc,
SensorDesc,
@@ -52,7 +54,6 @@ HOOD_ALARMS = Capability(
SensorDesc(
key='alarm_code',
field='x.com.samsung.da.items',
name='Alarm code',
icon='mdi:alert',
entity_category='diagnostic',
value_fn=_active_alarm_codes,
@@ -93,15 +94,18 @@ HOOD_FAN = Capability(
FanDesc(
key='fan',
field='x.com.samsung.da.hood.fanSpeed',
name=None,
write_fn=_hood_fan_write,
),
BinarySensorDesc(
key='automatic_operation',
field='x.com.samsung.da.hood.autoOperation',
name='Automatic operation',
icon='mdi:fan-auto',
entity_category='diagnostic',
# Absent on the microwave family's built-in vent fan (issue
# #137) -- this board has no auto-ventilation mode, unlike the
# standalone range hood this capability was written for.
exists_fn=lambda rep, resources: (
is_stub_rep(rep) or 'x.com.samsung.da.hood.autoOperation' in rep),
value_fn=lambda value: str(value).lower() == 'on',
),
),
@@ -125,7 +129,6 @@ HOOD_LAMP = Capability(
SwitchDesc(
key='lamp',
field='x.com.samsung.lamp.power',
name='Lamp',
icon='mdi:range-hood',
value_fn=lambda value: str(value).lower() == 'on',
write_fn=lambda payload, rep, href=None: (
@@ -136,7 +139,6 @@ HOOD_LAMP = Capability(
SelectDesc(
key='lamp_brightness',
field='x.com.samsung.lamp.current',
name='Lamp brightness',
icon='mdi:brightness-6',
translation_key='range_hood_lamp_brightness',
options_field='x.com.samsung.lamp.range',
@@ -153,7 +155,6 @@ HOOD_FILTER = Capability(
SensorDesc(
key='hood_filter_usage',
field='x.com.samsung.da.filterUsage',
name='Filter usage',
unit='%',
state_class='measurement',
icon='mdi:air-filter',
@@ -163,14 +164,18 @@ HOOD_FILTER = Capability(
SensorDesc(
key='hood_filter_status',
field='x.com.samsung.da.filterStatus',
name='Filter status',
icon='mdi:air-filter',
entity_category='diagnostic',
device_class='enum',
options=('normal', 'wash', 'replace'),
translation_key='filter_status',
value_fn=lambda value: (
value.lower() if isinstance(value, str) else value
),
),
SensorDesc(
key='hood_filter_capacity',
field='x.com.samsung.da.filterCapacity',
name='Filter capacity',
unit='h',
icon='mdi:timer-outline',
entity_category='diagnostic',
@@ -181,6 +186,50 @@ HOOD_FILTER = Capability(
)
# After Run (issue #147): the hood keeps the fan running at low speed for a
# while after it's switched off, to clear residual cooking smoke -- a
# feature a user actively watches and cancels, not passive diagnostics, so
# none of the three entities below carry entity_category. No
# supported-values list is advertised for activationState, so it's modeled
# read-only (monitoring, not an invented "enable" write) per the 'don't
# guess' rule; runningCancel's only observed value is the command name
# itself ('Cancel'), the same self-describing command-field shape as
# operational.STOP_BUTTON. runningProgress's own name states its domain
# (a percentage of the cycle completed), so it's modeled as one rather than
# left an opaque passthrough -- unlike activationState/runningCancel, there's
# no ambiguous field name or missing-write-contract question here to hedge on.
AFTER_RUN = Capability(
href='/afterrun/vs/0',
poll_tier='warm',
entities=(
BinarySensorDesc(
key='after_run_active',
field='x.com.samsung.da.activationState',
icon='mdi:fan-clock',
value_fn=lambda value: str(value).lower() == 'on',
),
SensorDesc(
key='after_run_progress',
field='x.com.samsung.da.runningProgress',
unit='%',
state_class='measurement',
icon='mdi:fan-clock',
value_fn=int_or_none,
),
ButtonDesc(
key='after_run_cancel',
field='',
payload='Cancel',
icon='mdi:fan-off',
write_fn=lambda p, rep, href=None: (
['afterrun', 'vs', '0'],
{'x.com.samsung.da.runningCancel': p},
),
),
),
)
AIR_QUALITY = Capability(
href='/sensors/vs/0',
poll_tier='warm',
@@ -188,26 +237,22 @@ AIR_QUALITY = Capability(
SensorDesc(
key='clean_level',
field='x.com.samsung.da.items',
name='Clean level',
icon='mdi:air-filter',
value_fn=lambda items: sensor_item_value(items, 'CleanLevel'),
),
SensorDesc(
key='dust',
field='x.com.samsung.da.items',
name='Dust',
value_fn=lambda items: sensor_item_value(items, 'Dust'),
),
SensorDesc(
key='fine_dust',
field='x.com.samsung.da.items',
name='Fine dust',
value_fn=lambda items: sensor_item_value(items, 'FineDust'),
),
SensorDesc(
key='super_fine_dust',
field='x.com.samsung.da.items',
name='Super fine dust',
value_fn=lambda items: sensor_item_value(items, 'SuperFineDust'),
),
),
@@ -221,7 +266,6 @@ AIR_LEVEL_CHECK = Capability(
BinarySensorDesc(
key='periodic_air_sensing',
field='x.com.samsung.da.periodicSensingActivationState',
name='Periodic air sensing',
icon='mdi:radar',
entity_category='diagnostic',
value_fn=lambda value: str(value).lower() == 'on',
@@ -229,14 +273,12 @@ AIR_LEVEL_CHECK = Capability(
SensorDesc(
key='air_sensing_state',
field='x.com.samsung.da.sensingState',
name='Air sensing state',
icon='mdi:radar',
entity_category='diagnostic',
),
SensorDesc(
key='last_air_sensing_time',
field='x.com.samsung.da.lastSensingTime',
name='Last air sensing time',
device_class='timestamp',
entity_category='diagnostic',
value_fn=_timestamp,
@@ -244,14 +286,12 @@ AIR_LEVEL_CHECK = Capability(
SensorDesc(
key='last_air_sensing_level',
field='x.com.samsung.da.lastSensingLevel',
name='Last air sensing level',
icon='mdi:air-filter',
entity_category='diagnostic',
),
SensorDesc(
key='automatic_ventilation_state',
field='x.com.samsung.da.autoExeState',
name='Automatic ventilation state',
icon='mdi:fan-auto',
entity_category='diagnostic',
),
@@ -266,7 +306,6 @@ AUTO_VENTILATION = Capability(
SensorDesc(
key='auto_ventilation_action',
field='action',
name='Auto ventilation action',
icon='mdi:fan-auto',
),
),
@@ -0,0 +1,109 @@
"""Capabilities for the Samsung stick-vacuum clean/auto-empty station
(model A-VSKR-TP1-22-VS9500AL, "Bespoke Jet" clean station, issue #131).
The reporter's diagnostics dump shows no vacuum-body state at all (no
suction level, no battery, no cleaning-mode/room-mapping control, no
docked/undocked status even) -- only the clean station's own dustbag,
dustbin auto-empty settings, and UV-C sanitizing-cycle status. This
strongly suggests the WiFi/DTLS module lives in the station, not the
handheld stick: the station is the only "device" this integration's local
API can see, and the wand's own controls are unrelated hardware not
reachable this way. Modeled as its own device type -- these hrefs don't
overlap with any existing family, so there's no shared-href ambiguity to
resolve against another type (see registry/by_type/__init__.py's
docstring for that rule).
Resources verified against the issue #131 diagnostics dump.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, SelectDesc, SensorDesc, SwitchDesc
from .common import int_or_none, parse_iso_utc as _parse_iso_utc
DUSTBAG = Capability(
href='/component/station/dustbag/vs/0',
poll_tier='warm',
entities=(
BinarySensorDesc(key='dustbag_full', field='x.com.samsung.da.status',
device_class='problem',
icon='mdi:bag-personal',
value_fn=lambda v: v == 'full'),
),
)
# dustbagUsage/dustbagPrevUsage are raw counters with no capacity/resolution
# field alongside them to normalize into a percentage (unlike the AC/range
# families' filterUsage, which always ships filterCapacity) -- exposed as a
# plain diagnostic count rather than guessing a unit.
DUSTBAG_USAGE = Capability(
href='/component/station/dustbagusage/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='dustbag_usage', field='x.com.samsung.da.dustbagUsage',
icon='mdi:counter', entity_category='diagnostic',
state_class='total_increasing', value_fn=int_or_none),
),
)
DUSTBIN_SETTING = Capability(
href='/setting/dustbin/vs/0',
poll_tier='warm',
entities=(
SwitchDesc(key='auto_empty', field='x.com.samsung.da.autoEmpty',
icon='mdi:delete-empty',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['setting', 'dustbin', 'vs', '0'],
{'x.com.samsung.da.autoEmpty': 'On' if p == 'On' else 'Off'})),
SwitchDesc(key='dustbin_auto_close', field='x.com.samsung.da.autoClose',
icon='mdi:door-sliding',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['setting', 'dustbin', 'vs', '0'],
{'x.com.samsung.da.autoClose': 'On' if p == 'On' else 'Off'})),
SelectDesc(key='discharging_time', field='x.com.samsung.da.desiredDischargingTime',
icon='mdi:timer-outline',
entity_category='config',
options_field='x.com.samsung.da.supportedDischargingTime',
write_fn=lambda p, rep, href=None: (
['setting', 'dustbin', 'vs', '0'],
{'x.com.samsung.da.desiredDischargingTime': p})),
),
)
# stickStatus's exact meaning (docked? powered? charging?) isn't confirmed
# from this single On/Off dump -- exposed as a plain diagnostic sensor
# rather than a binary_sensor, so no polarity/semantic is asserted that
# might be wrong.
CLEANSTATION_STATUS = Capability(
href='/status/cleanstation/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='cleanstation_status', field='x.com.samsung.da.status',
icon='mdi:home-lightning-bolt', entity_category='diagnostic'),
SensorDesc(key='stick_status', field='x.com.samsung.da.stickStatus',
icon='mdi:broom', entity_category='diagnostic'),
SwitchDesc(key='uvc_intensive_mode', field='x.com.samsung.da.uvcIntensive',
icon='mdi:lightbulb-on-outline',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['status', 'cleanstation', 'vs', '0'],
{'x.com.samsung.da.uvcIntensive': 'On' if p == 'On' else 'Off'})),
SensorDesc(key='uvc_operation_time', field='x.com.samsung.da.uvcOperationTime',
icon='mdi:timer-sand', entity_category='diagnostic',
value_fn=int_or_none),
SensorDesc(key='uvc_total_operation_time',
field='x.com.samsung.da.uvcTotalOperationTime',
icon='mdi:timer-sand', entity_category='diagnostic',
state_class='total_increasing', value_fn=int_or_none),
SensorDesc(key='uvc_finished_time', field='x.com.samsung.da.uvcFinishedTime',
device_class='timestamp', entity_category='diagnostic',
value_fn=_parse_iso_utc),
SensorDesc(key='uvc_emitted_time', field='x.com.samsung.da.emittedTime',
device_class='timestamp', entity_category='diagnostic',
value_fn=_parse_iso_utc),
),
)
@@ -2,9 +2,10 @@
front-load washers).
Resources verified against two live WW90DG6U25LEU4 dumps (Table_02 course
family). Washers never report `oneUiVersion` -- see
`registry/by_type/__init__.py`'s `for_device_by_model()` for the fallback
detection this device type requires.
family). Washers share the `DA_WM_` laundry board with dryers, so their
`modelNum` can't tell the two apart -- see `registry/by_type/__init__.py`'s
`_CONSUMER_PREFIX_TO_KEY` for the `description`-based detection this device
type requires.
The shared laundry surface -- power/kids-lock/remote-control OCF+vendor
fallback pairs, buzzer, energy meter, job-beginning-status, and the
@@ -23,8 +24,8 @@ from .laundry import (
)
# ---------------------------------------------------------------------------
# Course_XX hex codes. 23 of the codes named in strings.json/translations
# under entity.select.washer_cycle.state.<id, lowercased> were captured
# Course_XX hex codes. 23 of the codes named in translations/en.json
# under entity.select.washer_cycle_table_02.state.<id, lowercased> were captured
# from a live WW90DG6U25LEU4's x.com.samsung.da.editCourseList
# (EditCourseList_1C1D211B1E29243328262722202325322F2E30662D8F96), matched
# positionally against a Slovak-UI user's screenshots of their app's course
@@ -45,6 +46,14 @@ from .laundry import (
# (issue #22). Combo units carry their own course set, so these codes
# don't imply anything about '1F' on a plain washer.
#
# Three more -- '52' Eco Cold, '54' Towels, '60' Self Clean+ -- came from a
# WF50A8600AV/US, verified directly rather than by inference: the reporter
# selected each cycle on the physical appliance and read back the resulting
# raw code from the cycle_select entity's state (issue #80). '54' shares a
# display name with the existing '24' Towels -- a different code on a
# different course table legitimately landing on the same label, not a typo
# (same pattern as '21'/'65' Colors and '27'/'5E' Rinse+Spin above).
#
# No static fallback list of those codes is kept here, deliberately: other
# washer models have a different actual course set (a second dump's active
# course, '65', isn't even in the list above; models with 'AI Wash'/'Mixed
@@ -75,19 +84,19 @@ WASHER_SETTINGS = Capability(
href='/washer/vs/0',
entities=(
SelectDesc(key='wash_temperature', field='x.com.samsung.da.waterTemperature',
name='Wash temperature', icon='mdi:thermometer-water',
icon='mdi:thermometer-water',
entity_category='config',
options_field='x.com.samsung.da.supportedWaterTemperature',
write_fn=lambda p, rep, href=None: (
['washer', 'vs', '0'], {'x.com.samsung.da.waterTemperature': p})),
SelectDesc(key='spin_speed', field='x.com.samsung.da.spinLevel',
name='Spin speed', icon='mdi:sync',
icon='mdi:sync',
entity_category='config',
options_field='x.com.samsung.da.supportedSpinLevel',
write_fn=lambda p, rep, href=None: (
['washer', 'vs', '0'], {'x.com.samsung.da.spinLevel': p})),
SelectDesc(key='rinse_cycles', field='x.com.samsung.da.rinseCycles',
name='Rinse cycles', icon='mdi:water-sync',
icon='mdi:water-sync',
entity_category='config',
options_field='x.com.samsung.da.supportedRinseCycles',
write_fn=lambda p, rep, href=None: (
@@ -97,7 +106,7 @@ WASHER_SETTINGS = Capability(
# #22. Self-gates off on plain washers, which never report
# supportedDryLevel.
SelectDesc(key='dry_level', field='x.com.samsung.da.dryLevel',
name='Dry level', icon='mdi:tumble-dryer',
icon='mdi:tumble-dryer',
entity_category='config',
translation_key='washer_dry_level',
options_field='x.com.samsung.da.supportedDryLevel',
@@ -157,8 +166,8 @@ def _drum_clean_last_cleaned(rep):
# valid raw codes for its field, same hex-pair shape as EditCourseList.
# '<Prefix>Alarm_<On/Off>' is a low-reservoir warning flag.
#
# Label mapping (entity.select.washer_dosing_quantity/washer_detergent_
# water_hardness/washer_softener_concentration in strings.json) is an
# Label mapping (entity.select.{detergent,softener}_quantity /
# detergent_water_hardness / softener_concentration in translations/en.json) is an
# assumed, not cross-device-verified, reading of the single issue #9 dump +
# screenshots: LevelCtrl's 4 codes as None/Low/Medium/High (00 has no
# on-screen equivalent -- the app's Quantité picker only offers
@@ -259,7 +268,7 @@ def _dosing_low(prefix):
# auto-release-dry toggles -- only this per-course gating is washer-only, so
# it stays here rather than in laundry.py (see laundry.bool_option_switch's
# docstring: it takes a prebuilt validate_fn and has no opinion on it).
def _bool_option_switch(key, name, icon, prefix, availability_field):
def _bool_option_switch(key, icon, prefix, availability_field):
def validate(p, rep, resources):
"""Reject turning on when the selected course's byte in
`availability_field` isn't 'F0'. Turning off is never blocked. Falls
@@ -281,11 +290,11 @@ def _bool_option_switch(key, name, icon, prefix, availability_field):
if len(pairs) != len(courses):
return None
if pairs[courses.index(current)] != 'F0':
return f"{name} isn't available on the selected cycle."
return f"{key}_unavailable_for_cycle"
return None
return bool_option_switch(
key, name, icon, prefix,
key, icon, prefix,
entity_category='config', gate_on_presence=True, validate_fn=validate)
@@ -294,63 +303,61 @@ WASHER_COURSE = Capability(
entities=(
cycle_select(translation_key='washer_cycle', icon='mdi:washing-machine',
table_href='/st/washercourse/vs/0'),
SensorDesc(key='drum_clean_cycles_remaining', name='Drum clean due in',
icon='mdi:washing-machine-alert', unit='cycles',
SensorDesc(key='drum_clean_cycles_remaining', unit='cycles',
icon='mdi:washing-machine-alert',
state_class='measurement',
exists_fn=lambda rep, resources: _drum_clean_cycles_remaining(rep) is not None,
rep_fn=_drum_clean_cycles_remaining),
SensorDesc(key='drum_clean_last_cleaned', name='Drum last cleaned',
icon='mdi:calendar-clock', device_class='timestamp',
SensorDesc(key='drum_clean_last_cleaned', device_class='timestamp',
icon='mdi:calendar-clock',
entity_category='diagnostic',
exists_fn=lambda rep, resources: _drum_clean_last_cleaned(rep) is not None,
rep_fn=_drum_clean_last_cleaned),
SelectDesc(key='detergent_quantity', name='Detergent quantity', icon='mdi:cup-water',
translation_key='washer_dosing_quantity',
SelectDesc(key='detergent_quantity', icon='mdi:cup-water',
translation_key='detergent_quantity',
entity_category='config',
options=_level_options('DetergentLevelCtrl'),
exists_fn=lambda rep, resources: bool(
_level_options('DetergentLevelCtrl')(resources)),
rep_fn=_dosing_level('DetergentLevelCtrl'),
write_fn=_level_write('DetergentLevelCtrl')),
SelectDesc(key='detergent_water_hardness', name='Detergent water hardness',
icon='mdi:water-opacity',
translation_key='washer_detergent_water_hardness',
SelectDesc(key='detergent_water_hardness', icon='mdi:water-opacity',
translation_key='detergent_water_hardness',
entity_category='config',
options=_level_options('DetergentLevel2Ctrl'),
exists_fn=lambda rep, resources: bool(
_level_options('DetergentLevel2Ctrl')(resources)),
rep_fn=_dosing_level('DetergentLevel2Ctrl'),
write_fn=_level_write('DetergentLevel2Ctrl')),
SelectDesc(key='softener_quantity', name='Softener quantity', icon='mdi:flask-outline',
translation_key='washer_dosing_quantity',
SelectDesc(key='softener_quantity', icon='mdi:flask-outline',
translation_key='softener_quantity',
entity_category='config',
options=_level_options('SoftenerLevelCtrl'),
exists_fn=lambda rep, resources: bool(
_level_options('SoftenerLevelCtrl')(resources)),
rep_fn=_dosing_level('SoftenerLevelCtrl'),
write_fn=_level_write('SoftenerLevelCtrl')),
SelectDesc(key='softener_concentration', name='Softener concentration',
icon='mdi:flask-plus-outline',
translation_key='washer_softener_concentration',
SelectDesc(key='softener_concentration', icon='mdi:flask-plus-outline',
translation_key='softener_concentration',
entity_category='config',
options=_level_options('SoftenerLevel2Ctrl'),
exists_fn=lambda rep, resources: bool(
_level_options('SoftenerLevel2Ctrl')(resources)),
rep_fn=_dosing_level('SoftenerLevel2Ctrl'),
write_fn=_level_write('SoftenerLevel2Ctrl')),
BinarySensorDesc(key='detergent_low', name='Detergent low',
icon='mdi:alert-circle-outline', device_class='problem',
BinarySensorDesc(key='detergent_low', device_class='problem',
icon='mdi:alert-circle-outline',
exists_fn=bool_option_exists('DetergentAlarm'),
rep_fn=_dosing_low('DetergentAlarm')),
BinarySensorDesc(key='softener_low', name='Softener low',
icon='mdi:alert-circle-outline', device_class='problem',
BinarySensorDesc(key='softener_low', device_class='problem',
icon='mdi:alert-circle-outline',
exists_fn=bool_option_exists('SoftenerAlarm'),
rep_fn=_dosing_low('SoftenerAlarm')),
_bool_option_switch('bubble_soak', 'Bubble soak', 'mdi:chart-bubble',
_bool_option_switch('bubble_soak', 'mdi:chart-bubble',
'BubbleSoak', 'BubbleSoakSet'),
_bool_option_switch('pre_wash', 'Pre wash', 'mdi:washing-machine',
_bool_option_switch('pre_wash', 'mdi:washing-machine',
'PreWashSetting', 'PreWashAvailableSet'),
_bool_option_switch('intensive', 'Intensive', 'mdi:washing-machine',
_bool_option_switch('intensive', 'mdi:washing-machine',
'IntensiveSetting', 'IntensiveAvailableSet'),
),
)
@@ -0,0 +1,256 @@
"""Capabilities for the Samsung water-purifier family (TP2X_WATERPURIFIER-class,
issue #90, model TP2X_WATERPURIFIER_20K).
Resources verified against the issue #90 diagnostics dump.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc
from .common import int_or_none, parse_iso_utc as _parse_iso_utc
DISPENSE = Capability(
href='/setting/waterpurifier/vs/0',
poll_tier='warm',
entities=(
SelectDesc(key='dispense_type', field='x.com.samsung.da.desiredType',
icon='mdi:cup-water',
options_field='x.com.samsung.da.supportedTypes',
write_fn=lambda p, rep, href=None: (
['setting', 'waterpurifier', 'vs', '0'],
{'x.com.samsung.da.desiredType': p})),
# Only a handful of discrete temperatures are selectable (not a
# continuous range) -- a select over the live-reported set, not a
# number with invented bounds.
SelectDesc(key='hot_water_temperature', field='x.com.samsung.da.tempDesiredHotWater',
icon='mdi:thermometer',
entity_category='config',
options_field='x.com.samsung.da.supportedHotTemperatures',
write_fn=lambda p, rep, href=None: (
['setting', 'waterpurifier', 'vs', '0'],
{'x.com.samsung.da.tempDesiredHotWater': p})),
# Bounds and step come live from the device's own
# desiredCapacityRange/capacityResolution fields, not a hardcoded
# constant -- see the adding-device-support skill's "never hard-code
# the one dump's values" section. No unit is set: capacityUnit reads
# "C" on this dump, which can't be right for a volume field, so per
# the 'don't guess' rule the unit is left unset rather than assumed
# to be mL.
NumberDesc(key='dispense_capacity', field='x.com.samsung.da.desiredCapacity',
icon='mdi:cup-water',
value_fn=int_or_none,
range_field='x.com.samsung.da.desiredCapacityRange',
step_fn=lambda rep: int_or_none(
rep.get('x.com.samsung.da.capacityResolution')) or 1,
write_fn=lambda p, rep, href=None: (
['setting', 'waterpurifier', 'vs', '0'],
{'x.com.samsung.da.desiredCapacity': str(int(round(float(p))))})),
BinarySensorDesc(key='pouring', field='x.com.samsung.da.pourStatus',
icon='mdi:cup-water',
value_fn=lambda v: v == 'On'),
),
)
STATUS = Capability(
href='/status/waterpurifier/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='waterpurifier_status', field='x.com.samsung.da.status',
icon='mdi:water-pump',
entity_category='diagnostic'),
BinarySensorDesc(key='filter_door_status', field='x.com.samsung.da.filterDoorStatus',
device_class='door',
entity_category='diagnostic',
value_fn=lambda v: v == 'Open'),
SensorDesc(key='sterilize_period', field='x.com.samsung.da.sterilizePeriod',
icon='mdi:calendar-sync',
entity_category='diagnostic'),
SensorDesc(key='sterilize_run_time', field='x.com.samsung.da.sterilizeRunTime',
icon='mdi:timer-outline',
entity_category='diagnostic'),
SensorDesc(key='sterilize_last_time', device_class='timestamp',
entity_category='diagnostic',
rep_fn=lambda rep: _parse_iso_utc(
rep.get('x.com.samsung.da.sterilizeLastTime'))),
SensorDesc(key='sterilize_plan_time', device_class='timestamp',
entity_category='diagnostic',
rep_fn=lambda rep: _parse_iso_utc(
rep.get('x.com.samsung.da.sterilizePlanTime'))),
SensorDesc(key='filter_clean_remain_time', field='x.com.samsung.da.filterCleanRemainTime',
icon='mdi:timer-sand',
entity_category='diagnostic'),
),
)
FAVORITE_CAPACITY = Capability(
href='/favorite/capacity/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='favorite_capacity_enabled', field='x.com.samsung.da.switchCapacity',
icon='mdi:star-outline',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['favorite', 'capacity', 'vs', '0'],
{'x.com.samsung.da.switchCapacity': 'On' if p == 'On' else 'Off'})),
SelectDesc(key='favorite_capacity', field='x.com.samsung.da.defaultCapacity',
icon='mdi:cup-water',
entity_category='config',
options_field='x.com.samsung.da.capacityList',
write_fn=lambda p, rep, href=None: (
['favorite', 'capacity', 'vs', '0'],
{'x.com.samsung.da.defaultCapacity': p})),
),
)
# Coffee-capable variant (issue #107) -- a "favorite" supported-list select
# for the hot water dispensed alongside brewing, same shape as
# FAVORITE_CAPACITY above.
def _status_lock_definitely_lacks_hotwater_field(resources: dict) -> bool:
"""Three-way read of /status/lock/vs/0's hotwaterLock field, favouring
LOCK.hotwater_lock (the primary descriptor) whenever the outcome is
still ambiguous:
- href entirely absent from this device -> definitely no clash, the
switchHotwater fallback below may claim the entity.
- href present but an unfetched stub ({}) -> outcome pending, *not* a
confirmed absence. LOCK's own exists_fn optimistically includes itself
through a stub (matching entity.py's default), so returning True here
too would register both descriptors -- as SwitchDescs sharing one key,
with identical unique_ids -- until the next poll resolves it.
- href present and fetched -> the real answer."""
rep = resources.get('/status/lock/vs/0')
if rep is None:
return True
if not rep:
return False
return 'x.com.samsung.da.hotwaterLock' not in rep
FAVORITE_HOTWATER = Capability(
href='/favorite/hotwater/vs/0',
poll_tier='cold',
entities=(
# Despite the resource/field naming, switchHotwater's value domain is
# Locked/Unlocked, not an enable flag (issue #144) -- it's the same
# hot-water lock as LOCK.hotwater_lock below, just surfaced through
# this href on boards that don't populate /status/lock/vs/0's
# hotwaterLock field. Shares that descriptor's key so only one "Hot
# water lock" entity ever appears.
#
# Both halves of this fallback pair need an exists_fn, not just this
# one: adapter.flatten() (the coordinator.data source every entity's
# is_on reads) only ever honours exists_fn, never entity.py's
# implicit "require own field present" default that gates plain
# registration. Two same-keyed descriptors with only one of them
# gated still both land in flatten()'s output dict -- whichever is
# processed last silently wins, decided by device-reported href
# order, not by which one is actually correct. So this exists_fn
# also re-asserts its own field's presence (switchHotwater), the
# gate a bare `field=` used to get for free before it had to share a
# key with LOCK's descriptor.
SwitchDesc(key='hotwater_lock', field='x.com.samsung.da.switchHotwater',
device_class='lock',
entity_category='config',
value_fn=lambda v: v != 'Unlocked',
exists_fn=lambda rep, resources: (
'x.com.samsung.da.switchHotwater' in rep
and _status_lock_definitely_lacks_hotwater_field(resources)),
write_fn=lambda p, rep, href=None: (
['favorite', 'hotwater', 'vs', '0'],
{'x.com.samsung.da.switchHotwater': 'Locked' if p == 'On' else 'Unlocked'})),
SelectDesc(key='favorite_hotwater_temperature',
field='x.com.samsung.da.favorite.defaultTemperature',
icon='mdi:thermometer',
entity_category='config',
options_field='x.com.samsung.da.favorite.supportedList',
write_fn=lambda p, rep, href=None: (
['favorite', 'hotwater', 'vs', '0'],
{'x.com.samsung.da.favorite.defaultTemperature': p})),
),
)
# Coffee-capable variant (issue #107). No 'x.com.samsung.da.' field prefix
# on this resource, unlike the rest of the water-purifier surface.
COFFEE = Capability(
href='/favorite/coffee/vs/0',
poll_tier='warm',
entities=(
SwitchDesc(key='favorite_coffee_enabled', field='favorite.activate',
icon='mdi:coffee-outline',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['favorite', 'coffee', 'vs', '0'],
{'favorite.activate': 'On' if p == 'On' else 'Off'})),
SensorDesc(key='coffee_brew_status', field='brew.status',
icon='mdi:coffee-outline',
entity_category='diagnostic'),
),
)
LOCK = Capability(
href='/status/lock/vs/0',
poll_tier='warm',
entities=(
# Shares its key with FAVORITE_HOTWATER's switchHotwater fallback
# above (issue #144); see the comment there for why this half also
# needs an explicit exists_fn now that the two share a key in
# adapter.flatten()'s output. A stub rep ({}) still counts as
# "present" here (matches entity.py's own default for a field-less
# gate) since the alternative -- treating an unfetched resource as
# confirmed-absent -- is what let both descriptors register at once.
SwitchDesc(key='hotwater_lock', field='x.com.samsung.da.hotwaterLock',
device_class='lock',
entity_category='config',
value_fn=lambda v: v != 'Unlocked',
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.hotwaterLock' in rep),
write_fn=lambda p, rep, href=None: (
['status', 'lock', 'vs', '0'],
{'x.com.samsung.da.hotwaterLock': 'Locked' if p == 'On' else 'Unlocked'})),
SwitchDesc(key='coldwater_lock', field='x.com.samsung.da.coldwaterLock',
device_class='lock',
entity_category='config',
value_fn=lambda v: v != 'Unlocked',
write_fn=lambda p, rep, href=None: (
['status', 'lock', 'vs', '0'],
{'x.com.samsung.da.coldwaterLock': 'Locked' if p == 'On' else 'Unlocked'})),
SwitchDesc(key='buzz_lock', field='x.com.samsung.da.buzzLock',
device_class='lock',
entity_category='config',
value_fn=lambda v: v != 'Unlocked',
write_fn=lambda p, rep, href=None: (
['status', 'lock', 'vs', '0'],
{'x.com.samsung.da.buzzLock': 'Locked' if p == 'On' else 'Unlocked'})),
),
)
# ---------------------------------------------------------------------------
# Water-purifier-scoped coverage: hrefs with no user-actionable state or no
# confirmed contract, following the 'don't guess' rule.
# ---------------------------------------------------------------------------
_WP_IGNORED = [
# supportedModes carries a single opaque wizard-workflow token
# ('HOMECARE_WIZARD_V2') and modes reports a completely different,
# unrelated value ('WATERFILTER_DISABLE') not even present in
# supportedModes -- internal plumbing, not a real user-facing mode
# select. OCF-standard /mode/0 mirrors the same vendor resource but is
# already covered by the global ignored.IGNORED (fridge's OCF-native
# vacation-mode flag shares that href).
'/mode/vs/0',
# Static support-flags blob (automation.supported.modes/options) -- no
# live "current automation setting" field to expose.
'/automation/waterpurifier/vs/0',
# Coffee-capable variant (issue #107). All four are static
# capability-advertisement blobs or empty -- no live "current recipe" /
# "current custom slot" field to expose, unlike /favorite/coffee/vs/0
# (COFFEE above), which does carry live brew status.
'/brand/recipe/info/vs/0', # revision + max-brand-count metadata
'/coffee/custom/recipe/vs/0', # publisher.support: allowed custom-recipe slot IDs
'/recipe/coffee/vs/0', # same publisher.support shape, no per-recipe content
'/recipe/coffee/deletion/vs/0', # empty {} on this dump
]
COVERAGE = [Capability(href=h) for h in _WP_IGNORED]
@@ -32,7 +32,7 @@ class BoundEntity:
def _snake_to_title(s: str) -> str:
"""'CUBED_ICE'/'cubed_ice' -> 'Cubed Ice'. Shared with entity.py's
_derive_name, which applies the same transform to a state key."""
_derive_name, which applies the same transform to an href-derived key."""
return s.replace('_', ' ').title()
@@ -73,7 +73,15 @@ def discover(
registry: dict[str, list[Capability]],
pattern_caps: Iterable[Capability] = (),
log: Optional[Callable[[str], None]] = None,
tier_log: Optional[Callable[[str, str], None]] = None,
) -> list[BoundEntity]:
"""`tier_log(href, poll_tier)` fires for every href a capability actually
matches, even a no-entity "coverage-only" capability (see COVERAGE lists
in capabilities/*.py) that `_bind()` turns into zero `BoundEntity` rows.
Callers that need a href's poll cadence (the coordinator's hot/warm
sub-poll and OBSERVE-attempt lists) must use this, not `bound` -- a
coverage-only capability's `poll_tier` would otherwise be silently
dropped since it never appears in `bound`."""
out: list[BoundEntity] = []
for href, rep in resources.items():
@@ -91,6 +99,8 @@ def discover(
inst = instance_suffix(href)
out.extend(_bind(cap, href, inst, _instance_name(cap, rep)))
matched = True
if tier_log is not None:
tier_log(href, cap.poll_tier)
if matched:
continue
@@ -109,6 +119,8 @@ def discover(
segs = [s for s in src.strip('/').split('/') if s and not s.isdigit() and s != 'vs']
out.extend(_bind(cap, href, inst, _instance_name(cap, rep), '_'.join(segs)))
matched = True
if tier_log is not None:
tier_log(href, cap.poll_tier)
break
if not matched and not caps and log is not None:
@@ -8,14 +8,14 @@ where a description declares one.
"""
from __future__ import annotations
from dataclasses import dataclass, field
from typing import Any, Callable, Optional
from dataclasses import dataclass
from typing import Any, Callable, Mapping, Optional
WriteFn = Optional[Callable[[Any, dict], "tuple[list[str], dict] | None"]]
# (payload, rep, resources) -> a human-readable rejection message, or None to
# allow the write. resources is the coordinator's full href->rep snapshot, for
# the same cross-resource lookups exists_fn needs (e.g. reading a sibling
# href's live option list).
# (payload, rep, resources) -> a translation key, or None to allow the
# write. resources is the coordinator's full href->rep snapshot, for the same
# cross-resource lookups exists_fn needs (e.g. reading a sibling href's live
# option list).
ValidateFn = Optional[Callable[[Any, dict, dict], "str | None"]]
@@ -27,13 +27,18 @@ def _identity(v: Any) -> Any:
class SamsungEntityDescription:
key: str
field: str = ''
name: Optional[str] = None
# Defaults to `key`: entity names and states live in translations/, never
# here, so a descriptor only sets this to share one catalog entry across
# several descriptors, or to point at a differently-named one.
translation_key: Any = None # str | Callable[[dict[str, dict]], Optional[str]]
# callable form receives the coordinator's full href->rep resource
# snapshot and returns the key to use (or None for no translation this
# device) -- for a descriptor shared across board generations whose
# state-code meaning isn't guaranteed consistent between them; see
# laundry.cycle_select's table-id-gated resolver.
# snapshot and returns the key to use -- for a descriptor shared across
# board generations whose state-code meaning isn't guaranteed consistent
# between them; see laundry.cycle_select's table-id-gated resolver.
translation_placeholders: Optional[Mapping[str, str]] = None
# Dynamic resources such as fridge compartments and ice makers use a
# device-provided or href-derived instance label inside a translated name.
use_instance_name: bool = False
icon: Optional[str] = None
entity_category: Optional[str] = None # 'diagnostic' | 'config' | None
enabled_default: bool = True
@@ -1,7 +1,7 @@
"""Read device identity from standard OCF resources (/oic/p, /oic/d)."""
from __future__ import annotations
from dataclasses import dataclass
from dataclasses import dataclass, field
from typing import Optional
import cbor2
@@ -13,6 +13,8 @@ class DeviceIdentity:
model: str
name: str
serial: Optional[str]
device_types: tuple[str, ...] = ()
raw: dict[str, dict] = field(default_factory=dict)
def _get(sess, path) -> dict:
@@ -26,6 +28,27 @@ def _get(sess, path) -> dict:
return {}
def _device_types(d: dict) -> tuple[str, ...]:
"""/oic/d's `rt` -- the device's own OCF device-type declaration.
In OCF this is the one standardized "what am I" field: alongside the
generic 'oic.wk.d' it carries a concrete type such as 'oic.d.airconditioner'
or a Samsung 'x.com.samsung.da.*' equivalent. Nothing routes on it yet --
device-type detection currently parses board part numbers out of
/information/vs/0's modelNum instead (see registry/by_type/__init__.py) --
because no captured dump has ever included it: /device/0 batch responses
don't carry /oic/d, and diagnostics didn't report it. It's surfaced in
diagnostics so incoming issue reports can tell us whether real hardware
populates it usefully enough to route on.
"""
rt = d.get('rt')
if isinstance(rt, str):
rt = [rt]
if not isinstance(rt, (list, tuple)):
return ()
return tuple(t for t in rt if isinstance(t, str))
def read_identity(sess, serial: Optional[str]) -> DeviceIdentity:
p = _get(sess, ['oic', 'p'])
d = _get(sess, ['oic', 'd'])
@@ -34,4 +57,9 @@ def read_identity(sess, serial: Optional[str]) -> DeviceIdentity:
model=p.get('mnmo') or '',
name=d.get('n') or '',
serial=serial,
device_types=_device_types(d),
# Kept whole rather than field-by-field: these resources are outside
# the /device/0 dump diagnostics already captures, and we don't yet
# know which of their fields will turn out to identify a device type.
raw={'/oic/p': p, '/oic/d': d},
)
@@ -19,9 +19,26 @@ _SENSITIVE_SUBSTRINGS = (
'userid', 'deviceid', 'uuid', 'duid', 'password', 'secret',
)
# Matched whole, not as substrings. OCF's /oic/d and /oic/p identify the unit
# with bare one- and two-letter keys that the rules above cannot see, being
# far too short to match on -- 'di' alone is a substring of 'condition',
# 'display', 'dispenser' and plenty of other ordinary appliance fields:
#
# 'di' -- device UUID, 'pi' -- platform UUID. As identifying as the serial
# number above.
# 'n' -- /oic/d's device name. Free text the owner can set from the
# SmartThings app, so it may well carry a person's name. Nothing
# in the /device/0 dump has ever exposed it; it only became
# reachable when diagnostics started reporting /oic/d, and the
# device-type signal we actually want from that resource is `rt`,
# which is not redacted.
_SENSITIVE_EXACT = frozenset({'di', 'pi', 'n'})
def _is_sensitive_key(key: str) -> bool:
lowered = key.lower()
if lowered in _SENSITIVE_EXACT:
return True
return any(s in lowered for s in _SENSITIVE_SUBSTRINGS)
+29 -4
View File
@@ -11,6 +11,7 @@ from homeassistant.helpers.entity_platform import AddEntitiesCallback
from .registry.entities import SelectDesc
from .catalog import translated_states
from .const import DOMAIN
from .coordinator import LocalThingsCoordinator
from .entity import LocalThingsEntity, _is_included
@@ -32,6 +33,22 @@ async def async_setup_entry(
_CAMEL_BOUNDARY_RE = re.compile(r'(?<=[a-z0-9])(?=[A-Z])')
def _translation_state(value: str, known: frozenset[str]) -> str | None:
"""Return the catalog state `value` normalizes to, else None.
Samsung reports options in whatever casing the resource uses
('Rinse_Hold', 'SpTtypeBeerDrinks', '1b'); Home Assistant looks state
translations up by a lowercase key. Only values the catalog actually
knows are normalized -- an unrecognized (or future) vendor value keeps
its own readable form rather than becoming an untranslatable slug.
"""
direct = value.lower().replace(' ', '_')
if direct in known:
return direct
snake = _CAMEL_BOUNDARY_RE.sub('_', value).lower().replace(' ', '_')
return snake if snake in known else None
def _display(value, translation_key: Optional[str]):
"""Turn a raw device option/state value into what's shown in the UI.
@@ -40,13 +57,13 @@ def _display(value, translation_key: Optional[str]):
callers pass the resolved value, e.g. self.translation_key, not
the raw descriptor field).
An entity with a translation_key looks its state up in strings.json,
and hassfest requires those keys to be lowercase -- so those values
An entity with a translation_key looks its state up in the shipped
translation catalog, whose state keys are lowercase -- so those values
must be lowercased exactly to match, and the device still expects
that same raw casing back on write (callers map the displayed value
back to raw via _raw_options()).
Everything else has no strings.json lookup, so there's no reason to
Everything else has no catalog lookup, so there's no reason to
destroy the device's own casing. Only two cosmetic fixups apply: a
fully lowercase device-native token (e.g. "voice") is title-cased,
and a PascalCase token (e.g. "ExtraHigh") gets a space inserted at
@@ -57,7 +74,15 @@ def _display(value, translation_key: Optional[str]):
if not isinstance(value, str):
return value
if translation_key:
return value.lower()
known = translated_states('select', translation_key)
if not known:
# No state table for this key: either the entity isn't translated
# at all, or its name is translated but its options deliberately
# aren't (an unrecognized course table, say). Either way the
# opaque device value is the best thing to show.
return value
if translated := _translation_state(value, known):
return translated
if value.islower():
return value.replace('_', ' ').title()
return _CAMEL_BOUNDARY_RE.sub(' ', value)
-1
View File
@@ -61,7 +61,6 @@ class LocalThingsConnectionModeSensor(CoordinatorEntity[LocalThingsCoordinator],
Disabled by default — it's for troubleshooting, not everyday use."""
_attr_has_entity_name = True
_attr_name = 'Connection mode'
_attr_translation_key = 'connection_mode'
_attr_entity_category = EntityCategory.DIAGNOSTIC
_attr_entity_registry_enabled_default = False
-302
View File
@@ -1,302 +0,0 @@
{
"entity": {
"select": {
"door_alert": {
"state": {
"1": "Alarm 1",
"2": "Alarm 2",
"3": "Alarm 3",
"4": "Alarm 4"
}
},
"brightness_level": {
"state": {
"33": "Low",
"66": "Medium",
"100": "High"
}
},
"range_hood_lamp_brightness": {
"state": {
"1": "Level 1",
"2": "Level 2"
}
},
"ice_type": {
"state": {
"off": "Off",
"whiskey_iceball_3": "3 Balls/Day",
"whiskey_iceball_6": "6 Balls/Day",
"whiskey_iceball_9": "9 Balls/Day"
}
},
"beverage_zone_mode": {
"state": {
"sp_ttype_beer_drinks": "Beverage",
"sp_ttype_wine_dessert": "Wine and Dessert"
}
},
"pantry_zone_mode": {
"state": {
"fdr_wine": "Wine",
"fdr_deli": "Deli",
"fdr_drinks": "Drinks"
}
},
"flex_zone_mode": {
"state": {
"cv_ttype_rf9000a_freeze": "Freeze",
"cv_ttype_rf9000a_softfreeze": "Soft Freeze",
"cv_ttype_rf9000a_meat_fish": "Meat/Fish",
"cv_ttype_rf9000a_fruit_veggies": "Fruit & Veggies",
"cv_ttype_rf9000a_beverage": "Beverage",
"cv_fdr_wine": "Wine",
"cv_fdr_deli": "Deli",
"cv_fdr_beverage": "Beverage",
"cv_fdr_meat": "Meat",
"cv_fdr_soft_freezer": "Soft Freezer"
}
},
"dishwasher_cycle": {
"state": {
"0e": "AI Wash",
"07": "Pre blast",
"90": "Self clean",
"86": "Normal",
"83": "Express 60",
"84": "Heavy",
"8d": "Pots and pans",
"80": "Delicate",
"8e": "Plastic",
"8f": "Baby Care"
}
},
"washer_cycle_table_02": {
"state": {
"1c": "Eco 40-60",
"1d": "Super Speed",
"21": "Colours",
"1b": "Cotton",
"1e": "15' Quick Wash",
"29": "Drum Clean+",
"24": "Towels",
"33": "Bedding",
"28": "Drain/Spin",
"26": "Delicates",
"27": "Rinse+Spin",
"22": "Wool",
"20": "Hygiene Steam",
"23": "Outdoor",
"25": "Synthetics",
"32": "Shirts",
"2f": "Activewear",
"2e": "Baby Care",
"30": "Cloudy Day",
"66": "Denim",
"2d": "Silent Wash",
"8f": "Intense Cold",
"96": "Less Microfiber",
"36": "Wash+Dry",
"37": "Air Wash",
"38": "Cotton Dry",
"39": "Synthetics Dry",
"1f": "Intense Cold"
}
},
"dryer_cycle_table_03": {
"state": {
"16": "Cotton",
"18": "Synthetics",
"19": "Delicates",
"1a": "Wool",
"1b": "Bedding",
"1c": "Shirts",
"1d": "Towels",
"1e": "Outdoor",
"1f": "Mixed Load",
"20": "Iron Dry",
"23": "Quick Dry 35",
"24": "Cool Air",
"25": "Warm Air",
"27": "Time Dry"
}
},
"washer_dosing_quantity": {
"state": {
"00": "None",
"01": "Low",
"02": "Medium",
"03": "High"
}
},
"washer_detergent_water_hardness": {
"state": {
"01": "Soft",
"02": "Medium",
"03": "Hard"
}
},
"washer_softener_concentration": {
"state": {
"01": "1x",
"02": "2x",
"03": "3x"
}
},
"washer_dry_level": {
"state": {
"none": "Off",
"cupboard": "Cupboard",
"30": "30 min",
"60": "1 hr",
"90": "1 hr 30",
"120": "2 hr",
"180": "3 hr",
"240": "4 hr"
}
}
},
"sensor": {
"ice_making_status": {
"state": {
"icestatus_stop": "Idle",
"icestatus_run": "Making ice"
}
},
"connection_mode": {
"state": {
"observe": "Push (observe)",
"poll": "Polling"
}
},
"machine_state": {
"state": {
"idle": "Idle",
"active": "Active",
"pause": "Paused"
}
},
"air_filter_status": {
"state": {
"normal": "Normal",
"wash": "Wash",
"replace": "Replace"
}
}
},
"climate": {
"airconditioner": {
"state_attributes": {
"fan_mode": {
"state": {
"auto": "Auto",
"low": "Low",
"medium": "Medium",
"high": "High",
"turbo": "Turbo"
}
},
"swing_mode": {
"state": {
"off": "Fixed",
"both": "All directions",
"vertical": "Up and down"
}
},
"preset_mode": {
"state": {
"none": "Off",
"sleep": "Sleep",
"quiet": "Quiet",
"smart": "Smart",
"speed": "Speed"
}
}
}
}
}
},
"config": {
"step": {
"user": {
"title": "Add Samsung Appliance",
"description": "Enter the IP address of your Samsung appliance and the AC14K_M CA credentials used to mint device certificates. {reuse_note}",
"data": {
"host": "IP Address",
"ca_cert_pem": "CA Certificate (PEM)",
"ca_key_pem": "CA Private Key (PEM)"
},
"data_description": {
"host": "Local IP address of your Samsung appliance (e.g. 192.168.1.50).",
"ca_cert_pem": "The PEM-encoded AC14K_M CA certificate chain. Paste the full contents of your fullchain PEM including all BEGIN/END CERTIFICATE blocks.",
"ca_key_pem": "The PEM-encoded AC14K_M private key. Paste the full contents including the BEGIN/END PRIVATE KEY header and footer."
}
},
"confirm_unknown_type": {
"title": "Appliance type not recognized",
"description": "This appliance reported oneUiVersion \"{one_ui_version}\", which isn't a recognized type. It'll still be added, but only with common capabilities (power, alarms, etc. where present) rather than the full set for its family. You can help add full support afterward by downloading diagnostics for this device (Settings > Devices & Services > this device > the menu > Download diagnostics) and filing them in a new issue. Submit to add it anyway."
}
},
"error": {
"cannot_connect": "Cannot connect to the device. Verify the IP address is reachable and the CA credentials are correct.",
"invalid_ca": "The CA certificate or private key could not be loaded. Verify the PEM contents are correct and the key matches the certificate.",
"unknown": "Unexpected error. Check the Home Assistant logs for details."
},
"abort": {
"already_configured": "This device is already configured."
}
},
"options": {
"step": {
"init": {
"title": "Local Things Options",
"menu_options": {
"settings": "Remote control write settings",
"debug_write": "Debug: write to a resource"
}
},
"settings": {
"title": "Remote control write settings",
"description": "Some devices accept certain writes (e.g. default detergent/softener dosing on a washer) even while reporting remote control off. By default, LocalThings blocks every write with a clear error whenever a device reports remote control off, rather than letting the device silently reject it. Only enable this if you've confirmed writes actually work on this device with remote control off -- otherwise you'll trade that clear error for a silent failure.",
"data": {
"bypass_remote_control_lock": "Allow writes even when remote control is reported off"
}
},
"debug_write": {
"title": "Debug: write to a resource",
"description": "Power-user tool for pinning down device-specific write behavior. Pick the resource (href) you want to write to, or type a custom one that isn't listed. This bypasses the remote-control-off block and sends exactly the fields you provide -- it can misconfigure your appliance, so use it deliberately.",
"data": {
"href": "Resource href"
}
},
"debug_edit": {
"title": "Debug write: {href}",
"description": "Current value of `{href}`:\n```\n{current_value}\n```\nEnter ONLY the field(s) you want to change below. What you enter is sent to the device as-is (a partial update); it is NOT merged with the fields shown above, so don't paste the whole value back. Mind the types: a numeric string like \"1\" must stay quoted -- a bare 1 is sent as an integer, which some devices reject.",
"data": {
"payload": "Payload to write"
}
},
"debug_result": {
"title": "Debug write result",
"description": "The device returned CoAP code {code}. A 2.xx class means the write was accepted; 4.xx/5.xx means it was rejected. The resource now reads:\n```\n{new_value}\n```\nIf the value is unchanged, the device likely dropped the write. Pick what to do next:",
"menu_options": {
"debug_write": "Write another resource",
"finish": "Finish"
}
}
},
"error": {
"empty_payload": "Enter at least one field to write.",
"write_failed": "The write failed. Check the Home Assistant logs for details."
},
"abort": {
"not_loaded": "This device isn't connected yet. Try again once it has loaded."
}
},
"issues": {
"device_gap": {
"title": "Incomplete capability coverage for {device_name}",
"description": "This device is missing full capability coverage. Either its appliance type wasn't recognized, or some of the resources it exposes aren't modeled yet. It'll keep working with whatever is already supported. You can help expand support by going to Settings > Devices & Services > {device_name} > the menu (top right) > Download diagnostics, then filing it with the linked issue template."
}
}
}
File diff suppressed because it is too large Load Diff
File diff suppressed because it is too large Load Diff
+3
View File
@@ -1,2 +1,5 @@
[project]
requires-python = ">=3.13"
[tool.pytest.ini_options]
asyncio_mode = "auto"
+3 -2
View File
@@ -1,6 +1,7 @@
# Test harness — pulls in home-assistant, pytest, and pytest-socket at the
# matching versions. Current Home Assistant requires Python >= 3.14; pip will
# resolve the newest home-assistant your interpreter supports.
# matching versions. pip resolves the newest home-assistant your interpreter
# supports: Python 3.13 gets 0.13.316 (the floor below), 3.14 gets newer. On
# 3.12 or older nothing resolves and the whole install fails.
pytest-homeassistant-custom-component>=0.13.316
# Integration runtime deps, needed to import the component under test
+15
View File
@@ -41,3 +41,18 @@ def fridge_resources() -> dict[str, dict]:
@pytest.fixture
def washer_resources() -> dict[str, dict]:
return _load_device('washer')
@pytest.fixture
def all_device_fixtures() -> dict[str, dict[str, dict]]:
"""Every scrubbed device dump, keyed by fixture name.
For invariants that must hold across the whole corpus rather than for one
device -- so a newly added dump exercises them automatically.
"""
return {
path.name[:-len('_device.json')]: _resources_from_dump(
json.loads(path.read_text())
)
for path in sorted(FIXTURES.glob('*_device.json'))
}
+209
View File
@@ -0,0 +1,209 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.countryCode": "VN"
}
},
{
"href": "/course/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.options": [
"DeviceType_015E",
"UpdateAllow_NotAllowed",
"Course_01",
"SteamPush_None",
"SeamlessControl_Disable",
"KidsLockBypass_On",
"WashingTimes_58",
"DrumCleanProposal_30",
"SpecialFunction_4",
"AvailableDelayTime_0",
"ProgressTimeSet_AA01E0AC00B4B20690",
"WrinklePreventRunning_Off",
"SendToDevice_Off",
"GMT_12",
"Alarm_Off",
"SilentSet_0F0FF0F0F0F0F0F0F0F00F0F0F0FF0F0F00FF0",
"Silent_Off",
"WrinklePreventSet_0F0F0F0F0F0F0F0FF0F00F0F0F0F0F0F0F0FF0",
"DelayEndSet_0F0F0F0FF00F0F0F0F0F0F0F0F0F0F0F0F0F0F",
"OneTimeCourse_761F00200000000000000000000000",
"DownloadCourseList_090A0B12100C140D0F",
"EnergyLevelSet_0502020104030204050405020303010302010305",
"MostUsed_01",
"UsagesDB_ok",
"EnergyKW_396",
"DrumCleanLog_2024-01-01T00:00:00",
"TimeSync_NotSupported"
],
"x.com.samsung.da.supportedOptions": [
"001020403051A1B1C0708"
]
}
},
{
"href": "/cycleinterface/vs/0",
"rep": {}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.instantaneousPower": "-500",
"x.com.samsung.da.cumulativePower": "78200",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.cumulativeDate": "1785272400",
"x.com.samsung.da.cumulativeDateUTC": "1785240000"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "DA_DF_A51_20_COMMON|20261441|3801010200131100020100FF00000000",
"x.com.samsung.da.description": "DA_DF_A51_20_COMMON_DF8600T/DC92-02656A_0018",
"x.com.samsung.da.serialNum": "REDACTED",
"x.com.samsung.da.otnDUID": "REDACTED",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "DA_DF_A51_20_COMMON|20261441|3801010200131100020100FF00000000",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02672A230710(E431)",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "DA_DF_A51_20_COMMON",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "20060507,20072702",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/kidslock/0",
"rep": {
"value": false
}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/operational/state/0",
"rep": {
"currentMachineState": "REDACTED",
"machineStates": "REDACTED",
"jobStates": [
"None",
"Steaming",
"Airwashing",
"Drying",
"Finish"
],
"currentJobState": "None",
"remainingTime": "00:39:00",
"progressPercentage": "1"
}
},
{
"href": "/operational/state/vs/0",
"rep": {
"x.com.samsung.da.state": "Ready",
"x.com.samsung.da.remainingTime": "00:39:00",
"x.com.samsung.da.progressPercentage": "1",
"x.com.samsung.da.progress": "None",
"x.com.samsung.da.delayEndTime": "00:00:00",
"x.com.samsung.da.supportedProgress": [
"None",
"Steaming",
"Airwashing",
"Drying",
"Finish"
]
}
},
{
"href": "/power/0",
"rep": {
"value": true
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "10",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/remotectrl/0",
"rep": {
"value": false
}
},
{
"href": "/remotectrl/vs/0",
"rep": {
"x.com.samsung.da.remoteControlEnabled": "false"
}
},
{
"href": "/washer/vs/0",
"rep": {
"x.com.samsung.da.wrinklePrevent": "Off"
}
},
{
"href": "/wm/jobbeginingstatus/vs/0",
"rep": {}
}
]
}
+282
View File
@@ -0,0 +1,282 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/airdresseroption/sanitize/vs/0",
"rep": {
"x.com.samsung.da.sanitize": "Off",
"x.com.samsung.da.supportedSanitize": [
"On",
"Off"
]
}
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "3171000000",
"x.com.samsung.da.countryCode": "KR"
}
},
{
"href": "/course/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.options": [
"DeviceType_015E",
"UpdateAllow_NotAllowed",
"Course_22",
"AiOption_On",
"SteamPush_None",
"SeamlessControl_Disable",
"KidsLockBypass_On",
"FilterUsage_384019D5",
"WashingTimes_6",
"DrumCleanProposal_30",
"ProgressTimeSet_AA01A4AC00F0B20690",
"WrinklePreventRunning_Off",
"SendToDevice_Off",
"WeatherPush_Off",
"GMT_12",
"Alarm_Off",
"WrinklePreventSet_0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0FF00F0F0F0F0F0F0F0F0F0F0FF0F0",
"DelayEndSet_0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0FF0F0F00F0F0FF0F0F0F0F00F0F",
"EnergyLevelSet_0502010102010202030303010401040505050503030502040503030303030405",
"UsagesDB_ok",
"DrumCleanLog_2023-04-02T08:08:55|2023-10-02T03:38:19|2024-05-26T03:25:41|2024-10-01T01:07:20|2026-06-16T02:23:29"
],
"x.com.samsung.da.supportedOptions": [
"12261062361020E61020961021261020C61021E61020B61021061020A61061461021361061661022462062562062F62062062040F62042761023061021561021A61021B61021C61022A61022B61022C61022D61022E6102076102086102"
]
}
},
{
"href": "/cycleinterface/vs/0",
"rep": {
"x.com.samsung.da.cycleInterfaceEnabled": "Off"
}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "-500",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePower": "63600",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.cumulativeDate": "1784404800",
"x.com.samsung.da.cumulativeDateUTC": "1784372400"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "DA_DF_TP2_20_COMMON|20286141|380101010015110F0201000100010000",
"x.com.samsung.da.description": "DA_DF_TP2_20_COMMON_DF9500A/DC92-02888A_0002",
"x.com.samsung.da.serialNum": "REDACTED",
"x.com.samsung.da.otnDUID": "REDACTED",
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "A00",
"x.com.samsung.da.diagMinVersion": "1.0",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "DA_DF_TP2_20_COMMON|20286141|380101010015110F0201000100010000",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02673A250416(F822)",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Firmware_1_DB",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "21020115,23030652",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Firmware_2_DB",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "19111852,FFFFFFFF"
}
]
}
},
{
"href": "/kidslock/0",
"rep": {
"value": false
}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/operational/state/0",
"rep": {
"currentMachineState": "REDACTED",
"machineStates": "REDACTED",
"jobStates": [
"None",
"Steaming",
"Airwashing",
"Drying",
"Finish"
],
"currentJobState": "None",
"remainingTime": "00:39:00",
"progressPercentage": "1"
}
},
{
"href": "/operational/state/vs/0",
"rep": {
"x.com.samsung.da.state": "Ready",
"x.com.samsung.da.remainingTime": "00:39:00",
"x.com.samsung.da.progressPercentage": "1",
"x.com.samsung.da.progress": "None",
"x.com.samsung.da.delayEndTime": "00:00:00",
"x.com.samsung.da.supportedProgress": [
"None",
"Steaming",
"Airwashing",
"Drying",
"Finish"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "Micom",
"x.com.samsung.da.newVersionAvailable": "false"
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/remotectrl/0",
"rep": {
"value": false
}
},
{
"href": "/remotectrl/vs/0",
"rep": {
"x.com.samsung.da.remoteControlEnabled": "false"
}
},
{
"href": "/st/airdressercourse/vs/0",
"rep": {
"x.com.samsung.da.st.airdresserMode": "Table_00_Course_22",
"x.com.samsung.da.st.courseTable": "Table_00"
}
},
{
"href": "/washer/vs/0",
"rep": {
"x.com.samsung.da.wrinklePrevent": "Off"
}
},
{
"href": "/wm/editcourse/vs/0",
"rep": {
"x.com.samsung.da.editCourseList": "EditCourseList_22230C10252F0F0E09121E0B0A14131624202730151A1B1C2A2B2C2D2E0708",
"x.com.samsung.da.fixedCourseList": "FixedCourseList_22270F"
}
},
{
"href": "/wm/jobbeginingstatus/vs/0",
"rep": {}
},
{
"href": "/wm/personalcourse/vs/0",
"rep": {
"x.com.samsung.da.courses": [
"F1_00",
"F2_00",
"F3_00",
"F4_00",
"F5_00",
"F6_00",
"F7_00",
"F8_00",
"F9_00",
"FA_00"
],
"x.com.samsung.da.maxCourseNum": "10"
}
},
{
"href": "/wm/setinfo/vs/0",
"rep": {
"x.com.samsung.da.isModelSettingWithoutSC": "false",
"x.com.samsung.da.aiCourse": "false",
"x.com.samsung.da.isModelSettingPowerOnOff": "true"
}
},
{
"href": "/wm/welcomemsg/vs/0",
"rep": {}
}
]
}
+466
View File
@@ -0,0 +1,466 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/airlevelcheck/vs/0",
"rep": {
"x.com.samsung.da.sensingState": "NonProcessing",
"x.com.samsung.da.lastSensingTime": "1785157841",
"x.com.samsung.da.lastSensingLevel": "Kr1",
"x.com.samsung.da.periodicSensingSkipStatus": "Off",
"x.com.samsung.da.periodicSensingSkipTime": "00000000",
"x.com.samsung.da.periodicSensingActivationState": "On",
"x.com.samsung.da.autoExeState": "Off",
"x.com.samsung.da.supportedAutoExeState": [
"Off",
"Airpurify",
"Alarm"
],
"x.com.samsung.da.startSensingOnce": "Off"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-27T13:18:51",
"x.com.samsung.da.state": "Deleted"
}
],
"rt": [
"x.com.samsung.da.alarms"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "3B000100000A0000000000000000",
"x.com.samsung.da.id": "VTL",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "2650000000",
"x.com.samsung.da.airconOptionList": [
"AI_PURIFY",
"WELCOMECARE",
"DR"
]
}
},
{
"href": "/da/softreset/vs/0",
"rep": {
"x.com.samsung.da.softwarereset": "false"
}
},
{
"href": "/devicespecificinfo/vs/0",
"rep": {
"x.com.samsung.da.deviceActive": true
}
},
{
"href": "/display/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/dnd/autosleep/vs/0",
"rep": {
"x.com.samsung.da.visible": "true",
"x.com.samsung.da.startTime": "00:00:00",
"x.com.samsung.da.endTime": "00:00:00",
"x.com.samsung.da.useTimeSetting": "false",
"x.com.samsung.da.functionState": "false"
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.start": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.durationminutes": "0",
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativeDate": "1785158301",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativePower": "32428",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePowerType": "total"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/hepafilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "70",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterCapacity": "8760",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable"
],
"x.com.samsung.da.filterStatus": "normal"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.modelNum": "TP1X_DA-AC-AIR-01031_0000|10268241|70000721001813CC4D1A490301082100",
"x.com.samsung.da.description": "TP1X_DA-AC-AIR-01031_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02660A260401",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.newVersionAvailable": "0",
"x.com.samsung.da.number": "02682A25042102,02683A25031801"
}
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AP2",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 1
}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/light/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.modes": [
"Smart"
],
"x.com.samsung.da.supportedModes": [
"Smart",
"Max",
"Mid",
"WindFree",
"Sleep"
],
"x.com.samsung.da.options": [
"OptionCode_23418",
"SmartSleep_Off",
"WelcomeCare_On",
"Pollution_Off",
"ProtectOperation_Off",
"UpdateAllow_NotAllowed"
],
"rt": [
"x.com.samsung.da.mode"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/panel/vs/0",
"rep": {
"status": "Close"
}
},
{
"href": "/personality/presence/vs/0",
"rep": {}
},
{
"href": "/petfilteractivation/vs/0",
"rep": {
"status": "Off"
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On",
"operationNumber": "36",
"displayCondition": "Enable"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "true",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "3F00000000000000000000",
"x.com.samsung.da.id": "VTL",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/sensors/vs/0",
"rep": {
"x.com.samsung.da.cleanLevel": "1",
"x.com.samsung.da.total": "5",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Sensor for CleanLevel",
"x.com.samsung.da.type": "CleanLevel",
"x.com.samsung.da.value": [
"1"
]
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Sensor for Odor",
"x.com.samsung.da.type": "Odor",
"x.com.samsung.da.value": [
"1"
]
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Sensor for Dust",
"x.com.samsung.da.type": "Dust",
"x.com.samsung.da.value": [
"5",
"1"
]
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Sensor for FineDust",
"x.com.samsung.da.type": "FineDust",
"x.com.samsung.da.value": [
"5",
"1"
]
},
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Sensor for SuperFineDust",
"x.com.samsung.da.type": "SuperFineDust",
"x.com.samsung.da.value": [
"5",
"1"
]
}
],
"rt": [
"x.com.samsung.da.sensors"
],
"if": [
"oic.if.baseline",
"oic.if.s"
]
}
},
{
"href": "/settings/sound/mode/vs/0",
"rep": {
"mode": "mute",
"supportedModes": [
"mute",
"buzzer"
]
}
},
{
"href": "/settings/sound/output/vs/0",
"rep": {
"deviceType": "buzzer"
}
},
{
"href": "/settings/sound/volume/vs/0",
"rep": {
"level": "0",
"minLevel": "0",
"maxLevel": "3",
"resolution": "1"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "Micom",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "12250421",
"x.com.samsung.da.currentVersionInfo": "10000000",
"otnStatus": "None",
"flashingProgress": "0",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"scheduledTime": "None",
"swVersionInfo": {
"platform": "Tizen Lite",
"oneUiVersion": "7.0 Air purifier",
"osVersion": "4.0"
},
"otnList": [
{
"type": "WIFI",
"modelId": "AVT-KR-TP1-24-AXXX00",
"versions": [
"12260401"
],
"visVersion": "260401"
},
{
"type": "Micom",
"modelId": "895010268241FFFFFFFF",
"versions": [
"25042102",
"FFFFFFFF"
],
"visVersion": "250421"
},
{
"type": "Micom",
"modelId": "09501026824110268341",
"versions": [
"25042102",
"25031801"
],
"visVersion": "250421"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "Branden_Summit"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
}
]
}
+310
View File
@@ -0,0 +1,310 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/airlevelcheck/vs/0",
"rep": {
"x.com.samsung.da.periodicSensingActivationState": "Off",
"x.com.samsung.da.periodicSensingInterval": "600",
"x.com.samsung.da.startSensingOnce": "On",
"x.com.samsung.da.sensingState": "NonProcessing",
"x.com.samsung.da.lastSensingTime": "1785195000",
"x.com.samsung.da.lastSensingLevel": "Kr1",
"x.com.samsung.da.autoExeState": "Off",
"x.com.samsung.da.supportedAutoExeState": [
"Off",
"Airpurify",
"Alarm"
],
"x.com.samsung.da.periodicSensingSkipStatus": "Off",
"x.com.samsung.da.periodicSensingSkipTime": "15002100"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2024-01-01T00:00:00",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "0000000000000000000000000000",
"x.com.samsung.da.id": "VTL",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "3017000000",
"x.com.samsung.da.airconOptionList": [
"WELCOMECARE",
"AI_PURIFY"
],
"x.com.samsung.da.countryCode": ""
}
},
{
"href": "/da/softreset/vs/0",
"rep": {
"x.com.samsung.da.softwarereset": "false"
}
},
{
"href": "/devicespecificinfo/vs/0",
"rep": {
"x.com.samsung.da.deviceActive": true
}
},
{
"href": "/dnd/autosleep/vs/0",
"rep": {
"x.com.samsung.da.startTime": "14:00:00",
"x.com.samsung.da.endTime": "22:00:00",
"x.com.samsung.da.visible": "true",
"x.com.samsung.da.useTimeSetting": "true",
"x.com.samsung.da.functionState": "true"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativePower": "196696",
"x.com.samsung.da.cumulativeDate": "1785245199",
"x.com.samsung.da.cumulativeDateUTC": "1785212799",
"x.com.samsung.da.cumulativeUnit": "Wh"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00"
}
},
{
"href": "/filter/hepafilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "0",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterCapacity": "8760",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable"
]
}
},
{
"href": "/humidity/0",
"rep": {}
},
{
"href": "/humidity/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "A-VTWW-TP2-21-COMMON|10231241|70000535001511EC0505090201000000",
"x.com.samsung.da.description": "A-VTWW-TP2-21-COMMON",
"x.com.samsung.da.serialNum": "REDACTED",
"x.com.samsung.da.otnDUID": "REDACTED",
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "101",
"x.com.samsung.da.diagMinVersion": "1.0",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02308A260310",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "21063003,21063002",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.options": [
"CountOfSlave_0",
"SlavePower01_NotSupported",
"Pollution_Off",
"OptionCode_23418",
"SmartSleep_Off"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "A-VTWW-TP2-21-COMMON",
"versions": [
"12260310"
],
"visVersion": "260310"
},
{
"type": "Micom",
"modelId": "09501023124110231341",
"versions": [
"21063003",
"21063002"
],
"visVersion": "210630"
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "7",
"x.com.samsung.da.longnotisubscription": "true",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/sensors/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Sensor for Dust",
"x.com.samsung.da.type": "Dust",
"x.com.samsung.da.value": [
"5",
"1"
]
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Sensor for FineDust",
"x.com.samsung.da.type": "FineDust",
"x.com.samsung.da.value": [
"5",
"1"
]
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Sensor for Odor",
"x.com.samsung.da.type": "Odor",
"x.com.samsung.da.value": [
"1"
]
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Sensor for CleanLevel",
"x.com.samsung.da.type": "CleanLevel",
"x.com.samsung.da.value": [
"1"
]
},
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Sensor for SuperFineDust",
"x.com.samsung.da.type": "SuperFineDust",
"x.com.samsung.da.value": [
"5",
"1"
]
}
],
"x.com.samsung.da.total": "5"
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "87",
"x.com.samsung.da.supportedModes": [
"87",
"89",
"90",
"91"
],
"x.com.samsung.da.modesName": [
"SMART",
"MAX",
"WINDFREE",
"Sleep"
]
}
}
]
}
+476
View File
@@ -0,0 +1,476 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "54",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Smart",
"Speed",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "Off",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "0",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Low",
"Mid",
"High",
"Turbo"
]
}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Left_And_Right",
"x.com.samsung.da.supportedModes": [
"Fix",
"Up_And_Low",
"Left_And_Right",
"All"
]
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-27T06:07:25",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-27T06:07:25",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "26.0",
"x.com.samsung.da.current": "30.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "18",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 30.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 26.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "0.000000",
"x.com.samsung.da.cumulativePower": "3193591",
"x.com.samsung.da.cumulativeSavedPower": "158331",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 0.0
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Auto",
"Cool",
"Dry",
"Wind"
],
"x.com.samsung.da.modes": [
"Dry"
],
"x.com.samsung.da.options": [
"Sleep_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_270",
"OutdoorConnection_Connected",
"OutdoorTemp_88",
"CoolCapa_53",
"WarmCapa_0",
"Light_Off",
"Volume_100",
"StopAutoClean_Idle",
"Autoclean_Off",
"DiagnosisAI_Off",
"ProgressDiagnosisAI_1",
"ResultDiagnosisAI_Normal",
"SmartCoolClean_Off",
"ProgressSmartClean_0",
"FreezeAlarmSetting_On",
"DesiredFreezeAlarm_112",
"WashAlarm_Off",
"OptionCode_56440",
"ExtendOptionCode_246413",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_0",
"WelcomeCoolingState_On"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off",
"x.com.samsung.da.displaycondition": "Enable"
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ARA-WW-TP1-22-COMMON|10229641|60010535001511014600083200800000",
"x.com.samsung.da.description": "ARA-WW-TP1-22-COMMON",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "010",
"x.com.samsung.da.diagMinVersion": "1.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.serialNumOption": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02378A260327",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102296A23012700",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102295A22113000,102299A10000300",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+08:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"PRODUCT_GLOBAL",
"AI_RAC_GLOBAL_COOLONLY_3.0",
"AI_3.0",
"Auto_To_AI"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "64"
}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 1,
"start": "2026-07-27T05:07:32Z",
"duration": 20,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "1",
"x.com.samsung.da.duration": "20:47:00",
"x.com.samsung.da.drlcStartTime": "2026-07-27T05:07:32Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "000000B4012C016102490C000000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 1
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "ARA-WW-TP1-22-COMMON",
"versions": [
"11260327"
],
"visVersion": "260327"
},
{
"type": "Micom",
"modelId": "",
"versions": [
"23012700",
"FFFFFFFF"
],
"visVersion": "230127"
},
{
"type": "Micom",
"modelId": "",
"versions": [
"23012700",
"FFFFFFFF"
],
"visVersion": "230127"
}
]
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Kuala_Lumpur",
"offset": "+08:00",
"DST": "OFF"
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": "0",
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "dreamer"
}
}
]
}
@@ -0,0 +1,232 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/airflow/0",
"rep": {
"speed": 3,
"direction": "Fix"
}
},
{
"href": "/airflow/vs/0",
"rep": {
"x.com.samsung.da.speedLevel": "3",
"x.com.samsung.da.direction": "Fix"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-28T00:18:15",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-28T00:18:15",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000"
}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativePower": "0"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+01:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ARTIK051_KRAC_18K|10193441|60010119001111110200000000000000",
"x.com.samsung.da.description": "ARTIK051_KRAC_18K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02016A200825",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "18020800,17120500",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/mode/0",
"rep": {
"supportedModes": [
"Cool",
"Dry",
"Wind",
"Auto",
"Heat",
"HOMECARE_WIZARD_V2"
],
"modes": [
"Cool"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Cool",
"Dry",
"Wind",
"Auto",
"Heat",
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.modes": [
"Cool"
],
"x.com.samsung.da.options": [
"Comode_Off",
"Sleep_0",
"OutdoorTemp_74",
"CoolCapa_25",
"WarmCapa_32",
"Spi_Off",
"Autoclean_Off",
"Light_Off",
"Volume_100",
"AirMonitoring_Off",
"AutocleanProgress_1",
"StopAutoClean_Idle",
"FilterTime_1715",
"FilterAlarmTime_500",
"OptionCode_35882",
"ExtendOptionCode_7",
"RacInfo_None",
"UpdateAllow_NotAllowed"
]
}
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 21.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 20.0
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "20",
"x.com.samsung.da.current": "21",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "16",
"x.com.samsung.da.unit": "Celsius"
}
]
}
}
]
}
+446
View File
@@ -0,0 +1,446 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2024-01-01T00:00:00"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "AC_V_0002_OFF",
"x.com.samsung.da.triggeredTime": "2024-01-01T00:00:00"
}
]
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "000000B4012C0000404B0C000000",
"x.com.samsung.da.id": "FAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "2824500000",
"x.com.samsung.da.airconOptionList": [
"HOMECARE_WIZARD_V2",
"ENERGY_2.0",
"AI_2.0",
"DeviceTypeMaster",
"SingleCommand_1"
]
}
},
{
"href": "/diagnosis/vs/0",
"rep": {}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 0,
"start": "1970-01-01T00:00:00Z",
"duration": 0,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.duration": "00:00:00",
"x.com.samsung.da.drlcStartTime": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"energy": 100.0,
"power": 65278.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativeConsumption": "100.000000",
"x.com.samsung.da.instantaneousPower": "65278.000000",
"x.com.samsung.da.usageThreshold": "0.000000",
"x.com.samsung.da.cumulativePower": "1278818",
"x.com.samsung.da.cumulativeDate": "1785243600",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePowerType": "individual"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "100",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "112",
"x.com.samsung.da.filterStatus": "wash",
"x.com.samsung.da.filterCapacity": "112",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"washable"
],
"x.com.samsung.da.supportedFilterDesiredUsage": [
"112",
"224",
"336",
"448"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0.000000",
"x.com.samsung.da.fivepercentHumidity": "73"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP2X_FAC_BORA_21K|10233041|600001110015110006000C1200830000",
"x.com.samsung.da.description": "TP2X_FAC_BORA_21K",
"x.com.samsung.da.serialNum": "REDACTED",
"x.com.samsung.da.otnDUID": "REDACTED",
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "000",
"x.com.samsung.da.diagMinVersion": "1.0",
"x.com.samsung.da.serialNumOption": "REDACTED",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02337A260424",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "2102240021022200",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Outdoor",
"x.com.samsung.da.number": "2103300110000300"
}
]
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 1
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Speed"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"AIComfort",
"Cool",
"Dry",
"Wind"
],
"x.com.samsung.da.modes": [
"AIComfort"
],
"x.com.samsung.da.options": [
"Operation_Family",
"Blooming_0",
"OnTimer_0",
"OffTimer_0",
"Sleep_16",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_270",
"welcomecare_Off",
"Panel_Close",
"Weather_Off",
"Volume_100",
"StopAutoClean_Idle",
"DiagnosisAI_Off",
"Display_Off",
"ProgressDiagnosisAI_1",
"ResultDiagnosisAI_Normal",
"Service_Off",
"SmartCoolClean_Off",
"ProgressSmartClean_0",
"OutDoorVentil_Off",
"FreezeAlarmSetting_On",
"DesiredFreezeAlarm_112",
"OptionCode_529",
"ExtendOptionCode_16975",
"RacInfo_First",
"RacInfo_None_Second",
"ModelInfo_16K_BORA_VENT2",
"UpdateAllow_NotAllowed",
"EnergySaveIcon_Off",
"DurationOn_0",
"welcomecareElapsedTime_0",
"welcomecareThresholdTemp_0",
"welcomecareStartDate_0000",
"welcomecareEndDate_0000",
"welcomecareSeason_None"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "On",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"SpeedClean",
"QuietClean",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"SpeedClean",
"QuietClean",
"Off"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "AFA-KR-TP2-21-AF9X00",
"versions": [
"10260424"
],
"visVersion": "260424"
},
{
"type": "Micom",
"modelId": "04511023304110232941",
"versions": [
"21022400",
"21022200"
],
"visVersion": "210224"
},
{
"type": "Micom",
"modelId": "04511022974110229941",
"versions": [
"21033001",
"10000300"
],
"visVersion": "210330"
},
{
"type": "Micom",
"modelId": "045110230741FFFFFFFF",
"versions": [
"22050300",
"FFFFFFFF"
],
"visVersion": "220503"
}
]
}
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "REDACTED",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "true",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/runn/vs/0",
"rep": {
"x.com.samsung.da.runningMode": 0
}
},
{
"href": "/subdevices/vs/0",
"rep": {
"x.com.samsung.da.subdeviceIdList": "REDACTED"
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
18.0,
30.0
],
"units": "C",
"temperature": 31.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
18.0,
30.0
],
"units": "C",
"temperature": 27.0
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "27.0",
"x.com.samsung.da.current": "31.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "18",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "NotSupported",
"x.com.samsung.da.supportedModes": [
"NotSupported"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "0",
"x.com.samsung.da.supportedModes": [
"0",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Mid",
"High",
"Turbo"
]
}
}
]
}
@@ -0,0 +1,626 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "100",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "wash",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Smart",
"Speed",
"MotionIndirect",
"MotionDirect",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "On",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "3",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Low",
"Mid",
"High",
"Turbo"
]
}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Fix",
"x.com.samsung.da.supportedModes": [
"Fix",
"Up_And_Low",
"Left_And_Right",
"All"
]
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-28T19:55:08",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm",
"x.com.samsung.da.triggeredTime": "2026-07-28T19:55:08",
"x.com.samsung.da.state": "Created"
}
]
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "70.0",
"x.com.samsung.da.current": "69.0",
"x.com.samsung.da.maximum": "86",
"x.com.samsung.da.minimum": "47",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Fahrenheit"
}
]
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
47,
86
],
"units": "F",
"temperature": 69.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
47,
86
],
"units": "F",
"temperature": 70.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "0.000000",
"x.com.samsung.da.cumulativePower": "631483",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 0.0
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Auto",
"Cool",
"Dry",
"Fan",
"Heat"
],
"x.com.samsung.da.modes": [
"Heat"
],
"x.com.samsung.da.options": [
"Sleep_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_990",
"OutdoorTemp_78",
"CoolCapa_35",
"WarmCapa_35",
"Volume_Mute",
"StopAutoClean_Set",
"Autoclean_On",
"DiagnosisAI_Off",
"ProgressDiagnosisAI_0",
"ResultDiagnosisAI_Normal",
"KeyInputPermit_On",
"ModePermit_NoLimit",
"SmartCoolClean_Off",
"ProgressSmartClean_0",
"FreezeAlarmSetting_Off",
"DesiredFreezeAlarm_240",
"WashAlarm_Off",
"OptionCode_56636",
"ExtendOptionCode_246669",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_0",
"WelcomeCoolingState_Off"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off",
"operationNumber": "48"
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_LNX-AC-RAC-01001_0000|10269441|60010523001811014E0048220090A000",
"x.com.samsung.da.description": "TP1X_LNX-AC-RAC-01001_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJV",
"x.com.samsung.da.diagSetupid": "AR2",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02646A260327",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102694A24062500",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102472A24042300,102579A10000200",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "-03:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"PRODUCT_GLOBAL",
"AI_RAC_GLOBAL_HEATPUMP_3.0",
"AI_3.0",
"Auto_To_AI",
"AI_Heat"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "45"
}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 0,
"start": "1970-01-01T00:00:00Z",
"duration": 0,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.duration": "00:00:00",
"x.com.samsung.da.drlcStartTime": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "000001D6035C016102490C0F0000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 1
}
},
{
"href": "/remotedatacontrol/vs/0",
"rep": {
"x.com.samsung.da.status": "Off",
"x.com.samsung.da.connectionStatus": "Disconnected"
}
},
{
"href": "/remotetemperature/vs/0",
"rep": {
"x.com.samsung.da.temperature": "",
"x.com.samsung.da.unit": "",
"x.com.samsung.da.error": ""
}
},
{
"href": "/remotedeviceinfo/vs/0",
"rep": {
"x.com.samsung.da.didList": ""
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "ARA-WW-TP1-24-ARXX00",
"versions": [
"11260327"
],
"visVersion": "260327"
},
{
"type": "Micom",
"modelId": "045210269441FFFFFFFF",
"versions": [
"24062500",
"FFFFFFFF"
],
"visVersion": "240625"
},
{
"type": "Micom",
"modelId": "04521024724110257941",
"versions": [
"24042300",
"10000200"
],
"visVersion": "240423"
}
]
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "America/Halifax",
"offset": "-03:00",
"DST": "ON"
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": "0",
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "AEFFFFFFFF3D564156FFFF2F56FFFF00001F001F00010000001F0000009C00FFFF1E00",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/light/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/mds/absencepowersaving/vs/0",
"rep": {
"status": "Off",
"modes": "Cooling_Heating",
"switchPowerSaveMode": "Normal",
"motionState": "Normal",
"supportedModes": [
"Cooling_Heating",
"Standby"
],
"supportedSwitchPowerSaveMode": [
"Eco",
"Normal",
"Comfort"
],
"supportedMotionState": [
"Normal",
"MotionNano",
"MotionSoftOff"
]
}
},
{
"href": "/mds/absencestate/vs/0",
"rep": {
"status": "Off",
"maxDetectCount": [
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254",
"254"
],
"supportedTime": [
"0",
"30",
"60"
]
}
},
{
"href": "/option/motiondetectwind/stateful/vs/0",
"rep": {
"status": "Off",
"modes": "Indirect",
"supportedModes": [
"Direct",
"Indirect"
]
}
},
{
"href": "/welcome/temperature/vs/0",
"rep": {
"operatingStatus": "None",
"requestId": "0000"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "KG_IoT"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
}
]
}
+525
View File
@@ -0,0 +1,525 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": "0",
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2024-01-01T00:00:00",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2024-01-01T00:00:00",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "1DBF00A0012C3F61024804000000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "1150000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"AI_RAC_KOREA_COOLONLY_3.0",
"AI_3.0",
"Auto_To_AI"
]
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 0,
"start": "1970-01-01T00:00:00Z",
"duration": 0,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.duration": "00:00:00",
"x.com.samsung.da.drlcStartTime": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 338.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "338.000000",
"x.com.samsung.da.cumulativePower": "1362848",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "2",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "42"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_DA-AC-RAC-01001_0000|10250041|6001051C001711014E00482200912000",
"x.com.samsung.da.description": "TP1X_DA-AC-RAC-01001_0000",
"x.com.samsung.da.serialNum": "REDACTED",
"x.com.samsung.da.otnDUID": "REDACTED",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AR1",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.serialNumOption": "REDACTED",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02646A260327",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102500A23012700",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102472A22120800,102528A10000100",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 0
}
},
{
"href": "/light/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Smart",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"AIComfort",
"Cool",
"Dry",
"Wind"
],
"x.com.samsung.da.modes": [
"Cool"
],
"x.com.samsung.da.options": [
"Sleep_16",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_280",
"welcomecare_Off",
"OutdoorConnection_Connected",
"OutdoorTemp_86",
"CoolCapa_28",
"WarmCapa_0",
"Volume_100",
"StopAutoClean_Set",
"Autoclean_On",
"DiagnosisAI_Off",
"ProgressDiagnosisAI_0",
"ResultDiagnosisAI_Normal",
"SmartCoolClean_Off",
"ProgressSmartClean_0",
"FreezeAlarmSetting_Off",
"DesiredFreezeAlarm_240",
"WashAlarm_Off",
"OptionCode_56440",
"ExtendOptionCode_246479",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_115",
"welcomecareElapsedTime_0",
"welcomecareThresholdTemp_0",
"welcomecareStartDate_0000",
"welcomecareEndDate_0000",
"welcomecareSeason_None"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "On",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "ARA-WW-TP1-24-ARXX00",
"versions": [
"11260327"
],
"visVersion": "260327"
},
{
"type": "Micom",
"modelId": "045210250041FFFFFFFF",
"versions": [
"23012700",
"FFFFFFFF"
],
"visVersion": "230127"
},
{
"type": "Micom",
"modelId": "04521024724110252841",
"versions": [
"22120800",
"10000100"
],
"visVersion": "221208"
}
]
}
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "REDACTED",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": true
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On",
"causeSource": "SMTS"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "true",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/remotedatacontrol/vs/0",
"rep": {
"x.com.samsung.da.status": "Off",
"x.com.samsung.da.connectionStatus": "Disconnected"
}
},
{
"href": "/remotedeviceinfo/vs/0",
"rep": {
"x.com.samsung.da.didList": ""
}
},
{
"href": "/remotetemperature/vs/0",
"rep": {
"x.com.samsung.da.temperature": "",
"x.com.samsung.da.unit": "",
"x.com.samsung.da.error": ""
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "1DFFFFFFFF101E121EFFFFFFFFFFFF01000000012F0100000F000000001C00",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 28.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 25.0
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "25.0",
"x.com.samsung.da.current": "28.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "16",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Fix",
"x.com.samsung.da.supportedModes": [
"Fix",
"Up_And_Low",
"Left_And_Right",
"All"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "32",
"x.com.samsung.da.supportedModes": [
"0",
"31",
"32",
"33",
"34",
"35"
],
"x.com.samsung.da.modesName": [
"Auto",
"1",
"2",
"3",
"4",
"MAX"
]
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "REDACTED",
"macaddressBLE": "REDACTED",
"connectedApSsid": "REDACTED"
}
}
]
}
@@ -0,0 +1,515 @@
{
"meta": {
"model": "TP1X_DA-AC-RAC-01001_0000",
"device_type": "airconditioner",
"source": "user diagnostics (scrubbed)",
"note": "Cool-only global TP1X RAC variant (airconOptionList AI_RAC_GLOBAL_COOLONLY_3.0). Unlike the other TP1X_DA-AC-RAC dumps, its /otninformation/vs/0 ships no swVersionInfo block, so oneUiVersion is empty and detection must fall back to the hyphenated '-RAC-' modelNum token in for_device_by_model. Adds two hrefs absent from the other AC dumps -- /stepcontrol/vs/0 (manual airflow step) and /remotedeviceinfo/vs/0 (empty paired-device list), both ignored -- and exposes Samsung WindFree via the convenient-mode codes Nano/NanoSleep (in place of the Smart code on other boards; confirmed by an off-vs-on dump diff)."
},
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "100",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "wash",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Speed",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "Off",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "0",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Low",
"Mid",
"High",
"Turbo"
]
}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Fix",
"x.com.samsung.da.supportedModes": [
"Fix",
"Up_And_Low",
"Left_And_Right",
"All"
]
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T15:24:44",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm",
"x.com.samsung.da.triggeredTime": "2026-07-26T15:24:44",
"x.com.samsung.da.state": "Created"
}
]
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "25.0",
"x.com.samsung.da.current": "20.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "16",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 20.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 25.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "0.000000",
"x.com.samsung.da.cumulativePower": "445938",
"x.com.samsung.da.cumulativeSavedPower": "81528",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 0.0
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Auto",
"Cool",
"Dry",
"Wind"
],
"x.com.samsung.da.modes": [
"Auto"
],
"x.com.samsung.da.options": [
"Sleep_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_240",
"OutdoorTemp_84",
"CoolCapa_35",
"WarmCapa_0",
"Light_Off",
"Volume_Mute",
"StopAutoClean_Idle",
"Autoclean_Off",
"DiagnosisAI_Off",
"ProgressDiagnosisAI_0",
"ResultDiagnosisAI_Normal",
"OptionCode_52344",
"ExtendOptionCode_230029",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_0",
"WelcomeCoolingState_Off"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off",
"causeSource": "DEFT",
"operationNumber": "0"
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_DA-AC-RAC-01001_0000|10247441|60010523001811014E00002200D00000",
"x.com.samsung.da.description": "TP1X_DA-AC-RAC-01001_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AR2",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02646A260327",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102474A23112200",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "102702A24041900,102579A10000200",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "-03:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"PRODUCT_GLOBAL",
"AI_RAC_GLOBAL_COOLONLY_3.0",
"AI_3.0",
"Auto_To_AI"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "66"
}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 1,
"start": "2026-07-26T12:01:41Z",
"duration": 23,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "1",
"x.com.samsung.da.duration": "23:59:00",
"x.com.samsung.da.drlcStartTime": "2026-07-26T12:01:41Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "000000A0012C0161024904000000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/stepcontrol/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"80",
"60",
"40",
"Power"
]
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 1
}
},
{
"href": "/remotedatacontrol/vs/0",
"rep": {
"x.com.samsung.da.status": "Off",
"x.com.samsung.da.connectionStatus": "Disconnected"
}
},
{
"href": "/remotetemperature/vs/0",
"rep": {
"x.com.samsung.da.temperature": "",
"x.com.samsung.da.unit": "",
"x.com.samsung.da.error": ""
}
},
{
"href": "/remotedeviceinfo/vs/0",
"rep": {
"x.com.samsung.da.didList": ""
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "ARA-WW-TP1-24-ARXX00",
"versions": [
"11260327"
],
"visVersion": "260327"
},
{
"type": "Micom",
"modelId": "045210247441FFFFFFFF",
"versions": [
"23112200",
"FFFFFFFF"
],
"visVersion": "231122"
},
{
"type": "Micom",
"modelId": "04521027024110257941",
"versions": [
"24041900",
"10000200"
],
"visVersion": "240419"
}
]
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "America/Sao_Paulo",
"offset": "-03:00",
"DST": "OFF"
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": "0",
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "**REDACTED**"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
}
]
}
+380
View File
@@ -0,0 +1,380 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-25T08:19:03"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-25T08:19:03"
}
]
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"HOMECARE_WIZARD_V2",
"PRODUCT_GLOBAL",
"AI_RAC_GLOBAL_2.0",
"AI_2.0",
"Auto_To_AI",
"AI_Heat"
]
}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 0.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "0",
"x.com.samsung.da.cumulativePower": "320466",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+00:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "41",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "42"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ARTIK051_PRAC_20K|10217841|60010519001411010200001000000000",
"x.com.samsung.da.description": "ARTIK051_PRAC_20K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.serialNumOption": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02181A230313",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "20082000,FFFFFFFF",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Outdoor",
"x.com.samsung.da.number": "20091600,10000400"
}
]
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Smart",
"Speed",
"MotionIndirect",
"MotionDirect",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Cool",
"Dry",
"Wind",
"Auto",
"Heat"
],
"x.com.samsung.da.modes": [
"Dry"
],
"x.com.samsung.da.options": [
"Sleep_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"MotionState_Normal",
"AiTempChanged_Off",
"AiTemp_240",
"OutdoorTemp_87",
"CoolCapa_25",
"WarmCapa_32",
"Light_Off",
"Volume_100",
"MotionMode_Default",
"OptionCode_56376",
"ExtendOptionCode_781",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_0",
"WelcomeCoolingState_Off"
]
}
},
{
"href": "/option/airpurify/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "On",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/sensors/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Sensor for CleanLevel",
"x.com.samsung.da.type": "CleanLevel",
"x.com.samsung.da.value": [
"0"
]
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Sensor for Odor",
"x.com.samsung.da.type": "Odor",
"x.com.samsung.da.value": [
"0"
]
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Sensor for Dust",
"x.com.samsung.da.type": "Dust",
"x.com.samsung.da.value": [
"0",
"0"
]
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Sensor for FineDust",
"x.com.samsung.da.type": "FineDust",
"x.com.samsung.da.value": [
"0",
"0"
]
},
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Sensor for SuperFineDust",
"x.com.samsung.da.type": "SuperFineDust",
"x.com.samsung.da.value": [
"0",
"0"
]
}
]
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 27.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 26.0
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "26.0",
"x.com.samsung.da.current": "27.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "18",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Fix",
"x.com.samsung.da.supportedModes": [
"Fix",
"All",
"Up_And_Low",
"Left_And_Right"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "0",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Low",
"Mid",
"High",
"Turbo"
]
}
}
]
}
@@ -0,0 +1,590 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": 0,
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-27T11:59:06",
"x.com.samsung.da.state": "Deleted"
}
],
"rt": [
"x.com.samsung.da.alarms"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/anomalyload/vs/0",
"rep": {
"operation": "Off",
"mode": "Alarm",
"supportedModes": [
"Alarm",
"PowerSaving"
],
"savingTime": "20",
"supportedSavingTime": [
"20",
"40",
"60"
]
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "000000A0012C01610CC90C0F0000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"PRODUCT_GLOBAL",
"AI_GLOBAL_COOLONLY_4.0",
"AI_3.0",
"Auto_To_AI",
"ENERGY_2.0",
"HOMECARE_WIZARD_V2",
"DR",
"SingleCommand_1"
],
"InstalledRoomSize": "0.0",
"SkipInstalledRoomSize": "false",
"RoomSizeMenuNumber": "Manual"
}
},
{
"href": "/da/softreset/vs/0",
"rep": {
"x.com.samsung.da.softwarereset": "false"
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.start": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.durationminutes": "0",
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativeDate": "1785153515",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativePower": "47536",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePowerType": "total"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+08:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterCapacity": "180",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
],
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterUsage": "44",
"x.com.samsung.da.filterDesiredUsage": "180",
"x.com.samsung.da.supportedFilterDesiredUsage": [
"180",
"300",
"500",
"700"
]
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "46"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.modelNum": "TP1X_DA-AC-RAC-01011_0000|10281241|6001051A001911018E0049300002A900",
"x.com.samsung.da.description": "TP1X_DA-AC-RAC-01011_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.serialNumOption": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02825A260401",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.newVersionAvailable": "0",
"x.com.samsung.da.number": "02812A25111800,FFFFFFFFFFFFFF"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.newVersionAvailable": "0",
"x.com.samsung.da.number": "02813A25101500,FFFFFFFFFFFFFF"
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.newVersionAvailable": "0",
"x.com.samsung.da.number": "FFFFFFFFFFFFFF,FFFFFFFFFFFFFF"
}
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AR2",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 0
}
},
{
"href": "/light/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/mds/absencemonitoring/vs/0",
"rep": {}
},
{
"href": "/mds/absencestate/vs/0",
"rep": {}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep",
"Quiet",
"Smart",
"Speed",
"Nano",
"NanoSleep",
"DryComfort"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.modes": [
"Cool"
],
"workingMode": "Cool",
"x.com.samsung.da.supportedModes": [
"Auto",
"Cool",
"Dry",
"Fan"
],
"x.com.samsung.da.options": [
"OptionCode_56416",
"Sleep_0",
"SleepRemainTime_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_240",
"Volume_100",
"DiagnosisAI_Off",
"ProgressDiagnosisAI_0",
"ResultDiagnosisAI_Normal",
"SmartCoolClean_Off",
"ProgressSmartClean_0",
"OutDoorVentil_Off",
"InDoorVentil_Off",
"FreezeAlarmSetting_Off",
"DesiredFreezeAlarm_240",
"WashAlarm_Off",
"ExtendOptionCode_246413",
"UpdateAllow_NotAllowed",
"DurationOn_0",
"WelcomeCoolingState_Off"
],
"rt": [
"x.com.samsung.da.mode"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.settingStatus": "Off",
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
],
"defaultSettingStatus": "On"
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off",
"rt": [
"x.com.samsung.da.option.muteonce"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/personality/presence/vs/0",
"rep": {}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off",
"operationNumber": "2",
"displayCondition": "Enable"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "8EFFFFFFFF101E121EFFFFFFFFFFFF000001001F0001000000000000009C00FFFF1E00",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/selfcheck/vs/0",
"rep": {
"x.com.samsung.da.start": "Cancel",
"x.com.samsung.da.status": "Ready",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.result": "NA",
"x.com.samsung.da.supportedActions": [
"Start",
"Cancel"
],
"x.com.samsung.da.error": [
"DA_ERROR_NONE"
]
}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.current": "29.0",
"x.com.samsung.da.desired": "18.0",
"x.com.samsung.da.minimum": "16",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.increment": "1",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/wind/oscillation/vs/0",
"rep": {
"vertical": "Fix",
"supportedVertical": [
"Swing",
"Fix"
],
"verticalAngle": "4",
"supportedVerticalAngle": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"horizontal": "Fix",
"supportedHorizontal": [
"Swing",
"Fix"
],
"horizontalSwingMode": "AllSwing",
"supportedHorizontalSwingMode": [
"AllSwing",
"LeftSwing",
"RightSwing"
],
"horizontalAngle": "3",
"supportedHorizontalAngle": [
"1",
"2",
"3",
"4",
"5"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "1",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4"
],
"x.com.samsung.da.modesName": [
"Auto",
"Low",
"Mid",
"High",
"Turbo"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"otnStatus": "None",
"flashingProgress": "0",
"otnCompleteDate": "noHistory",
"scheduledTime": "None",
"swVersionInfo": {
"platform": "Tizen Lite",
"oneUiVersion": "7.0 Air conditioner",
"osVersion": "4.0"
},
"otnList": [
{
"type": "WIFI",
"modelId": "ARA-WW-TP1-26-AR6X00MG",
"versions": [
"11260401"
],
"visVersion": "260401"
},
{
"type": "Micom",
"modelId": "845241131741FFFFFFFF",
"versions": [
"25102900",
"FFFFFFFF"
],
"visVersion": "251029"
},
{
"type": "Micom",
"modelId": "045210281241FFFFFFFF",
"versions": [
"25111800",
"FFFFFFFF"
],
"visVersion": "251118"
},
{
"type": "Micom",
"modelId": "045210281341FFFFFFFF",
"versions": [
"25101500",
"FFFFFFFF"
],
"visVersion": "251015"
},
{
"type": "Micom",
"modelId": "0452FFFFFFFFFFFFFFFF",
"versions": [
"FFFFFFFF",
"FFFFFFFF"
],
"visVersion": "999999"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Kuala_Lumpur",
"offset": "+08:00",
"DST": "OFF"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "K9 Unit"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
},
{
"href": "/dginformation/vs/0",
"rep": {
"enrolmentstatus": "Unknown",
"devicestate": "Unknown",
"lockstatus": "Unknown",
"nextduedate": "",
"workingminutes": 0,
"paymentinfo": {
"emiplan": "Unknown",
"currency": "Unknown",
"totalemi": 0,
"totalemipaid": 0
}
}
},
{
"href": "/temperature/desired/0",
"rep": {
"temperature": 25
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
}
]
}
+523
View File
@@ -0,0 +1,523 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/aisleep/vs/0",
"rep": {
"x.com.samsung.da.displayNightMode": "Off",
"x.com.samsung.da.elapsedTime": "0",
"x.com.samsung.da.requestFeedback": "Off",
"x.com.samsung.da.resultFeedback": "0",
"x.com.samsung.da.statusFeedback": "Idle",
"x.com.samsung.da.sleepTime": "14002200"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T06:26:40",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T06:26:40",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "8D0D00B4012C3F21064804000000",
"x.com.samsung.da.id": "RAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "2647000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"AI_RAC_KOREA_COOLONLY_3.0",
"AI_3.0",
"Auto_To_AI"
]
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 0,
"start": "1970-01-01T00:00:00Z",
"duration": 0,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.duration": "00:00:00",
"x.com.samsung.da.drlcStartTime": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/energy/consumption/0",
"rep": {
"power": 244.0
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "244.000000",
"x.com.samsung.da.cumulativePower": "11001",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePowerType": "total"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "20",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "500",
"x.com.samsung.da.filterStatus": "normal",
"x.com.samsung.da.filterCapacity": "500",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"replaceable",
"washable"
]
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0",
"x.com.samsung.da.fivepercentHumidity": "60"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_DA_AC_WAC_01001_0000|10254341|60050000001711014E00402000002000",
"x.com.samsung.da.description": "TP1X_DA_AC_WAC_01001_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AW0",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02545A260601",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "02543A24061800,FFFFFFFFFFFFFF",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Outdoor",
"x.com.samsung.da.number": "02580A10000100,FFFFFFFFFFFFFF"
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Touch IC",
"x.com.samsung.da.number": "02553A23031600,FFFFFFFFFFFFFF"
}
]
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 0
}
},
{
"href": "/light/vs/0",
"rep": {
"mode": "On",
"supportedModes": [
"On",
"Off"
]
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.modes": "Off",
"x.com.samsung.da.supportedModes": [
"Off",
"Quiet",
"Nano",
"NanoSleep"
]
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"AIComfort",
"Cool",
"Dry",
"Fan"
],
"x.com.samsung.da.modes": [
"Cool"
],
"x.com.samsung.da.options": [
"OnTimer_0",
"OffTimer_0",
"ArtificialWorking_Off",
"ComfortAICooling_Off",
"AiTempChanged_Off",
"AiTemp_230",
"Volume_Mute",
"OutdoorTemp_97",
"CoolCapa_0",
"StopAutoClean_Idle",
"Autoclean_Off",
"OptionCode_51320",
"ExtendOptionCode_230093",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"DurationOn_93",
"WelcomeCoolingState_Off"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "Off",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.supportedStatus": [
"Start",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"Off"
]
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "AWA-KR-TP1-23-AW7000",
"versions": [
"15260601"
],
"visVersion": "260601"
},
{
"type": "Micom",
"modelId": "042010254341FFFFFFFF",
"versions": [
"24061800",
"FFFFFFFF"
],
"visVersion": "240618"
},
{
"type": "Micom",
"modelId": "042010258041FFFFFFFF",
"versions": [
"10000100",
"FFFFFFFF"
],
"visVersion": "100001"
},
{
"type": "Micom",
"modelId": "042010255341FFFFFFFF",
"versions": [
"23031600",
"FFFFFFFF"
],
"visVersion": "230316"
}
]
}
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": true
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On",
"causeSource": "SMTS"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "true",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "8DFFFFFFFF121E121E0000FFFFFFFFFFFF01000000011F0000000000000000001F8C00",
"x.com.samsung.da.id": "WAC",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/selfcheck/vs/0",
"rep": {
"x.com.samsung.da.start": "Cancel",
"x.com.samsung.da.status": "Ready",
"x.com.samsung.da.progress": "0",
"x.com.samsung.da.result": "NA",
"x.com.samsung.da.supportedActions": [
"Start",
"Cancel"
],
"x.com.samsung.da.error": [
"DA_ERROR_NONE"
]
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/temperature/control/vs/0",
"rep": {
"x.com.samsung.da.increment": "1"
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 30.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16,
30
],
"units": "C",
"temperature": 30.0
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "30.0",
"x.com.samsung.da.current": "30.0",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "18",
"x.com.samsung.da.increment": "1.0",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/welcome/temperature/vs/0",
"rep": {
"operatingStatus": "None",
"requestId": "0000"
}
},
{
"href": "/wind/direction/vs/0",
"rep": {
"x.com.samsung.da.modes": "Fix",
"x.com.samsung.da.supportedModes": [
"Fix",
"Left_And_Right"
]
}
},
{
"href": "/wind/strength/vs/0",
"rep": {
"x.com.samsung.da.modes": "1",
"x.com.samsung.da.supportedModes": [
"0",
"1",
"2",
"3",
"4",
"5"
],
"x.com.samsung.da.modesName": [
"Auto",
"1",
"2",
"3",
"4",
"5"
]
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**",
"connectedApSsid": "**REDACTED**"
}
}
]
}
+386
View File
@@ -0,0 +1,386 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "false",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/filter/airdustfilter/vs/0",
"rep": {
"x.com.samsung.da.filterUsage": "100",
"x.com.samsung.da.filterUsageResolution": "1",
"x.com.samsung.da.filterDesiredUsage": "224",
"x.com.samsung.da.filterStatus": "wash",
"x.com.samsung.da.filterCapacity": "224",
"x.com.samsung.da.filterCapacityUnit": "Hour",
"x.com.samsung.da.filterResetType": [
"washable"
],
"x.com.samsung.da.supportedFilterDesiredUsage": [
"224",
"300",
"500",
"700"
]
}
},
{
"href": "/mode/convenient/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Off",
"Sleep"
]
}
},
{
"href": "/option/autoclean/vs/0",
"rep": {
"x.com.samsung.da.status": "Stop",
"x.com.samsung.da.settingStatus": "On",
"x.com.samsung.da.progress": "100",
"cleaningTime": "30",
"minCleaningTime": "10",
"maxCleaningTime": "60",
"cleaningTimeUnit": "10",
"x.com.samsung.da.supportedStatus": [
"Start",
"TimedClean",
"Stop"
],
"x.com.samsung.da.supportedSettingStatus": [
"On",
"TimedClean",
"Off"
]
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T10:35:53",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "WaterTankFull_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-26T10:35:53",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "259.000000",
"x.com.samsung.da.cumulativePower": "183099",
"x.com.samsung.da.cumulativeSavedPower": "0",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePowerType": "total"
}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Smart",
"Max",
"High",
"Medium",
"Quiet",
"ClothesDrying"
],
"x.com.samsung.da.modes": [
"Smart"
],
"x.com.samsung.da.options": [
"Volume_Mute",
"RacInfo_None",
"UpdateAllow_NotAllowed",
"WelcomeCoolingState_Off"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On",
"causeSource": "SMTS"
}
},
{
"href": "/sensors/vs/0",
"rep": {}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "TP1X_DA_AC_DHM_01001_0000|10253841|77000000001700000A00000000000000",
"x.com.samsung.da.description": "TP1X_DA_AC_DHM_01001_0000",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AY0",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02544A260401",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "02538A24032700,FFFFFFFFFFFFFF",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Outdoor",
"x.com.samsung.da.number": "02590A10000100,FFFFFFFFFFFFFF"
},
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Touch IC",
"x.com.samsung.da.number": "02552A23020200,FFFFFFFFFFFFFF"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+09:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.airconOptionList": [
"SingleCommand_1",
"DR",
"HOMECARE_WIZARD_V2",
"PRODUCT_GLOBAL",
"AI_RAC_GLOBAL_2.0",
"AI_Heat"
]
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "47",
"x.com.samsung.da.desiredHumidity": "50",
"increment": "5",
"x.com.samsung.da.fivepercentHumidity": "46"
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.durationminutes": "0",
"x.com.samsung.da.start": "1970-01-01T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/availablecontrolsets/vs/0",
"rep": {
"x.com.samsung.da.sets": "20001E46070A5A00000000000000",
"x.com.samsung.da.id": "DHM",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/da/softreset/vs/0",
"rep": {
"x.com.samsung.da.softwarereset": "false"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 0
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "noHistory",
"otnList": [
{
"type": "WIFI",
"modelId": "ADH-WW-TP1-23-AY7100",
"versions": [
"18260401"
],
"visVersion": "260401"
},
{
"type": "Micom",
"modelId": "042110253841FFFFFFFF",
"versions": [
"24032700",
"FFFFFFFF"
],
"visVersion": "240327"
},
{
"type": "Micom",
"modelId": "042110259041FFFFFFFF",
"versions": [
"10000100",
"FFFFFFFF"
],
"visVersion": "100001"
},
{
"type": "Micom",
"modelId": "042110255241FFFFFFFF",
"versions": [
"23020200",
"FFFFFFFF"
],
"visVersion": "230202"
}
]
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/option/muteonce/vs/0",
"rep": {
"muteonce": "Off"
}
},
{
"href": "/reserverulesets/vs/0",
"rep": {
"x.com.samsung.da.sets": "3F1E461E461E46FFFFFFFF1E4600",
"x.com.samsung.da.id": "DHM",
"x.com.samsung.da.version": "1.0"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/welcome/humidity/vs/0",
"rep": {
"requestId": "0000",
"operatingStatus": "None"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
}
]
}
+391
View File
@@ -0,0 +1,391 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000",
"x.com.samsung.da.countryCode": "US"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/course/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.options": [
"DeviceType_0152",
"UpdateAllow_NotAllowed",
"Course_01",
"AiOption_On",
"MixedLoadBell_Disable",
"MixedLoadBellNoti_Nothing",
"LaundryOutTime_0",
"SeamlessControl_Enable",
"KidsLockBypass_On",
"DetergentOnce_1",
"DetergentLeft_0",
"DetergentBase_5",
"DetergentAlarm_Off",
"DetergentType_3",
"DetergentTotal_0",
"SpecialFunction_20",
"AvailableDelayTime_39",
"LaundryPlannerUserSetTime_0",
"ProgressTimeSet_B20870B400B4",
"WrinklePreventRunning_Off",
"DryTime_0",
"SendToDevice_Off",
"GMT_F6",
"DryTimeSet_0A00000000500A005A00000000000000001E0A005A00000000000000001414005A000000000000000000000000000000000000000000000000000000000000000000000000140A005A280A005A",
"EnergyLevelSet_0504040504040205020204040305020203030103",
"MostUsed_068A3ED000",
"WrinklePreventSet_0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F",
"MixedLoadBellSet_02FF02FFFF02FFFFFF0202FF02FFFF02FFFFFF",
"GeoFenceAlarm",
"UsagesDB_ok",
"EnergyKW_396",
"DrumCleanLog_Empty",
"TimeSync_NotSupported"
],
"x.com.samsung.da.supportedOptions": [
"2018410D33E06833ED0002F8520D33E178520D3083E8520D000078102D33E338520D520358520D000348520D0000E8520D33E058520D33E308410D308318410D33E098410D3080F8204D308328308D33E2E8102D308368000D0000D8102D000"
]
}
},
{
"href": "/cycleinterface/vs/0",
"rep": {
"x.com.samsung.da.cycleInterfaceEnabled": "On"
}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "-500",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePower": "2323800",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.cumulativeDate": "1784991600",
"x.com.samsung.da.cumulativeDateUTC": "1785009600"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "-05:00"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "DA_WM_TP1_21_COMMON|20286441|300000010015110002A3031700000000",
"x.com.samsung.da.description": "DA_WM_TP1_21_COMMON_DVE50A8800_8600/DC92-02835A_0080",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "310",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "DA_WM_TP1_21_COMMON|20286441|300000010015110002A3031700000000",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02986A260118(A182)",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Firmware_1_DB_20286441210514150FFFFF202835412105131904FFFF(01522028644120283541_30000000)(FileDown:0)(Type:0)",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "02864A21051415,02835A21051319",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/kidslock/0",
"rep": {
"value": false
}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/operational/state/0",
"rep": {
"currentMachineState": "**REDACTED**",
"machineStates": "**REDACTED**",
"jobStates": [
"None",
"Drying",
"Cooling",
"Finish"
],
"currentJobState": "None",
"remainingTime": "01:15:00",
"progressPercentage": "1"
}
},
{
"href": "/operational/state/vs/0",
"rep": {
"x.com.samsung.da.state": "Ready",
"x.com.samsung.da.remainingTime": "01:15:00",
"x.com.samsung.da.progressPercentage": "1",
"x.com.samsung.da.progress": "None",
"x.com.samsung.da.delayEndTime": "00:00:00",
"x.com.samsung.da.supportedProgress": [
"None",
"Drying",
"Cooling",
"Finish"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "2026-03-04",
"otnList": [
{
"type": "WIFI",
"modelId": "DA_WM_TP1_21_COMMON",
"versions": [
"30260118"
],
"visVersion": "260118"
},
{
"type": "Micom",
"modelId": "01522028644120283541",
"versions": [
"21051415",
"21051319"
],
"visVersion": "210514"
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "10",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/remotectrl/0",
"rep": {
"value": false
}
},
{
"href": "/remotectrl/vs/0",
"rep": {
"x.com.samsung.da.remoteControlEnabled": "false"
}
},
{
"href": "/setting/vs/0",
"rep": {
"x.com.samsung.da.supportedSetLanguage": [
"en_US",
"ko_KR",
"fr_CA",
"es_MX",
"pt_BR"
],
"x.com.samsung.da.setLanguage": "en_US"
}
},
{
"href": "/st/dryercourse/vs/0",
"rep": {
"x.com.samsung.da.st.dryerMode": "Table_03_Course_01",
"x.com.samsung.da.st.courseTable": "Table_03"
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "America/Chicago",
"offset": "-05:00",
"DST": "ON"
}
},
{
"href": "/washer/vs/0",
"rep": {
"x.com.samsung.da.wrinklePrevent": "Off",
"x.com.samsung.da.waterTemperature": "Medium",
"x.com.samsung.da.supportedWaterTemperature": [
"None",
"ExtraLow",
"Low",
"MediumLow",
"Medium",
"High"
],
"x.com.samsung.da.dryLevel": "Normal",
"x.com.samsung.da.supportedDryLevel": [
"None",
"Damp",
"Less",
"Normal",
"More",
"Very"
],
"x.com.samsung.da.dryerType": "Electricity"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "**REDACTED**",
"macaddressBLE": "**REDACTED**"
}
},
{
"href": "/wm/editcourse/vs/0",
"rep": {
"x.com.samsung.da.editCourseList": "EditCourseList_0106",
"x.com.samsung.da.fixedCourseList": "FixedCourseList_0101"
}
},
{
"href": "/wm/jobbeginingstatus/vs/0",
"rep": {
"x.com.samsung.da.currentStatus": "None"
}
},
{
"href": "/wm/personalcourse/vs/0",
"rep": {
"x.com.samsung.da.courses": [
"F1_00",
"F2_00",
"F3_00",
"F4_00",
"F5_00",
"F6_00",
"F7_00",
"F8_00",
"F9_00",
"FA_00"
],
"x.com.samsung.da.maxCourseNum": "10"
}
},
{
"href": "/wm/setinfo/vs/0",
"rep": {
"x.com.samsung.da.isModelSettingWithoutSC": "true",
"x.com.samsung.da.aiCourse": "false",
"x.com.samsung.da.isModelSettingPowerOnOff": "false",
"x.com.samsung.da.modelCode": "M(None),W(DVE50A8600V/A3)"
}
},
{
"href": "/wm/welcomemsg/vs/0",
"rep": {}
}
]
}
+20
View File
@@ -0,0 +1,20 @@
{
"state_keys": [
"alarm_code",
"child_lock",
"completion_minutes",
"cycle",
"cycle_active",
"delay_start_hours",
"diagnosis_status",
"energy_kwh",
"finish_time",
"job_beginning_status",
"machine_state",
"power_switch",
"progress",
"progress_percentage",
"remote_control",
"wrinkle_prevent"
]
}
+22
View File
@@ -0,0 +1,22 @@
{
"state_keys": [
"alarm_code",
"child_lock",
"completion_minutes",
"cycle",
"cycle_active",
"delay_start_hours",
"diagnosis_status",
"energy_kwh",
"finish_time",
"firmware_update",
"job_beginning_status",
"machine_state",
"power_switch",
"progress",
"progress_percentage",
"remote_control",
"sanitize",
"wrinkle_prevent"
]
}
+1 -7
View File
@@ -1,24 +1,18 @@
{
"state_keys": [
"airflow_fan",
"alarm_code",
"clean_level",
"device_active",
"diagnosis_status",
"display_light",
"dust",
"energy_kwh",
"energy_last_month_kwh",
"energy_saved_kwh",
"energy_this_month_kwh",
"fan_direction",
"fan_speed_level",
"filter_progress",
"fine_dust",
"odor",
"operating_mode",
"power_energy_kwh",
"power_switch",
"power_watts",
"super_fine_dust"
]
}
+27
View File
@@ -0,0 +1,27 @@
{
"state_keys": [
"alarm_code",
"child_lock",
"clean_level",
"device_active",
"display",
"display_light",
"dust",
"energy_kwh",
"energy_saved_kwh",
"fan",
"fine_dust",
"firmware_update",
"hepa_filter_status",
"hepa_filter_usage",
"mute_once",
"odor",
"panel_status",
"pet_filter_activation",
"power_switch",
"sound_mode",
"sound_output",
"sound_volume",
"super_fine_dust"
]
}
+17
View File
@@ -0,0 +1,17 @@
{
"state_keys": [
"alarm_code",
"clean_level",
"device_active",
"dust",
"energy_kwh",
"fine_dust",
"firmware_update",
"hepa_filter_status",
"hepa_filter_usage",
"odor",
"power_switch",
"super_fine_dust",
"wind_strength_fan"
]
}
+12 -1
View File
@@ -2,13 +2,24 @@
"state_keys": [
"air_filter_status",
"air_filter_usage",
"air_filter_usage_hours",
"air_purify",
"alarm_code",
"auto_clean",
"beep",
"clean_level",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"dust",
"energy_kwh",
"energy_saved_kwh",
"power_watts"
"fine_dust",
"humidity",
"odor",
"power_watts",
"super_fine_dust",
"tropical_night_mode"
]
}
+20
View File
@@ -0,0 +1,20 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"air_filter_usage_hours",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts",
"tropical_night_mode"
]
}
@@ -0,0 +1,18 @@
{
"state_keys": [
"air_monitoring",
"alarm_code",
"auto_clean_legacy",
"buzzer_volume",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"energy_kwh",
"filter_time",
"good_sleep",
"humidity",
"outdoor_temperature",
"spi"
]
}
+7 -1
View File
@@ -2,14 +2,20 @@
"state_keys": [
"air_filter_status",
"air_filter_usage",
"air_filter_usage_hours",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts"
"power_watts",
"tropical_night_mode"
]
}
+20
View File
@@ -0,0 +1,20 @@
{
"state_keys": [
"air_filter_status",
"air_filter_threshold",
"air_filter_usage",
"air_filter_usage_hours",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_temperature_c",
"diagnosis_status",
"energy_kwh",
"firmware_update",
"humidity",
"power_energy_kwh",
"power_watts",
"tropical_night_mode"
]
}
@@ -0,0 +1,24 @@
{
"state_keys": [
"absence_power_saving_active",
"absence_power_saving_mode",
"air_filter_status",
"air_filter_usage",
"air_filter_usage_hours",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"motion_detect_wind_active",
"motion_detect_wind_mode",
"mute_once",
"power_watts",
"tropical_night_mode"
]
}
@@ -1,18 +1,27 @@
{
"state_keys": [
"air_filter_status",
"air_filter_threshold",
"air_filter_usage",
"air_filter_usage_hours",
"air_purify",
"alarm_code",
"auto_clean",
"clean_level",
"climate",
"current_temperature_c",
"display_light",
"dust",
"energy_kwh",
"energy_saved_kwh",
"fine_dust",
"firmware_update",
"humidity",
"mute_once",
"selfcheck_error",
"selfcheck_result",
"selfcheck_status"
"selfcheck_status",
"super_fine_dust",
"tropical_night_mode"
]
}
+6 -1
View File
@@ -1,13 +1,17 @@
{
"state_keys": [
"air_filter_status",
"air_filter_threshold",
"air_filter_usage",
"air_filter_usage_hours",
"air_purify",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_limit_enabled",
"current_limit_level",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
@@ -15,6 +19,7 @@
"mute_once",
"selfcheck_error",
"selfcheck_result",
"selfcheck_status"
"selfcheck_status",
"tropical_night_mode"
]
}
@@ -0,0 +1,20 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"air_filter_usage_hours",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts",
"tropical_night_mode"
]
}
@@ -0,0 +1,20 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"air_filter_usage_hours",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts",
"tropical_night_mode"
]
}
+7 -1
View File
@@ -2,12 +2,18 @@
"state_keys": [
"air_filter_status",
"air_filter_usage",
"air_filter_usage_hours",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts"
"power_watts",
"tropical_night_mode"
]
}
+24
View File
@@ -0,0 +1,24 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"air_filter_usage_hours",
"air_purify",
"alarm_code",
"auto_clean",
"beep",
"clean_level",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"dust",
"energy_kwh",
"fine_dust",
"humidity",
"odor",
"power_watts",
"super_fine_dust",
"tropical_night_mode"
]
}
@@ -0,0 +1,25 @@
{
"state_keys": [
"air_filter_status",
"air_filter_threshold",
"air_filter_usage",
"air_filter_usage_hours",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"overload_protection_active",
"overload_protection_mode",
"selfcheck_error",
"selfcheck_result",
"selfcheck_status",
"tropical_night_mode"
]
}
+22
View File
@@ -0,0 +1,22 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"air_filter_usage_hours",
"alarm_code",
"auto_clean",
"beep",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts",
"selfcheck_error",
"selfcheck_result",
"selfcheck_status"
]
}

Some files were not shown because too many files have changed in this diff Show More