Geunwon Mo 618fc5fa51 Add x.com.st.d.hood to _OIC_TYPE_TO_KEY, and document why oic.d.cooktop is not
Measured on nine Samsung appliances on Korean-market firmware, every one of
which populates /oic/d with a concrete type:

    4x  oic.d.airconditioner   AJ023CN1UBC1 system A/C, "Samsung System A/C"
    3x  oic.d.refrigerator     "[refrigerator] Samsung"
    1x  oic.d.cooktop          TP1X_DA-KS-COOKTOP, "Samsung Cooktop"
    1x  x.com.st.d.hood        AHD-WW-TP1-22-COMMON, "Samsung Hood"

Every one agreed with what for_device_by_model already concluded from the board
token, so this is corroboration rather than a correction.

`x.com.st.d.hood` was the one type with a registry to point at and no row, so
this adds it.

`oic.d.cooktop` is left out on purpose, with a comment saying why: the induction
above reports it, but `cooktop` and `induction_cooktop` are unrelated registries
that happen to share the English word, and the OCF type cannot tell them apart.
Mapping it to either key would misroute the other, and since resolve() consults
this table first it would override a COOKTOP/CT board token that had it right.
Same shape of argument as the existing oic.d.robotcleaner note.

One incidental data point on the docstrings' "only ever helps a minority of
dumps": that may understate it. Nine out of nine here answer /oic/d with a usable
type, across four families. Not enough hardware to generalise from, but enough
that it looks less like a rare bonus than the comments assume.

Verified: the full suite passes (1024 tests, Python 3.13 via
requirements-dev.txt).
2026-08-01 09:02:49 +09:00
Marc Billow 6166f63570 Merge pull request #224 from mbillow/claude/issue-triage-batch-h4n2wq
Issue triage batch: #207, #189, #208, #181/#183, #196, #210 + contributing docs
2026-07-31 15:22:55 -05:00
Marc Billow b7d3f86ec7 fix: address code review feedback on issue-triage batch PR (#181, #183, #189, #196, #207, #208, #210)
common:
- Make KIDS_LOCK_GENERIC also a read-only BinarySensorDesc (device_class='lock'),
  flipping value_fn to not bool(v) so /kidslock/0 value=False and
  /kidslock/vs/0 kidsLock='Ready' render with the same polarity ('On'
  means open/unlocked per HA's lock device class). The old SwitchDesc
  form never honored device_class='lock' -- HA's switch platform only
  accepts 'outlet'/'switch' -- so the surface was a plain switch whose
  'On' meaning drifted across boards. Tests updated.

air_monitor:
- Add state_class='measurement' to dust/fine_dust/super_fine_dust so
  the readings feed HA long-term statistics (co2 already had it).
- Import _AIR_QUALITY_SENSORS from air_purifier instead of duplicating
  it byte-for-byte; update common.sensor_item_value's docstring to
  mention the third caller.

by_type/__init__: drop trailing whitespace on the new 'ASM' line.

translations/en.json + nl.json: move the new 'dnd' switch entry to its
correct alphabetical position (after display_light, before fast_preheat).

SKILL.md: add an explicit read-side rule to §5's educated-guesses
section -- guessed unit/device_class/state_class on a SensorDesc
silently mislabels readings forever with no 4.xx to catch it (unlike
guessed writes, which the device rejects). The prior air_monitor
docstring cited this carve-out as if it existed; now it does.

tests/water_purifier (issue #196): change the ailite fixture's
favorite.defaultTemperature from '85' to '50' so the test actually
reproduces the reported bug -- '50' is in showList only, so a
descriptor reading from supportedList would fail the assertion that
the current default is in its options list.
2026-07-31 15:17:18 -05:00
Marc Billow fd86c54f18 Merge pull request #233 from pedrodivisez/feat/ac-odor-controller-cs-translation
AC: bind SmartCoolClean odor-controller tokens; add Czech translation
2026-07-31 14:49:26 -05:00
Jelle Lauwers 9ab3c5827c Rename finish_time debounce -> hysteresis to match actual behavior
The gate holds finish_time at its last reported value until a new one
differs by at least a configured number of minutes, regardless of how
long that difference has been building up -- a magnitude-based deadband,
not a time-based debounce (which would wait for the value to stay put for
N minutes before accepting it). debounce invited the wrong mental model
for anyone reading the option name or the code later, so rename it
throughout before the option name ships: CONF_FINISH_TIME_DEBOUNCE_MINUTES
-> CONF_FINISH_TIME_HYSTERESIS_MINUTES, SensorDesc.debounce -> hysteresis,
LocalThingsSensor._debounce/_debounced_value -> _apply_hysteresis/
_hysteresis_value, and the options-flow data key/translations to match.
2026-07-31 20:27:48 +02:00
Jelle Lauwers d90562017f Add configurable finish_time debounce to cut recorder churn further
Minute-rounding stopped identical values from re-logging, but finish_time
still updates on nearly every poll because now() + remaining is a
continuously-drifting value between the device's own remaining-time
revisions, and washers/dryers/dishwashers commonly revise that estimate
by a minute or two mid-cycle anyway -- both are real, small changes that
individually don't matter but each cost a recorder/logbook entry.

Add a per-device Options Flow setting (finish_time_debounce_minutes,
default 3) and a SensorDesc(debounce=True) opt-in. LocalThingsSensor now
caches the last value it actually reported and only adopts a new one once
it differs by at least the configured threshold, a cycle starts (no prior
cache), or a cycle ends (new value is None) -- 0 disables it entirely,
restoring today's behavior.

Also pass config_entry explicitly into DataUpdateCoordinator's
super().__init__() -- self.config_entry previously relied on an
undocumented ContextVar fallback that upstream has flagged as removed in
HA 2026.8, which the new debounce lookup needed to not be built on top of.
2026-07-31 19:25:45 +02:00
Jelle Lauwers fe9a1128ea Round finish_time to the minute to stop recorder spam
_finish_time added datetime.now(timezone.utc) (fresh seconds/
microseconds every call) to the device's remaining-time duration, so the
returned timestamp differed at the sub-minute level on nearly every poll
even when remainingTime itself hadn't changed. The recorder logged a new
history/logbook entry each time, while the UI rounds the display down to
the minute, making repeated polls look like duplicate identical entries.

Round the result down to the minute so the entity only changes state
when the estimate actually shifts.
2026-07-31 19:07:24 +02:00
Petr Divis f15ee7e563 Update golden fixtures for the new odor-controller entities
CI caught it: 8 pre-existing AC fixtures also carry genuine SmartCoolClean_/
ProgressSmartClean_ tokens in /mode/vs/0 (lnx_rac_heatpump, ara_ww_tp1_22,
windfree_oscillation, tp1x_rac_01001, fac_bora, fac_bora_2in1,
fac_bora_205_flat, cac), so odor_controller_active/odor_controller_progress
now correctly bind there too -- their golden state_keys lists just hadn't
been regenerated. Verified against the actual downloaded CI job log.
2026-07-31 16:39:08 +02:00
Petr Divis d0c68fb5ac AC: bind SmartCoolClean odor-controller option tokens; add Czech translation
- airconditioner.py: odor_controller_active binary_sensor + odor_controller_progress
  sensor, read from the /mode/vs/0 SmartCoolClean_/ProgressSmartClean_ option tokens
  (SmartThings cloud custom.airConditionerOdorController capability). Read-only --
  no confirmed write command.
- Reporter's TP1X_DA-AC-RAC-01001_0000 dump: fan speed and WindFree preset already
  bind via the existing composite climate entity, no code change needed there.
- en.json/nl.json: new entity names for the two additions.
- cs.json: new, full Czech translation catalog (mirrors en.json topology 1:1).
- New fixture + golden + tests locking in the odor-controller behavior.
2026-07-31 16:02:13 +02:00
Marc Billow a7d57086e9 feat: add Samsung Air Monitor Plus support (#210)
New device family: a standalone, battery-powered air-quality sensor
puck (ASM-KR-TP1-22-* board) with no controllable-appliance state at
all -- no /power/*, only /energy/battery/vs/0. Routes via both /oic/d
('x.com.st.d.airqualitysensor', confirmed against the real dump) and
the 'ASM' modelNum board token as a fallback.

/sensors/vs/0 reuses air_purifier.AIR_QUALITY's existing {type, value}
items-list decode (common.sensor_item_value) for dust/fine_dust/
super_fine_dust/odor/clean_level, sharing those capabilities' catalog
entries, and adds a CO2 reading those families don't report. The
particulate sensors deliberately get no pm10/pm25/pm1 device_class:
the values read as physically consistent (coarser >= finer) but
Samsung's own two-tier dust naming doesn't confirm where this board's
three-tier split actually maps, and mislabeling a read-side unit is a
standing, not one-shot, kind of wrong -- exposed as plain named
sensors instead. Humidity, battery/charging, and the informational air
quality standard are otherwise straightforward field reads.

/dnd/vs/0 (do-not-disturb window) is a flagged educated guess: the
write contract mirrors the read side's own string/time-format shape
(the safest kind of guess) but has no idle-vs-active dump to confirm
it end-to-end, so it's called out as such in code and will need a
reporter to verify on real hardware. /keepnormalstate/vs/0 and
/sensordatasinks/vs/0 are genuinely opaque (single unexplained value,
no supported-values list) and are ignored rather than guessed at.

Locked in with a scrubbed fixture, golden, and capability tests.
2026-07-31 02:40:02 +00:00
Marc Billow 4d4de23fbb fix(water_purifier): read favorite-temp options from showList (#196)
favorite_hotwater_temperature's options_field read
favorite.supportedList, which is only the four fixed presets. The
SmartThings app also lets the user add one custom value to their own
display list via its "temperatures to display" editor (bounded by
/setting/waterpurifier/vs/0's hotwaterRange), and that value shows up
in favorite.showList but never in supportedList. A unit whose current
default was that custom value rendered as HA's "unknown" state, since
current_option wasn't among the (too-narrow) options list.

showList is a superset of supportedList that always includes whatever
the current default actually is. /setting/waterpurifier/vs/0's own
hot_water_temperature select is untouched -- its write contract for
values off the old preset list still isn't confirmed, so it stays
gated off on boards that don't report supportedHotTemperatures.
2026-07-31 02:14:09 +00:00
Marc Billow e46e935ba0 fix(common): make the vendor kids-lock fallback read-only (#181, #183)
KIDS_LOCK_VS_FALLBACK's write_fn wrote 'Enable', a value no dump in the
fixture corpus (washers, dryers, dishwashers, ovens, ranges, microwaves,
air purifiers, air dressers -- everything that lacks the OCF-standard
/kidslock/0) has ever reported back; every one reports 'Ready' or 'Run'.
It was never a confirmed write contract.

#181's reporter tested directly: writing the *correct* value ('Run')
still returns 4.05, and the SmartThings app itself has no control for
kids lock either -- the resource is genuinely read-only on that
hardware, not just wrong-valued. #183's reporter hit the identical
symptom (toggle does nothing) on a different device family reporting
the same Run/Ready vocabulary.

Convert the entity to a read-only BinarySensorDesc. binary_sensor's
'lock' device class is inverted from the old switch reading (On means
open/unlocked), so value_fn flips accordingly -- callers reading the
flattened 'child_lock' state key need to account for the new polarity.
KIDS_LOCK_GENERIC (the OCF-standard /kidslock/0 boolean) is untouched;
nothing suggests that one is broken.
2026-07-31 02:09:58 +00:00
Marc Billow 5bbc7aeece fix(air_dresser): bind /buzzersound/vs/0 on the TP1_21 board (#208)
DA_DF_TP1_21_COMMON reports a plain {setBuzzerSound, supportedFinishSound}
buzzersound resource -- the same shape laundry.BUZZER_SOUND already
handles for washers/dryers -- but it was unbound because the air_dresser
registry never included that capability. Add it, and lock the board in
with a scrubbed fixture, golden, and capability tests.

The reporter's actual complaint (course cycles showing as raw codes) is
a labelling gap, not a coverage one: this board's course table has no
code->name mapping anywhere in the dump, same as issue #162's board, so
there's nothing to bind here -- it needs a reporter to identify the
codes before they can be named in translations.
2026-07-31 02:03:32 +00:00
Marc Billow e642db462d fix: recognize all-same-hex-digit placeholder serials (#189)
_is_placeholder_serial only caught the ARTIK051_DONGLE_REF family's
'Nothing(SVC)' sentinel. The DA_WM_A51_20_COMMON (ARTIK051) laundry
board family reports a different one instead -- every character the
same repeated hex digit -- which passed through as a real, non-unique
serial. Two different physical units (a washer and a dryer) both
reporting the literal serialNum 'FFFFFFFFFFFFFFF' collided on the
config-entry unique_id, so the second device's config flow aborted as
already configured. Widen the check (both the config_flow.py and
coordinator.py copies) to also catch that sentinel shape.
2026-07-31 01:59:49 +00:00
Marc Billow b8d04b4ae3 Merge pull request #216 from firstof9/fix-hood-fan-write-fallback
fix(hood_fan): fall back to settable min/max when supportedFanSpeed is missing
2026-07-30 20:21:02 -05:00
Marc Billow 0a4b80afc4 Add OCF-spec-confirmed oic.d types: airpurifier, dishwasher, oven
Extend _OIC_TYPE_TO_KEY with three more device categories the OCF Smart
Home Device Specification defines with the same 'oic.d.<category>' shape
as the already-confirmed entries, ahead of seeing them in an actual dump.
Deliberately leave out the rest of a broader compiled oic.d/x.com.st.d
list (lights, switches, sensors, locks, cameras, TVs, generic energy
meters, oic.d.robotcleaner, ...) -- none of those map to a registry this
integration has, and robotcleaner in particular names a different product
than the vacuum_station clean-station registry.
2026-07-31 00:58:26 +00:00
Marc Billow 4f9e630ae9 Route device type from /oic/d as the primary detection signal
/oic/d's `rt` names the device's own OCF device type, which beats
parsing board part numbers whenever a dump populates it. Add
for_device_by_oic_type() and an _OIC_TYPE_TO_KEY table (airconditioner,
dryer, refrigerator, washer, plus SmartThings' x.com.st.d.stickcleaner
and x.com.st.d.steamcloset extensions), and consult it first in
resolve(), ahead of modelNum/description and the resource-signature
fallback.

Thread the master's device_types from read_identity() through
coordinator.py's discovery pass and config_flow's connection probe;
subdevices keep resolving from their own /information/vs/0 (or the
master's registry as a fallback) since they have no /oic/d of their
own read today.
2026-07-31 00:56:17 +00:00
firstof9@gmail.com 8e8f08109a fix(hood_fan): fall back to settable min/max when supportedFanSpeed is missing 2026-07-30 11:33:40 -07:00
Marc Billow 5e86f147d4 fix(subdevices): don't materialize a slot whose only live state is a meter
Issue #214: a single-split ARTIK051_KRAC_18K showed up in HA as two air
conditioners. Its /device/1 answers the same unused-slot shape the Pattern A
reporter's /device/2 does -- every operational rep empty {} -- but also
reports a populated /energy/consumption/vs/1. Running discovery against the
reporter's own quoted subdevice block reproduces their diagnostics exactly
(21 bound entities, the same six hrefs), and of those 21 the only primary
entity with a non-None value is energy_kwh: a lifetime kWh total was the
sole thing passing discover_partitioned's liveness gate and materializing
the phantom.

A single-split AC has one compressor and one energy meter, so a
whole-appliance running total appearing under a second index is the
appliance's own bookkeeping, not evidence that hardware is installed at that
slot. Exclude cumulative meters (HA's total/total_increasing state classes,
plus the energy/water/gas device classes for the descriptors that
deliberately declare no state class) from the gate. The gate never applies
to MAIN, and across the whole fixture corpus every device has at least one
non-meter live primary, so no existing device's entities change -- verified
by the golden for the new fixture being identical to the plain KRAC one.

Also implement async_remove_config_entry_device. A subdevice's HA device
outlives the discovery that created it, so a phantom materialized by an
earlier release stays in the registry with no way to delete it from the UI
-- which is the state the second reporter on that issue is in, with a
refrigerator whose diagnostics now report no subdevices at all. Devices the
entry currently provides still refuse removal. No automatic pruning:
enumeration is one-shot and a real sibling can miss a poll (issue #205 on
the reference hardware), so auto-removal would discard a live subdevice's
name, area and automations on a transient miss.

The new fixture's /device/1 seed is the reporter's verbatim capture; its
master half comes from the corpus's other KRAC unit, with the deviations
spelled out in seeds_note.

Claude-Session: https://claude.ai/code/session_01HzUMLnSWBT64o4BQkVEzXp
2026-07-30 18:23:47 +00:00
Marc Billow ca27bf7f6e docs: de-identify reporter usernames repo-wide, add PII rule to skill
Extended the earlier de-identification (jhkwon19) to the other issue #177
reporter (HJcom), who was named in ~20 spots across coordinator.py,
diagnostics.py, subdevices.py, identity.py, capabilities/airconditioner.py,
a fixture's seeds_note, and several test docstrings/function names. Swapped
all of it for "the reporter"/"the Pattern A reporter", matching the
convention already established for the other reporter.

Added a rule to the adding-device-support skill (end of "Lock it in"):
don't put a reporter's name or GitHub username in code comments,
docstrings, seeds_note, or test/function names -- that prose ships and
sits in git history indefinitely, unlike an issue thread or a
release-notes thank-you. Use "the reporter" / "issue #NNN's reporter" /
a pattern label instead.
2026-07-30 03:06:06 +00:00
Marc Billow ce92d71a92 docs: de-identify the reporter's username in code comments
Comments/docstrings across subdevices.py, coordinator.py, the two fac_bora
fixtures, and their tests named the issue #177/#205 reporter directly.
Swapped to "the reporter"/"the Pattern B reporter" throughout -- no
behavior or test-assertion changes, string content only. HJcom (the
Pattern A reporter) is unaffected.
2026-07-30 02:50:49 +00:00
Marc Billow 8600985a36 review: address Opus findings on the subdevice flat-href fallback
- coordinator: _poll_subdevice_flat_hrefs called sess.pace() outside its
  try block and re-read self._session instead of using the caller's
  already-None-checked reference -- a session closed mid-poll (async_close()
  doesn't hold _session_lock) could crash the whole poll cycle instead of
  just dropping that one sibling. Now takes sess from the caller and guards
  pace() the same as get().
- coordinator: skip flat hrefs already covered by the hot/warm sub-poll
  tiers -- those are refreshed every few seconds by _run_subpolls already,
  so re-fetching them again on the once-per-summary-poll flat pass only adds
  GETs, not freshness. Matters because, unlike the Collection path (always
  one GET), a flat subdevice's summary-poll cost scales with its href count.
- subdevices.py module docstring: corrected an overclaim inherited from PR
  #199 that GET /<uuid>/device/0 had been "confirmed live" on jhkwon19's
  unit. Only an individual /information/vs/0 read was ever actually
  confirmed; the Collection endpoint itself has never been observed to
  answer on any known unit, which is exactly what issue #205 exposes.
- SKILL.md: fixed the numofsubdevice cross-check formula to match what
  coordinator.py actually compares (len(materialized) + 1, not
  len(subdevices) + len(subdevices_skipped)).
- Documented, not yet guarded against: a firmware that echoes state back
  under any unrecognized prefix instead of 4.04ing could pass the flat probe
  and the liveness gate, materializing a phantom duplicate of the master.
  Every board seen so far genuinely 4.04s on paths it doesn't own.
- Added test coverage the review flagged as missing: a materialized (not
  just skipped) flat subdevice re-polling end-to-end through to
  canonical_resources, the hot/warm skip itself, zero-master-hrefs and
  two-UUID no-cross-contamination edge cases, and a golden file for the
  #205 fixture (SKILL.md's "fixture + golden + test" discipline).
2026-07-30 02:44:26 +00:00
Marc Billow e78d941af3 fix(subdevices): fall back to per-href probing when a prefixed subdevice has no /device/0 Collection
Issue #205 shows the UUID-prefixed pattern's own reference device
(TP2X_FAC_BORA_21K) doesn't always answer /<uuid>/device/0, contrary to
what the pattern was built against. When that Collection GET comes back
empty, enumerate_subdevices now probes every href the master itself
answered this cycle individually under the UUID prefix, keeping whichever
ones respond. Subdevice gains a flat_hrefs field for this, and the
coordinator re-polls those hrefs individually each cycle instead of
re-fetching a Collection batch that doesn't exist.

Built a fixture from the reporter's real #205 diagnostics dump: the
fallback finds a candidate through the one href already confirmed live
under this UUID (/information/vs/0, from the #177 thread), and
discover_partitioned's liveness gate correctly holds it back since that
href alone binds no entity -- honest current state, not a guessed
resolution.
2026-07-30 02:25:26 +00:00
Marc Billow fb2d267632 fix(water_purifier): route AILITE_DA-REF-WATERPURIFIER boards correctly (#196)
The AILITE water-purifier board (RWP70F15ANW) spells its modelNum
'...-REF-WATERPURIFIER-...', so the board-token scan hit the bare 'REF'
token before ever reaching 'WATERPURIFIER' and misrouted the device to
the refrigerator registry, whose resource surface shares almost nothing
with a water purifier -- hence the incomplete-coverage warning. Add a
documented carve-out for this one token co-occurrence and a matching
TestBoardTokenAmbiguity exception.

Also bind the water-purifier hrefs this board additionally exposes:
cup-detection status, the settings/sound/{mode,output,volume} trio (read
live, since this board's own supportedModes vocabulary differs from both
laundry's and air_purifier's hardcoded/live sets), and last-pour
statistics.

Separately, gate hot_water_temperature off when the device doesn't report
a supportedHotTemperatures list (only a hotwaterRange/hotwaterLevel pair
with no confirmed write contract) -- previously an empty options list
plus a live current value rendered as 'unknown' in HA, the second bug
reported in #196. The existing water_purifier_coffee fixture (#107) turns
out to hit the same shape, so its golden drops the entity too.

Issue #195 (TP1X_REF_21K) needed no change: its diagnostics show zero
unbound hrefs and the model already routes to the refrigerator registry,
matching the maintainer's own comment on the issue.
2026-07-29 23:23:56 +00:00
Marc Billow 1053ae421b Merge pull request #202 from firstof9/fix/fan-zerodivision-issue-201
fix(fan): fall back to settableMin/MaxFanSpeed when supportedFanSpeed is omitted (#201)
2026-07-29 18:06:41 -05:00
Marc Billow 9e85395b44 rename: unit/sub-unit -> subdevice, matching OCF terminology
"Unit"/"sub-unit" from #199's multi-indoor-device support wasn't OCF
idiomatic -- OCF calls each component of a composite device a
"subdevice" (see subdeviceIdList), so rename SubUnit -> Subdevice
throughout: the registry module, coordinator state, BoundEntity's
subdevice field, diagnostics keys (subdevices/subdevices_skipped/
subdevice_probes), entity unique_id prefixes (unit1_/sub_<uuid>_ ->
subdevice1_/subdevice_<uuid>_), device-name fallback labels, golden
fixtures, tests, README, and the adding-device-support skill.

Breaking change to entity unique_ids and diagnostics keys, acceptable
since this hasn't been released yet.
2026-07-29 22:57:11 +00:00
firstof9@gmail.com bc667e486c fix(fan): fall back to settableMin/MaxFanSpeed when supportedFanSpeed is omitted (#201)
Fixes ZeroDivisionError in fan platform when supportedFanSpeed is missing on microwave vent fans (e.g. ME8000T).
2026-07-29 15:50:15 -07:00
Marc Billow 9442248c20 Merge origin/main into multi-device sub-unit support
Conflict was purely additive: both sides appended golden-regression
tests at the same point in the file, and each side's last test shared
the single trailing assert block. Kept every test from both sides, each
with its own copy of that assert.

One real semantic merge on top of that. #136 (on main) remodelled the
legacy ARTIK051 board's beep from a buzzer_volume Number to a beep
Switch, and HJcom's ARTIK051_DONGLE_FAC_18K is exactly that board
generation (is_legacy_board -> True), so its golden -- written before
that change existed -- still expected buzzer_volume. Regenerated it:
buzzer_volume/unit1_buzzer_volume -> beep/unit1_beep on the master and
the second indoor unit alike, with nothing else moving and still no
unit2_ keys. That is main's intended behavior reaching the sub-unit for
free, which is the point of binding siblings through the same registry.

967 passing. Re-ran the corpus-wide unique_id audit over all 57
fixtures (main added five this branch had never seen): no collisions
within a platform.
2026-07-29 19:40:32 +00:00
Marc Billow c181a8b447 feat(subdevices): support multi-indoor-unit systems (#177)
Samsung 2-in-1 air conditioners put more than one logical indoor unit
behind a single IP and a single DTLS session. Only the unit the config
entry was set up against was ever discovered; the second one -- a whole
physical appliance the user can see in SmartThings -- had no entities at
all. Two reporters turned out to have two different mechanisms:

  ARTIK051_DONGLE_FAC_18K -- indexed siblings. /oic/res registers the
  whole tree discoverable and lists three complete parallel resource
  sets whose trailing path segment is the index (/mode/vs/0, /mode/vs/1,
  ...), on OCF-standard and vendor hrefs alike. /device/0's batch
  carries only the index-0 hrefs, so a sibling is reachable only through
  its own /device/<n> collection.

  TP2X_FAC_BORA_21K -- UUID-prefixed tree. /oic/res hides the appliance
  tree entirely (which is why a direct /device/1 probe returns nothing
  on this board). /subdevices/vs/0 carries subdeviceIdList instead, and
  that UUID appears as a literal href prefix; /<uuid>/information/vs/0
  was confirmed live to return the wall unit's own model and serial
  (TP2X_FAC_BORA_RAC_21K) against the master's TP2X_FAC_BORA_21K.

The detection signals don't overlap on either board, so no
disambiguation is needed -- enumeration checks both and takes what
answers.

Both patterns are the same thing underneath: a logical unit is a seed
collection path to poll plus an href transform between the canonical
href the registry knows and the actual on-the-wire href. That is the
whole abstraction (SubUnit), applied at four boundaries -- discovery,
the coordinator, the adapter, and the platforms. Capabilities, the
registry and the climate composite stay written against canonical hrefs
and are untouched.

Uniqueness comes from a key_prefix inside the flattened state key, so
the master unit's keys are byte-identical to every release before this
and every existing golden file is an unchanged regression guard. Each
sub-unit gets its own device-registry entry linked by via_device and
named from its own /information/vs/<n>, so it lands in its own room
rather than crowding the master's device page.

A sub-unit materializes only when it yields at least one primary
(non-diagnostic) entity with a populated value. That gate is not
decoration: the reporter's /device/2 is an unused slot that SmartThings
shows disabled, yet it answers with a full 14-href batch, and it
flattens to exactly one non-None value -- a diagnostic alarm_code
derived from an empty /alarms/vs/2. Without the entity-category filter
it becomes a phantom third climate card. The rule is deliberately
domain-agnostic rather than a list of HVAC hrefs, so a multi-drum
washer (#19) gets the same treatment with no new curation. Units that
answer but fail the gate are logged and reported in diagnostics, so a
genuinely missing unit stays diagnosable from a dump.

Enumeration fetches things that must not then be treated as appliance
state. A rejected candidate's seed has to be read to evaluate the gate,
but only units that pass are polled again, and StateCache has no
eviction -- so discovery runs before the first cache apply and those
reps are held aside for diagnostics rather than frozen into the cache
forever. /multidevice/vs/0 is probed on every device regardless of
family, so merging it into the resources dict would have reached
discovery on any board whose registry doesn't ignore that href -- only
the air conditioner one does -- raising a spurious coverage-gap repair
for a washer or fridge whose firmware answers it. It is corroborating
metadata (numofsubdevice, confirmed read-only) and now lives beside the
resources rather than in them.

Diagnostics reports each unit separately: top-level `resources` is this
unit's own and only its own, which is what the module docstring and the
adding-device-support skill have always claimed it was, and each
sibling or rejected candidate carries its own reps canonicalized so a
block reads exactly like the master's instead of needing to be
de-indexed by hand.

Fixtures are real captures. The ARTIK051_DONGLE_FAC_18K one is entirely
verbatim, both sibling seeds and the hand-read /multidevice/vs/0
included. The TP2X_FAC_BORA one has a real device0, oic_res and
sub-unit /information/vs/0, with the remainder of that unit's tree
constructed and documented as such in seeds_note; /<uuid>/device/0 is
the one part of that pattern still inferred rather than observed, and
can't be tested through the debug panel because a Collection returns a
list.
2026-07-29 19:14:51 +00:00
Marc Billow bd3ca80d3c review: address Opus code-review findings on this branch
- config_flow: the #192 port-rescue made the "every port refused" fast-fail
  permanently unreachable (PREFERRED_PROBE_PORTS is always non-empty and
  always rescued), so removed the dead branch instead of leaving it as
  misleading dead code. A dead host now fails via the handshake loop's own
  error, which carries the real per-port reason.
- oven._has_option: added the is_stub_rep carve-out cooktop.py's identical
  per-token exists_fn already has on the same kind of href, so a not-yet
  sub-polled /mode/vs/0 doesn't permanently exclude energy_saving/
  cooktop_on_alert before their first real fetch lands.
- airconditioner.ENERGY_METER_LEGACY: build via dataclasses.replace() like
  its ENERGY_METER_GENERIC sibling, instead of hand-copying href/poll_tier
  (which would silently drift if common.ENERGY_METER ever gains a field).
- Fixed two stale comments: is_legacy_board()'s docstring still listed
  Volume among tokens needing legacy-only gating, though 'beep' now applies
  unconditionally across board generations; and common.py's UNIVERSAL
  invariant comment didn't mention that airconditioner also now excludes
  ENERGY_METER from the wholesale bundle.
- #191 (CAC token): added the fixture/golden/capability-test coverage the
  AVT token in the same branch got, including an honestly-documented list
  of the ten hrefs this board generation doesn't cover yet.
- fridge.cooler_temperature_setpoint: dropped the hardcoded "N °C" state
  labels -- the resource's own unit field isn't necessarily Celsius on a
  different model reporting the same href, and the options themselves are
  already read live via options_field, so a static per-value label risked
  asserting the wrong unit for a future device sharing this capability.
- airconditioner._legacy_cumulative_power_kwh: parse with float (matching
  common.wh_to_kwh's own numeric parsing) instead of this module's
  integer-only _int, so a decimal-formatted reading doesn't raise.
- test_config_flow: the port-rescue test bound the real 49154 directly,
  which could collide with an actually-running service on some machine;
  now monkeypatches PREFERRED_PROBE_PORTS to an OS-assigned port instead.
- oven.py: consolidated six byte-for-byte-identical single-token options
  write_fns (lamp/sound/fast_preheat/natural_steam/energy_saving/
  cooktop_on_alert) into one _option_switch_write(prefix) factory.

845 tests passing (up from 841 -- 4 new CAC coverage tests).
2026-07-29 18:04:23 +00:00
Marc Billow a003650d31 perf(common): poll power state on the warm tier (#56)
/power/0 and /power/vs/0 had no poll_tier, so they only ever refreshed on
the once-per-30s summary poll -- everything else that drives real-time
switch/climate/fan state (e.g. remote-control enablement) is already on
the faster subscribe/subpoll 'warm' cadence for exactly this reason. Scoped
to just this one tier bump; the model-specific priority-flip claim in the
same issue thread isn't independently verified, so it isn't part of this
change.
2026-07-29 13:33:26 +00:00
Marc Billow 36240b44e6 fix(oven): gate fast_preheat/natural_steam on their own tokens (#183)
Both switches were shipped unconditionally (no exists_fn) as an unverified
guess -- the module docstring already flagged them as "unproven." Every
range/oven fixture in the corpus, including the new issue #183 dump,
reports neither fastpreheat_* nor NaturalSteam_* in /mode/vs/0's options at
all, so both were phantom controls: always read as off, and toggling them
wrote a token the firmware never recognized in the first place. That
matches the reporter's exact complaint ("doesn't appear to do anything").

Also bound two tokens confirmed present on this dump but never modeled at
all: EnergySaving_On (the 120-hour energy-saving standby from the app) and
BurnerOnAlert_Off (cooktop-on alert), following the same single-token
options-merge pattern as the existing lamp/sound/fast_preheat switches.

Child lock, the setpoint mismatch, and the missing cook-start control from
this issue are not code bugs -- see the issue comment for what was verified
and what still needs more information from the reporter.
2026-07-29 13:26:39 +00:00
Marc Billow 487ac748bd fix(airconditioner): model legacy-board beep as a switch, not a volume (#136)
Every ARTIK051_KRAC_18K-generation unit confirmed on hardware (three units
across two reporters) only ever carries Volume_100 or Volume_Mute in
/mode/vs/0's options -- never an intermediate value -- so the existing
buzzer_volume Number (0-100, step 10) modeled a control this firmware
doesn't have. Worse, its write path could never produce the literal
'Mute' token needed to actually turn the beep off, since it only ever
wrote a plain integer string. The 'beep' switch already used on newer
boards is the correct model here too; it's no longer gated off the legacy
board generation, and the Number entity is removed.

The WindFree-preset-not-applying report earlier in this issue self-resolved
per the reporter's own follow-up testing, so no code change was needed for
that part.
2026-07-29 13:16:09 +00:00
Marc Billow b5c5c056f4 feat(fridge): expose discrete cooler temperature setpoint (#186)
RT42DG6630B1FZ is a single-door "cooler only" fridge that reports its
setpoint on /temperature/definite/cooler/vs/0 -- a vendor resource outside
both TEMP_CURRENT_GENERIC's '/temperature/current/' and TEMP_SETPOINT's
'/temperature/desired/' href prefixes, so it was entirely unbound and the
setting stayed app-only. Its supportedList (1/2/3/4/7 °C) isn't a
contiguous range, so this is modeled as a select over the device's own
live options rather than a NumberDesc that would let a user pick an
unsupported value like 5 or 6.
2026-07-29 13:11:07 +00:00
Marc Billow 74f34b91a5 feat(registry): route AVT-WW-TP1-23 air purifier boards (#190)
AVT-WW-TP1-23-AXX500 (AX053B810HGD) reported device_type 'unknown' with
empty oneUiVersion, falling back to common caps. It's the same BESPOKE
Cube Air lineage as A-VTWW-TP2-21-COMMON (issue #151), just with the
'-WW-' delimiter shifted one letter left ('A-VTWW-' -> 'AVT-WW-'), which
splits into an 'AVT'/'WW' token pair the existing whole-token 'VTWW' entry
can't see. Added 'AVT' as its own board token onto the same air_purifier
registry -- the resource surface (wind/strength fan, HEPA filter, air
quality sensors, alarms) already matched with zero unbound hrefs once
routed there, so no new capabilities were needed.
2026-07-29 13:06:36 +00:00
Marc Billow d83733a670 fix(airconditioner): scale legacy ARTIK051 cumulativePower correctly (#193)
ARTIK051_KRAC_18K-generation boards report /energy/consumption/vs/0's
cumulativePower in centiwatt-hours, not the plain Wh every other AC board
family reports -- confirmed against the reporter's own SmartThings-app
reading (raw 117430000 vs. the app's authoritative 1,174.30 kWh is exactly
a /100000 factor, not the shared wh_to_kwh's /1000 alone). Split
common.ENERGY_METER into generic/legacy variants on the airconditioner
registry, discriminated by the existing is_legacy_board() check, so every
other AC family keeps the unmodified shared capability.
2026-07-29 13:04:33 +00:00
Marc Billow e8df8f7b0c fix(config_flow): always retry historically-confirmed DTLS ports (#192)
The liveness sweep's ICMP-based verdict isn't trustworthy on every network
path -- a segregated-VLAN report showed it calling three closed ports live
while missing the one port a concurrent nmap scan found genuinely
open|filtered, which also happened to be one of our two historically
confirmed DTLS ports. Rather than trust a "not live" verdict against that
prior, always give PREFERRED_PROBE_PORTS a real handshake attempt even when
the sweep excludes them, bounded to at most those two extra attempts.

This is a stop-gap for the reported failure mode, not a full fix for the
sweep's underlying unreliability -- left a comment on the issue with the
diagnosis and flagged the sweep itself for a deeper redesign.
2026-07-29 12:53:56 +00:00
Marc Billow 7fe9e2a975 fix(registry): route TP1X_DA-AC-CAC boards to airconditioner (#191)
The 0.16.0 device-type simplification dropped oneUiVersion detection on
the assumption every device it typed was already reachable via a modelNum
board token. Cassette AC units (TP1X_DA-AC-CAC-01001_0000) were the one
exception -- they only ever resolved through oneUiVersion's "Air
conditioner" string, since 'CAC' was never added to the board-token
table -- so they silently fell back to common caps and lost their
climate entity.
2026-07-29 12:50:21 +00:00
Marc Billow 10d5c81d9a feat(diagnostics): speculatively probe /device/1 and /device/2
/oic/res's baseline-Interface response only lists resources with the
discoverable policy bit set, and a real dump (issue #177 follow-up,
TP1X_REF_21K) confirms /device/0's whole x.com.samsung.da.* tree is
registered without it -- so a second logical Device's Collection, if
one exists, would be just as invisible to /oic/res as /device/0 is.
Probe /device/1 and /device/2 directly instead: a plain non-mutating
RETRIEVE, tolerated-404 same as every other speculative read in this
module. Parsed with the same parse_device0_batch used for /device/0
itself, and folded into identity.raw so diagnostics can tell "checked,
found nothing" apart from "never checked".
2026-07-29 04:08:19 +00:00
Marc Billow 0c8d39fb73 feat(diagnostics): capture /oic/res discovery links
/oic/res is OCF's baseline resource-discovery endpoint: a unicast
RETRIEVE returns every href/Collection the connection hosts, not just
the one /device/0 seed path the coordinator polls. Relevant to the OCF
"Composite Device" model (issue #177) -- a single physical unit sharing
one IP/session across more than one logical Device, each exposed as its
own Collection resource (same rt shape as our own /device/0). Nothing
routes on this yet; captured alongside the existing /oic/p and /oic/d
reads so a report from a multi-unit device shows us whether its
firmware actually implements that model before any code assumes it does.
2026-07-29 03:53:27 +00:00
Marc Billow a7aea3764b feat(airconditioner): make absence/motion-detect enable switches writable
status on both /mds/absencepowersaving/vs/0 and
/option/motiondetectwind/stateful/vs/0 is a bare On/Off boolean, the same
shape already shipped writable elsewhere in this file (MUTE_ONCE,
AUTO_CLEAN, AIR_PURIFY) without a live-confirmed write either -- worst
case a wrong token no-ops. The paired mode selects (switchPowerSaveMode,
motion-detect modes) stay read-only: their behavioral effect on live HVAC
isn't inferable from the dump, same reasoning as ANOMALY_LOAD's mode field.
2026-07-29 03:34:18 +00:00
Marc Billow a6eb1c62d4 feat(microwave): add filter reminder / end signal reminder switches (#181)
Both FilterRemind_*/RemindBeep_* option-array tokens are already
present -- and both On and Off already confirmed -- on the existing
ME7500D fixtures (issue #152), so this is a straight sibling of the
Sound/Lamp switches rather than new discovery work. Gated with
exists_fn like Lamp since the MW7300B combi dump has neither token.

Doesn't address the rest of issue #181 (power-level slider,
non-reported cooking modes, 3-level light, child lock, send-to-
microwave) -- those need write-contract confirmation this dump
doesn't carry.
2026-07-29 02:55:47 +00:00
Marc Billow 2b24152276 feat(registry): cover absence-power-saving and motion-detect-wind on AC (#173)
Lennox-branded heat pump on the Samsung RAC board family (modelNum
TP1X_LNX-AC-RAC-01001_0000) already routes correctly via the existing
'-RAC-' token, but its dump has two resources no prior AC fixture
carried: /mds/absencepowersaving/vs/0 and
/option/motiondetectwind/stateful/vs/0. Bind both as read-only
sensors, matching the CURRENT_LIMIT/ANOMALY_LOAD precedent -- nothing
in the dump confirms write safety on live HVAC hardware.
2026-07-29 02:52:33 +00:00
Marc Billow c9620b47b3 fix(diagnostics): redact the OCF device name; log description on unknown type
Two things a review of this branch turned up.

/oic/d's `n` is free text the owner sets from the SmartThings app, so it may
carry a person's name. Nothing in the /device/0 dump has ever exposed it --
it only became reachable when diagnostics started reporting /oic/d earlier
in this branch, which would have started carrying it into public issue
reports. Redact it. `rt`, the device-type signal the block exists for, is
untouched, and no /device/0 resource uses a bare 'n' key, so nothing else
changes.

The unknown-device-type warning logged only modelNum. That line is what a
user pastes into an issue, and modelNum alone can't identify a washer from a
dryer -- both report the shared DA_WM_ laundry board, and detection reads
the consumer-model code out of `description` for exactly that reason. Log
both fields.
2026-07-29 02:20:37 +00:00
Marc Billow cafd7d5afa refactor(registry): drop oneUiVersion from device-type detection
oneUiVersion looks like the signal you'd want -- the device naming its own
type, '7.0 Dishwasher' -- and it was the first thing detection consulted. It
never earned the position:

- Only 7 of 49 fixtures report it at all.
- All 7 resolve to the same registry from their modelNum board token alone.
- No device-support issue has ever been fixed by adding a mapping for it.
  Every one went through modelNum. The alias keys it needed in
  _REGISTRY_BY_KEY ('airpurifier', 'air_conditioner', 'hood') were
  speculative when the registries were first written and never used since.

So it bought a key-normalizing helper (_type_key), a lookup with a suffix
fallback (for_device), three alias keys, and a second config-flow step whose
only reason to exist was phrasing a sentence about oneUiVersion -- for a
signal that has never once been decisive.

Remove it from detection. It stays in diagnostics, where it's genuinely
useful: it names the firmware generation ('7.0 Air conditioner' is Tizen
Lite), which matters when triaging an issue.

Detection order was also duplicated in four places -- the coordinator, the
config flow's probe, the golden-regression harness, and the skill -- which
is how the harness and the shipped order drift apart. Collapse it into
by_type.resolve(resources), and call that everywhere.

The two "appliance type not recognized" config steps become one. They
differed only in whether they blamed a missing oneUiVersion, which is not a
distinction a user can act on, and never was.

Verified by the full suite (795 passing), including every golden regression
-- so entity output is byte-identical for all 49 device fixtures.

TestOneUiVersionIsNotConsulted locks in the premise rather than just the
outcome: for every dump that reports a oneUiVersion, the model strings alone
must still reach a registry. If a future device breaks that, the test says
so instead of the device silently losing half its entities.

Also note in requirements-dev.txt that Python 3.13 resolves the pinned
harness floor -- 3.12 and older resolve nothing and fail the whole install.
2026-07-29 02:14:13 +00:00
Marc Billow a863df1e59 refactor(registry): match board families by token table, not substring ladder
for_device_by_model() had grown to 21 sequential `if key is None` branches
and 102 comment lines against 59 lines of code -- 33 of the repo's 243
commits have touched this file. Most of that bulk came from one wrong
primitive: substring matching on a delimited string.

Samsung spells the same board family with either delimiter, so '_RAC_' and
'-RAC-' each needed their own rule, and 'ARTIK051_DONGLE_REF' (issues #77,
#83) matched no '_TOKEN_' spelling at all because REF lands at the end of
the pipe-prefix with no trailing underscore -- which is what
_model_num_segments() existed to work around. Which field a rule searched
(modelNum, or modelNum + description) was historical accident. Collisions
like WAC vs WA were resolved by one `if` physically preceding another,
invisible in the code and explained at length in prose.

Tokenize on any non-alphanumeric run, upper-case, and look the tokens up in
a flat table. Every delimiter spelling collapses to one entry, both fields
go through the same matcher in a documented order (modelNum, then
description, then the fuzzy consumer prefix), and specificity is a property
of the table rather than of line ordering.

Two behaviours are preserved deliberately:

- modelNum is matched before description, which is what keeps the legacy
  gas cooktop correct: it reports 'ARTIK051_GB_CT_001' (CT) alongside
  'ARTIK051_GLOBAL_COOKTOP' (COOKTOP, which otherwise means induction).
  It is the only known device whose two fields disagree.
- _consumer_model_key still splits on '_' only. Widening it to '-' would
  read the dishwasher's 'ADW-WW-RTL-24-AILITE' board segment as a bare 'WW'
  washer.

Verified identical: all 49 device fixtures resolve to the same registry
before and after, and every existing for_device_by_model test case passes
unchanged. The table also picks up two families that previously depended on
oneUiVersion alone (TP1X_DA-AC-AIR air purifiers, ADW dishwashers), so they
now survive firmware that omits it.

TestBoardTokenAmbiguity guards the one property the flat lookup needs --
that no real model string contains two tokens naming different device types
-- across the whole fixture corpus, so a newly added dump exercises it
automatically.

The skill gains a section on routing: what each detection stage is for, the
rules for adding a token (name the specific type, never the board family;
never add a delimiter spelling; two-letter tokens are a last resort), when
to reach for the consumer prefix or a resource signature instead, and the
measured stake -- an unrouted device loses roughly half its entities.
2026-07-29 01:57:10 +00:00
Marc Billow 288ba02cc5 feat(diagnostics): capture /oic/p and /oic/d identity
Device-type detection currently parses board part numbers out of
/information/vs/0's modelNum. OCF has a standard field for exactly this
question -- /oic/d's `rt` -- and read_identity() already fetches the
resource, but kept only `n` and threw the rest away. No captured dump has
ever included it either: /device/0 batch responses don't carry /oic/d, and
diagnostics didn't report it, so there's no evidence on whether real
hardware populates it usefully.

Keep `rt` as DeviceIdentity.device_types, keep both raw payloads whole
(we don't yet know which of their fields identify a type), and surface
them in diagnostics so incoming issue reports answer the question.

Nothing routes on it yet.

/oic/d and /oic/p identify the unit with bare two-letter keys -- 'di' and
'pi' -- as sensitive as the serial number redact.py already covers but far
too short to match on: 'di' alone is a substring of 'condition', 'display'
and 'dispenser'. Add a whole-key match alongside the substring rules.
2026-07-29 01:56:52 +00:00
firstof9@gmail.com 1f331f3aa6 fix(registry): route microwaves without /information/vs/0 to microwave registry (#172)
Issue #172: Samsung Microwave units (ME8000T-/AA0) omit /information/vs/0 and have empty oneUiVersion, falling back to unknown device type. Route via /oven/vs/0 and MicroWave modes in supportedModes.
2026-07-28 13:29:57 -07:00
Marc Billow bbf3f3f833 Revert unsound air-quality gating from #170, cover remaining fan-speed icons
An Opus review of merged PR #170 found the cleanLevel-scalar existence
gate on AIR_QUALITY doesn't hold up as a general rule: three fixtures
in this repo (air_purifier_device.json, air_purifier_vtww_device.json,
range_hood_device.json) carry genuinely populated Dust/FineDust/
SuperFineDust readings with no such scalar, so requiring it risks
silently dropping real air-quality readings on AC hardware this repo
hasn't seen yet. Reverted _has_sensor_type to item-type presence only
(as before #170) and moved the #166 fix to enabled_default=False on
all five entities instead -- same conservative, non-existence-gated
treatment already used for tropical_night_mode and the fridge/cooktop
precedents it was modeled on. Golden fixtures and tests updated to
match; the five sensors are bound-but-disabled on windfree/#17-style
boards again rather than unbound.

Also added icons for the AC fan_mode values #170 missed -- the raw
numeric labels ("1".."5") that TP1X_DA-AC-RAC-01001 and the window-AC
board report instead of turbo/max -- and swapped the whole fan-speed
icon family to mdi:fan-speed-1/2/3 for a more purpose-built look than
the generic speedometer, applied consistently to both the AC climate
card and the air purifier fan. Fixed motiondirect/motionindirect to
match core's smartthings integration's arrow pairing (previously
inverted).

Known limitation, not fixed here: enabled_default only affects newly
registered entities. Anyone who already has tropical_night_mode or the
five air-quality sensors enabled from #164 (a narrow window before
this fix, but real) won't see them auto-disable -- they'd need to
disable them by hand in Settings > Devices > Entities. A real fix
needs a one-time entity-registry migration, which this integration has
no existing infrastructure or test coverage for; scoping that felt
like its own follow-up rather than something to bolt on here.
2026-07-28 19:07:59 +00:00
Marc Billow 739881de16 Gate AC tropical night mode and air-quality sensors on real capability signals (#166)
Issue #166 (ARxxTXFCAWKNEU, board ARTIK051_PRAC_20K) reported tropical
night mode, clean level, dust, fine dust, odor, and super fine dust
entities showing up even though the reporter's units have no such
physical features. All six were added in #164.

The Sleep_<N> options token backing tropical_night_mode is present in
every AC dump on record regardless of confirmed reality, so there's no
usable signal at boot time -- it's now registered but disabled by
default (matching the precedent already set by fridge.rack_count /
cooktop.paired_hood_model), letting units that do have it opt in.

/sensors/vs/0's item-type list has the same problem (all five types
always listed, permanently zero on this board), but there turned out
to be a real tell: a top-level x.com.samsung.da.cleanLevel scalar is
present only alongside genuinely populated readings on every dump on
record (tp1x_da_ac_rac_01011, the tp1x_da_ac_air air purifier fixture)
and absent on every all-zero ARTIK051_PRAC_20K dump, including both
#166 units and the original windfree/#17 fixtures this capability was
first verified against -- which, per their /information/vs/0, turn out
to be the same board revision as #166's units, so that "verification"
never actually proved a real sensor either. AIR_QUALITY's exists_fn now
requires that scalar, and the windfree/airconditioner golden fixtures
are updated to match (those five entities no longer bind there).
2026-07-28 18:12:02 +00:00